Laserfiche WebLink
SPECIFICATIONS <br />1. 1. CONSTRUCTION: <br />1. 1. 1. ACI 318 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, LATEST EDITION <br />1. 1. 2. ACI-ASCE 530, SPECIFICATIONS FOR MASONRY STRUCTURES, LATEST EDITION <br />1. 1. 3. ASTM C270, C476, C270 AND C90 SPECIFICATIONS FOR MASONRY STRUCTURES <br />1. 1. 4. NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION LATEST EDITION AND ALL <br />ACCOMPANYING SUPPLEMENTS. <br />1. 1. 5. THE FLORIDA BUILDING CODE: 6TH EDITION (2017) <br />1. 2. DESIGN: <br />1. 2. <br />1. <br />ACI 318 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, LATEST EDITION <br />1. 2. <br />2. <br />ACI-ASCE 530, SPECIFICATIONS FOR MASONRY STRUCTURES, LATEST EDITION <br />1. 2. <br />3. <br />ASTM SPECIFICATIONS FOR MASONRY STRUCTURES <br />1. 2. <br />4. <br />NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION , LATEST EDITION AND ALL <br />ACCOMPANYING SUPPLEMENTS. <br />1. 2. <br />5. <br />NATIONAL FOREST PRODUCTS ASSOCIATION, LATEST EDITION <br />1. 2. <br />6. <br />THE FLORIDA BUILDING CODE: 6TH EDITION (2017) <br />1. 3. GEOMETRIC CONTROL: <br />COMPONENT AND CLADDING PRESSURE ZONES <br />COMPONENTS AND CLADDING WIND PRESSURE CHART <br />COMPONENTS AND CLADDING <br />COMPONENTS AND CLADDING <br />ULTIMATE PRESSURE SCHEDULE <br />ULTIMATE PRESSURE SCHEDULE <br />WALLS, DOORS AND WIND❑WS <br />ROOFS <br />ENCLOSED BUILDING <br />ENCLOSED BUILDING <br />GCpi=+/- 0.18 <br />GCPI=+/- 0,18 <br />(+) INDICATES INWARD; (-) INDICATES <br />(+) INDICATES INWARD; (-) INDICATES OUTWARD <br />OUTWARD <br />NOT WITHIN 4' <br />NOT WITHIN 4' <br />EFFECTIVE AREA OF <br />WITHIN 4' OF <br />NOT WITHIN 4' <br />EFFECTIVE AREA OF <br />WITHIN 4' OF <br />OF CORNER BUT <br />OF CORNER, <br />COMPONENT <br />CORNER <br />OF CORNER <br />COMPONENT <br />CORNER <br />WITHIN 4' OF <br />EAVE OR <br />EAVE OR <br />TRANSITI❑N <br />TRANSITION <br />0 ,F, < "AREA' < 20 <br />+43,9 -58.8 <br />+43.9 -47.6 <br />OS F S.F. < "AREA' < 20 <br />+25.3 -103.4 <br />+25.3 -69.9 <br />+25.3 -26.8 <br />SF.20S,F, <br />< "AREA' < 30 <br />+42,0 -54.7 <br />+42.0 -45.8 <br />20S.F, < 'AREA" < 30 <br />+23.1 -96.7 <br />+23,1 -64,4 <br />+23.1 -25.7 <br />S,F, <br />S.F, <br />30 S,F, < 'AREA' < <br />+40,9 -52,5 <br />+40,9 -44.6 <br />30 S.F. < 'AREA' < 40 <br />-92.6 <br />+21.6 -61,0 <br />+21.6 -24.9 <br />40 S.F. <br />S.F.+21.6 <br />40 S.F. < 'AREA' < <br />+39,8 -51,0 <br />+39,8 -43,5 <br />40 S.F, < 'AREA' < 50 <br />+20,8 -90,0 <br />+20,8 -58.8 <br />+20,8 -24,6 <br />50 S,F, <br />S.F <br />50 S.F. < 'AREA" < <br />+39.4 -49,5 <br />+39;4 -43,2 <br />50 S.F, < 'AREA' < 75 <br />+20.1 -87,8 <br />+20,1 -56,9 <br />+20,1 -24,2 <br />75 S,F. <br />S F <br />75 S.F. < AREA < 100 <br />+38.3 -47,2 <br />+38.3 -42,0 <br />75 S,F, < AREA < 100 <br />+18.6 -83.7 <br />+18,6 -53,6 <br />+18.6 -23A <br />,F, S <br />S,F, <br />100 S.F. < "AREA' < <br />+37,2 -45.8 <br />+37.2 -40,9 <br />100 S.F. < 'AREA' < <br />+17.9 -81.1 <br />+17,9 -51,3 <br />+17,9 -23A <br />125 S.F. <br />125 S.F. <br />125 S,F, < 'AREA' < <br />+36.8 -44.3 <br />+36.8 -40.5 <br />125 S.F. < 