LIGHT FIXTURE SCHEDULE <br />LAMPS <br />TYPE <br />MANUFACTURER CATALOG NUMBER <br />VOLTS <br />MOUNTING <br />COMMENTS <br />I <br />QTY <br />WATTS/TYPE <br />CREE LIGHTING CR22-32L; 35WLED; 50K <br />2X2 LED LIGHT FIXTURE, COORDINATE <br />FINAL LIGHTING SELECTION WITH <br />APPROVED EQUAL FROM TAMPA BAY LIGHTING <br />35W <br />GRID <br />OWNER. <br />Al <br />_ <br />LED <br />120V <br />CEILING <br />APPROVED EQUAL FROM SESCO LIGHTING <br />APPROVED EQUAL FROM WESTERN FLORIDA LIGHTING <br />CREE LIGHTING <br />2X2 LED LIGHT FIXTURE, COORDINATE <br />BACK UP <br />FINAL LIGHTING SELECTION WITH <br />APPROVED EQUAL FROM TAMPA BAY LIGHTING <br />35W <br />GRID <br />OWNER. WITH EMERGENCY BATTERY <br />Al/EM <br />_ <br />LED <br />120V <br />CEILING <br />BACK UP. <br />APPROVED EQUAL FROM SESCO LIGHTING <br />APPROVED EQUAL FROM WESTERN FLORIDA LIGHTING <br />LITHONIA <br />72TL4 2'X4' LED <br />2X4 LED LIGHT FIXTURE, COORDINATE <br />FINAL LIGHTING SELECTION WITH <br />APPROVED EQUAL FROM TAMPA BAY LIGHTING <br />44W <br />GRID <br />OWNER. <br />B <br />- <br />LED <br />120V <br />CEILING <br />APPROVED EQUAL FROM SESCO LIGHTING <br />APPROVED EQUAL FROM WESTERN FLORIDA LIGHTING <br />LITHONIA <br />7BACKUP <br />2X4 LED LIGHT FIXTURE, COORDINATE <br />FINAL LIGHTING SELECTION WITH <br />APPROVED EQUAL FROM TAMPA BAY LIGHTING <br />44W <br />GRID <br />OWNER. WITH EMERGENCY BATTERY <br />B/EM <br />_ <br />LED <br />120V <br />CEILING <br />BACK UP. <br />APPROVED EQUAL FROM SESCO LIGHTING <br />APPROVED EQUAL FROM WESTERN FLORIDA LIGHTING <br />LITHONIA <br />LITHONIA <br />WF6-LED-50K-90CRI-MW <br />7W <br />6" LED RECESSED CAN LIGHT, <br />COORDINATE FINAL LIGHTING <br />APPROVED EQUAL FROM TAMPA BAY LIGHTING <br />14W <br />SELECTION WITH OWNER. <br />C <br />LED <br />120V <br />RECESSED <br />APPROVED EQUAL FROM SESCO LIGHTING <br />APPROVED EQUAL FROM WESTERN FLORIDA LIGHTING <br />MACRO AIR <br />CEILING FAN, COORDINATE FINAL <br />COLOR BLACK <br />SELECTION WITH OWNER. <br />APPROVED EQUAL FROM TAMPA BAY LIGHTING <br />350W <br />CEILING <br />F <br />- <br />LED <br />120V <br />FAN <br />APPROVED EQUAL FROM SESCO LIGHTING <br />APPROVED EQUAL FROM WESTERN FLORIDA LIGHTING <br />LITHONIA <br />ELM2L <br />120V OR 277V AC. EMERGENCY UNIT <br />PROVIDED WITH TEST SWITCH, STATUS <br />APPROVED EQUAL FROM TAMPA BAY LIGHTING <br />120/ <br />WALL <br />INDICATOR AND RECHARGEABLE <br />EL <br />2 <br />1.8W/LED <br />277V <br />OR <br />BATTERY. MAINTENANCE -FREE <br />APPROVED EQUAL FROM SESCO LIGHTING <br />CEILING <br />NICKEL -CADMIUM BATTERY PROVIDES <br />APPROVED EQUAL FROM WESTERN FLORIDA LIGHTING <br />90 MINUTES OF EMERGENCY POWER. <br />LITHONIA <br />EXR LED EL M6 <br />EXIT SIGN WITH RED LETTERS. WHITE <br />CEILING <br />THERMOPLASTIC HOUSING. <br />APPROVED EQUAL FROM TAMPA BAY LIGHTING <br />120/ <br />OR <br />MAINTENANCE -FREE NI -CAD BATTERY <br />EX <br />- <br />2W/LED <br />277V <br />WALL <br />PROVIDES 90 MINUTES OF <br />APPROVED EQUAL FROM SESCO LIGHTING <br />MOUNT <br />EMERGENCY POWER. <br />APPROVED EQUAL FROM WESTERN FLORIDA LIGHTING <br />LITHONIA <br />ECR LED HO M6 <br />RED LETTERS, DUAL -VOLTAGE INPUT <br />120V OR 277V AC; 9.6V OUTPUT. <br />APPROVED EQUAL FROM TAMPA BAY LIGHTING <br />120/ <br />NICKEL -CADMIUM