My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5130 20th St
Zephyrhills
>
Building Department
>
Building Plans
>
5130 20th St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 8:26:20 PM
Creation date
2/18/2025 4:25:00 PM
Metadata
Fields
Template:
Building Plans
Street #
5130
Location
20th St
Contractor
Bailey Construction
Building Plans - Permit #
19551
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I HEREBY CERTIFY THAT I HAVE REVIEWED <br />THIS PLAN AND FOUND IT TO BE IN <br />COMPLIANCE WITH ASCE 7-101 & FBC 2017 <br />6TH. EDITION. <br />200 AMP MAIN BREAKER <br />40 CIRCUIT SURFACE MOUNT <br />PANEL I <br />METER CAN BY <br />ELECTRIC UTILITY CO. 200 <br />AMP <br />L-2" C WITH 3-4/0 THW AL <br />TO UNDERGROUND #4 CU, GROUND <br />SERVICE BY ELECTRIC <br />UTILITY CO. <br />I> TO COLD WATER LINE <br />(P`AX 8" GROUND LINE <br />SCO CO. ATTACH TO FOOTER REBAR) <br />(BACK TO BACK SERVICE/OFFSET SIMILAR) <br />A �EX�.200�AM �PE�LECT�Rl CAL RISER <br />N. T. S. <br />a <br />100 AMP MAIN BREAKER <br />20 CIRCUIT SURFACE MOUNT <br />PANEL <br />#4 SER CU. <br />- OR <br />100 #2 SER ALUMN. <br />AMP <br />ELECTRICAL PLAN <br />1/4$)=11-0" <br />ELECTRICAL NOTES <br />1. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH NATIONAL ELECTRICAL CODE <br />ALL APPLICABLE LOCAL ORDINANCES AND IN COOPERATION WITH THE <br />UTILITY COMPANIES. <br />2, COORDINATE ALL WORK WITH ALL TRADES. <br />3. MOUNT ALL OUTLETS AND RECEPTACLES PLUMB AND FLUSH WITH WALLS. <br />4. RECEPTACLES SHALL BE MOUNTED 12" AFF UNLESS SHOWN OTHERWISE. <br />5. INSTALL ELECTRICAL CABLE, WIRE AND CONNECTORS AS INDICATED IN <br />ACCORDANCE WITH THE MANUFACURERS WRITTEN INSTRUCTION,THE <br />APPLICABLE REQUIREMENTS OF NEC AND THE NATIONAL ELECTRICAL <br />CONTRACTORS ASSOCIATION "STANDARD OF INSTALLATION" AND <br />IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES TO ENSURE <br />THAT PRODUCTION SERVE THE INTENDED FUNCTIONS. <br />6. ALL WIRE SHALL BE STD. #10 AND #12 AND SHALL BE ROMEX OR NM <br />CABLE TYPE B OR APPROVED EQUAL. <br />7. COORDINATE ELECTRICAL REQUIREMENTS FOR A/C WITH A/C CONTRACTOR. <br />8, ALL RECEPTACLES IN SLEEPING ROOMS SHALL BE ON AN AFC1 <br />(ARC FAULT CURCUIT INTERRUPTER) PROTECTED CIRCUIT. <br />9. COMBINATION SMOKE DETECTOR/CARBON MONOXIDE DETECTOR TO BE <br />,__ LOCATED WITH -IN 10 f OF EACH BEDROOM <br />BEDROOM <br />EMERGENCY EGRESS <br />SHALL <br />BE DIRECTLY <br />TO OUTSIDE <br />EGRESS <br />WINDOWS SHALL BE <br />SIZED) <br />LOCATED AND <br />INSTALLED PER FBC 2017 <br />ALL BEDROOM ELECTRICAL OUTLETS MUST BE ARC -FAULT <br />ARC FAULT PROTECTED OUTLETS SHALL BE <br />INSTALLED PER NEC 210,12(B), <br />GFI PROTECTED CIRCUITS SHALL BE INSTALLED IN GARAGE ADDITIONS) <br />BATHROOMS & KITCHENS) LAUNDRY ROOMS AND OUTSIDE RECEPTACLES I <br />" �1111 I I I If,I <br />E I - <br />A/0- 5360,9 <br />OF Z. <br />qq <br />PROFESSIONAL ENGINEER SEAL <br />ENGINEER OF RECORD <br />David W. Smiffi P.E. <br />FLORIDA LICENSE NUMBER: 53608 <br />Plans By: <br />La deMontmollin <br />90 Country Club Lane <br />Mulberry, Fl. 33860 <br />Phone: (863)397-7525 <br />DATE: 02-15-18 <br />DRAWN BY: LE.D. <br />REVISION: I DATE: <br />R- 1 <br />R- 2 <br />R- 3 <br />R- 4 <br />PROJECT ADDRESS: <br />BU ERFIELD INVESTMENTS, INC. <br />5130 20TH. ST. <br />ZEPHYRHILLS, FL 33542 <br />CONTRACTOR: <br />JOEL BAILEY <br />HOUSE PLAN <br />ELECTRICAL PLAN <br />DWGm WB=7 REV. 0 <br />11T <br />
The URL can be used to link to this page
Your browser does not support the video tag.