'AREA' < <br />17,9 -81A <br />17.9 -5L3 <br />17.9 -23A <br />150 S,F. <br />150 S.F. <br />'AREA' > 150 S.F. <br />+36A -432 <br />i +36.1 -39.8 <br />'AREA' > 150 S.F. <br />+173 -81.1 1 <br />+17.9 -51,3 <br />1 +17.9 -23.1 <br />ALL BUILDING ELEMENTS EXPOSED TO WIND SHALL BE INSTALLED PER MANUFACTURER'S <br />NOTES; INSTRUCTIONS TO RESIST THE WIND PRESSURES INDICATED AND TO MEET OTHER CODE <br />REQUIREMENTS FOR AIR AND WATER INTRUSION, WIND LOADS ABOVE ARE ULTIMATE LOADS, USE <br />ULTIMATE WIND PRESSURE W/ ASCE7-10 LOAD C❑MBINATI❑NS, MULTIPLY LOADS BY 016 TO <br />❑BTAIN NOMINAL LOADS, <br />1. 3. 1. ELEVATIONS ARE BASED ON NATIONAL GEODETIC VERTICAL DATUM OF 1988 (NAVD <br />1988). SURVEY INFORMATION PROVIDED BY OWNER/CONTRACTOR. <br />1. 4. <br />SHOP DRAWINGS: <br />3. DESIGN METHOD <br />1. 4. 1. THERE SHALL NOT BE ANY DEVIATIONS FROM THESE DESIGN <br />PLANS BY OTHERS DURING <br />THE PREPARATION OF SHOP DRAWINGS WITHOUT WRITTEN <br />APPROVAL FROM THE ENGINEER <br />OF RECORD. <br />3. 1. LOAD FACTOR DESIGN: <br />1. 4. 2. ALL SHOP DRAWINGS ARE TO BE SUBMITTED TO THE ENGINEER OF RECORD PRIOR TO THE <br />COMMENCEMENT OF CONSTRUCTION. <br />3. 1. 1. THE LOAD FACTOR DESIGN METHOD WAS USED TO DESIGN <br />1. 4. 3. ALL ITEMS IDENTIFIED OR INTENDED TO BE DESIGNED BY <br />OTHERS REQUIRE SHOP <br />CAST -IN -PLACE CONCRETE SLABS, BEAMS, COLUMNS & FOOTINGS <br />DRAWINGS TO BE SIGNED AND SEALED AND SHALL INCLUDE ; DRAWINGS AND <br />CALCULATIONS, REACTIONS AND BEARING POINTS, BRACING REQUIREMENTS, LIFTING <br />3. 2. SERVICE LOAD DESIGN: <br />LOCATIONS, AND CONNECTIONS TO SUPPORTING TRUSS MEMBERS. <br />DESIGN <br />LOADS <br />3. 2. 1. THE SERVICE LOAD DESIGN METHOD WAS USED TO DESIGN <br />2, <br />MASONRY WALLS AND LINTELS <br />INTERIOR AND EXTERIOR WOOD FRAMING AND SHEATHING <br />STAIRS AND FLOOR FRAMING <br />ROOF FRAMING, SHEATHING AND UP LIFT <br />2.1. <br />DEAD LOADS <br />3.3. LOAD FACTORS AND COMBINATIONS: <br />2. 1. 1. UNIT WEIGHT OF SOIL, COMPACTED <br />120 PCF <br />2. 1. 2. UNIT WEIGHT OF REINFORCED CONCRETE <br />150 PCF <br />3. 3. 1. THE FOLLOWING LOAD COMBINATIONS WERE DESIGNED FOR <br />2. 1. 3. UNIT WEIGHT OF 8" C.M.U. BLOCK <br />55 PSF <br />TOTAL DL + FLOOR LL + ROOF LL <br />2. 1. 4. 1ST FLOOR SUPERIMPOSED LOAD <br />20 PSF <br />TOTAL DL + FLOOR LL + WL <br />2. 1. 5. UNIT WEIGHT OF 2x4 PARTITION WALLS <br />8 PSF <br />TOTAL DL + WL <br />2. 1. 6. UNIT WEIGHT OF 2x6 BEARING WALLS <br />12 PSF <br />2. 1. 7. 2ND FLOOR SELF WEIGHT : <br />8 PSF <br />3. 3. 2. IN THE CASE OF WIND LOADS, AN ALLOWABLE OVER STRESS OF 125% CAN BE <br />2. 1. 8. 2ND FLOOR SUPERIMPOSED LOAD <br />20 PSF <br />CONSIDERED. <br />2. 1. 9. ROOF SELF WEIGHT : <br />20 PSF <br />2. 1. 10. ROOF SUPERIMPOSED LOAD <br />20 PSF <br />3. 3. 3. ALL ROOF AND FLOOR TRUSSES SHALL BE DESIGNED TO RESIST THE WORST LOAD <br />2. 1. 11. FLOOR TRUSS <br />COMBINATION RESULTING IN THE MAXIMUM STRESSES PLACED ON THAT COMPONENT. BOTH <br />TOP CHORD MINIMUM <br />25 PSF <br />PARTIAL, FULL, AND ALTERNATING SPAN LOADING ARE TO BE CONSIDERED. <br />BOTTOM CHORD MINIMUM <br />2. 1. 