BATTERY PROVIDES <br />EXL <br />2 <br />3.8WlLED <br />277V <br />CEILING <br />90 MINUTES OF EMERGENCY POWER. <br />APPROVED EQUAL FROM SESCO LIGHTING <br />HIGH OUTPUT (HO) OPTION POWERS UP <br />APPROVED EQUAL FROM WESTERN FLORIDA LIGHTING <br />TO 2 LED REMOTE LAMPS. <br />NOTES: <br />1. SUBSTITUTIONS WILL NOT BE PERMITTED WITHOUT APPROVAL FROM THE ENGINEER, FOURTEEN DAYS PRIOR TO BID DATE. <br />2. VERIFY LIGHTING FIXTURE COLOR/FINISH WITH ARCHITECT PRIOR TO ORDERING. <br />3. ADJUST MOUNTING HEIGHTS/LOCATIONS TO SUIT FIELD CONDITIONS. <br />4. (2) LAMPS TO BE WIRED IN PARALLEL FOR EMERGENCY BALLAST. <br />DISCONNECT SCHEDULE <br />D/C # <br />SIZE <br />POLES <br />PHASE <br />NEMA <br />FUSE <br />VOLT. <br />SERVES <br />COMMENTS <br />D-1 <br />60A <br />3 <br />3 <br />3R <br />NON-F <br />208 <br />RTU-1 <br />MOUNT ON UNIT <br />D-2 <br />60A <br />3 <br />3 <br />3R <br />NON-F <br />208 <br />RTU-2 <br />MOUNT ON UNIT <br />D-3 <br />30A <br />3 <br />3 <br />3R <br />NON-F <br />208 <br />KSF-1 <br />MOUNT ON UNIT <br />D-4 <br />30A <br />3 <br />3 <br />3R <br />NON-F <br />208 <br />KEF-1 <br />MOUNT ON UNIT <br />D-5 <br />30A <br />3 <br />3 <br />3R <br />NON-F <br />208 <br />KEF-2 <br />MOUNT ON UNIT <br />D-6 <br />400A <br />3 <br />3 <br />3R <br />400A <br />208 <br />MAIN <br />MOUNT ON WALL <br />NOTES <br />1. <br />VERIFY FUSE SIZES FOR ACTUAL EQUIPMENT SUBMITTED. <br />2. <br />FUSES SHALL BE DUAL ELEMENT, TIME DELAY, 100,000 AIC MININUM. <br />3. <br />FINAL CONNECTIONS TO MECHANICAL EQUIPMENT FROM DISCONNECT SHALL BE FLEX. FLEX <br />SHALL BE WATERTIGHT AT EXTERIOR OR WET LOCATIONS. <br />ADDITIONAL POLE TO DISCONNECT NEUTRAL SHALL BE PROVIDED WHERE REQUIRED. <br />L4. <br />5. <br />ALL DISCONNECTS SHALL HAVE LOCKED OFF PROVISION. <br />SPECIAL INFORMATIONAL NOTE: <br />THIS DRAWING PREPARED FOR TENANT IMPROVEMENTS TO AN <br />EXISTING BUILDING OR BUILDING CONSTRUCTED BY OTHERS <br />IT IS UNDERSTOOD THAT ANY WARRANTY INFORMATION <br />CONCERNING EQUIPMENT INSTALLED MUST BE FORWARDED TO <br />THE OWNER AND THAT ANY AND ALL CONTRACTORS SHALL <br />GUARANTEE THEIR WORK FOR A PERIOD OF ONE YEAR FROM THE <br />DATE OF OWNERS ACCEPTANCE. <br />ENGINEER IS NOT RESPONSIBLE FOR MATERIALS, METHODS, <br />INSTALLATION, AND CONSTRUCTION WHICH DEVIATE FROM <br />CONSTRUCTION DOCUMENTS AND SPECIFICATIONS. <br />ELECTRICAL SHEET INDEX <br />EO.1 - <br />ELECTRICAL GENERAL <br />EO.2 — <br />ELECTRICAL SPECIFICATIONS <br />E4.1 — <br />ELECTRICAL PROPOSED LIGHTING PLAN <br />E5.1 — <br />ELECTRICAL PROPOSED POWER PLAN <br />E5.2 — <br />ELECTRICAL ROOF POWER PLAN <br />E7.1 — <br />ELECTRICAL SCHEDULES & RISER DIAGRAM <br />E8.1 - <br />NOT USED <br />EO.1 - <br />ELECTRICAL DETAILS <br />SWITCHES <br />0 <br />$M <br />0S <br />$a <br />REFER TO SHEET E9.1 FOR SWITCH DETAILS. <br />ELECTRICAL SYMBOL LEGEND <br />WIRING DEVICES <br />NOTE: THE FOLLOWING ABBREVIATIONS APPLY TO WIRING DEVICES WHERE INDICATED: <br />'WP' INDICATES WEATHERPROOF WHILE -IN -USE ENCLOSURE. ENCLOSURE SHALL HAVE <br />LOCKABLE COVER. DEVICES SHALL BE LISTED AS WEATHER RESISTANT. (WR) <br />'EWC' INDICATES DEVICE MOUNTED BEHIND ELECTRIC WATER COOLER ENCLOSURE. <br />COORDINATE DEVICE LOCATION WITH PLUMBING CONTRACTOR AND APPROVED <br />"2P" INDICATES A 2-POLE SWITCH <br />SHOP DRAWINGS PRIOR TO ROUGH -IN. CIRCUIT BREAKER SHALL BE GFCI TYPE. <br />'H' <br />INDICATES HORIZONTALLY MOUNTED WIRING DEVICE. <br />"3" INDICATES THREE-WAY SWITCH <br />'R' <br />INDICATES DEVICE SHALL BE A RED COLOR. DEVICE IS CONNECTED TO A CIRCUIT <br />FED FROM THE GENERATOR (IF APPLICABLE). <br />"4" INDICATES FOUR-WAY SWITCH <br />'FD' <br />INDICATES RECEPTACLE MOUNTED IN FLOOR DUCT. INSTALL ACCESSORIES FOR <br />MOUNTING OF RECEPTACLE IN FLOOR DUCT SYSTEM. <br />"30A" INDICATES THE AMPERAGE OF THE SWITCH FOR NON-STANDARD <br />'IG' <br />ISOLATED GROUND <br />SWITCHES <br />'USB' <br />INDICATES RECEPTACLE WITH USB OUTLETS. <br />(I) <br />20 AMP SIMPLEX RECEPTACLE, RECESS MOUNT 18" AFF TO CENTER OF BACKBOX OR <br />REFER TO SHEET E9.1 FOR SWITCH DETAILS. <br />'I' <br />AT HEIGHT INDICATED. <br />"K" INDICATES KEY SWITCH. PROVIDE OWNER WITH (2) KEYS PER SWITCH. <br />20 AMP DUPLEX RECEPTACLE, RECESS MOUNT 18" AFF TO CENTER OF BACKBOX. <br />MATCH ANY EXISTING KEYED SWITCHES IF RENOVATION. VERIFY KEY TYPE <br />20 AMP DUPLEX RECEPTACLE, RECESS MOUNT AT HEIGHT INDICATED OR ABOVE <br />(MANUFACTURER) WITH OWNER <br />COUNTER, CASEWORK, ETC. COORDINATE MOUNTING HEIGHT WITH ARCHITECTURAL <br />"M" INDICATES THE SWITCH SHALL BE MOTOR DUTY RATED <br />ELEVATIONS AND EXISTING CONDITIONS PRIOR TO ROUGH -IN. <br />AFCI <br />20 AMP DUPLEX RECEPTACLE WITH ARC FAULT CIRCUIT INTERRUPTER (AFCI) <br />"OS" INDICATES OCCUPANCY SENSOR SWITCH (SENSOR SWITCH WSX PDT) <br />If <br />PROTECTION, RECESS MOUNT AT HEIGHT INDICATED OR ABOVE COUNTER, <br />CASEWORK, ETC. COORDINATE MOUNTING HEIGHT WITH ARCHITECTURAL <br />"TS" INDICATES INTERVAL TIMER SWITCH PROGRAMMED FOR 30 MINUTES <br />ELEVATIONS AND EXISTING CONDITIONS PRIOR TO ROUGH -IN. <br />MAXIMUM ALLOWED TIME (SENSOR SWITCH PTS60) <br />AFCI <br />20 AMP DUPLEX RECEPTACLE WITH ARC FAULT CIRCUIT INTERRUPTER (AFCI) <br />"P" INDICATES SWITCH WITH PILOT LIGHT. <br />(ttj <br />PROTECTION, RECESS MOUNT 18" AFF TO CENTER OF BACKBOX. 1 OF 2 <br />RECEPTACLES IS SWITCHED, REMOVE JUMPER BETWEEN OUTLETS. <br />"R" INDICATES DEVICE SHALL BE A RED COLOR. DEVICE IS CONNECTED TO A <br />AFCI <br />1p <br />20 AMP DUPLEX RECEPTACLE WITH ARC FAULT CIRCUIT INTERRUPTER (AFCI) <br />CIRCUIT FED FROM A GENERATOR (IF APPLICABLE). <br />PROTECTION, RECESS MOUNT 18" AFF TO CENTER OF BACKBOX. <br />LOWER CASE LETTER (i.e. "a") INDICATES THE FIXTURE(S) CONTROLLED BY <br />!1fh: <br />20 AMP DOUBLE DUPLEX (QUAD) RECEPTACLE WITH COMMON COVER PLATE, RECESS <br />THE SWITCH. <br />MOUNT 18" AFF TO CENTER OF BACKBOX. <br />20 AMP DOUBLE DUPLEX (QUAD) RECEPTACLE WITH COMMON COVER PLATE, RECESS <br />MOUNT ABOVE COUNTER, CASEWORK, ETC OR AT HEIGHT INDICATED. COORDINATE <br />LIGHTING FIXTURES (REFER TO THE "LIGHTING FIXTURE SCHEDULE") <br />MOUNTING HEIGHT WITH ARCHITECTURAL ELEVATIONS AND CONDITIONS PRIOR TO <br />ROUGH -IN. <br />2' x 4' FLUORESCENT LIGHT FIXTURE (SEE LIGHT FIXTURE SCHEDULE) <br />b <br />NOTE: THE FOLLOWING ABBREVIATIONS APPLY TO LIGHTING FIXTURES WHERE <br />20 AMP DUPLEX RECEPTACLE, RECESS MOUNT 18" AFF TO CENTER OF BACKBOX. 1 OF <br />INDICATED: <br />2 RECEPTACLES IS SWITCHED, REMOVE JUMPER BETWEEN OUTLETS. <br />i 'A2' INDICATES FIXTURE TYPE <br />UPPER CASE LETTER/NUMBER .e. I IC I <br />( ) <br />F <br />® <br />ERE E FLUSH WITH FLOOR IN SINGLE GANG FLOOR <br />20 AMP DUPLEX RECEPTACLE. RECESS <br />LOWER CASE LETTER (i.e. 