Laserfiche WebLink
Cz <br />Em <br />cz <br />62 <br />N S, <br />if <br />a <br />m <br />0 <br />O <br />N <br />V <br />W <br />H <br />Q <br />ELECTRICAL <br />PART 1 -GENERAL <br />0.01 GENERAL SCOPE <br />A. THIS PROJECT WILL REQUIRE POWER DISTRIBUTION, LIGHTING, AND <br />LIGHTING CONTROLS SYSTEMS AS SHOWN ON THE PLANS AND INCLUDED IN <br />THE SPECIFICATIONS. <br />B. THE SCOPE OF WORK SPECIFIED HEREIN CONSISTS OF PROVIDING <br />(DEFINED AS FURNISH AND INSTALL) ALL LABOR, MATERIALS, EQUIPMENT <br />AND SERVICES REQUIRED TO COMPLETE THE ELECTRICAL AND RELATED <br />WORK INDICATED ON THE DRAWINGS, AS SPECIFIED HEREIN AND SUBJECT <br />TO THE TERMS AND CONDITIONS OF THE CONTRACT. ELECTRICAL WORK <br />INCLUDES, BUT IS NOT LIMITED TO, THE FOLLOWING: <br />• PANELBOARDS <br />• CIRCUIT BREAKERS <br />• DISCONNECT SWITCHES <br />• GROUNDING <br />• RACEWAY FOR POWER DISTRIBUTION <br />• CONDUCTORS FOR POWER DISTRIBUTION <br />• WIRING DEVICES <br />• LIGHTING FIXTURES <br />• RACEWAY FOR COMMUNICATIONS WIRING (VOICE, DATA, <br />CABLE TELEVISION) <br />• CONNECTION OF MOTORS, CONTROL DEVICES AND <br />ELECTRICAL EQUIPMENT FURNISHED BY OTHERS <br />• TESTING <br />• FINAL ACCEPTANCE/WARRANTY <br />• RECORD DRAWINGS <br />C. ITEMS SPECIFIED HEREIN, SHOWN ON THE DRAWINGS, AND/OR <br />REASONABLY INTERPRETED FROM THE DRAWINGS THAT ARE NECESSARY <br />TO COMPLETE THE ELECTRICAL WORK SHALL BE PROVIDED BY THIS <br />DIVISION, WHETHER ITEM IS SPECIFICALLY SHOWN OR NOT. <br />1.01 GENERAL DOCUMENTS <br />A. ELECTRICAL CONTRACTOR SHALL BECOME THOROUGHLY ACQUAINTED <br />WITH THE PROJECT SITE (e.g. EXISTING CONDITIONS) AND THE ENTIRE <br />CONSTRUCTION DOCUMENTS PACKAGE (e.g. ARCHITECTURAL, <br />STRUCTURAL, CIVIL, MECHANICAL, PLUMBING, FIRE PROTECTION, <br />ELECTRICAL DRAWINGS AND SPECIFICATIONS) BEFORE BID SUBMISSION. <br />WORK OF THE ELECTRICAL CONTRACTOR MUST BE COORDINATED WITH <br />THE WORK OF ALL TRADES. <br />B. THE INTENT OF THE DRAWINGS AND SPECIFICATIONS IS TO DESCRIBE THAT <br />COMPLETE ELECTRICAL AND SPECIAL SYSTEMS ARE REQUIRED. HOWEVER, <br />THE WORK SHALL BE COMPLETE <br />EVEN THOUGH ITEMS MAY NOT BE <br />SPECIFICALLY CALLED FOR OR SHOWN. INSTALLATIONS SHALL MEET ALL <br />GOVERNING CODES, SHALL BE SUBJECT TO THE APPROVAL OF THE <br />ARCHITECT/ENGINEER AND ALL AGENCIES HAVING JURISDICTION. <br />C. WORK NOT COVERED IN THIS SECTION. RECESSES, CHASES, AND OTHER <br />PROVISIONS TO BE MADE IN THE STRUCTURE AS REQUIRED TO <br />ACCOMMODATE ELECTRICAL ITEMS, SUCH AS CONDUIT, PANELS, <br />SWITCHES, ETC, SHALL BE PROVIDED BY THE TRADES CONCERNED. THE <br />ELECTRICAL CONTRACTOR SHALL, HOWEVER, NOTIFY ALL SUCH TRADES <br />OF HIS EXACT REQUIREMENTS AHEAD OF TIME AND SHALL PAY THE COSTS <br />OF ANY CUTTING OR PATCHING CAUSED BY FAILURE TO DO SO. ALL SUCH <br />REMEDIAL WORK SHALL BE DONE ONLY BY MECHANICS OF THE TRADES <br />INVOLVED. <br />1.02 PERMITS, TAXES, FEES. <br />A. ELECTRICAL CONTRACTOR SHALL OBTAIN ALL GOVERNMENTAL PERMITS, <br />PAY ALL SALES TAXES AND OTHER ASSOCIATED FEES INCLUDING COSTS <br />FOR UTILITY CONNECTIONS, REQUIRED TO PERFORM THE INTENDED <br />ELECTRICAL WORK. ELECTRICAL CONTRACTOR SHALL FILE ALL <br />NECESSARY PLANS, PREPARE ALL DOCUMENTS AND OBTAIN ALL <br />NECESSARY APPROVALS OF ALL GOVERNMENTAL AGENCIES HAVING <br />JURISDICTION. ELECTRICAL CONTRACTOR SHALL OBTAIN ALL REQUIRED <br />CERTIFICATES OF INSPECTION FOR ELECTRICAL WORK AND DELIVER SAME <br />TO THE OWNER AND ARCHITECT BEFORE REQUEST FOR ACCEPTANCE AND <br />FINAL PAYMENT FOR THE WORK. <br />B. ELECTRICAL CONTRACTOR SHALL INCLUDE IN THE WORK, WITHOUT EXTRA <br />COST TO THE OWNER, ALL LABOR, MATERIALS, SERVICES, APPARATUS, OR <br />DRAWINGS NECESSARY TO COMPLY WITH ALL APPLICABLE LAWS, <br />ORDINANCES, RULES AND REGULATIONS, WHETHER OR NOT SHOWN ON <br />DRAWINGS AND/OR SPECIFIED. <br />C. ALL MATERIALS FURNISHED AND ALL WORK INSTALLED SHALL COMPLY <br />WITH THE FOLLOWING: <br />• NATIONAL ELECTRIC CODE 2017 EDITION <br />• FLORIDA BUILDING CODE 7TH EDITION (EFF. 12/31/2020) <br />• APPLICABLE STATE AND LOCAL CODES <br />• NATIONAL BUREAU OF FIRE UNDERWRITERS <br />• REGULATIONS OF THE SERVING UTILITY COMPANIES <br />D. ALL MATERIAL AND EQUIPMENT PROVIDED FOR THE ELECTRICAL WORK <br />SHALL BEAR THE APPROVAL LABEL, OR SHALL BE LISTED, BY <br />UNDERWRITERS' LABORATORIES, INC. <br />1.03 MEASUREMENTS <br />A. SHOULD THE ELECTRICAL CONTRACTOR DISCOVER ANY DISCREPANCY <br />BETWEEN ACTUAL MEASUREMENTS AND THOSE INDICATED ON THE <br />DRAWINGS, WHICH PREVENTS FOLLOWING GOOD PRACTICE OR THE INTENT <br />OF THE DRAWINGS AND SPECIFICATIONS, HE SHALL NOTIFY THE <br />ARCHITECT/ELECTRICAL ENGINEER THROUGH THE GENERAL CONTRACTOR, <br />AND SHALL NOT PROCEED WITH HIS WORK UNTIL HE HAS RECEIVED <br />INSTRUCTIONS FROM THE ARCHITECT/ELECTRICAL ENGINEER. ALL <br />REQUESTS FOR INFORMATION (RFI) SHALL INCLUDE A PROPOSED <br />SOLUTION. <br />B. PRIOR TO ROUGH -IN OF EQUIPMENT THE GENERAL CONTRACTOR, <br />ARCHITECT AND ELECTRICAL ENGINEER RESERVE THE RIGHT TO <br />RELOCATE ANY