m <br />1 <br />Q <br />1 <br />CONCRETE <br />1.1.A <br />REMOVE EXISTING AND INSTALL NEW 4" THICK, 3000 P51 CONCRETE MAILBOX PAD. <br />1.1.8 <br />ALL REMOVED CONCRETE SHALL BE SAW CUT AND PROPERLY DISPOSED OF OFF -SITE. <br />1.2.A <br />FURNISH AND INSTALL A NEW DUMP5TER PAD AND APPROACH ACK055 FROM UFA5 UNIT 6022 <br />WITH THREE NEW BOLLARDS. <br />1.3.A <br />RE -USE ALL EXISTING CONCRETE HVAC PAD(5). ANY PADS FOUND TO BE IN UNACCEPTABLE <br />CONDITION SHALL BE REMOVED AND REPLACED WITH COMPLIANT MATERIALS AND APPLIED TO A <br />CHANGE ORDER. <br />1.4.A <br />REMOVE AND REPLACE EXISTING CONCRETE 5LAB A5 REQUIRED FOR UNDER 5LAB PLUMBING <br />MODIFICATIONS AND ADDITIONS. SLAB REPAIRS SHALL BE COMPLETED WITH 5000 PSI CONCRETE. <br />2 MASONRY <br />2.1.A ALL MASONRY VENEERS AND CONCRETE PORCHES SHALL BE FRE55URE WASHED TO ELIMINATE <br />OK MINIMIZE ANY REMOVABLE SURFACE STAINS AND/OR SEDIMENT DEPOSITS IN ORDER TO <br />RESTORE THE EXISTING MATERIALS TO FULLEST EXTENT P055113LE. <br />2.2.A TUCK POINTING OF THE MORTAR JOINTS AT ALL EXISTING MA50NKY FOUNDATIONS, VENEERS, <br />RETAINING WALLS ETC. A5 NECESSARY. <br />2.4.A ALL WINDOWS AND DOOR REPLACEMENTS THAT ARE INCLUDED ARE ANTICIPATED TO BE INSTALLED <br />IN THE EXISTING MASONRY OPENING, WHERE APPLICABLE. NO REPAIRS, ENCLOSURE, WIDENING, <br />AND/OR LENGTHENING OF EXISTING MA50NKY OPENINGS HAVE BEEN INCLUDED. <br />4 ROUGH CARPENTRY <br />4.3.A REMOVAL AND REPLACEMENT UP TO 10% OF THE EX15TING ROOF SHEATHING ON ALL 5UILDING5 <br />u THAT ARE RECEIVING FULL SHINGLE REPLACEMENT HAS BEEN INCLUDED. <br />4.5.A INSTALL NEW EXTERIOR BUILDING WRAP AT ALL AREAS RECEIVING NEW EXTERIOR SIDING. <br />4.7.A REMOVE ALL EX15TING BI-FOLD (OR ACCORDION) DOORS, ASSOCIATED TRACKS AND HARDWARE. <br />PERFORM THE NECESSARY MODIFICATIONS TO RE -FRAME THE EX15TING OPENING TO <br />ACCOMMODATE NEW SINGLE OR PAIR DOORS AS INDICATED. <br />4.10.A PERFORM THE NECESSARY FRAMING MODIFICATIONS FOR UFA5 AND/OR ADA COMPLIANCE. <br />5 FINISH CARPENTRY <br />5.1.A REMOVE AND REPLACE WOOD CASING ON THE INTERIOR SIDE OF REPLACED EXTERIOR DOORS, <br />WOOD BASEBOARD AT ALL NEW OR RELOCATED INTERIOR WALL5, 5HOE MOULDING AT THE 13A5E <br />OF WALLS RECEIVING NEW VINYL FLOORING AND AT THE BA5E OF ALL CABINETS. MATCH THE <br />PROFILE OF THE EXISTING TRIM MATERIAL. <br />5.3.A REMOVE AND REPLACE ALL EXISTING 51DING, SOFFITS, FASCIA, VINYL CEILINGS, ALUMINUM BEAM <br />WRAP, ETC. AND DISPOSE OF OFF-51TE. NEW SIDING MATERIALS WILL BE RE -INSTALLED IN THESE <br />AREAS USING THE SPECIFIED MATERIALS IN STANDARD SIZE, COLOR, AND STYLE. <br />5.3.8 UPON REMOVAL OF THE EXISTING FASCIA METAL, ALL EXISTING BAND B0ARD5 SHALL BE <br />INSPECTED FOR ROT DAMAGE. ANY DAMAGED BOARD SECTIONS SHALL BE DOCUMENTED AND <br />REMOVED AND REPLACED AS NECESSARY. DUE TO THE INABILITY TO A55ES5 THE DAMAGE UNTIL <br />THE REMOVAL OF THE FASCIA OCCURS, NO PROVISIONS HAVE BEEN