'U) INDICATES CONNECTION TO INDICATED SWITCH. <br />BOX. COVER SHALL BE BRASS WITH HINGED LID FOR EACH OUTLET OF RECEPTACLE. <br />NOTE: THE FOLLOWING ABBREVIATIONS APPLY TO LIGHTING FIXTURES WHERE <br />F(E) <br />20 AMP DOUBLE DUPLEX (QUAD) RECEPTACLE. RECESS FLUSH WITH FLOOR IN <br />EM <br />INDICATED: <br />DOUBLE GANG FLOOR BOX. COVER SHALL BE BRASS WITH HINGED LID FOR EACH <br />"EM" INDICATES LIGHT FIXTURE WITH EMERGENCY BATTERY PACK. <br />OUTLET OF RECEPTACLES. <br />0 <br />FLUORESCENT LIGHT FIXTURE (SEE LIGHT FIXTURE SCHEDULE) <br />GFI <br />20A SIMPLEX RECEPTACLE WITH GFCI PROTECTION MOUNTED AT HEIGHT OR AS <br />O <br />DOWNLIGHT <br />`P <br />INDICATED. VERIFY RATING AND NEMA CONFIGURATION FOR EQUIPMENT TO BE <br />CONNECTED. <br />WALL SCONCE <br />GFI <br />20 AMP DUPLEX RECEPTACLE WITH GFCI PROTECTION, RECESS MOUNT 18" AFF TO <br />PENDANT <br />[P <br />CENTER OF BACKBOX. <br />EXIT SIGN WITH BATTERY PACK, MOUNTED WITHIN 6'-8" OF TOP OF <br />OPENING PER NFPA 101:7.10.1.9. FACES AND ARROWS SHALL BE AS <br />GFI <br />20 AMP DUPLEX RECEPTACLE WITH GFCI PROTECTION, RECESS MOUNT ABOVE SINK, <br />COUNTER, CASEWORK, ETC. OR AT HEIGHT INDICATED. COORDINATE MOUNTING <br />[P <br />IITT <br />INDICATED ON PLANS. CONNECT FIXTURE TO LIGHTING CIRCUIT SERVING <br />HEIGHT WITH ARCHITECTURAL ELEVATIONS AND CONDITIONS PRIOR TO ROUGH -IN. <br />THE AREA, AHEAD OF ANY SWITCHING OR CONTROLS. <br />GFI <br />20 AMP DOUBLE DUPLEX (QUAD) RECEPTACLE WITH GFCI PROTECTION AND COMMON <br />A f <br />EMERGENCY EGRESS LIGHTING UNIT WITH BATTERY PACK MOUNTED <br />COVER PLATE, RECESS MOUNT 18" AFF TO CENTER OF BACKBOX. <br />T-6" AFF OR AS INDICATED. CONNECT FIXTURE TO LIGHTING CIRCUIT <br />SERVING THE AREA, AHEAD OF ANY SWITCHING OR CONTROLS. <br />® <br />MULTI -POLE RECEPTACLE FOR APPLIANCE MOUNTED AS INDICATE. COORDINATE <br />EXIT SIGN AND EMERGENCY EGRESS LIGHTING COMBO UNIT WITH <br />ID <br />AMPERAGE RATING, POLES, NEMA CONFIGURATION, ETC. WITH EQUIPMENT TO BE <br />A& <br />BATTERY PACK MOUNTED T-6" AFF. CONNECT FIXTURE TO LIGHTING <br />CONNECTED. <br />CIRCUIT SERVING THE AREA, AHEAD OF ANY SWITCHING OR <br />20 AMP DUPLEX RECEPTACLE, RECESS MOUNT HORIZONTALLY AT HEIGHT INDICATED. <br />CONTROLS. <br />PASSIVE INFRARED (PIR) OCCUPANCY SENSOR. 360°. 450 SQ. FT. <br />20 AMP DUPLEX RECEPTACLE MOUNTED 18" AFF, ABOVE COUNTER, OR AT HEIGHT <br />INDICATED RECEPTACLE COORDINATED WITH DATA OUTLET FOR <br />COVERAGE. SENSOR SWITCH CM 10. CONNECT TO LOCAL POWER PACK. <br />(INDICATES <br />COMPUTER USE). <br />MULTI-TECHNLOGY (PIR & ULTRASONIC) OCCUPANCY SENSOR. 360°. 1000 <br />SQ. FT. COVERAGE. SENSOR SWITCH CM-PDT-10. CONNECT TO LOCAL <br />20 AMP DOUBLE DUPLEX (QUAD) RECEPTACLE MOUNTED 18" AFF, ABOVE COUNTER, <br />POWER PACK. <br />OR AT HEIGHT INDICATED (INDICATES RECEPTACLE COORDINATED WITH DATA <br />EXT. <br />EXTERIOR PASSIVE INFRARED (PIR) OCCUPANCY SENSOR SBO-10-OEX. <br />OUTLET FOR COMPUTER USE). <br />CONNECT TO LOCAL POWER PACK. PROVIDE BOX FOR CEILING MOUNTING. <br />0 <br />POWER POLE. 2-SECTION (POWER AND COMMUNICATIONS), 2" SQUARE METALLIC, <br />PP <br />OCCUPANCY SENSOR POWER PACK. 20A @120/277VAC. PROVIDE <br />BRUSHED ALUMINUM FINISH. DEVICES