PANELBOARD, DISCONNECT, STARTER, LIGHTING FIXTURE, <br />WIRING DEVICE, COMMUNICATIONS OUTLET, ETC THREE (3) FEET IN ANY <br />DIRECTION WITHOUT ANY ADDITIONAL CHARGE, FEE, OR CHANGE ORDER. <br />1.04 DRAWINGS <br />A. DRAWINGS ARE DIAGRAMMATIC <br />I IC AND INDICATE THE GENERAL LOCATION OF <br />THE ELECTRICAL AND SPECIAL SYSTEMS WORK INCLUDED IN THE <br />CONTRACT. THE ENTIRE CONSTRUCTION DOCUMENTS PACKAGE <br />(DRAWINGS AND SPECIFICATIONS) SHALL BE EXAMINED FOR EXACT <br />LOCATION OF FIXTURES, DEVICES <br />i S AND EQUIPMENT. WHERE ITEMS ARE NOT <br />LOCATED BY THE DRAWINGS OR SPECIFICATIONS OF OTHER CONSULTANTS <br />THEN THE ITEMS SHALL BE LOCATED PER THE ENGINEERING DRAWINGS, <br />HOWEVER, THE DRAWINGS ARE NOT TO BE SCALED. <br />B. ELECTRICAL CONTRACTOR SHALL FOLLOW THE ELECTRICAL DRAWINGS IN <br />LAYING OUT WORK AND SHALL COORDINATE WITH THE DRAWINGS OF <br />OTHER TRADES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED. <br />MAINTAIN MAXIMUM HEADROOM AND SPACE AT ALL LOCATIONS. WHERE <br />HEADROOM OR SPACE CONDITIONS APPEAR INADEQUATE, THE <br />ARCHITECT/ELECTRICAL ENGINEER SHALL BE NOTIFIED BEFORE <br />PROCEEDING WITH INSTALLATION. ALL REQUESTS FOR INFORMATION (RFI) <br />SHALL INCLUDE A PROPOSED SOLUTION. <br />C. IF DIRECTED BY THE ARCHITECT/ELECTRICAL ENGINEER, THE ELECTRICAL <br />CONTRACTOR SHALL, WITHOUT EXTRA CHARGE, MAKE REASONABLE <br />MODIFICATIONS IN THE LOCATIONS OF ELECTRICAL WORK AS NEEDED TO <br />PREVENT CONFLICTS WITH WORK OF OTHER TRADES AND FOR PROPER <br />INSTALLATION OF THE WORK. <br />1.05 SUBSTITUTION OF SPECIFIED EQUIPMENT <br />A. MATERIALS OR PRODUCTS SPECIFIED BY TRADE NAME, MANUFACTURER'S <br />NAME OR CATALOG NUMBER SHALL BE PROVIDED AS SPECIFIED. <br />B. SUBSTITUTIONS ARE NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM <br />THE ENGINEER VIA THE ARCHITECT TEN (10) WORKING DAYS PRIOR TO BID <br />DATE. APPROVALS OF "EQUIVALENT" MATERIALS OR PRODUCTS WILL BE <br />MADE AVAILABLE TO ALL KNOWN BIDDERS AND ISSUED AS AN ADDENDUM <br />(PRIOR TO BID) TO THE CONTRACT DOCUMENTS IF SUBSTITUTED <br />MATERIALS OR PRODUCTS ARE APPROVED BY ARCHITECT/ELECTRICAL <br />ENGINEER. <br />C. ANY CONTRACTOR PROPOSING AN 'EQUIVALENT' MATERIAL OR PRODUCT <br />MUST SUBMIT, WITH THE REQUEST, COMPLETE CATALOG INFORMATION TO <br />PERMIT EVALUATION OF THE PRODUCT. IN THE CASE OF LIGHTING <br />FIXTURES, AN INDEPENDENT TESTING LABORATORY TEST REPORT (NOT <br />THE MANUFACTURER'S) STATING FIXTURE EFFICIENCY AND PERFORMANCE, <br />SHALL ACCOMPANY THE REQUEST. <br />D. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE <br />CORRECTIONS TO ALL SITUATIONS CREATED BY THE SUBSTITUTION OF <br />MATERIALS OR PRODUCTS. THE ACCEPTANCE OF SUBSTITUTED MATERIALS <br />OR PRODUCTS, EITHER PRIOR TO BID OR THEREAFTER, DOES NOT RELIEVE <br />THE ELECTRICAL CONTRACTOR FROM THE RESPONSIBILITY TO PROVIDE <br />CORRECTIONS, AT THEIR EXPENSE, FOR ALL DISCREPANCIES AND <br />CONFLICTS CREATED BY THE SUBSTITUTION OF MATERIALS OR PRODUCTS. <br />1.06 SHOP DRAWINGS <br />A. ELECTRICAL CONTRACTOR SHALL SUBMIT FOR REVIEW AND APPROVAL <br />SHOP DRAWINGS OF ALL MATERIALS OR PRODUCTS REQUIRED TO <br />COMPLETE THE PROJECT AND NO MATERIALS OR PRODUCTS SHALL BE <br />DELIVERED TO THE JOB SITE OR INSTALLED UNTIL THE ELECTRICAL <br />CONTRACTOR HAS ELECTRICAL ENGINEER APPROVED SHOP DRAWINGS. <br />SHOP DRAWINGS FOR MATERIALS OR PRODUCTS SHALL BE SUBMITTED AS <br />ONE COMPLETE PACKAGE. ELECTRICAL CONTRACTOR SHALL FURNISH THE <br />NUMBER OF COPIES REQUIRED BY THE GENERAL AND SPECIAL CONDITIONS <br />OF THE CONTRACT, BUT IN NO CASE LESS THAN SIX (6) IDENTICAL COPIES. <br />SHOP DRAWINGS SHALL BE REVIEWED AND STAMPED BY THE ELECTRICAL <br />AND GENERAL CONTRACTORS FOR COMPLIANCE WITH THE SPECIFIED <br />MATERIALS AND PRODUCTS PRIOR TO SUBMISSION TO THE <br />ARCHITECT/ELECTRICAL ENGINEER. <br />B. SAMPLES, DRAWINGS, SPECIFICATIONS, CUT SHEETS, ETC SUBMITTED FOR <br />REVIEW SHALL BE PROPERLY LABELED AND SHALL INDICATE THE SPECIFIC <br />ITEM FOR WHICH THE ELECTRICAL CONTRACTOR IS PROPOSING TO <br />PROVIDE. <br />C. "NO EXCEPTION" RENDERED ON SHOP DRAWINGS SHALL NOT BE <br />CONSIDERED AS A GUARANTEE THAT THE MATERIAL OR PRODUCTS <br />COMPLY WITH THE BUILDING CONDITIONS OR MEASUREMENTS. WHERE <br />SHOP DRAWINGS ARE REVIEWED, SAID "NO EXCEPTION" DOES NOT IN ANY <br />WAY RELIEVE THE ELECTRICAL CONTRACTOR FROM THE RESPONSIBILITY <br />OF PROVIDING LABOR, MATERIAL OR PRODUCTS REQUIRED TO PERFORM <br />THE WORK AS REQUIRED BY THE DRAWINGS AND SPECIFICATIONS. <br />D. SHOP DRAWINGS SUBMITTALS ARE REQUIRED ON ELECTRICAL <br />DISTRIBUTION EQUIPMENT, PANELBOARDS, TRANSFORMERS, CONDUIT, <br />CONDUCTORS (WIRE), CIRCUIT BREAKERS, DISCONNECT SWITCHES, <br />WIRING DEVICES, FLOOR BOXES, LIGHT FIXTURES, TIMECLOCKS, <br />CONTACTORS AND SURGE PROTECTION DEVICES (SPD) <br />PART 2-PRODUCTS <br />2.01 SERVICE ENTRANCE <br />A. SERVICE ENTRANCE SHALL BE UNDERGROUND FROM THE POWER <br />COMPANY TRANSFORMER OR OTHER SERVICE POINT TO THE SERVICE <br />ENTRANCE METER/ EQUIPMENT SHOWN ON THE