12, ROOF TRUSS <br />5 PSF <br />3.4. DESIGN ASSUMPTIONS: <br />TOP CHORD MINIMUM <br />15 PSF <br />BOTTOM CHORD MINIMUM <br />10 PSF <br />2.2. <br />LIVE LOADS: <br />3. 4. 1. FOUNDATIONS ARE DESIGNED BASED ON A PRESUMPTIVE BEARING CAPACITY OF 2000 PSF <br />ON UNDISTURBED SOIL OR ROCK. A REGISTERED GEOTECHNICAL ENGINEER SHALL VERIFY <br />ACTUAL CONDITIONS PRIOR TO PLACEMENT OF THE FOOTING. IF THE FOUNDATION IS ON <br />PREPARED FILL, THE REGISTERED GEOTECHNICAL ENGINEER SHALL VERIFY SUITABILITY OF <br />2. 2. 1. SIDEWALK AND DRIVEWAY LOAD <br />200 PSF <br />FILL FOR USE AND ITS FOUNDATION BEARING CAPACITY. <br />2. 2. 2. GARAGE LOADS <br />50 PSF <br />2. 2. 3. CORRIDORS AND BATHROOMS <br />100 PSF <br />3. 4. 2. ALL FOUNDATIONS ARE CENTERED UNDER SUPPORTED COLUMNS AND WALLS UNLESS <br />2. 2. 4. PARTITIONED ROOMS <br />100 PSF <br />SHOWN OTHERWISE IN THE DESIGN PLANS. <br />2. 2. 5. BALCONY AND DECKS <br />40 PSF <br />2. 2. 6. STAIRWAYS AND LANDINGS : <br />2. 2. 7. ROOF: <br />120 PSF <br />20 PSF <br />4 MATERIALS <br />2.4. <br />WIND LOADS: <br />, <br />4. 1. REINFORCING STEEL: <br />2. 4. 1. WIND DESIGN TO BE CONDUCTED IN ACCORDANCE ASCE 7-10, <br />142 MPH WIND ULTIMATE, 109 MPH NOMINAL. <br />2. 5. <br />THERMAL FORCES: <br />4 1 1 REINFORCING STEEL SHALL BE ASTM A615 GRADE 60, fly = 40 Ksi UNLESS OTHERWISE <br />4. 1. 2. REINFORCING LAP SPLICES SHALL BE 48 BAR DIAMETERS IN LENGTH UNLESS OTHERWISE <br />2. 5. 1. SEASONAL VARIATION FOR DESIGN AND CONSTRUCTION <br />NOTED. <br />MEDIAN TEMPERATURE 70 F <br />TEMPERATURE RISE 25 F <br />4. 1. 3. ALL DIMENSIONS PERTAINING TO THE LOCATION OF REINFORCING ARE TO THE CENTERLINE <br />TEMPERATURE FALL 35 F <br />OF EACH BAR EXCEPT WHERE THE COVER DIMENSION IS SHOWN TO THE FACE OF THE <br />CONCRETE. <br />2. 5. 2. MEDIAN RELATIVE HUMIDITY 75% <br />4. 1. 4. REINFORCING DETAIL DIMENSIONS ARE OUT TO OUT OF BARS. <br />2. 6. <br />CREEP AND SHRINKAGE: <br />4. 1, 5. REINFORCING MECHANICAL COUPLERS ARE TO DEVELOP 125 % OF THE REQUIRED YIELD <br />STRENGTH OF THE BAR AND ARE TO BE APPROVED BY THE ENGINEER OF RECORD. <br />2. 6. 1. ALL LOSSES IN ACCORDANCE WITH ACI 318, LATEST EDITION <br />2. 7. SEISMIC LOADS: <br />2. 7. 1. SEISMIC PERFORMANCE CATEGORY "A" <br />2. 8. DESIGN WIND SPEEDS: <br />2. 8. 1. COMPONENTS AND CLADDING NET PRESSURE COEFFICIENTS ARE IN ACCORDANCE WITH <br />TABLE 1609.6.2 (1) AND TABLE 1609.6.2 (2). <br />2. 8. 2. GARAGE DOOR AND ROLLING DOOR WIND LOADS FOR A BUILDING WITH A MEAN ROOF <br />HEIGHT OF 30 FEET LOCATED IN EXPOSURE B, TABLE 1609.7 (1). <br />2. 8. 3• ADJUSTMENT FACTOR FOR BUILDING HEIGHT AND EXPOSURE, TABLE 1609.7 (2). <br />2017 FLORIDA BUILDING CODE, 6TH EDITION ASCE 7 <br />BASIC WIND SPEED (3 SEC GUSTS) = V (ult) =140 MPH, V(osd) = 108 MPH <br />TYPE OF DESIGN: ENCLOSED <br />COMPONENTS AND CLADDING: SEE INDIVIDUAL ITEMS <br />ROOF ANGLE: WORST CASE <br />DISCLAIMER <br />THE CLIENT UNDERSTANDS THAT THERE IS NO LIABILITY INSURANCE OUTSIDE CONTRACT LIMITS THAT <br />CAN BE CLAIMED PER THIS PROJECT AND AGREES TO HOLD HARMLESS, INDEMNIFY, AND DEFEND THE <br />ARCHITECT FROM ALL CLAIMS, LOSSES AND EXPENSES, INCLUDING REASONABLE ATTORNEY FEES <br />ARISING OUT OF OR RESULTING FROM THE DRAWINGS. IN THE EVENT ERRORS OCCUR, THE ARCHITECT <br />WILL NOT BE LIABLE FOR COST OF REPAIRS OR DELAY TO THE CONSTRUCTION FOR THIS PROJECT. <br />4. 