MOUNTED AT POLE AS SHOWN. POLE SHALL <br />QUANTITY AS NEEDED. SENSOR SWITCH PP-20-2P. CONNECT TO LOCAL <br />EXTEND FROM FLOOR TO CEILING, SECURE TO CEILING. <br />Ps <br />OCCUPANCY SENSORS. <br />20 AMP DUPLEX RECEPTACLE, FLUSH MOUNT AT CEILING. SUPPORT BACKBOX FROM <br />LED POWER SUPPLY (TECLED MODEL: VBS-12060DO24) <br />® <br />STRUCTURE, NOT GRID. <br />COMMUNICATIONS <br />F <br />2-SECTION FLOOR BOX WITH DUPLEX RECEPTACLE AND DATA SECTION. FLOOR BOX <br />1-GANG DEEP BOX FOR TELEPHONE OUTLET, RECESS MOUNT 18" TO CENTER <br />SHALL BE FLUSH WITH FLOOR WITH CARPET/TILE PLATE AND TRAP DOOR FOR WIRING <br />OF BACKBOX AFF, ABOVE COUNTER OR AS NOTED. INSTALL 3/4" CONDUIT <br />OUT OF BOX. <br />WITH BUSHINGS AND PULL STRING STUBBED INTO ACCESSIBLE CEILING <br />0 <br />JUNCTION BOX. FAN RATED IN DWELLING UNITS. <br />SPACE ABOVE BACKBOX. INSTALL BLANK COVERPLATE. NUMBER OF PHONE <br />JACKS AS INDICATED OR INSTALL BLANK COVERPLATE. 'W INDICATES PHONE <br />DC <br />DROP CORD. RECEPTACLE AND BOX SUSPENDED FROM JUNCTION BOX AT CEILING <br />WILL BE WALL MOUNTED, MOUNT AT 48" AFF TO CENTER OF BACKBOX AND <br />° <br />WITH S/O CORD. PROVIDE STRAIN RELIEF AT EACH END OF CORD. RECEPTACLE <br />INSTALL WALL PHONE PLATE. <br />SHALL BE TYPE OF DEVICE SHOWN. <br />® <br />(2) GANG DEEP BOX FOR DECORA STYLE DUPLEX RECEPTACLE AND <br />PLUGMOLD WITH RECEPTACLES 12" ON -CENTER. PLUGMOLD SHALL BE <br />TELEVISION OUTLET. COORDINATE MOUNTING HEIGHT AND LOCATION. <br />cmwmw*a <br />NON-METALLIC, 2-PIECE. MOUNT AS INDICATED. VERIFY COLOR OF FINISH, <br />INSTALL 3/4" CONDUIT FOR LOW VOLTAGE WIRING WITH BUSHINGS AND PULL <br />STRING STUBBED INTO ACCESSIBLE CEILING SPACE ABOVE BACKBOX. <br />POWER DISTRIBUTION (REFER TO THE "ELECTRICAL RISER DIAGRAM") <br />INSTALL DECORA COVERPLATE. <br />v 1-GANG DEEP BOX FOR TELEPHONE / DATA OUTLET, RECESS MOUNT 18" TO <br />CENTER OF BACKBOX AFF, ABOVE COUNTER OR AS NOTED. INSTALL 3/4" <br />CONDUIT WITH BUSHINGS AND PULL STRING STUBBED INTO ACCESSIBLE <br />CEILING SPACE ABOVE BACKBOX. INSTALL BLANK COVERPLATE. <br />CABINET. SEE PLANS AND SPECIFICATIONS FOR USAGE AND <br />REQUIREMENTS. <br />MISCELLANEOUS <br />O KEYED NOTE INDICATOR. REFER TO THE "KEYED NOTES" WHERE <br />INDICATED. <br />Q®Q EXHAUST FAN. <br />'R' SYMBOL INDICATES TO PROVIDE AND INSTALL 10 MINUTE TIME DELAY OFF <br />RELAY. EXHAUST FAN SHALL OPERATE FOR 10 MINUTES AFTER <br />LIGHTING SWITCH IS TURNED OFF. CONNECT HOT LEAD FROM <br />AHEAD OF SWITCH TO RELAY FOR DELAYED OPERATION AND <br />SWITCH LEG TO RELAY FOR NORMAL OPERATION. <br />'T' SYMBOL INDICATES TO PROVIDE AND INSTALL 277V-120V <br />TRANSFORMER. WATTAGE OF TRANSFORMER VA SHALL BE A <br />MINIMUM 20% GREATER THAN EXHAUST FAN POWER <br />REQUIREMENTS, COORDINATE WITH MECHANICAL CONTRACTOR. <br />r7I MOTORIZED DAMPER. PROVIDE POWER AND MAKE CONNECTIONS AS <br />INDICATED. COORDINATE WITH MECHANICAL CONTRACTOR. <br />sP CEILING MOUNTED SPEAKER LOCATIONS ON A/V SYSTEM <br />ABBREVIATIONS <br />AFF <br />HEIGHT ABOVE FINISHED FLOOR <br />AFG <br />HEIGHT ABOVE FINISHED GRADE <br />ETR <br />EXISTING TO REMAIN <br />EXT <br />EXTERIOR <br />TYPE WIRING DEVICE OR CIRCUIT <br />BREAKER <br />LTG <br />LIGHTING <br />MTR <br />MOTOR <br />N.I.C. <br />NOT IN CONTRACT <br />NF <br />NON -FUSED <br />PH <br />PHASE <br />REL <br />RELOCATED <br />REM <br />TO BE REMOVED <br />REP <br />REPLACE WITH NEW <br />TBR <br />TO BE RELOCATED <br />U.N.O. <br />UNLESS NOTED OTHERWISE <br />VA <br />VOLT AMPERE (POWER) <br />WP <br />WEATHERPROOF ENCLOSURE <br />XFMR <br />TRANSFORMER <br />+48" <br />DEVICE MOUNTED AT HEIGHT <br />INDICATED <br />. . r-/ANCLDU1-%r, J, r[C1,C00 IVIVL/IV 1 Iry FIIVIJ"L_L1 JrnV CO, 3urxFnVC IVIV VIv 1 11V Un�.r\ V1 <br />HOUSE. REFER TO THE "PANELBOARD SCHEDULE". <br />FEEDER OR BRANCH CIRCUIT RACEWAY CONCEALED IN WALL, CEILING. <br />"— FEEDER OR BRANCH CIRCUIT RACEWAY CONCEALED UNDER FLOOR, IN SLAB OR <br />BELOW GRADE. <br />C=l' DISCONNECT SWITCH. PROVIDE DISCONNECT SWITCH AS INDICATED ON THE <br />SCHEDULES. REFER TO PLANS AND SCHEDULES FOR ADDITIONAL REQUIREMENTS. <br />FUSES SHALL BE DUAL ELEMENT TIME DELAY. VERIFY NAMEPLATE RATINGS OF <br />FRAME SIZE AND FUSING OF THE ACTUAL EQUIPMENT TO BE INSTALLED. <br />DRY -TYPE VENTILATED TRANSFORMER. SEE SPECIFICATIONS, PLANS AND RISER <br />FOR REQUIREMENTS. TRANSFORMERS SHALL BE NEMA 1 UNLESS AT THE EXTERIOR <br />OR IN AREAS WHERE WATER MAY BE PRESENT. MOUNT ON 4" HOUSE KEEPING PAD <br />BOLTED TO PAD. MAINTAIN REQUIRED CLEARANCE FROM WALLS OR <br />OBSTRUCTIONS FOR VENTILATION. <br />�f— GROUND TO METAL FRAME OF BUILDING, SLAB STEEL, OTHER MADE ELECTRODES, <br />AND METAL UNDERGROUND WATER PIPE. PROVIDE A MINIMUM OF (3) 3/4" DIA, 10 <br />FOOT LONG COPPER CLAD GROUND RODS LOCATED AT LEAST 6 FEET APART. ALL <br />CONCEALED CONNECTIONS SHALL BE EXOTHERMICALLY WELDED. INTERIOR <br />GROUND RODS SHALL STUB ABOVE FLOOR AT LOCATIONS NOT INTERFERING WITH <br />FOOT TRAFFIC. LOCATE EXTERIOR GROUND ROD ASSEMBLY IN LANDSCAPE AREA <br />OR PROVIDE WELL FOR ACCESS TO EACH GROUND ROD IF ASSEMBLY IS LOCATED <br />IN HARD SURFACE AREAS, SUCH AS CONCRETE, ASPHALT, ETC. PROVIDE BOLTED <br />PRESSURE CLAMP WITH AT LEAST TWO BOLTS ON RODS IN TEST WELLS. ALL <br />GROUND ROD LOCATIONS SHALL BE ACCESSIBLE. <br />VARIABLE FREQUENCY DRIVE. REFER TO SPECIFICATIONS, AND FLOOR PLANS FOR <br />ADDITIONAL ELECTRICAL REQUIREMENTS. VFD SUPPLIED BY MECHANICAL <br />CONTRACTOR (U.N.O.) AND INSTALLED BY ELECTRICAL CONTRACTOR. ALL <br />CONNECTIONS TO VFD, DISCONNECT AND EQUIPMENT SERVED SHALL BE BY THE <br />ELECTRICAL CONTRACTOR. CIRCUIT SHALL UTILIZE METAL CONDUIT TO MINIMIZE <br />RFI NOISE. <br />COMBINATION MOTOR STARTER WITH FUSED DISCONNECT OR CIRCUIT BREAKER <br />DISCONNECT. REFER TO PLANS AND SCHEDULES FOR ADDITIONAL REQUIREMENTS. <br />FUSES SHALL BE DUAL ELEMENT TIME DELAY. VERIFY NAMEPLATE RATINGS OF <br />FRAME SIZE AND FUSING OF THE ACTUAL EQUIPMENT TO BE INSTALLED. <br />LP-1 PANEL HOMERUN/CIRCUIT <br />PANEL DESIGNATION/CIRCUIT NUMBER <br />NOTE: NOT ALL SYMBOLS SHOWN ON LEGEND ARE USED ON FLOOR PLANS. <br />GENERAL NOTES <br />**GENERAL NOTES APPLY TO ALL ELECTRICAL SHEETS** <br />1. DO NOT SCALE FROM THESE DRAWINGS. <br />2. ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH THE 2017 EDITION OF <br />THE NATIONAL ELECTRICAL CODE (NEC) NFPA 70. <br />3. ELECTRICAL CONTRACTOR (E.C.) SHALL COORDINATE WORK WITH ALL OTHER TRADES <br />TO ASSURE PROPER CLEARANCES FOR EQUIPMENT AND TO KEEP THE JOB <br />PROGRESSING. <br />4. DRAWINGS ARE BASED ON FIELD OBSERVATION AND EXISTING DOCUMENTS. REPORT <br />ANY DISCREPANCIES TO THE ENGINEER BEFORE DISTURBING EXISTING INSTALLATION. <br />5. EXISTING TO REMAIN ELECTRICAL CIRCUITRY DOWNSTREAM AND UPSTREAM OF <br />DEMOLISHED DEVICES SHALL BE MAINTAINED, E.C. SHALL PROVIDE ALL ELECTRICAL <br />COMPONENTS (BOXES, CONDUIT, WIRING, ETC.) AS REQUIRED. <br />6. ELECTRICAL CONTRACTOR SHALL BE REQUIRED TO CUT, CAPTURE AND EXTEND OR <br />RE-ROUTE EXISTING CONDUITS AND CONDUCTORS AS REQUIRED TO ACCOMMODATE <br />NEW DUCTWORK. COORDINATE WITH MECHANICAL CONTRACTOR AS REQUIRED. <br />7. REFER TO MECHANICAL DRAWINGS FOR EQUIPMENT NEEDING ELECTRICAL <br />CONNECTIONS (MOTORS, FANS, PUMPS, ETC.). MAKE ALL CONNECTIONS AND PROVIDE <br />APPROPRIATE WIRE, CONDUIT, AND OVERCURRENT PROTECTION FOR ALL EQUIPMENT. <br />INSTALL ANY ELECTRICAL EQUIPMENT (STARTERS, RELAYS, VFD'S, ETC.) FURNISHED <br />BY MECHANICAL CONTRACTOR (DIV 15). COORDINATE EXACT REQUIREMENTS WITH <br />MECHANICAL CONTRACTOR. <br />8. VOLTAGE DROP: THE CONDUCTORS FOR FEEDERS AND BRANCH CIRCUITS COMBINED <br />SHALL BE SIZED FOR A MAXIMUM OF 5% VOLTAGE DROP TOTAL PER FBC-ENERGY <br />C405.6.3. USE 10 AWG CU. CONDUCTORS FOR 20 AMPERE, 120 VOLT BRANCH CIRCUITS <br />LONGER THAN 75 FEET. USE 10 AWG CU. WHERE WIRE SIZE IS INCREASED IN SIZE FOR <br />VOLTAGE DROP, E.G SHALL BE INCREASED PROPORTIONATELY. PER NEC 250.122 (B). <br />9. ALL CEILING MOUNTED ITEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE <br />ARCHITECTURAL REFLECTED CEILING PLANS. IF LOCATION FOR AN ITEM IS NOT SHOWN <br />ON THE ARCHITECTURAL REFLECTED CEILING PLANS, VERIFY THE EXACT LOCATION OF <br />THE ITEM WITH THE ARCHITECT PRIOR TO INSTALLATION. <br />10. WHERE DISCONNECTING MEANS IS NOT PROVIDED "WITHIN SIGHT" FROM EQUIPMENT <br />SERVED, THE OVERCURRENT DEVICE SERVING SUCH EQUIPMENT SHALL HAVE <br />PERMANENT PROVISION TO LOCK IN THE OPEN POSITION PER NEC 422.31 AND 110.25. <br />11. CONDUIT RUNS SHOWN ARE DIAGRAMMATIC IN NATURE. ELECTRICAL CONTRACTOR <br />SHALL BE RESPONSIBLE FOR SIZING AND LOCATING PULL BOXES PER NEC. <br />12. PROVIDE ALL H.I.D. AND FLUORESCENT LIGHT FIXTURES WITH INTEGRAL FUSING. <br />13. CONNECT EXIT SIGNS AND EGRESS LIGHTS TO LOCAL LIGHTING CIRCUIT AHEAD OF <br />ANY SWITCHING PER NEC 700.12(F). <br />14. RECEPTACLES IN MECHANICAL ROOMS, ELECTRICAL ROOMS, STORAGE ROOMS, AND <br />JANITOR CLOSETS SHALL BE G.F.C.I. TYPE MOUNTED AT 48" A.F.F. <br />15, PROVIDE REVISED PHOTOMETRICS FOR ANY SUBSTITUTE FIXTURES. <br />CONDUIT AND CONDUCTOR SCHEDULE <br />C.B. <br />POLES <br />WIRE SIZE P THW) <br />CONDUIT <br />PHASE <br />20A <br />1 <br />2412, 1412 E.G. <br />3/4 <br />10 2W <br />2 <br />2-#12, 1-#12 E.G. <br />10 2W <br />3 <br />3-#12, 1-#12 E.G. <br />30 3W <br />3 <br />3412, 1412 N., 1412 E.G. <br />30 4W <br />25A <br />1 <br />2410, 1410 E.G. <br />3/4 <br />10 2W <br />2 <br />2-#10, 1-#10 E.G. <br />10 2W <br />3 <br />3-#10, 1-#10 E.G. <br />30 3W <br />3 <br />3410, 1-#10 N., 1410 E.G. <br />30 4W <br />30A <br />1 <br />2410, 1410 E.G. <br />3/4 <br />10 2W <br />2 <br />2-#10, 1-#10 E.G. <br />10 2W <br />3 <br />3-#10, 1-#10 E.G. <br />30 3W <br />3 <br />3410, 1410 N., 1410 E.G. <br />30 4W <br />35A <br />3 <br />3-#8, 1-#10 E.G. <br />1 <br />30 3W <br />3 <br />3-#8, 148 N., 1-#10 E.G. <br />30 4W <br />40A <br />2 <br />248, 1-#10 E.G. <br />1" <br />10 2W <br />3 <br />348, 1410 E.G. <br />30 3W <br />3 <br />348, 148 N., 1410 E.G. <br />30 4W <br />45A <br />2 <br />248, 1410 E.G. <br />1" <br />10 2W <br />3 <br />348, 1410 E.G. <br />30 3W <br />3 <br />348, 148 N., 1410 E.G. <br />30 4W <br />50A <br />2 <br />248, 1410 E.G. <br />1" <br />10 2W <br />3 <br />348, 1410 E.G. <br />30 3W <br />3 <br />348, 148 N., 1410 E.G. <br />30 4W <br />60A <br />2 <br />246, 1410 E.G. <br />1 <br />10 2W <br />3 <br />346, 1410 E.G. <br />30 3W <br />3 <br />346, 146 N., 1410 E.G. <br />1 1/4" <br />30 4W <br />2 <br />244, 148 E.G. <br />1" <br />10 2W <br />70A <br />3 <br />344, 148 E.G. <br />1 1/4" <br />30 3W <br />3 <br />3-#4, 1-#4 N., 148 E.G. <br />30 4W <br />2 <br />244, 148 E.G. <br />1" <br />10 2W <br />80A <br />3 <br />344, 148 E.G. <br />1 1/4" <br />30 3W <br />3 <br />344, 144 N., 148 E.G. <br />30 4W <br />90A <br />2 <br />243, 148 E.G. <br />1 1/4" <br />10 2W <br />3 <br />343, 148 E.G. <br />30 3W <br />3 <br />343, 143 N., 148 E.G. <br />30 4W <br />100A <br />2 <br />243, 148 E.G. <br />1 1/4" <br />10 2W <br />3 <br />343, 148 E.G. <br />30 3W <br />3 <br />343, 143 N., 148 E.G. <br />30 4W <br />NOTES: <br />1. ALL CONDUCTORS SHALL BE COPPER <br />2. ALL CONDUIT SHALL HAVE EQUIPMENT GROUNDING CONDUCTOR INSTALLED. <br />3. CONDUIT BELOW GRADE OUTSIDE OF BUILDING SHALL BE 1" MINIMUM. <br />4. SIZING OF CONDUCTORS SHALL BE ALTERED FOR DERATING PER N.E.C. OR VOLTAGE <br />DROP CONSIDERATIONS. <br />5. SEE RISER DIAGRAM FOR SIZING OF CIRCUITS GREATER THAN 100A. <br />6. USE #10 AWG, COPPER CONDUCTORS FOR 20 AMPERE, 120 VOLT BRANCH CIRCUITS <br />LONGER THAN 75 FEET. USE #10 AWG, COPPER CONDUCTORS FOR 20 AMPERE, 277 VOLT <br />BRANCH CIRCUITS LONGER THAN 200 FEET. WHERE WIRE SIZE IS INCREASED IN SIZE FOR <br />VOLTAGE DROP, EQUIPMENT GROUND SHALL BE INCREASED PROPORTIONATELY PER <br />NEC 250.122 (B). <br />7. WHERE MC CABLE IS ALLOWED BY THE AUTHORITY HAVING JURISDICTION, THE <br />CONDUCTORS FOR MC CABLE SHALL BE THHN. JACKET SHALL BE THE MANUFACTURER'S <br />STANDARD SIZE FOR CONDUCTORS UTILIZED. <br />GS JOB iP: SS31 .21 .00 <br />GLOBAL <br />34%NCrLjirC__Z1NC <br />MEPP ENGINEERING <br />INFO@GLOBAL-SANCHEZ. COM <br />CA#: 6237 <br />B 1 6 MANATEE AVE. E, SUITE 1 B <br />BRADENTON, FL 3420B <br />PHONE: 941-75B-2551 <br />3B25 HENDERSON BLVD., <br />SUITE 1 ❑3 <br />TAMPA, FL 33629 <br />PHONE: 81 3-2B 1 -❑❑❑ 1 <br />C&K ARCHITECTS I INTERIORS <br />architecture. interior design• client services <br />AAC001629 <br />4221 WEST BOY SCOUT BLVD., SUITE 150 <br />TAMPA, FL 33607-5743 <br />813.884.2000 <br />280 WEST CENTRAL AVE. <br />WINTER HAVEN, FL 33880-2957 <br />863.577.2054 <br />�P 3. FE/ <br />•°ENS°'•!rF <br />Q 5083 °• <br />5 /2021;` W <br />O STATE OF <v <br />� ••'' :r�•OR10P•° Gam? <br />° <br />sS/ <br />�\41 <br />0 N A L <br />0 <br />0 <br />s <br />ma <br />0 <br />0 <br />Z <br />J <br />LL <br />J <br />x <br />a <br />1,, <br />N <br />J U) <br />q 0 <br />LZ H <br />�.�..� Q/ <br />Z <br />Lu <br />to <br />Q =0 <br />w <br />V °' 0 <br />N <br />� <br />C <br />V m <br />W m <br />J <br />Lu m <br />0 <br />J <br />m <br />J <br />Q <br />C9 <br />M <br />L0 <br />0, <br />LO <br />ISSUED FOR: <br />PERMIT <br />PROJECT NUMBER <br />21020 <br />DATE <br />5.5.21 <br />DRAWING NUMBER <br />