ELECTRICAL RISER <br />DIAGRAM AND/OR SITE PLAN. VOLTAGE/PHASE OF INCOMING POWER SHALL <br />BE AS INDICATED ON THE ELECTRICAL RISER DIAGRAM AND SHALL BE <br />VERIFIED WITH THE SERVING UTILITY COMPANY PRIOR TO BID. <br />2.02 PANELBOARDS <br />A. PROVIDE POWER DISTRIBUTION EQUIPMENT AS INDICATED ON THE <br />ELECTRICAL RISER DIAGRAM AND PANEL SCHEDULES. PANELBOARDS <br />SHALL BE OF DEAD FRONT CONSTRUCTION AND SHALL BE MANUFACTURED <br />BY SQUARE "D", GENERAL ELECTRIC, CUTLER -HAMMER OR SIEMENS. <br />B. PANELBOARDS SHALL NOT BE LESS THAN 20" WIDE AND SHALL BE <br />FABRICATED FROM CODE GAUGE STEEL WITH A POST FABRICATION <br />APPLIED GRAY ENAMEL FINISH. <br />C. PANELBOARD AND INTERNAL COMPONENTS SHALL BE CONSTRUCTED AND <br />U.L. LISTED TO WITHSTAND THE SYMMETRICAL SHORT CIRCUIT AMPERES <br />INDICATED ON THE ELECTRICAL RISER DIAGRAM OR PANEL SCHEDULES. <br />D. WIRE GUTTER SPACE SHALL COMPLY WITH U.L. AND NEC STANDARDS FOR <br />PANELBOARDS. <br />E. PANELBOARDS SHALL BE SURFACE OR FLUSH MOUNTED AS SHOWN ON <br />PANEL SCHEDULES AND/OR FLOOR PLANS. PANEL SHALL BE EQUIPPED <br />WITH RECESSED HINGES, FLUSH LOCK WITH CATCH AND SPRING LOADED <br />DOOR PULL. ALL LOCKS SHALL BE KEYED A LIKE. TURN OVER ALL KEYS TO <br />OWNER. <br />F. PROVIDE TYPED CIRCUIT IDENTIFICATION CARD INSIDE EACH PANEL, BASE <br />DESCRIPTION ON LOAD SERVED. <br />G. PROVIDE LAMINATED, ENGRAVED PLASTIC NAMEPLATE WITH WHITE <br />LETTERS STATING PANELBOARD NAME MOUNTED ON FRONT OF EACH <br />PANEL. MOUNT NAMEPLATE WITH METAL FASTNERS. MINIMUM NAMEPLATE <br />SIZE SHALL BE 3" WIDE BY 1-1/2" HIGH WITH 1/2" HIGH ENGRAVED LETTERS. <br />PROVIDE BLACK NAMEPLATE COLOR FOR NORMAL AND RED NAMEPLATE <br />COLOR FOR EMERGENCY PANELBOARDS OR COLOR AS REQUIRED TO MEET <br />OWNERS STANDARD NAMEPLATE COLORS. <br />2.03 CIRCUIT BREAKERS: <br />A. CIRCUIT BREAKERS SHALL BE QUICK -MAKE, QUICK -BREAK, THERMAL <br />MAGNETIC MOLDED CASE OF FRAME SIZE, NUMBER OF POLES AND TRIP <br />RATINGS AS SHOWN ON THE ELECTRICAL RISER DIAGRAM AND/OR PANEL <br />SCHEDULES. MULTI -POLE BREAKERS SHALL HAVE A SINGLE HANDLE TO <br />TRIP ALL POLES AT ONCE, CIRCUIT BREAKERS SHALL BE FROM THE SAME <br />MANUFACTURER AS THE POWER DISTRIBUTION EQUIPMENT. PROVIDE <br />CIRCUIT BREAKERS WITH GROUND FAULT AND ARC FAULT PROTECTION <br />WHERE REQUIRED. <br />2.04 DISCONNECT SWITCHES <br />A. DISCONNECT SWITCHES SHALL BE U.L. LISTED AND FROM SAME <br />MANUFACTURER AS POWER DISTRIBUTION EQUIPMENT. SWITCH BLADES <br />SHALL BE FULLY VISIBLE IN THE "OFF" POSITION WITH THE DOOR OPEN. ALL <br />CURRENT CARRYING PARTS SHALL BE PLATED T RESIST N I O SIS CORROSION. <br />B. SWITCHES SHALL BE QUICK -MAKE, QUICK -BREAK <br />Q 1 QUIC SUCH THAT DURING <br />NORMAL OPERATION, THE CONTACTS SHALL NOT BE CAPABLE OF BEING <br />RESTRAINED BY THE OPERATING HANDLE AFTER THE CLOSING OR <br />OPENING ACTION OF THE CONTACTS HAS STARTED. THE HANDLE AND <br />MECHANISM SHALL BE AN INTEGRAL PART OF THE BOX, NOT THE COVER, <br />WITH POSITIVE PADLOCKING PROVISIONS IN THE "OFF" POSITION. <br />C. PROVIDE HEAVY-DUTY, NEMA-1 ENCLOSURE UNLESS NEMA-3R (RAIN <br />PROOF) IS REQUIRED BY THE SWITCH LOCATION. ENCLOSURES SHALL BE <br />PROVIDED WITH A POST FABRICATION APPLIED GRAY ENAMEL FINISH. <br />D. FUSIBLE SWITCHES SHALL BE CAPABLE OF FIELD CONVERSION FROM <br />STANDARD CLASS-H FUSE SPACING TO CLASS-J FUSE SPACING WITHOUT <br />AFFECTING THE U.L. LISTING. THE SWITCH MUST ALSO ACCEPT CLASS-R <br />FUSES AND HAVE A FIELD INSTALLABLE U.L. LISTED REJECTION FEATURE <br />TO REJECT ALL FUSES EXCEPT CLASS-R. THE U.L. LISTED SHORT CIRCUIT <br />RATING, WHEN EQUIPPED WITH CLASS-J OR CLASS-R FUSES, SHALL BE <br />200,000AMPERES RMS SYMMETRICAL. <br />2.05 GROUNDING AND BONDING <br />A. PROVIDE A SINGLE, COMPLETE GROUNDING NETWORK FOR THE ENTIRE <br />ELECTRICAL AND SPECIAL SYSTEMS WHICH COMPLIES WITH NEC <br />REQUIREMENTS. <br />B. SERVICE NEUTRAL AND EQUIPMENT GROUND SHALL BE CONNECTED AT <br />ONE POINT INSIDE THE MAIN DISTRIBUTION PANEL WITH ONE CONTINUOUS <br />CONDUCTOR FROM THIS LOCATION TO THREE 10 FOOT LONG DRIVEN <br />GROUND RODS LOCATED IN A TRIANGULAR PATTERN, TO BUILDING STEEL <br />AND TO METAL WATER PIPE. <br />C. PROVIDE BONDING CONNECTION WITH GROUND BUSHING TO CONDUIT <br />FROM DISTRIBUTION PANEL TO THE BREAKERS AND PANELS SERVED. <br />D. CONNECTIONS TO GROUND RODS SHALL BE MADE WITH EXOTHERMIC <br />WELDS. PROVIDE TEST WELL OVER EACH GROUND ROD. <br />ELECTRICAL SPECIFICATIONS - DIVISION 16 <br />2.06 CONDUIT FOR POWER DISTRIBUTION WIRING <br />A. WIRING FOR POWER DISTRIBUTION SHALL BE INSTALLED IN RIGID METALLIC <br />(GALVANIZED STEEL) CONDUIT (RMC), INTERMEDIATE METAL CONDUIT (IMC), <br />ELECTRICAL METALLIC TUBING (EMT), FLEXIBLE METAL CONDUIT OR <br />SCHEDULE 40/80 PVC CONDUIT. PROVIDE THE CONDUIT TYPE INDICATED IN <br />THIS SPECIFICATION WHERE CONDUIT TYPE IS NOT NOTED ON THE <br />DRAWINGS. <br />B. RIGID GALVANIZED STEEL (RGS) CONDUIT WITH THREADED FITTINGS SHALL <br />BE PROVIDED ABOVE GROUND AT EXPOSED INTERIOR AND EXTERIOR <br />LOCATIONS