My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5335 8th St (7)
Zephyrhills
>
Building Department
>
Building Plans
>
5335 8th St (7)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 6:07:50 PM
Creation date
2/18/2025 4:25:31 PM
Metadata
Fields
Template:
Building Plans
Street #
5335
Location
8th St
Contractor
Alarm Fire & Communication System
Building Plans - Permit #
18120
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ALARM & <br />COMMUNICATION <br />SYSTEMS, INC. <br />._� A,D FACP' <br />TO <br />22- ,/ FATC <br />- CMD'A na <br />o �14 <br />2 <br />219 WOMEN' <br />LECTRICAL RESTRO M <br />A,D <br />SECOND_ <br />4' 0 5' <br />`r <br />STORAGE <br />�, IS <br />216 <br />—214 <br />STO <br />E <br />SPARE tc� <br />1— <br />E <br />FLOOR FIRE ALARM <br />A,D <br />L <br />2CITYASST. <br />CLERK-� !\ <br />AA_ <br />233 =� 202 <br />WORK ROOM RECEPTION <br />212 <br />PURCHI� <br />AGIiW <br />211 <br />& H VAC PLAN <br />1/8" = 1'-0" <br />207 <br />HR STORAGE <br />210 <br />FINAN <br />DIRECTOR <br />A,D <br />201 <br />WAITING AREA <br />208 <br />HR <br />DIRECTOR <br />FIRE ALARM GENERAL NOTES <br />A. ALL FIRE ALARM DEVICE LOCATIONS AND DETAILS ARE FOR REFERENCE ONLY. LOCAL GOVERNING <br />CODES AND REQUIREMENTS SHALL TAKE PREFERENCE OVER ALL DETAILS FOR LOCATIONS AND <br />MOUNTING HEIGHTS. VERIFY LOCAL GOVERNING CODES AND REQUIREMENTS WITH LOCAL <br />INSPECTION DEPARTMENT PRIOR TO BID. COMPLETE FIRE ALARM SYSTEM, INSTALLATION AND <br />OPERATION SHALL MEET THE REQUIREMENTS OF THE LOCAL AUTHORITY HAVING JURISDICTION. <br />B. THE CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CEILING MOUNTED DEVICES AND <br />RELATED ITEMS WITH THE ARCHITECTURAL REFLECTED CEILING PLANS <br />C. ALL CONDUIT, CABLES, AND DEVICES LOCATED IN FIRE RATED WALLS SHALL BE INSTALLED IN <br />ACCORDANCE WITH N.E.C. SECTION 300.2 1. REFER TO ARCHITECTURAL DRAWINGS FOR FINAL <br />RATED WALL LOCATIONS. <br />D. ELECTRICAL CONTRACTOR SHALL NOT LOCATE SMOKE DETECTORS CLOSER THAN 3 FEET FROM <br />ANY MECHANICAL AIR SUPPLY OR RETURN DIFFUSER, GRILLE, OR REGISTER PER NFPA. ELECTRICAL <br />CONTRACTOR SHALL COORDINATE WITH OTHER TRADES FOR LOCATION OF DETECTOR. <br />E. THE ELECTRICAL ADDRESS OF THE FIRE ALARM DEVICE SHALL BE SHOWN ON THE BASE OF EACH <br />AND EVERY DEVICE FOR EASE OF IDENTIFICATION. <br />F. ALL SIGNAL AND INITIATING DEVICE CIRCUITS SHALL BE CLASS "B". <br />G. AUDIO DEVICES SHALL MEET OR EXCEED THE REQUIRED DECIBEL LEVELS IN NFPA 72. <br />H. WHERE CEILING -MOUNTED SMOKE DETECTORS ARE TO BE INSTALLED FOR DOOR HOLDER <br />CONTROL ON A SMOOTH CEILING FOR A SINGLE OR DOUBLE DOORWAY, THEY SHALL BE LOCATED <br />AS FOLLOWS: <br />A) ON THE CENTERLINE OF THE DOORWAY, AND <br />B) NO MORE THAT 5 FT. MEASURED ALONG THE CEILING PERPENDICULAR TO THE <br />DOORWAY. <br />I. DO NOT INSTALL SMOKE DETECTOR HEADS UNTIL ALL MAJOR CONSTRUCTION AND CLEANING IS <br />COMPLETE. CLEANING OF DETECTOR HEADS CONTAMINATED BY CONSTRUCTION DUST IS <br />MANDATORY. <br />J. CONTRACTOR SHALL TEST THE SENSITIVITY OF ALL CEILING AND DUCT SMOKE DETECTORS <br />INSTALLED IN THE FACILITY AND PREPARE A TEST REPORT FOR INCLUSION IN CLOSE OUT <br />DOCUMENTS. CONTRACTOR SHALL PROVIDE A "RECORD OF COMPLETION' FOR THE FIRE ALARM <br />SYSTEM AT FINAL SURVEY. <br />K. PROVIDE DEDICATED 1 20VAC CIRCUITS TO FIRE ALARM PANEL AND NAC PANELS. LABEL <br />DEDICATED CIRCUIT "FIRE ALARM SYSTEM" AND PLACE LOCK OUT IN CIRCUIT AT ELECTRICAL PANEL. <br />L. AUDIBLE/VISUAL AND VISUAL ONLY DEVICES SHALL BE PLACED 80", TO THE BOTTOM OF THE <br />DEVICE, ABOVE THE HIGHEST FLOOR LEVEL WITHIN THE SPACE OR G" BELOW THE CEILING, <br />WHICHEVER IS LOWER. TO BE IN ACCORDANCE WITH NFPA 72, AUDIBLE/VISUAL AND VISUAL ONLY <br />DEVICES SHALL BE MOUNTED WITH THE ENTIRE LENS BETWEEN 80" AND 90 ABOVE THE FINISHED <br />FLOOR (NFPA 72-7.5.4). REFER TO EQUIPMENT DATA SHEET FOR EXACT BACKBOX MOUNTING <br />HEIGHTS. <br />M. DUCT DETECTORS SHALL BE READILY ACCESSIBLE FOR SERVICING AND TESTING, PER NFPA 72 <br />5-1 I .G.3. DETECTORS SHALL BE MOUNTED IN ACCORDANCE WITH THE MANUFACTURER'S <br />RECOMMENDATION. <br />N. ANNUNCIATORS SHALL PROVIDE DEVICE TYPE, LOCATION, AND SMOKE COMPARTMENT FOR ALARM <br />DEVICES. A SMOKE COMPARTMENT FLOOR PLAN SHALL BE LOCATED AT EACH ANNUNCIATOR. <br />O. FIRE ALARM SYSTEM SHALL BE A FULLY ADDRESSABLE CLASS B, STYLE 4 SYSTEM. <br />P. ALL WALL -MOUNTED FIRE ALARM DEVICES SHALL BE LOCATED A MINIMUM OF 18" FROM EDGE OF <br />WINDOW OPENINGS TO AVOID CONFLICT WITH WINDOW TREATMENTS. <br />0 FIRE ALARM KEYED NOTE <br />SOME NOTES MAY NOT APPLY TO THIS SHEET <br />I HEAT DETECTORS LOCATED IN THE HOISTWAY SHALL HAVE AUXILIARY CONTACTS TIED INTO THE <br />SHUNT TRIP BREAKERS AND ARE REQUIRED TO AUTOMATICALLY DISCONNECT THE MAIN POWER <br />TO THE ELEVATOR CONTROLS PRIOR TO APPLICATION OF WATER BY THE SPRINKLER SYSTEM. THIS <br />METHOD OF POWER DISCONNECT SHALL NOT BE SELF -RESETTING. HEAT DETECTORS MUST BE <br />INSTALLED WITHIN 24" OF SPRINKLERS. <br />2 SMOKE DETECTORS IN THE HOISTWAY SHALL RECALL THE ELEVATOR TO THE DESIGNATED LANDING. <br />IF THE ELEVATOR MACHINE ROOM IS AT THE DESIGNATED LANDING THEN THE ELEVATOR SHALL BE <br />RECALLED TO AN ALTERNATE LANDING. <br />3 SMOKE DETECTOR SHALL HAVE AUXILIARY CONTACTS IN ORDER TO WIRE INTO THE ELEVATOR <br />CONTROLLER FOR ELEVATOR RECALL FUNCTION. <br />4 PROVIDE RELAY WIRED INTO DOOR LOCKING MECHANISM FOR RELEASE DURING BUILDING ALARM. <br />G SEE MECHANICAL CONNECTION SCHEDULE ON THIS SHEET FOR ELECTRICAL REQUIREMENTS OF ALL <br />MECHANICAL EQUIPMENT. PROVIDE 1 20V CIRCUIT 2N-GO TO ALL VAV UNITS FOR CONTROLS. <br />7 TYPICAL MAINTENANCE RECEPTACLE MOUNTED ADJACENT TO THE RESPECTIVE MECHANICAL <br />EQUIPMENT. USE RECEPTACLE AND CIRCUIT FOR ALL 120 VOLT REQUIREMENTS AT THE <br />EQUIPMENT. <br />8 RECEPTACLE MOUNTED ADJACENT TO HVAC UNIT FOR CONDENSATE PUMP. VERIFY EXACT <br />LOCATION IN FIELD PRIOR TO ROUGH IN. <br />CONDUCTOR LEGEND <br />SYMBOL <br />DESCRIPTION <br />A <br />ADDRESS LOOP CABLE - WINDY CITY #728100-S <br />SLC - 16/2 UNSHIELDED, SOLID, FPLR, RED <br />B <br />POWER: 24VDC - (2) SOUTH WIRE #12 THHN <br />C <br />REMOTE TEST INDICATOR - (3) S. WIRE #12 THHN <br />D <br />STROBE CKT - (2) S. WIRE #12 THHN <br />(1) BLUE & (1) YELLOW <br />F <br />DOOR HOLDER CKT - (2) S. WIRE #12 THHN <br />(1) WHITE & (1) BLK W/TRACER <br />G <br />GAS SHUTDOWN CKT - (2) S. WIRE #12 THHN <br />(1) PINK & (1) BLK <br />AHU SHUTDOWN CKT - (2) S. WIRE #12 THHN <br />H <br />(1) GRAY & (1) PINK <br />4301 W. South Avenue <br />Tampa, FL., 33614 <br />Ph: 813.873.1851 <br />Fax: 813.879.0768 <br />io <br />C <br />0 0 <br />• m 0) <br />E <br />•V • OU <br />Cv m <br />M _c <br />EN <br />y � Z <br />OQ <br />E <br />Q � <br />F <br />7 <br />U <br />N <br />REVISION NO./C)ATE <br />ORIGINAL DRAWING DATE <br />Al <br />A 2 <br />DATE ISSUED: <br />CHECKED BY: GT <br />DRAWN BY: JP <br />SYSTEM <br />SECOND FLOOR <br />FIRE ALARM PLAN <br />DRAWINQ N0= <br />E�602 <br />JOB# <br />J <br />Q <br />H <br />
The URL can be used to link to this page
Your browser does not support the video tag.