1. 6. DESIGN COVER REQUIREMENTS : <br />C-1-P CONCRETE FORMED AGAINST EARTH 3" <br />C-I-P CONCRETE EXPOSED TO EXTERIOR 2" <br />C-I-P CONCRETE NOT EXPOSED 1 1 /2" <br />GROUT FILLED MASONRY : 3/4" <br />PRE STRESSED CONCRETE LINTELS 1 1/2" <br />PRE CAST GROUT FILLED LINTELS 1 1 /2" <br />4. 2. CONCRETE: <br />4. 2. 1 <br />4. 2. 2. <br />4. 2. 3. <br />4. 2. 4. <br />4. 2. 5. <br />C-I-P CONCRETE <br />C-I-P GROUT <br />PRE CAST CONCRETE LINTELS <br />PRE STRESSED CONCRETE LINTELS <br />MIN. 28 DAY <br />DESIGN (f'c) <br />MODULUS OF <br />ELASTICITY <br />DESIGN (E) <br />3,000 Psi <br />3,122 Ksi <br />2,000 Psi <br />2,500 Ksi <br />3,000 Psi <br />4,000 Ksi <br />5,000 Psi <br />3,200 Ksi <br />CONCRETE SHALL CONSIST OF 1" MAXIMUM AGGREGATE CONCRETE MIX WITH SLUMP <br />BETWEEN 6" AND 7" AT TIME OF PLACEMENT. SEE ACI SPECIFICATIONS FOR ADDITIONAL <br />CRITERIA. <br />GROUT SHALL CONSIST OF PEA ROCK (3/8" MAXIMUM AGGREGATE) CONCRETE MIX WITH <br />SLUMP BETWEEN 8" AND 10" AT TIME OF PLACEMENT. SEE ACI, ASTM SPECIFICATIONS <br />FOR ADDITIONAL CRITERIA. <br />CONSTRUCTION JOINTS ARE TO BE PROVIDED IN ACCORDANCE WITH THE DESIGN CODES <br />AND GUIDELINES AT THE ENGINEERS DIRECTION. <br />METHOD OF CONCRETE FORMING, PLACEMENT AND CURING SHALL BE CONDUCTED IN <br />ACCORDANCE WITH THE ACI, ASTM SPECIFICATIONS AS STATED. <br />4. 3. STRUCTURAL LUMBER WIND INFORMATION <br />BUILDING RISK CATEGORY: <br />4. 4. 1. <br />INTERIOR FRAMING 2x(4) <br />EXTERIOR FRAMING 2x(6 AND 8) <br />FLOOR FRAMING 2x(8 AND 10) <br />MAXIMUM DESIGN VALUES <br />MODULUS OF <br />ELASTICITY <br />(E) <br />BENDING <br />f'b <br />TENSION <br />ft <br />SHEAR <br />TV) <br />1,500 Psi <br />825 Psi <br />90 Psi <br />1,600 Ksi <br />1,200 Psi <br />650 Psi <br />90 Psi <br />1,600 Ksi <br />1,300 Psi <br />725 Psi <br />90 Psi <br />1,700 Ksi <br />BASIS OF DESIGN WIND SPEED 138 MPH - 3 SECOND GUST <br />EXPOSURE CATEGORY (A, B, OR C): "B" <br />WINDBORNE DEBRIS REGION REQUIREMENTS: YES <br />A. PLYWOOD SHUTTERS IN ACCORDANCE w/ 1626 OF F.B.C. <br />B. SAFETY GLASS IN ACCORDANCE w/ 1626 OF F.B.C. <br />C. ROLL DOWN SHUTTERS IN ACCORDANCE w/ 1626 OF F.B.C. <br />D. OPEN DESIGN N/A <br />E NOT RE UURED Q N <br />/A <br />INTERNAL PRESSURE COEFFICIENT: ♦/- 0.18 <br />TABLE VALUES ARE MINIMUMS AND ARE BASED ON SOUTHERN PINE No. 2 GRADE. <br />1. VALLEY LININGS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURES INSTALLATION. <br />4. 4. 2. <br />ALL PLYWOOD USED FOR EXTERIOR APPLICATIONS SHALL CONFORM TO VOLUNTARY <br />INTSRUCTIONS BEFORE APPLYING CONC. ROOF TILES VALLEY LININGS OF THE FOLLOWING <br />PRODUCT STANDARD PS 1-83 AND SHALL BE APA RATED SHEATHING EXP 3. <br />TYPES SHALL BE PERMITTED. <br />4. 4. 3, <br />ALL PLYWOOD USED FOR INTERIOR APPLICATIONS SUCH AS SUB FLOORING AND SHEAR <br />2. FOR OPEN VALLEYS (VALLEY LINING EXPOSED) LINED WITH METAL, THE VALLEY LINING <br />WALLS SHALL CONFORM TO VOLUNTARY PRODUCT STANDARD PS 1-83 AND SHALL BE APA <br />SHALL BE AT LEAST 16 INCHES (406 MM) WIDE AND OF ANY OF THE <br />RATED SHEATHING EXP 1 OR 2. <br />CORROSION -RESISTANT METALS. , <br />4. 