WHERE CONDUIT MAY BE SUBJECTED TO PHYSICAL DAMAGE <br />FROM VEHICLES, MAINTENANCE EQUIPMENT, ETC. PROVIDE LARGE RADIUS <br />SWEEP ELBOWS FOR RGS CONDUIT. <br />C. IMC CONDUIT WITH THREADED FITTINGS SHALL BE PROVIDED IN ABOVE <br />GROUND, EXPOSED INTERIOR AND EXTERIOR LOCATIONS WHERE CONDUIT <br />WILL NOT BE SUBJECTED TO PHYSICAL DAMAGE, BUT WILL BE EXPOSED TO <br />RAIN WATER, HAZARDOUS CONDITIONS, ETC. THREADLESS FITTINGS FOR <br />IMC IS NOT ACCEPTABLE. <br />D. EMT CONDUIT WITH SET SCREW FITTINGS SHALL BE PROVIDED IN ABOVE <br />GROUND INTERIOR LOCATIONS WHERE CONDUIT WILL NOT BE SUBJECTED <br />TO PHYSICAL DAMAGE AND WILL REMAIN COMPLETELY DRY DURING ALL <br />WEATHER CONDITIONS. <br />E. EMT CONDUIT SHALL NOT BE USED IN LOCATIONS WHERE CONDUIT COULD <br />BE EXPOSED TO DIRECT/INDIRECT RAINWATER/LIQUIDS, WIND DRIVEN <br />RAIN, HOSE DOWN AREAS, OPEN AIR AREAS WITHOUT AIR CONDITIONING <br />(UNLESS CONDUIT WILL REMAIN COMPLETELY DRY DURING ALL WEATHER <br />CONDITIONS) AND AREAS WHERE RAINWATER/LIQUIDS MIGHT DRIP OR RUN <br />INTO CONDUIT, BACKBOXES OR DEVICES. <br />F. SCHEDULE 80 PVC CONDUIT SHALL BE USED FOR UNDERGROUND SERVICE <br />ENTRANCE FEEDERS AND ALL CONDUIT BELOW ROADWAYS U.N.O. ON THE <br />RISER DIAGRAMS AND/OR FLOOR PLANS. PROVIDE LARGE RADIUS RIGID <br />GALVANIZED STEEL ELBOWS FOR SCHEDULE 80 PVC CONDUIT. COAT RGS <br />ELBOWS WITH BLACK MASTIC. <br />G. SCHEDULE 40 PVC CONDUIT SHALL BE USED FOR ALL UNDERGROUND <br />FEEDERS AND WIRING EXCEPT FOR SERVICE ENTRANCE FEEDERS AND <br />UNDER ROADWAYS. PROVIDE LARGE RADIUS RIGID GALVANIZED STEEL <br />ELBOWS FOR SCHEDULE 40 PVC CONDUIT WHERE OVERALL CONDUIT RUN <br />IS GREATER THAN 100 FEET. COAT RGS ELBOWS WITH BLACK MASTIC. <br />H. PVC CONDUIT SHALL NOT BE USED MORE THAN SIX INCHES ABOVE <br />FINISHED GRADE IN EITHER INTERIOR OR EXTERIOR LOCATIONS. PVC <br />CONDUIT SHALL TRANSITION TO METAL CONDUIT NO MORE THAN SIX <br />INCHES ABOVE GRADE. <br />I. ALL PVC CONNECTIONS SHALL BE WATERTIGHT. <br />J. FLEXIBLE METAL CONDUIT SHALL BE USED TO CONNECT LIGHTING <br />FIXTURES AND EQUIPMENT SUBJECT TO VIBRATION, INCLUDING A/C <br />EQUIPMENT, MOTORS, TRANSFORMERS, ETC. PROVIDE LIQUID TIGHT <br />FLEXIBLE METAL CONDUIT AND FITTINGS FOR EXTERIOR APPLICATIONS. <br />K. CONCEAL ALL CONDUIT IN WALLS, PARTITIONS, OR CEILINGS IN FINISHED <br />AREAS. CONDUIT SHALL NOT BE EXPOSED IN FINISHED AREAS EXCEPT <br />WHEN ABSOLUTELY NECESSARY. CONDUIT SHALL BE STRAIGHT AND <br />PARALLEL TO BUILDING LINES. <br />L. DURING CONSTRUCTION CONDUIT SHALL BE PROTECTED AGAINST DAMAGE <br />AND ENTRANCE OF WATER, DIRT OR FOREIGN MATERIAL WITH WATERTIGHT <br />CAPS. FIRE RATED ASSEMBLIES SHALL BE PROVIDED WHERE CONDUIT <br />PASSES THROUGH FIRE RATED CONSTRUCTION. REFER TO THE <br />ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF FIRE RATED <br />CONSTRUCTION. REFER TO THE FIRE STOP PENETRATION DETAILS ON THE <br />ELECTRICAL DRAWINGS. <br />M. INSULATING BUSHINGS WITH DOUBLE LOCK -NUTS SHALL BE USED <br />WHEREVER A NEW CONDUIT 1-1/4" DIA OR LARGER ENTERS A BOX, PANEL, <br />DISCONNECT OR ELECTRICAL EQUIPMENT. <br />N. CONDUIT SIZES SHOWN ON THE DRAWINGS AND SCHEDULES ARE THE <br />MINIMUM SIZES REQUIRED. LARGER SIZE CONDUIT TO FACILITATE WIRE <br />PULLS, ETC, IS PERMITTED. <br />2.07 CONDUCTORS <br />A. PROVIDE 75 DEGREE CELSIUS (167 DEGREE FAHRENHEIT) TYPE THHW, THW, <br />THWN, OR XHHW INSULATED COPPER CONDUCTORS RATED AT 600V FOR <br />POWER DISTRIBUTION WIRING. CONDUIT WIRE FILL SHOWN ON THE <br />DRAWINGS AND FEEDER SCHEDULES ARE BASED ON TYPE THW WIRE <br />UNLESS NOTED OTHERWISE. <br />B. CONDUCTORS UP TO AND INCLUDING NO. 10 AWG SHALL BE SOLID AND <br />CONDUCTORS NO. 8 AWG AND LARGER SHALL BE STRANDED. MINIMUM <br />CONDUCTOR SIZE SHALL BE NO. 12 AWG. CONDUCTORS SHALL BE <br />CONTINUOUS BETWEEN EQUIPMENT AND DEVICES. SPLICES ARE TO BE <br />MADE ONLY IN ACCESSIBLE JUNCTION OR OUTLET BOXES AND SHOULD BE <br />KEPT TO A MINIMUM. SPLICES ON NO.12 AND NO.10 WIRE SHALL BE MADE <br />WITH PRESSURE CONNECTORS CAPABLE OF CARRYING FULL WIRE <br />CAPACITY. SPLICES ON NO.8 WIRE AND LARGER SHALL BE MADE WITH <br />SOLDERLESS LUGS WRAPPED WITH BOTH RUBBER AND PLASTIC <br />ELECTRICAL TAPE. CONNECTIONS TO FIXED EQUIPMENT TERMINALS ARE <br />TO BE MADE WITH SOLDERLESS LUGS. <br />C. ALL NEW CONDUIT USED FOR POWER DISTRIBUTION SHALL CONTAIN AN <br />EQUIPMENT GROUNDING CONDUCTOR. CONDUIT RACEWAY SHALL NOT BE <br />USED IN PLACE OF A GROUNDING CONDUCTOR. <br />D. MC TYPE CABLE MAY BE UTILIZED FOR FINAL EQUIPMENT CONNECTIONS IF <br />ALLOWED BY THE AUTHORITY HAVING JURISDICTION. MC TYPE CABLE <br />SHALL NOT BE USED FOR HOMERUNS TO PANELS. <br />E. ROMEX (NM) CABLE MAY BE UTILIZED IN ONE -AND TWO-FAMILIY DWELLINGS <br />AND MULTI -FAMILY DWELLINGS PERMITTED TO BE OF TYPES III, IV, AND V <br />CONSTRUCTION, PER NEC 334.10. <br />2.08 WIRING DEVICES <br />A. THE EXTENT OF WIRING DEVICE WORK <br />IC O K IS INDICATED ON THE DRAWINGS. <br />WIRING DEVICES ARE DEFINED AS SINGLE DISCRETE UNITS OF ELECTRICAL <br />DISTRIBUTION SYSTEMS THAT