Laserfiche WebLink
I HEREBY CERTIFY THAT I HAVE REVIEWED <br />THIS PLAN AND FOUND IT TO BE IN <br />COMPLIANCE WITH ASCE 7-10s & FBC 2017 <br />6TH. EDITION. <br />ENGINEER'S NOTES <br />ALL WORK TO BE DONE ACCORDING TO FLORIDA BUILDING CODES. <br />BUILDINGS OR STRUCTURES SHALL CONFORM TO <br />2017 FBC 6TH, EDITION BUILDING, <br />AN ADDITION TO A BUILDING OR STRUCTURE SHALL COMPLY WITH THE FBC'S AS <br />FOR NEW CONSTRUCTION WITHOUT REQUIRING THE EXISTING BUILDING OR STRUCTURE <br />TO COMPLY WITH ANY REQUIREMENTS OF THOSE CODES OR OF THESE PROVISIONS <br />EXCEPT AS REQUIRED BY CHAPTER 10, WHERE AN ADDITION IMPACTS THE EXISTING <br />BUILDING OR STRUCTURE, THAT PORTION SHALL COMPLY WITH THIS CODE. <br />CREATION OR EXTENSION OF NONCONFORMITY, AN ADDITION SHALL NOT CREATE OR <br />EXTEND ANY NONCONFORMITY IN THE EXISTING BUILDING TO WHICH THE ADDITION IS <br />BEING MADE WITH REGARD TO ACCESSIBILITY, STRUCTURAL STRENGTH, FIRE SAFETY, <br />MEANS OF EGRESS, OR THE CAPACITY OF MECHANICAL, PLUMBING, OR ELECTRICAL <br />SYSTEMS. <br />ASSUMED SOIL BEARING CAPACITY TO BE 2000 PSF, SOIL CAPACITY TO BE VERIFIED <br />BY CONTRACTOR PRIOR TO CONSTRUCTION, INFORM ENGINEER OF VARIATIONS. <br />FOOTINGS TO BE EXCAVATED TO CLEAN SOIL, FREE OF VEGETATION AND <br />DELETERIOUS MATTER. CONCRETE SHALL BE PLACED ON AN UNDISTURBED BASE. <br />CONCRETE 1 <br />MINIMUM COMPRESSIVE CONCRETE STRENGTH TO BE 2500 PSI IN 28 DAYS, ALL <br />CONCRETE SHALL BE 'READY MIXED' AND IN ACCORDANCE WITH A.S.T.M, <br />SPECIFICATION C-94. <br />SLAB ON FILL : <br />INTERIOR CONCRETE SLABS POURED ON FILL TO BE POURED OVER WATERPROOF <br />MEMBRANES, ALL SLABS TO BE REINFORCED WITH 6X6 10/10 WELDED WIRE MESH, <br />LUMBER 1 <br />1. STORE LUMBER OFF GROUND, KEEP WELL VENTILATED AND COVERED. <br />2. CURRENT EDITION, ASSOCIATION GRADING RULES GOVERN. <br />3, ALL LUMBER SHALL BEAR GRADE MARK OF AN ASIC BOARD OF REVIEW AGENCY, <br />4, ANY SPECIES ALLOWED UNLESS OTHERWISE NOTED, <br />5. SIZES ARE NOMINAL. ACTUAL SIZES SHALL CONFORM TO AMERICAN <br />LUMBER STANDARD PS 20-70, <br />6, MOISTURE CONTENT OF LUMBER 2' OR LESS IN THICKNESS SHALL BE <br />19% OR LESS AT THE TIME OF INSTALLATION, <br />STRUCTURAL LUMBER TO HAVE 1120 PSI FIBER STRESS IN CONFORMANCE TO <br />AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (AITC) SPECIFICATIONS. ALL <br />LUMBER AGAINST MASONRY OR CONCRETE TO BE PRESSURE TREATED. <br />TERMITE TREATING : <br />SOIL BELOW STRUCTURE TO BE TERMITE TREATED TO A DISTANCE OF 5'-0' <br />BEYOND THE PERIMETER LINES OF THE BUILDING, <br />ALL STEEL SHALL BE 40 KSI WITH A MINIMUM CLEAR COVER OF 3' AGAINST <br />SOIL, AND SHALL HAVE A MINIMUM LAP OF 40 TIMES THE DIAMETER OF THE REBAR, <br />HEADERS SHALL BE DBL. 2X MEMBERS AND LAMINATED W/1/2' PLYWOOD <br />GLUED W/CONSTRUCTION ADHESIVE AND NAILED W/#16D COMMONS 16' O,C. <br />ALL FASTENERS SHALL COMPLY WITH THE DESIGN LOADS. <br />CONTRACTOR SHALL HAVE MANUFACTURERS SPECIFICATIONS (CUT