4. 4. <br />IF OSB BOARD IS TO BE USED IN PLACE OF PLYWOOD IS TO HAVE SIMILAR SECTION <br />3. FOR OPEN VALLEYS (VALLEY LINING IF TWO PILES OF MINERAL SURFACES ROLL ROOFING <br />PROPERTIES. <br />SHALL BE PERMITTED. THE BOTTOM LAYER SHALL BE 18 INCHES (457 MM) AND THE TOP <br />4. 4. 5. <br />ONLY STRUCTURAL LUMBER TO BE USED FOR AN EXTERIOR APPLICATION AND IN CONTACT <br />LAYER A MINIMUM OF 36 INCHES (914 MM) WIDE. <br />WITH CONCRETE IS TO RECEIVE A STANDARD GRADE PRESSURE TREATING. <br />4. FOR CLOSED VALLEYS (VALLEY COVERED WITH SHINGLES), VALLEY LININGS SHALL <br />4. 4. 6. <br />PRESSURE TREATED STRUCTURAL LUMBER IS NOT TO BE USED FOR ANY INTERIOR <br />BE ONE OF THE FOLLOWING: <br />FRAMING. <br />A. BOTH TYPES 1 AND 2 ABOVE COMBINED <br />4.4. FASTENERS AND TIE DOWNS: <br />B. ONE PLY OF SMOOTH ROLL ROOFING AT LEAST 36 INCHES WIDE (914 MM) AND <br />COMPLYING WITH ASTM D 224. <br />4. 5. 1. <br />FASTENERS AND TIE DOWNS SHALL CONSIST OF BUT ARE NOT LIMITED TO : <br />C. SPECIALITY UNDERLAYMENT AT LEAST 36 INCHES (914 MM) WIDE AND <br />COMPLYING WITH ASTM D 1470. <br />SHAPES, ANGLES, CHANNELS : ASTM A36 Fy = 36 Ksi <br />ROUND METAL PIPE : ASTM A53, GRADE B Fy = 35 Ksi <br />WINDOWS AND DOORS. <br />SQUARE METAL TUBING • ASTM A500 GRADE B Fy = 46Ksi <br />HIGH STRENGTH BOLTS : ASTM A325 <br />MACHINE BOLTS : GALVANIZED ASTM A307 <br />4. 5. 2. SHEET METAL ACCESSORIES SHALL CONFORM TO : ASTM A446 OR ASTM A526 Fy = 33 <br />Ksi WITH G90 GALVANIZED COATING IN ACCORDANCE WITH ASTM A525. <br />4. 5. 3. NAILS SHALL CONSIST OF : COMMON WIRE NAILS WITH MINIMUM DIAMETER AS FOLLOWS <br />8d = 0.131 ", 10d = 0.148", 16d = 0.162". <br />4. 5. 4. ALL FASTENERS AND TIE DOWNS EMBEDDED IN CONCRETE OR USED IN AN EXTERIOR <br />APPLICATION ARE TO RECEIVE AN ANTI -CORROSIVE COATING PRIOR TO <br />INSTALLATION. <br />4. 5. 5. ALL FASTENERS AND TIE DOWNS ARE TO PROVIDE THE UPLIFT CAPACITY CALLED <br />FOR IN THE PLANS AS A MINIMUM. <br />4. 5. 6. CONCRETE EMBEDDED V BOLTS USED FOR UPLIFT ARE TO BE WET SET PRIOR TO <br />INITIAL SET OF THE CONCRETE, SPACING AND ALIGNMENT ARE TO BE IN ACCORDANCE <br />WITH THE DESIGN PLANS. <br />A <br />90° HOOK SHOWN <br />STANDARD HOOK FOR <br />REINFORCING BAR <br />MIN. up <br />_l <br />LAP SPLICE <br />RECOMMENDED END HOOKS AND LAP LENGTHS <br />BAR <br />180' HOOK <br />90' HOOK <br />HOOK <br />LAP <br />SIZE <br />A <br />A <br />R <br />Lb <br />#3 <br />5" <br />6" <br />1" <br />18" <br />#4 <br />6" <br />8" <br />1-1/2" <br />24" <br />#5 <br />7" <br />loll <br />2" <br />30" <br />#6 <br />8" <br />12" <br />2-1/4" <br />36" <br />#7 <br />10" <br />14" <br />2-1/2" <br />42" <br />#8 <br />11" <br />16" <br />3" <br />48" <br />#9 <br />15" <br />19" <br />4-3/4" <br />55" <br />#10 <br />17" <br />22" <br />5-1/2" <br />61" <br />STEEL LAP AND BEND DTL. <br />N TS <br />LINTEL TYPE - A <:.4 LINTEL TYPE - B <br />SPAN 3'-0" THRU 6'-0" SPAN 6'-0" THRU 18'-0" <br />LINE OF <br />REINF. <br />STL. <br />8" MIN. BEARING (TYP.) <br />LINTEL SCHEDULE <br />LINTEL TYPE <br />BAR SIZE <br />BAR QNTY. <br />LINTEL SIZE <br />TYPE - A <br />TYPE - B <br /># 5 <br /># 5 <br />2 <br />4 <br />8" x 8" <br />8" x 16" <br />8" MIN. BEARING (TYP.) <br />J <br />LINTEL SCHEDULE & REINF. <br />NTS <br />GENERAL NOTES <br />1. CONSTRUCTION SHALL COMPLY WITH ALL LOCAL BUILDING CODES <br />2. PRE -ENGINEERING ROOF TRUSSES SHALL BE DESIGNED TO MEET 145 MPH WIND UPLIFT <br />CRITERIA. WIND UPLIFT CRITERIA BY A FLORIDA REGISTERED ENGINEER. <br />3. CONCRETE SHALL REACH DESIGN STRENGTH WITHIN 28 DAYS OF PLACEMENT. SLAB ON GRADE <br />CONCRETE SHALL BE CHEMICALLY CURED WITH MATERIAL COMPATIBLE WITH FLOORING ADHESIVE. <br />4. ALL STRUCTURAL LUMBER SHALL BE NO.-1 SOUTHERN YELLOW PINE KILN DRIED. ALL WD. IN <br />CONTACT WITH CONC. SHALL BE TREATED WITH WOOD PRESERVATIVE, ALL DIMENSIONAL LUMBER <br />EXPOSED TO WEATHER SHALL BE PRESSURE TREATED. <br />5. ROOF DECKING SHALL BE INSTALLED IN T & G CONFIGURATION & SHALL BE NAILED @ 6" O.C. <br />© EDGES & 12" O.C. INTERMEDIATE AREA NAILS SHALL BE 10d COMMON DEFORMED SHANK. <br />PERIMETER EDGE FLASHING SHALL BE PAINTED GALV. 20 GA MTL. MIN. LAP @ ROOF SHALL BE <br />3" - NAILED © 6" O.C. & SET IN MASTIC. <br />6. DECK DESIGNS TO COMPLY WITH FBC, SECTION R502, WOOD FLOOR FRAMING, R502.1.4 DECKS: <br />WHERE SUPPORTED BY ATTACHMENT TO AN EXTERIOR WALL, DECKS SHALL BE POSITIVELY <br />ANCHORED TO THE PRIMARY STRUCTURE AND DESIGNED FOR BOTH VERTICAL AND LATERAL <br />LOADS AS APPLICABLE. SUCH ATTACHMENT SHALL NOT BE ACCOMPLISHED BY THE USE OF <br />TOENAILS OR NAILS SUBJECT TO WITHDRAWAL. <br />7. HAZARDOUS GLAZING TO COMPLY WITH FBC, SECTION R308, GLAZING, R308.1 IDENTIFICATION: <br />EACH PANE SHALL BEAR THE MANUFACTURER'S LABEL DESIGNATING THE TYPE AND THICKNESS <br />OF GLASS OR GLAZING MATERIAL. EXCEPT AS INDICATED IN SECTION R308.1.1 EACH PANE OF <br />GLAZING INSTALLED IN HAZARDOUS LOCATIONS AS DEFINED IN SECTION R308.4 SHALL BE <br />PROVIDED WITH A MANUFACTURER'S OR INSTALLER'S LABEL, DESIGNATING THE TYPE OF GLASS <br />AND THE SAFETY GLAZING STANDARD WITH WHICH IT COMPLIES, WHICH IS VISIBLE IN THE FINAL <br />INSTALLATION. THE SAFETY GLAZING LABEL SHALL BE ACID ETCHED, SANDBLASTED, <br />CERAMIC -FIRED, LASER ETCHED, EMBOSSED, OR BE OF A TYPE WHICH ONCE APPLIED CANNOT <br />BE REMOVED WITHOUT BEING DESTROYED. LAMINATE GLASS, OTHER THAN USED FOR SAFETY <br />GLAZING, SHALL BE PERMANENTLY IDENTIFIED AS PER THIS SECTION, DESIGNATING LAMINATOR, <br />OVERALL GLASS THICKNESS AND TRADE NAME OF INTERLAYER. <br />1. EXTERIOR WINDOWS AND GLASS DOORS SHALL BE TESTED PRIOR TO INSTALLATION IN <br />ACCORDANCE WITH ANSI/AMMA/NWDA 101 / IS2 STANDARD AND BEAR AN AMMA OR WDMA <br />LABEL IDENTIFYING THE MANUFACTURER, PERFORMANCE CHARACTERISTICS AND APPROVED <br />PRODUCT TESTING ENTITY, IN ACCORDANCE WITH CHAPTER 17 OF THE FLORIDA BUILDING <br />CODE. <br />2, ALL DOORS & WINDOWS SHALL COMPLY WITH F.B.C. WIND LOAD <br />REQUIREMENT - 142 MPH <br />3. ALL GLASS DOORS TO BE TEMPERED GLAZING. <br />4. ANY GLAZING WITHIN 36" HORIZONTALLY AND BELOW 60" OF THE STANDING <br />SURFACE OF A BATHTUB, SHOWER, SPA, ETC., SHALL BE SAFETY GLAZED. <br />5. PERIMETER EXTERIOR SEALANT TO BE DOW 795 SILICONE SEALANT OR APPROVED EQUAL; <br />VERIFY COMPATIBILTIY OF SEALANT WIHT ADJACENT SUBSTRATES PRIOR TO INSTALLATION <br />6. ALL DOORS AND WINDOW TO FBC NOA COMPLIANT FOR WIND LOAD INDICATED. <br />FASTNER SPACING AND SIZE SHALL BE IN ACCORDANCE WITH THE MFG.'S FBC APPROVED NOA. <br />7. WINDOW AND DOOR FRAMES SHALL BE PAINTED WITH PPG KYNAR PAINT SYSTEM COMPLYING WITH <br />AAMA 2605, OR APPROVED EQUAL. COLOR TO BE BONE WHITE OR BY OWNER. <br />WINDOW ANCHORAGE REQUIREMENTS: <br />1. EXTERIOR WINDOWS AND DOORS - WHERE BUCK THICKNESS IS 1-1/2 INCHES OR LESS, THE <br />BUCK SHALL BE ATTACHED WITH FASTENERS THROUGH TO JAMB AND SECURED DIRECTLY <br />TO THE STRUCTURE; MINIMUM EMBEDMENT INTO STRUCTURE IS 1-3/4", OR AS REQUIRED BY <br />MFG.'S FBC APPROVED NOA CRITERIA FOR THE WIND LOADS INDICATED AND AS REQUIRED <br />BY LOCAL BUILDING CODES. <br />TYPE OF ROOF SYSTEM: <br />MANUFACTURER: OWEN CORNING -GAF OR EQUAL <br />MANUFACTURER NO.: TIMBERLINE HD UL 790 CLASS A <br />FASTENING REQUIREMENTS: PER MANF. REQUIREMENTS <br />WIND RESISTANCE RATING: 130-MPH or AS SPECIFIED <br />FLASHING REQUIREMENTS: WEATHER LOCK -G ( MIN.) 55 mil. THCK. <br />THIS PRODUCT HAS BEEN REVIEWED BY THE ARCHITECT IN ACCORDANCE WITH THE <br />2017 FLORIDA BUILDING CODE (F.B.C.), 6th EDITION. BASED ON THE MANUF.'S <br />PUBLISHED LITERATURE DATED 1-2 / 12 /2017 , AND IF PROPERLY INSTALLED, THE <br />ROOFING MATERIALS SHALL COMPLY WITH THE F.B.C. WIND CRITERIA REQUIRED FOR THE <br />BUILDING SITE. ROOF SYSTEM INSTALLATION TO BE COMPLIANT WITH FBC-APPROVED NOA. <br />TERMITE PROTECTION TO COMPLY <br />WITH FBC, SECTION R318: <br />1. A WEATHER RESISTANT JOB SITE POSTING BOARD SHALL BE PROVIDED TO RECEIVE <br />DUPLICATE TREATMENT CERTIFICATES TO BE POSTED AFTER EACH REQUIRED PROTECTIVE <br />TREATMENT IS COMPLETED. A COPY OF THE CERTIFICATE IS TO BE PROVIDED FOR THE <br />PERSON THE PERMIT IS ISSUED TO, AND ANOTHER COPY FOR THE BUILDING PERMIT FILES. <br />2. TO ESTABLISH A VERIFIABLE RECORD OF PROTECTIVE TREATMENT, THE TERMITE <br />CERTIFICATE SHALL 1) INDICATE THE PRODUCT USED, 2) IDENTITY OF THE APPLICATOR, 3) <br />TIME AND DATE OF THE TREATMENT, 4) SITE LOCATION, 5) AREA TREATED, 6) CHEMICAL <br />USED, AND 7) PERCENT CONCENTRATION AND NUMBER OF GALLONS USED. <br />3, IF THE SOIL CHEMICAL BARRIER METHOD FOR TERMITE PREVENTION IS USED, FINAL <br />EXTERIOR TREATMENT SHALL BE COMPLETED PRIOR TO FINAL BUILDING APPROVAL. <br />4. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR <br />RE -INSPECTION AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE SIGN <br />SHALL BE POSTED NEAR THE WATER HEATER OR ELECTRIC PANEL. <br />5. INITIAL TERMITE CHEMICAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND <br />BACKFILL IS COMPLETE. <br />6. SOIL DISTURBED AFTER THE INITIAL TERMITE CHEMICAL TREATMENT SHALL BE <br />RETREATED INCLUDING SPACES BOXED OR FORMED. BOXED AREAS IN CONCRETE <br />FLOORS FOR SUBSEQUENT INSTALLATION OF TRAPS, ETC., SHALL BE MADE WITH PERMANENT <br />METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF A SIZE AND DEPTH THAT WILL <br />ELIMINATE THE DISTURBANCE OF SOIL AFTER THE INITIAL TREATMENT. <br />7. ALL VAPOR BARRIER JOINTS MUST BE TAPED, CONTINUOUS WITH DUCT TAPE, AND VAPOR <br />BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL DILUTION. IF RAINFALL <br />OCCURS BEFORE VAPOR BARRIER PLACEMENT, RE -TREATMENT IS REQUIRED. <br />8. CONCRETE OVERPOUR AND MORTAR ALONG THE FOUNDATION PERIMETER MUST BE <br />REMOVED BEFORE EXTERIOR SOIL TERMITE CHEMICAL TREATMENT IS APPLIED. TERMITE <br />CHEMICAL SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR <br />GRADE WITHIN V-0" OF THE STRUCTURE SIDEWALLS. <br />9. AN EXTERIOR VERTICAL TERMITE CHEMICAL BARRIER MUST BE INSTALLED AFTER <br />CONSTRUCTION IS COMPLETE INCLUDING LANDSCAPING AND IRRIGATION. ANY SOIL <br />DISTURBED AFTER THE VERTICAL BARRIER IS APPLIED, SHALL BE RETREATED. <br />10, ALL BUILDINGS ARE REQUIRED TO HAVE PRE -CONSTRUCTION TERMITE CHEMICAL <br />TREATMENT. <br />ll. A CERTIFICATE OF COMPLIANCE MUST BE PREPARED BY A LICENSED TERMITE <br />TREATMENT APPLICATOR AND IS TO BE ISSUED TO THE BUILDING DEPARTMENT BEFORE A <br />CERTIFICATE OF OCCUPANCY WILL BE ISSUED. <br />THE CERTIFICATE OF COMPLIANCE SHALL STATE, "THE BUILDING HAS RECEIVED A <br />COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. THE TREATMENT <br />IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA DEPARTMENT OF <br />AGRICULTURE AND CONSUMER SERVICES." <br />12, AFTER ALL WORK IS COMPLETED, LOOSE WOOD AND FILL MUST BE REMOVED FROM <br />BELOW AND WITHIN 1'-O" OF THE BUILDING. THIS INCLUDES ALL GRADE STAKES, TUB TRAP <br />BOXES, FORMS, SHORING OR OTHER CELLULOSE CONTAINING MATERIAL. <br />13.NO WOOD VEGETATION STUMPS, CARDBOARD, TRASH, ETC., SHALL BE BURIED WITHIN <br />15'-0" OF THE BUILDING. <br />14. CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 1'-O" AWAY FROM <br />THE BUILDING SIDEWALLS, OR PRECAST SPLASH BLOCKS MUST BE INSTALLED AS <br />INDICATED ON THE CONTRACRT DOCUMENTS. <br />15.IRRIGATION/SPRINKLER SYSTEMS INCLUDING ALL RISERS AND SPRAY HEADS SHALL NOT <br />BE INSTALLED WITHIN l'-O" OF THE BUILDING SIDEWALLS. <br />I HERE CERTIFY THAT I HAVE REVIEWED THE ATTACHED <br />DESIGN AND FOUND IT TO BE IN COMPLIANCE WITH 2O17 <br />FLORIDA BUILDING CODE, 6th EDITION, RESIDENTIAL PER <br />THE DATE OF THESE DOCUMENTS. <br />05/07 /2019 <br />JEREL MCCANTS, AIA AR94378 <br />(i L-) <br />z I` <br />0) <br />_ r•I Lo <br />I <br />c: <br />C <br />UW <br />H- W C7 <br />co <br />Z) T <br />U Z 00 <br />a) <br />oC W <br />Q > Lr) <br />V) Q O <br />�ZF-mM <br />< 'll I <br />i <br />c� <br />U ci � p <br />Q Q C) <br />N <br />W <br />W N N <br />c <br />Q <br />n r-1 <br />N <br />z <br />F� <br />U) <br />W <br />`N <br />ql�r <br />L0 <br />o <br />M <br />cy') <br />LL <br />W <br />ZU) <br />W.j <br />O <br />Q <br />�--' <br />-O� <br />= <br />W <br />M <br />WM <br />�- <br />W <br />Lo <br />W <br />N <br />ISSUE RECORD <br />REVISION NO./DATE: <br />DESCRIPTION: <br />GENERAL NOTES <br />JOB No.: 19-023 <br />DWN BY: MA <br />CHK BY: JLM <br />DATE ISSUED: 05.07.19 <br />SHEET NO: <br />GN <br />