ARE INTENDED T B NOT <br />I O CARRY BUT O UTILIZE <br />ELECTRIC ENERGY. TYPES OF WIRING DEVICES IN THIS SECTION INCLUDE: <br />• RECEPTACLES <br />• GROUND FAULT CIRCUIT INTERRUPTERS <br />• ARC FAULT CIRCUIT INTERRUPTERS <br />• LIGHT SWITCHES <br />B. PROVIDE WHITE COLORED WIRING DEVICES AND MATCHING <br />THERMOPLASTIC COVERPLATES UNLESS NOTED OTHERWISE. FINAL COLOR <br />SELECTION SHALL BE COORDINATED WITH OWNER/ARCHITECT PRIOR TO <br />BID. <br />C. QUALITY ASSURANCE <br />1. NEC COMPLIANCE: COMPLY WITH NEC AS APPLICABLE TO INSTALLATION <br />AND WIRING OF ELECTRICAL WIRING DEVICES, <br />2. UL COMPLIANCE: COMPLY WITH APPLICABLE REQUIREMENTS OF U.L. 20, <br />486A, 498 AND 943 PERTAINING TO INSTALLATION OF WIRING DEVICES. <br />PROVIDE WIRING DEVICES WHICH ARE U.L. LISTED AND LABELED. <br />3. IEEE COMPLIANCE: COMPLY WITH APPLICABLE REQUIREMENTS OF IEEE <br />STANDARD 241, "RECOMMENDED PRACTICE FOR ELECTRIC POWER <br />SYSTEMS IN COMMERCIAL BUILDINGS", PERTAINING TO ELECTRICAL <br />WIRING SYSTEMS. <br />4. NEMA COMPLIANCE: COMPLY WITH APPLICABLE PORTIONS OF NEMA <br />STANDARDS PUBLICATION NUMBER WD-1, "GENERAL PURPOSE WIRING <br />DEVICES", WD-2, "SEMICONDUCTOR DIMMERS FOR INCANDESCENT <br />LAMPS", AND WD-5, "SPECIFIC PURPOSE WIRING DEVICES". <br />D. RECEPTACLES <br />1. SIMPLEX: PROVIDE SPECIFICATION GRADE 20-AMPERE, 125 VOLT, <br />HEAVY-DUTY, 2-POLE, 3-WIRE, RECEPTACLE WITH GREEN HEXAGONAL <br />EQUIPMENT GROUND SCREW AND METAL PLASTER EARS DESIGNED FOR <br />SIDE AND BACK WIRING WITH SPRING LOADED, SCREW ACTIVATED <br />PRESSURE PLATE IN NEMA 5-20R CONFIGURATION UNLESS NOTED <br />OTHERWISE. COORDINATE ALL "SPECIAL" RECEPTACLES WITH THE <br />EQUIPMENT SERVED PRIOR TO ROUGH -IN. PROVIDE RECEPTACLE <br />RATING AND CONFIGURATION TO MATCH EQUIPMENT SERVED. <br />2. DUPLEX: PROVIDE SPECIFICATION GRADE 20-AMPERE, 125 VOLT, <br />HEAVY-DUTY, 2-POLE, 3-WIRE, RECEPTACLE WITH GREEN HEXAGONAL <br />EQUIPMENT GROUND SCREW AND METAL PLASTER EARS DESIGNED FOR <br />SIDE AND BACK WIRING WITH SPRING LOADED, SCREW ACTIVATED <br />PRESSURE PLATE IN NEMA 5-20R CONFIGURATION. <br />E. GROUND -FAULT CIRCUIT INTERRUPTERS <br />1. PROVIDE SPECIFICATION GRADE "FEED-THRU" TYPE GROUND -FAULT <br />CIRCUIT INTERRUPTERS, WITH HEAVY-DUTY DUPLEX RECEPTACLES, <br />CAPABLE OF PROTECTING CONNECTED DOWNSTREAM RECEPTACLES <br />ON SINGLE CIRCUIT, AND OF BEING INSTALLED IN A 2-3/4" DEEP OUTLET <br />BOX WITHOUT ADAPTER, GROUNDING TYPE U.L. RATED CLASS A, GROUP <br />1, RATED 20-AMPERES, 120-VOLTS, 60 HZ, WITH SOLID-STATE <br />GROUND -FAULT SENSING AND SIGNALING, WITH 5 MILLIAMPERES <br />GROUND -FAULT TRIP LEVEL, EQUIP WITH NEMA 5-20R CONFIGURATION. <br />F. MANUAL LIGHT SWITCHES <br />1. PROVIDE DECORA TYPE IN FINISHED SPACES AND DWELLING UNITS. <br />COORDINATE WITH ARCHITECT/OWNER. <br />2. SINGLE AND TWO POLE: PROVIDE HARD USE SPECIFICATION GRADE <br />RECESS MOUNTED SINGLE AND TWO -POLE QUIET TOGGLE SWITCHES, <br />20-AMPERE, 120/277 VOLTS AC. PROVIDE WITH MOUNTING YOKE <br />INSULATED FROM MECHANISM, PLASTER EARS, SWITCH HANDLE, AND <br />SIDE -WIRED SCREW TERMINALS. <br />3. THREE AND FOUR WAY: PROVIDE HARD USE SPECIFICATION GRADE <br />RECESS MOUNTED 3 AND 4-WAY AC QUIET SWITCHES, 20-AMPERES, <br />120/277 VOLTS PROVIDE WITH MOUNTING YOKE INSULATED FROM <br />MECHANISM, PLASTER EARS, SWITCH HANDLE, SIDE -WIRED SCREW <br />TERMINALS, WITH BREAK -OFF TAB FEATURES, WHICH ALLOWS WIRING <br />WITH SEPARATE OR COMMON FEED. <br />2.09 LIGHTING FIXTURES <br />A. ELECTRICAL CONTRACTOR SHALL PROVIDE, WIRE AND LAMP ALL LIGHTING <br />FIXTURES SHOWN ON SITE PLAN, FLOOR PLANS AND LIGHTING FIXTURE <br />SCHEDULE. AT SUBSTANTIAL COMPLETION, ELECTRICAL CONTRACTOR <br />SHALL CLEAN DUST, DEBRIS, FINGERPRINTS, ETC FROM ALL FIXTURE <br />LENSES, LOUVERS, AND REFLECTORS AND SHALL REPLACE ALL LAMPS, <br />BALLASTS, ETC THAT ARE NOT WORKING. <br />B. ELECTRICAL CONTRACTOR SHALL REVIEW THE ARCHITECTURAL DRAWINGS <br />(SECTIONS, ELEVATIONS, DETAILS, ETC.) FOR LIGHTING FIXTURES WHICH <br />MAY BE SHOWN AND SHALL NOTIFY THE ARCHITECT/ ENGINEER PRIOR TO <br />BID IF FIXTURES APPEAR ON THE ARCHITECTURAL DRAWINGS THAT DO NOT <br />APPEAR ON THE ELECTRICAL DRAWINGS. <br />C. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL PATH OF EGRESS <br />LIGHTING AND EXIT SIGNAGE AS SHOWN ON THE PLANS AND AS REQUIRED <br />BY APPLICABLE LIFE SAFETY CODE(S). <br />2.10 LIGHTING CONTROLS <br />A. INTERIOR. PROVIDE A COMPLETE, AUTOMATIC LIGHTING CONTROLS <br />SYSTEM TO SHUT OFF INTERIOR LIGHTING IN COMPLIANCE WITH FBC <br />ENERGY SECTION C405. THE SYSTEM SHALL FUNCTION ON EITHER OF THE <br />FOLLOWING: <br />1. OCCUPANCY SENSOR(S) THAT SHALL TURN LIGHTING OFF WITHIN 20 <br />MINUTES OF ALL OCCUPANTS VACATING THE SPACE. <br />2. A SCHEDULED BASIS THAT TURNS LIGHTING OFF AT A PROGRAMMED <br />TIME OF DAY. PROVIDE INDICATION 5 MINUTES PRIOR TO TURNING <br />LIGHTING OFF TO ALLOW OCCUPANTS TO MANUALLY OVERRIDE <br />SCHEDULE. <br />B. EXTERIOR. PROVIDE TIMECLOCK(S) FOR EXTERIOR LIGHTING CONTROL, <br />TIME CLOCKS SHALL