SHEETS) ON SITE <br />AT THE TIME OF INSPECTION, FOR REVIEW BY THE BUILDING INSPECTOR, <br />TO MEET LOADS AS INDICATED, <br />DOORS & WINDOWS <br />ENGINEERS NOTES1 <br />DESIGN LOADS1 <br />A. WIND LOADS, PER: <br />1) RISK CATEGORY h - PER (TABLE 1604.5/TABLE 1.5-1) <br />2) EXP. -C-, PER TABLE 1609.4,5/SECTION 26.7.5 <br />3) THE BASIC ULTIMATE DESIGN WIND SPEED, V (ULT) = 140 MPH u(t 3 SEC GUST <br />4) NOMINAL DESIGN WIND SPEED, V (ASD) = 110 MPH asd 3 SEC GUST <br />5) INTERNAL PRESSURE COOFFICIENT, GCPI = .18 ENCLOSED PER TABLE 26.11.1 <br />6) COMP. & CLADDING PRESSURES PER TABLE R301,2(2), UNLESS SPECIFICALLY LABELED ON PLAN <br />B, LIVE LOADS, PER 1607, INCLUSIVE BUT NOT LIMITED TO: <br />1) ROOF LIVE LOAD = 20 PSF <br />2) FLOOR LIVE LOAD = 40 PSF <br />3) UNINHABITTABLE ATTIC LIVE LOAD = 10 PSF <br />4) HABITTABLE ATTIC LIVE LOAD = 20 PSF <br />C. DEAD LOADS, PER 1606, INCLUSIVE BUT NOT LIMITED T01 <br />1) ROOF DEAD LOAD (TOP CHORD) = 25 PSF <br />2) ROOF DEAD LOAD (BOTTOM CHORD) = 10 PSF <br />3) FLOOR DEAD LOAD 20 PSF <br />APPLICABLE CODES: <br />6TH. EDITION, 2017 FLORIDA BUILDING CODE, BUILDING, PLUMBING, <br />MECHANICAL, FUEL GAS, AND/OR EXISTING BUILDING <br />GTH. EDITION, 2017 FLORIDA FIRE PREVENTION CODE (IF APPLICABLE) <br />2014 NATIONAL ELECTRICAL CODE <br />DATA SUMMARY1 <br />BUILDING USD SINGLE FAMILY RESIDENCE TYPE R1. <br />CONSTRUCTION TYPE V, UNPROTECTED, UNSPRINKLED <br />ALL BEDROOMS REQUIRE AN OUTSIDE WINDOW OR DOOR OPERABLE FROM INSIDE WITHOUT THE <br />USE OF TOOLS AND PROVIDING A CLEAR OPENING OF NOT LESS THAN 20- WIDTH, 24- IN HEIGHT <br />& 5,7 SQ. FT, IN AREA, THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44- OFF THE <br />FLOOR AND NO PART OF THE OPERATING MECHANISM SHALL BE PLACED HIGHER THAN 54, A.F.F. <br />WINDOWS GREATER THAN 72' ABOVE 72' FINISHED GRADE SHALL HAVE THW WINDOW SILL HEIGHT <br />GREATER THAN 24' OR PROVIDE AN FALL PREVENTIVE DEVICE PER R616.2. <br />DOORS & WINDOWS <br />THE OPERATING MECHANISM FOR SINGLE HUNG WINDOWS SHALL BE AT OR NEAR THE SILL, <br />WINDOWS INDICATED WITH (E) OR EGRESS MUST BE MANUFACTURED TO CONFORM TO THE BLDG. <br />CODE W/ RESPECT TO MIN. EMERGENCY EGRESS REQUIREMENTS PER N,F.P.A, 101 CHAPTER 24, <br />ALL GLASS WITHIN 24- OF ANY DOOR, SLIDING GLASS DOOR, ALL GLAZING AT TUB AND <br />SHOWER ENCLOSURES AND WINDOWS WITHIN LESS THAN 60" AVOVE STAIR LANDINGS OR TREADS SHALL BE <br />TEMPERED SAFETY GLASS, SEE ADDITIONAL SAFETY GLAZING REQUIREMENTS PER 2010 FBCR R308, <br />SINGLE SWING EXTERIOR DOORS CONNECTING GARAGE TO LIVING AREAS SHALL BE EQUIPPED WITH <br />SOLID WOOD DOORS NOT LESS THAN 1 3/8' (35 MM) THICKNESS, SOLID OR HONEYCOMB CORE <br />STEEL DOORS NOT LESS THAN 1 3/8' (35 MM) THICK, OR 20 MINUTE FIRE -RATED DOORS. <br />WHERE MASONRY OPENINGS REQUIRE WOOD FRAMING, TO FIT WINDOW OR DOOR SIZES, PRESSURE <br />TREATED 2x8 STUDS MAY BE SECURED TO THE MASONRY WITH 1/4' DIA. x 3 1/2' TAPCON SCREWS, 6' <br />FROM EACH END AND 