My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5335 8th St (7)
Zephyrhills
>
Building Department
>
Building Plans
>
5335 8th St (7)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 6:07:50 PM
Creation date
2/18/2025 4:25:31 PM
Metadata
Fields
Template:
Building Plans
Street #
5335
Location
8th St
Contractor
Alarm Fire & Communication System
Building Plans - Permit #
18120
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 DOOR <br />Typical POE Configuration <br />Compact Plastic Enclosure <br />CAT6 <br />CABLE <br />(DTAOTA <br />(RACK) <br />— 18/4 UIN-SHIELDED <br />------------ 1 <br />Exit Device <br />18/4 SHIELDED <br />Keypad <br />FK <br />Strike <br />18/4 UN -SHIELDED <br />DOOR CONTROLLER/ <br />POWER SUPPLY <br />f6c] o <br />Psi Fof7-= <br />ACCESS CONTROL SYSTEM DETAIL <br />N.T.S. <br />FAA - <br />101C <br />RECEPTION <br />KNOX BOX <br />NAC-2 <br />FACUIFAC <br />FIRE ALARM <br />CONTROL UNIT <br />(FACU) <br />FACP WITH <br />REQUIRED <br />TERMINAL <br />CABINETS AND <br />POWER <br />SUPPLIES NAC POWER <br />227 SUPPLY <br />SERVER ROOM <br />INIT <br />NAC- 1 <br />NOTE: RISER IS DIAGRAMMATIC. REFER TO <br />FLOOR PLAN FOR QUANTITIES AND <br />LOCATIONS OF DEVICES. RISER MAY NOT <br />REFLECT FLOOR PLAN DEVICE <br />LOCATIONS, TYPES, QUANTITIES OR <br />DESIGNATION. THE CONTRACTOR SHALL <br />UPDATE RISERS WITH THE SHOP <br />DRAWINGS SUBMITTALS. <br />04 +4 wp <br />I - <br />LEVEL 1 T T <br />;T ;T� T (T T T <br />T <br />40 <br />LEVEL2 <br />410 4104 <br />FIRE ALARM SYSTEM DETAIL <br />N.T.S. <br />FIRE ALARM FLORIDA ADMINISTRATIVE CODE 61G15-32.008 COMPLIANCE <br />61G15-32.008(4) COMPLIANCE: <br />THE FOLLOWING IS A SUMMARY OF 61G15-32.008 ITEMS 4A THRU 40 REQUIREMENTS: <br />(A) THE PLANS INCLUDE A SYMBOLS LEGEND, SYSTEM RISER DIAGRAM SHOWING ALL INITIATION AND NOTIFICATION COMPONENTS, AND <br />CABLING REQUIREMENTS. THE GENERAL OCCUPANCY OF THE PROTECTED PROPERTY IS BUSINESS. EACH ROOM AND AREA USE IS BASED <br />ON FEATURES SHOWN AND THE ROOM NAME. <br />(B) INITIATION AND NOTIFICATION DEVICES ARE SHOWN. ELEVATOR DEVICES AND CONTROLS, SMOKE CONTROL SYSTEMS, DAMPERS, AND <br />SPECIAL DOORS ARE SHOWN. <br />(C) STROBE INTENSITY AND SPEAKER OUTPUT RATINGS FOR ALL NOTIFICATION DEVICES IS SHOWN ON LEGEND (75 cd FOR <br />HORN/STROBES AND 15 cd FOR STROBE LIGHTS). <br />(D) THE CLASS AND STYLE OF CIRCUITS AS LISTED IN THE NFPA 72 SHALL BE: <br />INITIATING CIRCUIT AND NOTIFICATION CIRCUITS: CLASS B <br />(E) SEE TABLE THIS SHEET FOR FUNCTIONS REQUIRED BY THE ALARM AND CONTROL SYSTEMS INCLUDING THE TRANSMISSION OF <br />EMERGENCY SIGNALS BEING MONITORED OR ANNUNCIATED. <br />(F) THE FIRE ALARM SHALL BE ADDRESSABLE, NO ZONING. <br />(G) SEE RISER FOR SURGE PROTECTIVE DEVICE LOCATION, PROVIDE PER MANUFACTURER REQUIREMENTS. <br />(H) NO SYSTEM DEVICES ARE SUBJECT TO ENVIRONMENTAL FACTORS. ALL EQUIPMENT IS LOCATED IN CONDITIONED SPACES. <br />(1) THE ELECTRICAL SITE PLAN SHOWS THE BUILDING LOCATION ON SITE. THERE IS A TAMPER SWITCH AT THE SITE BOUNDARY, <br />LOCATED PER CIVIL DRAWINGS. NO EXTERIOR NOTIFICATION APPLIANCES PROVIDED (HORN/STROBE) UNLESS REQUIRED BY AHJ. <br />(J) NO SPECIAL SMOKE SYSTEM DESIGN AND DETAILS. <br />(K) SMOKE STRATIFICATION IS NOT ANTICIPATED. <br />(L) PERFORMANCE BASED DESIGN NOT UTILIZED. <br />(M) THE SYSTEM DESIGN PROVIDES A GENERAL EVACUATION SIGNAL (NO ZONED SIGNALS). <br />(N) THERE IS NO UNDERGROUND, WET LOCATION OR CAMPUS STYLE WIRING EXCEPT FOR CONNECTION TO TAMPER SWITCH. <br />(0) SEE SPECIFICATIONS AND FIRE ALARM SYSTEM AND RISER NOTES ON THIS SHEET FOR REQUIREMENTS FOR OPERATIONS AND <br />MAINTENANCE PROCEDURES, MANUALS, SYSTEM DOCUMENTATION, AND INSTRUCTION OF OWNER'S OPERATING PERSONNEL. <br />2 DOORS CAT6 <br />CABLE <br />1 Door Standard TO <br />Metal Enclosure DATA) <br />shown with 1-Door (RACK <br />Add -on Board <br />4 A, 12 VDC <br />Power <br />supply <br />18/4 SHIELDED <br />18/4 SHIELDED — <br />WBaftery <br />Exit Device <br />DOOR CONTROLLER/ 19 <br />POWER SUPPLY FP sl <br />0 1 -Door <br />Add -on Board <br />e o (NXD1) <br />Exit Device <br />18/4 S IELDED — C <br />18/4 U N-SHIELDED <br />18/4 SHIEL:IED L 18/4 Uri -SHIELDED <br />Strike <br />F —01 <br />El 11 <br />'_00 0 A Strike <br />[ILI <br />0 <br />d <br />Keypad <br />Keypad <br />E <br />MAMUM CAPACTTY: 4 CONNECTIONS <br />QTY DESCRIPTION <br />X/Y CAT 6 MUM AS REWRED <br />1 4 PORT CDVERPIATE <br />(BLANKS SHALL BE INSTALLED IN UNUSED OLITLET PORM <br />1 UL USTED CATEGORY 6, 4PAIR CABLE, PULLED FROM EACH <br />OUTLET TO TELECOM ROOM OR NEAREST TERMINAL BOARD <br />OR RACK FOR TMINATION. <br />ALL JACKS SHALL BE %8B PIN CONIFIGURATION. <br />BACK BOX/CONDU1`T REQUIRE14ENT: <br />I - 40 x 4m x 2-1/ir BACK BOX WTTH SINGLE GANG PLASTER RING <br />1 - 1" CONDUFT STUB -UP TO ACcissnuaHLING WITH BUSHING <br />44' 44 X/y 180 44 X/y <br />AFF AFF <br />X== OF VOICE OUTLETS SHOWN ON MANS <br />Y= OF DATA OUTLETS SI-K)WN ON PLANS <br />INFORMATION MANAGEMENT OUTLET <br />DETAIL "A" <br />N.T.S. <br />PAIR 3 <br />EIA 568B PIN -OUT <br />n7� <br />MODULAR 14CK <br />CABLE PAIR <br />PAIR 2 <br />PAIR 4 <br />WHT/ORG <br />T2 <br />I > <br />ORG/WHT <br />R2 <br />2 <br />2 3 5 6 <br />7 8 <br />WHT/GRN <br />1-0 0 1-G BL IA G I -OR 8R <br />T3 <br />3 <br />1ACK POSITIONS <br />RI <br />4 > <br />BLU1WHT <br />WHT/BLU <br />T1 <br />5 > <br />GRN/WHT <br />R3 <br />6 > <br />EIA 568B (WECO) <br />WHT/BRN <br />T4 <br />7 > <br />MODULAR 14CK WIRING (FRONT VIEW) <br />BRN/WHT <br />R4 <br />8 > <br />MODULAR <br />JACK <br />WIRING <br />DETAIL <br />N.T.S. <br />NOTE: RISER IS DIAGRAMMATIC. REFER TO <br />FLOOR PLAN FOR QUANTITIES AND <br />LOCATIONS OF DEVICES. RISER MAY NOT <br />REFLECT FLOOR PLAN DEVICE <br />LOCATIONS, TYPES, QUANTMES OR <br />DESIGNATION. THE CONTRACTOR SHALL <br />CCTV CONNECTIVITY DETAIL UPDATE RISERS WITH THE SHOP <br />N.T.S. DRAWINGS SUBMITTALS. <br />/_%L_Mr_%1V1 09 <br />COMMUNICATION <br />SYSTEMS, INC. <br />4301 W. South Avenue <br />Tampa, FL., 33614 <br />Ph: 813.873.1851 <br />Fax: 813.879.0768 <br />'0 <br />r C <br />0 0 <br />om (0 <br />411 <br />0 <br />U <br />W L <br />E 0 <br />0 0 <br />40 0 <br />tj 4d L <br />z <br />LL <br />REVISION NO./OATE <br />ORIOINAL DRAVVINa DATE <br />DATE ISSUED: <br />CHECKED BY: <br />DRAWN BY - <br />SYSTEM <br />ELECTRICAL <br />SYSTEMS - <br />DETAILS& NOTES <br />DRAVVINa NO: <br />E�603 <br />>= <br />
The URL can be used to link to this page
Your browser does not support the video tag.