BE 7-DAY, 24-HOUR MECHANICAL OR ELECTRONIC <br />WITH CARRYOVER PROVISIONS FOR A MINIMUM OF 16 HOURS. PROVIDE <br />PHOTOCELL FOR AUTOMATIC FIXTURE SWITCHING WHERE INDICATED ON <br />SITE AND FLOOR PLANS. PHOTOCELL SHALL BE RATED FOR REQUIRED <br />LOAD AND VOLTAGE WITH BUILT-IN DELAY FOR TRANSIENT LIGHT FLASHES <br />AND LIGHT LEVEL ADJUSTMENT. <br />C. DOCUMENTS CERTIFYING THAT THE INSTALLED LIGHTING CONTROLS MEET <br />THE DOCUMENTED PERFORMANCE CRITERIA OF FBC-ENERGY SECTION <br />C405 SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS FROM <br />THE DATE OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY. <br />2.11 EQUIPMENT FURNISHED BY OTHERS <br />A. ELECTRICAL CONTRACTOR SHALL PROVIDE ELECTRICAL SERVICE TO <br />EQUIPMENT PROVIDED BY OTHERS INCLUDING, BUT NOT LIMITED TO, <br />CIRCUIT BREAKERS, CONDUIT, WIRE, DISCONNECT SWITCHES, ETC AS <br />REQUIRED BY OTHERS. <br />2.12 MOTOR CONTROLLERS <br />A. PROVIDE FULL -VOLTAGE, NON -REVERSING, ACROSS -THE -LINE, MAGNETIC <br />MOTOR CONTROLLER(S). COORDINATE THE FEATURES OF EACH MOTOR <br />CONTROLLER WITH THE RATINGS AND CHARACTERISTICS OF THE SUPPLY <br />CIRCUIT, THE MOTOR, THE REQUIRED CONTROL SEQUENCE, THE DUTY <br />CYCLE OF THE MOTOR, DRIVE, AND LOAD, AND THE PILOT DEVICE, AND <br />CONTROL CIRCUITING AFFECTING CONTROLLER FUNCTIONS. PROVIDE <br />CONTROLLERS THAT ARE HORSEPOWER RATED TO SUIT THE MOTOR <br />CONTROLLED. <br />B. CONTACTS SHALL OPEN EACH UNGROUNDED CONNECTION TO THE MOTOR. <br />C. OVERLOAD RELAYS: AMBIENT -COMPENSATED TYPE WITH <br />INVERSE -TIME -CURRENT CHARACTERISTIC. PROVIDE WITH HEATERS OR <br />SENSORS IN EACH PHASE MATCHED TO NAMEPLATE FULL -LOAD CURRENT <br />OF THE SPECIFIC MOTOR TO WHICH CONNECTED WITH APPROPRIATE <br />ADJUSTMENT FOR DUTY CYCLE. <br />D. ENCLOSURES: FOR INDIVIDUALLY MOUNTED MOTOR CONTROLLERS AND <br />CONTROL DEVICES, COMPLY WITH NEMA STANDARD 250, "ENCLOSURES <br />FOR ELECTRICAL EQUIPMENT (1000 VOLTS MAXIMUM)." PROVIDE <br />ENCLOSURES SUITABLE FOR THE ENVIRONMENTAL CONDITIONS AT THE <br />CONTROLLER LOCATION. <br />E. PROVIDE CONTROL POWER TRANSFORMER INTEGRAL WITH CONTROLLER <br />WHERE NO OTHER SUPPLY OF CONTROL POWER TO CONTROLLER IS <br />INDICATED. PROVIDE CONTROL POWER TRANSFORMER WITH ADEQUATE <br />CAPACITY TO OPERATE CONNECTED PILOT, INDICATING AND CONTROL <br />DEVICES, <br />F. COMBINATION CONTROLLER: SWITCH TYPE; FUSED, QUICK -MAKE, <br />QUICK -BREAK SWITCH, FACTORY ASSEMBLED WITH CONTROLLER AND <br />ARRANGED TO DISCONNECT IT. PROVIDE REJECTION -TYPE FUSE CLIPS AND <br />FUSES RATED PER MANUFACTURERS RECOMMENDATION. INTERLOCK <br />SWITCH WITH UNIT COVER OR DOOR. <br />G. AUXILIARY CONTROL DEVICES SHALL BE FACTORY INSTALLED IN <br />CONTROLLER ENCLOSURE. <br />H. AUTOMATIC SELECTOR SWITCHES: INSTALL IN COVERS OF CONTROLLERS <br />OF MOTORS STARTED AND STOPPED BY AUTOMATIC CONTROLS OR <br />INTERLOCKS WITH OTHER EQUIPMENT. MAKE CONTROL CONNECTIONS SO <br />ONLY THE MANUAL AND AUTOMATIC CONTROL DEVICES THAT HAVE NO <br />SAFETY FUNCTIONS WILL BE BYPASSED WHEN THE SWITCH IS IN THE HAND <br />POSITION. CONNECT MOTOR CONTROL CIRCUIT IN BOTH HAND AND <br />AUTOMATIC POSITIONS FOR SAFETY TYPE CONTROL DEVICES SUCH AS <br />"LOW"AND "HIGH" PRESSURE CUTOUTS, HIGH TEMPERATURE CUTOUTS, <br />AND MOTOR OVERLOAD PROTECTORS. MAKE CONTROL CIRCUIT <br />CONNECTIONS TO A HAND -OFF -AUTOMATIC SWITCH OR TO MORE THAN <br />ONE AUTOMATIC CONTROL DEVICE IN ACCORDANCE WITH MANUFACTURER <br />PROVIDED WIRING DIAGRAM. <br />2.13 RACEWAY FOR COMMUNICATIONS WIRING <br />A. REFER TO THE COMMUNICATIONS RISER DIAGRAM AND ELECTRICAL <br />SYMBOL LEGEND FOR ADDITIONAL REQUIREMENTS. <br />B. PROVIDE CONDUIT, BACKBOX, BLANK COVERPLATE AND PULL STRING FOR <br />EACH OUTLET INDICATED ON CONSTRUCTION DOCUMENTS. PROVIDE <br />BUSHING ON ENDS OF CONDUIT. DEVICES AND WIRING PROVIDED BY <br />OTHERS. <br />C. PROVIDE EACH CONDUIT WITH PULL STRING STUBBED FROM BACKBOX INTO <br />ACCESSIBLE CEILING SPACE (I.E., LAY -IN CEILING TILE) ABOVE EACH <br />OUTLET. <br />D. PROVIDE CONDUIT WITH PULL STRING ROUTED FROM EACH BACKBOX TO <br />CLOSEST COMMUNICATIONS BACKBOARD (OR TERMINAL CABINET) ON THE <br />FLOOR WHERE OUTLET IS LOCATED U.N.O. <br />E. PROVIDE CONDUIT, (1) 2" MINIMUM, ABOVE INACCESSIBLE CEILINGS AND <br />COVERED BREEZEWAYS. EXTEND CONDUIT INTO ACCESSIBLE CEILING <br />SPACE AT EACH END. <br />F. ROUTE CONDUIT THROUGH RATED WALLS AND FLOORS USING U.L. <br />APPROVED FIRE RATED PENETRATION MATERIALS. <br />PART 3 - EXECUTION <br />3.01 COOPERATION WITH OTHER TRADES <br />A. ELECTRICAL CONTRACTOR SHALL GIVE FULL COOPERATION TO OTHER <br />TRADES AND SHALL FURNISH IN WRITING TO THE ARCHITECT/ELECTRICAL <br />ENGINEER ANY INFORMATION NECESSARY TO PERMIT THE WORK OF <br />OTHER TRADES TO BE INSTALLED SATISFACTORILY AND WITH THE LEAST <br />POSSIBLE INTERFERENCE OR DELAY. <br />B. WHERE ELECTRICAL WORK WILL BE INSTALLED IN CLOSE PROXIMITY TO, OR <br />MAY INTERFERE WITH, WORK OF OTHER TRADES THE CONTRACTORS <br />SHALL ASSIST EACH OTHER IN WORKING OUT A SATISFACTORY SPACE FOR <br />EACH CONTRACTORS WORK. IF DIRECTED BY THE ARCHITECT/ELECTRICAL <br />ENGINEER, THE ELECTRICAL CONTRACTOR SHALL PREPARE COMPOSITE <br />WORKING DRAWINGS AND SECTIONS AT SUITABLE SCALE, NOT LESS THAN <br />1/4" = 1'-0", CLEARLY SHOWING HOW WORK IS TO BE INSTALLED IN RELATION <br />TO WORK OF OTHER TRADES. IF THE ELECTRICAL CONTRACTOR INSTALLS <br />HIS WORK BEFORE COORDINATING WITH OTHER TRADES, OR CAUSES ANY <br />INTERFERENCE WITH WORK OF OTHER TRADES, THE ELECTRICAL <br />CONTRACTOR SHALL MAKE THE NECESSARY CHANGES IN THE ELECTRICAL <br />WORK TO CORRECT THE CONDITIONS WITHOUT EXTRA CHARGE. <br />C. ELECTRICAL CONTRACTOR SHALL FURNISH TO OTHER TRADES, AS <br />REQUIRED, ALL NECESSARY TEMPLATES, PATTERNS, AND ASSEMBLY <br />DETAILS FOR THE PROPER INSTALLATION OF WORK AND FOR THE PURPOSE <br />OF COORDINATING ADJACENT WORK. <br />3.02 SCAFFOLDING, RIGGING, HOISTING <br />A. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL SCAFFOLDING, RIGGING <br />AND HOISTING NECESSARY FOR ERECTION AND DELIVERY INTO THE <br />PREMISES OF ALL ELECTRICAL EQUIPMENT. REMOVE SAME FROM <br />PREMISES WHEN NO LONGER REQUIRED. <br />3.03 EXCAVATING AND BACKFILLING <br />A. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL TRENCH AND PIT <br />EXCAVATION AND BACKFILLING REQUIRED FOR WORK UNDER THIS SECTION <br />OF THE SPECIFICATIONS, BOTH INSIDE AND OUTSIDE OF THE BUILDING, <br />INCLUDING REPAIRING OF FINISHED SURFACES, ALL REQUIRED SHORING, <br />BRACING, PUMPING, AND ALL PROTECTION FOR SAFETY OF PERSONS AND <br />PROPERTY, LOCAL OR STATE SAFETY CODES SHALL BE FOLLOWED, <br />B. IN ADDITION, THE ELECTRICAL CONTRACTOR SHALL CHECK THE <br />ELEVATIONS OF THE UTILITIES ENTERING AND LEAVING THE BUILDING. IF <br />SUCH ELEVATIONS REQUIRE EXCAVATIONS LOWER THAN THE FOOTING <br />LEVELS, THE ARCHITECT/ELECTRICAL ENGINEER SHALL BE NOTIFIED OF <br />SUCH CONDITIONS BEFORE EXCAVATIONS COMMENCE. ELECTRICAL <br />CONTRACTOR SHALL MAKE EXCAVATIONS AT THE MINIMUM REQUIRED <br />DEPTHS IN ORDER NOT TO UNDERCUT THE FOOTINGS. CONFORM TO THE <br />REQUIREMENTS OF THE STATE OF FLORIDA "TRENCH SAFETY ACT". FILLING, <br />BACKFILLING AND COMPACTION SHALL BE AS SPECIFIED IN OTHER AREAS <br />OF THE CONTRACT DOCUMENTS AND SPECIFICATIONS. <br />3.04 MATERIAL AND WORKMANSHIP <br />A. ALL MATERIALS AND APPARATUS REQUIRED FOR ELECTRICAL WORK, <br />EXCEPT AS SPECIFICALLY NOTED OTHERWISE, SHALL BE NEW, OF FIRST <br />CLASS QUALITY, AND SHALL BE FURNISHED, DELIVERED, ERECTED, <br />CONNECTED AND FINISHED IN EVERY DETAIL AND SHALL BE SO SELECTED <br />AND ARRANGED AS TO FIT PROPERLY INTO THE BUILDING SPACES. WHERE <br />NO SPECIFIC KIND OR QUALITY OF MATERIAL IS GIVEN, A FIRST CLASS <br />STANDARD ARTICLE, AS APPROVED BY THE ELECTRICAL ENGINEER, SHALL <br />BE PROVIDED. <br />B. ELECTRICAL CONTRACTOR SHALL PROCURE THE SERVICES OF AN <br />EXPERIENCED SUPERINTENDENT, WHO SHALL BE CONSTANTLY IN CHARGE <br />OF THE INSTALLATION OF THE WORK, TOGETHER WITH ALL SKILLED WORK <br />PERSONNEL, FITTERS, METAL WORKERS, WELDERS, HELPERS, AND LABOR <br />REQUIRED TO UNLOAD, TRANSFER, ERECT, CONNECT, ADJUST, START, <br />OPERATE AND TEST EACH SYSTEM. <br />C. ALL EQUIPMENT AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE <br />WITH THE RECOMMENDATIONS OF THE MANUFACTURER. THIS INCLUDES <br />THE PERFORMANCE OF ALL TESTS RECOMMENDED BY THE <br />MANUFACTURER. <br />3.05 CUTTING AND PATCHING <br />A. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CUTTING AND PATCHING <br />NECESSARY TO INSTALL ELECTRICAL WORK. PATCHING SHALL MATCH <br />ADJACENT SURFACES AND SHALL MEET THE APPROVAL OF THE ARCHITECT <br />AND OWNER. <br />B. NO STRUCTURAL MEMBERS SHALL BE CUT OR MODIFIED IN ANY WAY <br />WITHOUT THE WRITTEN APPROVAL OF THE STRUCTURAL ENGINEER. ANY <br />MODIFICATION SHALL BE DONE IN A MANNER APPROVED BY THE <br />STRUCTURAL ENGINEER. <br />3.06 SLEEVES AND PLATES <br />A. ELECTRICAL CONTRACTOR SHALL PROVIDE AND LOCATE ALL SLEEVES <br />REQUIRED FOR ELECTRICAL WORK BEFORE THE FLOORS, WALLS AND <br />CEILINGS ARE CONSTRUCTED, OR SHALL BE RESPONSIBLE FOR THE COST <br />OF CUTTING AND PATCHING WHERE SLEEVES WERE NOT INSTALLED, OR <br />WHERE INCORRECTLY LOCATED. ELECTRICAL CONTRACTOR SHALL <br />PROVIDE ALL DRILLING REQUIRED FOR THE INSTALLATION OF HIS <br />HANGERS. SLEEVES SHALL BE PROVIDED FOR ALL CONDUIT PASSING <br />THROUGH CONCRETE FLOOR SLABS ABOVE GRADE AND CONCRETE, <br />MASONRY, TILE AND GYPSUM WALL CONSTRUCTION. <br />B. CONDUIT THROUGH FLOORS AND WALLS SHALL UTILIZE A U.L. APPROVED <br />FIRE RATED PENETRATION SYSTEM. WHERE SLEEVES ARE PLACED IN <br />EXTERIOR WALLS BELOW GRADE, THE SPACE BETWEEN THE CONDUIT AND <br />THE SLEEVES SHALL BE SEALED WATERTIGHT. <br />C. WHERE CONDUIT MOTION DUE TO EXPANSION AND CONTRACTION WILL <br />OCCUR, PROVIDE SLEEVES OF SUFFICIENT DIAMETER TO PERMIT FREE <br />MOVEMENT OF THE CONDUIT. CHECK FLOOR AND WALL CONSTRUCTION <br />FINISHES TO DETERMINE PROPER LENGTH OF SLEEVES FOR VARIOUS <br />LOCATIONS. PROVIDE ACTUAL LENGTHS TO SUIT THE FOLLOWING: <br />1. TERMINATE SLEEVES FLUSH