12' C/C. ADDITIONAL FRAMING MEMBERS SHALL BE NAILED TO PRIOR STUD W1 <br />(2) ROWS OF 2cl NAILS AT 10' C/C. <br />GYPSUM WALLBOARD <br />PROVIDE 112" NO SAG GYP. BOARD ON ALL CEILINGS. PROVIDE 5/8' TYPE 'X' GYP, BPOARD ON ALL <br />GARAGE CEILINGS WHERE HABITABLE SPACE EXISTS ABOVE, GARAGE SHALL BE SEPARATED FROM THE <br />RESIDENCE AND IT'S ATTIC AREA BY NO LESS THAN 1/2' GYP, BOARD APPLIED TO THE GARAGE SIDE. <br />HARDIE BACKER TO BE USED AT ALL SHOWER AND TUB LOCATIONS, UP TO 8' A.F.F. <br />NON-13EARING INTERIOR PARTITIONS <br />ALL INTERIOR NON BEARING PARTITIONS SHALL BE 2X4 SPF @ 16' O.C. MAX, SPACING WITH SINGLE TOP <br />AND BOTTOM PLATE W/ 112' GYP. DRYWALL EACH SIDE, <br />FLORMA "PROVED PRODUCTS LIST <br />Parent Approval <br />Manufacturer <br />Category <br />Subcategory <br />App/Seq # Product MOM # or Name <br />Model Description I <br />FL15220.6 <br />Plastico, Inc. <br />Exterior Doors <br />Swinging Ext. Door <br />i Opaque Fiberglass Door <br />'Entry Door <br />FL15220.5 <br />Plastico, Inc. <br />Exterior Doors <br />Ext.-Door Assemblies J <br />Opaque Fiberglass Door <br />Glazed Fiberglass Door <br />-Swinging <br />i FL15279-R5 <br />Clopay Building Products Company <br />Exterior Doors <br />Sectional Ext. Door Assemblies <br />FL14911-R8 <br />Silverline Bldg. Products <br />Windows <br />i Single -Hung <br />Aluminum <br />FL14911-R9 <br />Silverline Bldg. Products <br />Windows <br />Single -Hung <br />urninum <br />FL6067-R7 <br />Silverline Bldg. Products <br />Windows <br />Mullion <br />Aluminurn <br />FL 16626-1 -R3 <br />Tamko Building Products <br />Roofing <br />Underlayments <br />TW Underlayment <br />FL16305.1-R3 <br />Tamko Building Products <br />Roofing <br />Asphalt Shingles <br />Fiberglass Reinforced <br />FL15272 <br />Alside <br />Panel Walls <br />Soffits <br />J �Aluminum <br />FL1 1473-R2 <br />Simpson Strong -Tie Co. <br />Structural Components <br />Truss Anchors <br />;HETA <br />Embedded Truss Anchor <br />FLI 1473-R2 <br />Simpson Strong -Tie Co. <br />Structural Components <br />Truss Anchors <br />':META <br />Embedded Truss Anchor <br />FLl045_6.2-R4__.__ <br />ie i <br />Simpson Strong-Ti Co. <br />Structural Components <br />Wood Connectors Anchors J_ <br />H2,5 <br />FL10456.10-R4 <br />Simpson Strong -Tie Co. <br />Structural Components <br />Wood Connectors, Anchors <br />Spi <br />FL10456.10-R4 <br />Simpson Strong -Tie Co. <br />Structural Components <br />Wood Connectors Anchors <br />SP2 <br />FLI 1473-R2 <br />Simpson Strong -Tie Co. <br />Structural Components <br />Wood Connectors Anchors <br />LSTA12 <br />Strap Ties <br />NoTjE M:j?, <br />FLORIDA APPROVED WINDOWS AND DOORS RATED FOR INDICATED DESIGN PRESSURES AND INSTALLED PER DOOR MANUFACTURERS SPECIFICATIONS. <br />COMPONENTS AND CLADDING - EXP, 'C' PER TABLE R301.2 <br />140 Utt - DESIGN WIND PRESSURE FOR WALLS, DOORS & <br />WINDOWS (NOMINAL) <br />COMPONENT <br />ZONE <br />EFFECTIVE WIND AREA <br />WALL <br />10 SQ. FT. <br />20 SQ, FT, <br />50 SQ. FT, <br />100 SQ. <br />FT, <br />500 SQ, FT, <br />WALL <br />+45.5 PSF / -49.3 PSF <br />+43.5 PSF / -47.3 PSF <br />+40,8 PSF / -44.6 PSF <br />+38.7 PSF / <br />-42.0 PSF <br />+33.9 PSF / -37.e PSF <br />WALL <br />+45.5 PSF / -60.9 PSF <br />+43�5 PSF / -56.8 PSF <br />+40.8 PSF / -51.3 PSF <br />+38.7 PSF / <br />-47.3 PSF <br />+33.9 PSF / -3&3 PSF <br />NOTE: <br />ALL EXTERIOR DOORS & WINDOWS ASSEMBLIES SHALL SATISFY THE REQUIREMENTS IN FBC 2010. ALL CONNECTIONS TO BUILDING STRUCTURE <br />SHALL HAVE THE CAPACITY TO WITHSTAND THE PRESSURES INDICATED IN THIS SCHEDULE. <br />3'-0" FROM THE BUILDING EDGE GOVERNS FOR ZONE 5. <br />DESIGN OPENING PRESSURES <br />ENCLOSED BUILDING EXPOSURE 'Bo <br />DOOR/WINDOW <br />TAG <br />ZONE <br />PRESSURE <br />5068 FR. DR. <br />4 <br />40.8 <br />44,6 <br />3068 DR. <br />4 <br />43.5 <br />47.3 <br />2868 FR. DR, <br />4 <br />43.5 <br />47.3 <br />37x63 <br />25 SH <br />4 <br />43.5 <br />47,3 <br />2-37x63 <br />2-25 SH <br />4 <br />40.8 <br />44.6 <br />37x5l <br />24 SH <br />4 <br />43,5 <br />473 <br />51 5/8 x 50 5/8 <br />35 SH <br />4 <br />43,5 <br />473 <br />26 x 50 5/8 <br />34/2 SH <br />4 <br />45.5 <br />49.3 <br />1670 OHD <br />4 <br />33,9 <br />37.8 <br />REQUIRED ATTIC VENTILATION <br />AREA OF ATTIC <br />2219 <br />NET FREE VENTILATION AREA REQ'D. <br />1/300 <br />REQ'D. VENTILATION ATTIC <br />2219/300 <br />7.397 <br />VENTILATION AREA x SQ. INCHES PER FOOT (144) <br />1065.12 <br />MIN. REQUIRED VENTILATION IN UPPER PORTION OF ATTIC <br />532.56 <br />OFF RIDGE VENTILATION AREA 115 <br />SQ. INCH PER VENT <br />532.56/115 <br />TOTAL # OF VENTS REQUIRED <br />4.53 <br />TOTAL # OF VENTS PROVIDED <br />5 <br />SOFFIT VENTILATION AREA 11.736 <br />SQ, INCH PER PER L.F. <br />532.56/11.736 <br />TOTAL LINEAL FT. OF SOFFIT VENTING REQUIRED <br />45.378 <br />* AREA OF ATTIC IS THE PERIMETER OF THE HOUSE <br />(EXTERIOR OF WALL TO EXTERIOR OF WALL, NO OVERHANGS <br />INCLUDED) <br />DRAWING PAGE INDEX <br />W13-1 - ELEVATIONS <br />W13-2 - FLOOR PLAN <br />WB-J - FOUNDATION PLAN <br />WB-4 - ROOF PLAN <br />W13-5 - WALL SECTION & DETAILS <br />W13-6 - ROOF NAILING <br />W13-7 - ELECTRICAL PLAN <br />W13-8 - ENGINEERING NOTES <br />NN E L T,0 4, <br />. 00 ..0 <br />No.53608 <br />STATE 0j= -4 <br />All <br />0" <br />W, <br />PROFESSIONAL ENGINEER SEAL <br />ENGINEER OF RECORD <br />David W. Smith P.E. <br />FLORIDA LICENSE NUMBER: 53608 <br />Plans By: <br />Larry deMontmollin <br />90 Country Club Lane <br />Mulberry, Fl. 33860 <br />Phone: (863)397-7525 <br />DATE: 02-15-18 <br />DRAWN BY: LE.D. <br />REVISION: <br />Rr 1 <br />Rr 2 <br />Rr 3 <br />Rr 4 <br />DATE: <br />PROJECT ADDRESS: <br />BU ERFIELD INVESTMENTS, INC. <br />5130 20TH. ST. <br />ZEPHYRHILLS, FL 33542 <br />CONTRACTOR: <br />JOEL BAILEY <br />HOUSE PLAN <br />ENGINEERING W�TES <br />DWG, WB=8 <br />nu <br />xxjuvs 0 <br />