WITH WALLS, PARTITIONS AND CEILING. <br />2. IN AREAS WHERE CONDUIT IS CONCEALED, AS IN CHASES, TERMINATE <br />SLEEVES 1"ABOVE FLOOR. <br />3. IN AREAS WHERE CONDUIT IS EXPOSED, EXTEND SLEEVES 2" ABOVE <br />FINISHED FLOOR. <br />4. SLEEVES SHALL BE CONSTRUCTED OF SCHEDULE 40 STEEL PIPE. <br />D. FASTEN SLEEVES SECURELY IN FLOORS AND WALLS SO THEY WILL NOT <br />BECOME DISPLACED WHEN CONCRETE IS POURED OR WHEN OTHER <br />CONSTRUCTION IS BUILT AROUND THEM. TAKE PRECAUTIONS TO PREVENT <br />CONCRETE, PLASTER OR OTHER MATERIALS FROM BEING FORCED INTO <br />THE SPACE BETWEEN PIPE AND SLEEVE DURING CONSTRUCTION. <br />3.07 PENETRATIONS <br />A. ALL PENETRATIONS THROUGH FIRE RATED FLOORS, WALLS AND CEILINGS <br />SHALL BE PROVIDED WITH A U.L. APPROVED FIRE STOP METHOD IN <br />ACCORDANCE WITH THE FLORIDA FIRE PREVENTION CODE 7TH EDITION <br />(EFFECTIVE 12/31/2020). <br />3.08 TESTING AND PROJECT CLOSE-OUT <br />A. TESTING: FINAL TESTS SHALL BE MADE AFTER WORK HAS BEEN <br />COMPLETED. PROVIDE COPY OF FINAL TEST TO GENERAL CONTRACTOR/ <br />ARCHITECT/ ELECTRICAL ENGINEER. WHEN REQUESTED, THE ELECTRICAL <br />CONTRACTOR SHALL CONDUCT REQUIRED OPERATING TEST(S) IN THE <br />PRESENCE OF THE ARCHITECT/ELECTRICAL ENGINEER AND OTHER <br />AUTHORIZED PERSONS. <br />B. TESTS SHALL DEMONSTRATE THAT THE SYSTEM FUNCTIONS PROPERLY <br />THROUGHOUT, THAT IT IS FREE FROM GROUNDS AND SHORTS, AND THAT <br />ALL REQUIREMENTS HEREIN HAVE BEEN COMPLIED WITH. ELECTRICAL <br />CONTRACTOR SHALL PROVIDE ALL NECESSARY INSTRUMENTS AND <br />PERSONNEL FOR TESTS AND THE OWNER WILL SUPPLY THE CURRENT. <br />TESTS SHALL BE AS PRESCRIBED BY THE AUTHORITY HAVING JURISDICTION <br />AND ENGINEER AND SHALL INCLUDE MEGGER TESTS IN ACCORDANCE WITH <br />N.E.C. RECOMMENDATIONS. <br />C. CONTROLS FOR AUTOMATIC LIGHTING SYSTEMS SHALL COMPLY WITH <br />FBC-ENERGY C408.3. PRIOR TO PASSING FINAL INSPECTION, THE <br />ELECTRICAL CONTRACTOR SHALL PROVIDE EVIDENCE TO THE ENGINEER <br />THAT THE LIGHTING CONTROLS SYSTEMS HAVE BEEN TESTED TO ENSURE <br />THAT CONTROL HARDWARE AND SOFTWARE ARE CALIBRATED, ADJUSTED, <br />PROGRAMMED AND IN PROPER WORKING CONDITION IN ACCORDANCE <br />WITH THE CONSTRUCTION DOCUMENTS AND MANUFACTURER'S <br />INSTRUCTIONS. FUNCTIONAL TESTING SHALL BE IN ACCORDANCE WITH <br />FBC-ENERGY C408.3.1.1 AND C408.3.1.2 FOR THE APPLICABLE CONTROL <br />TYPE. <br />3.09 FINAL ACCEPTANCE <br />A. AFTER TESTING, A FINAL INSPECTION SHALL BE MADE BY THE GENERAL <br />CONTRACTOR / ARCHITECT/ ELECTRICAL ENGINEER AND OTHER <br />AUTHORIZED PERSONS WITH THE ELECTRICAL CONTRACTOR. THE <br />INSPECTION SHALL INCLUDE, BUT NOT BE LIMITED TO, CHECK ALL PANELS <br />ARE COMPLETE WITH NAMEPLATES AND CIRCUIT DIRECTORIES, ALL <br />LIGHTING FIXTURES ARE OPERATING, PROPERLY CLEANED AND LAMPED, <br />AND THAT ALL WORK HAS BEEN PERFORMED IN PROFESSIONAL MANNER. <br />B. FINAL ACCEPTANCE OF THE PROJECT SHALL NOT PREJUDICE THE OWNER'S <br />RIGHT TO REQUIRE REPLACEMENT AND/OR REPAIR OF ANY DEFECTIVE <br />WORK OR MATERIALS. <br />3.10 WARRANTY <br />A. ALL PARTS, MATERIALS, EQUIPMENT AND LABOR FURNISHED UNDER THIS <br />SECTION OF THE SPECIFICATIONS SHALL BEAR A ONE (1) YEAR, NO COST <br />TO THE OWNER, WARRANTY FROM THE DATE OF FINAL ACCEPTANCE. <br />ELECTRICAL CONTRACTOR SHALL PROVIDE ALL OF THE ABOVE WARRANTY <br />REQUIREMENTS IN A WRITTEN STATEMENT ALONG WITH EQUIPMENT <br />MANUFACTURER'S WARRANTIES. <br />3.11 RECORD DRAWINGS <br />A. ELECTRICAL CONTRACTOR SHALL KEEP ACCURATE RECORDS OF ACTUAL <br />CONDITIONS DEVICE INCLUDING LOCATIONS I IC AND CONDUIT RUNS WHERE <br />DIFFERENT FROM THE CONTRACT DOCUMENTS. ELECTRICAL CONTRACTOR <br />SHALL PROVIDE OWNER WITH A REPRODUCIBLE SET OF "AS BUILT" PLANS <br />SHOWING THE COMPLETE ELECTRICAL SYSTEMS AS INSTALLED (AS BUILT <br />DRAWINGS). THE SCALE ON THESE AS BUILT DRAWINGS SHALL BE NO <br />SMALLER THAN THE SCALE USED ON THE ORIGINAL PLANS. <br />END OF DIVISION 16 <br />- <br />C&K ARCHITECTS I INTERIORS <br />architecture -interior design .client services <br />AAC001629 <br />4221 WEST BOY SCOUT BLVD., SUITE 150 <br />TAMPA, FL 33607-5743 <br />813.884.2000 <br />280 WEST CENTRAL AVE. <br />WINTER HAVEN, FL33880-2957 <br />863.577.2054 <br />3. FE/ <br />\Q � <br />°\CENSF•.;e, <br />.� <br />�-, <br />Q 5083':7 <br />-0> Of <br />1./1 21;: w <br />O ° STATE OF . w <br />X\ °°. :, <br />F <br />S°°s.„R, G <br />'ON AL•E <br />z <br />0 <br />N <br />>� <br />mo <br />i <br />t <br />J <br />U_ <br />N <br />J <br />J <br />>_ ! <br />a <br />N N <br />Z <br />OI <br />I- O <br />V <br />M f <br />W <br />V <br />LU 0- C , <br />=O <br />LU O <br />.j N <br />a <br />V_ Q 1 <br />De Cm I <br />_= i <br />V en <br />W ` <br />.j <br />W 0 <br />m <br />M <br />a - <br />LO <br />ISSUED FOR: <br />PERMIT <br />PROJECT NUMBER <br />21020 <br />DATE i <br />5.5.21 <br />DRAWING NUMBER <br />i <br />C <br />. L 2 <br />EOc <br />C <br />C <br />i <br />�� <br />5 <br />C <br />5 <br />- - <br />ir II-� I IIII I 1 I _ ..11 I I 1111 I II ir. ld _I: i 1'I .i .ail. �.I.. <br />