INCLUDED FOR 5UB-FASCIA <br />REPLACEMENT. ANY SUB -FASCIA REQUIRING REPLACEMENT WILL BE DOCUMENTED AND <br />REFLECTED ON A CHANGE ORDER <br />5.6.A REMOVE AND REPLACE ALL EXISTING VENT PIPING COVERS FOR ANY RANGE HOODS, BATH VENTS, <br />AND/OR DRYER VENTS. ALL NEW VENT COVERS SHALL BE 51ZED ACCORDINGLY TO FIT THE <br />EXISTING PIPING AND SHALL BE IN A COLOR AS SELECTED TO MATCH THE EXTERIOR COLOR <br />SCHEME. <br />7 INSULATION <br />7.1.A ADDITIONAL ATTIC INSULATION SHALL BE INSTALLED TO THE PROPER THICKNE55 IN ORDER TO <br />pQ MEET THE MINIMUM RATING OF R-38. <br />7.1.8 INSULATION R-VALUE RATING CARDS AND PAPER RULERS SHALL BE INSTALLED IN THE ATTIC <br />ADJACENT TO THE ATTIC ACCE55 OPENING AS REQUIRED FOR VERIFICATION PURP05E5. <br />8 ROOFING <br />8.1.A REMOVE AND REPLACE ALL ASPHALT SHINGLES ON ALL 13UILDING5. (WITH THE EXCEPTION OF <br />BLDG. F) NEW SHINGLES SHALL BE A MINIMUM 30-YEAR ARCHITECTURAL, ANTI -FUNGAL SHINGLE <br />IN A STANDARD COLOR AS SELECTED BY THE OWNER. <br />8.1.0 NEW 15# ROOF FELT PAPER AND VALLEY FLASHING/ICE GUARD WILL BE INSTALLED IN <br />CONJUNCTION WITH ANY AND ALL ROOF SHINGLE REPLACEMENT. <br />8.2.A ALL BUILDINGS RECEIVING SHINGLE REPLACEMENT, SHINGLE -OVER TYPE RIDGE VENTS SHALL BE <br />fN5TALLED AS REQUIRED TO PROVIDE PROPER ATTIC VENTILATION. <br />9 SHEET METAL <br />9.1.A GUTTERS AND DOWNSPOUTS SHALL BE ADDED TO THE FRONT AND BACK SIDES OF ALL <br />BUILDING5. <br />9.1.8 NEW GUTTERS SHALL BE 6" AND ALL DOWNSPOUTS SHALL BE 3" X 4". <br />9.1.0 FURNISH AND INSTALL CONCRETE SPLASH BLOCKS AT ALL DOWNSPOUT LOCATIONS. <br />ra <br />10 DOORS & HARDWARE <br />3 <br />0 <br />SCOPE OF WORK <br />10.1.A REMOVE AND REPLACE ALL EXTERIOR DOORS. AT THE OFFICE AND LAUNDRY BUILDING5, <br />REPLACEMENT DOOK55HALL BE 9-LITE (HALF GLASS). (3 OF THIS TYPE AT OLM) <br />10.1.E NEW EXTERIOR DOORS WILL BE 51ZED TO MATCH THE EXISTING. EXTERIOR DOORS AT UFA5 UNITS <br />AND COMMUNITY SPACES SHALL BE A MINIMUM OF 3'-O" WIDE AS REQUIRED BY CODE. <br />RE -FRAMING OF THE EXISTING OPENINGS 15 INCLUDED AS NECE55ARY AT EXISTING UFAS UNIT OR <br />COMMUNITY SPACE LOCATIONS WHERE THE EXISTING DOOR 15 LE55 THAN THIS REQUIRED WIDTH <br />10.1.G ANY EXISTING STORM DOORS WILL 5E REMOVED AND STOKED ON-51TE OR DISPOSED OF OFF-51TE <br />AS DIRECTED BY THE OWNER. RE -INSTALLATION OF THESE DOORS 15 NOT INCLUDED. <br />10.2.13 ALL EXISTING 51-FOLD CL05ET DOORS WILL 13E REMOVED AND REPLACED WITH SINGLE OR PAIR <br />DOORS AS REQUIRED TO MATCH THE EXISTING OPENING. <br />10.3.E ROUND, PLASTIC; WALL MOUNTED DOOR 5TOP5 SHALL BE INSTALLED FOR ALL DOORS WHERE <br />APPLICABLE. HINGE MOUNTED DOOR STOPS WILL BE INSTALLED WHERE WALL MOUNTED ARE NOT <br />PRACTICAL. IN CASES WHERE HINGE 5TOPS ARE INSTALLED, "HALF-MOON" FLAT PLASTIC WALL <br />5TOP5 WILL BE INSTALLED ON THE DOOR AT THE HINGE STOP LOCATION IN ORDER TO PROTECT THE <br />HOLLOW CORE DOOR FROM 1`05515LE DAMAGE. <br />10.3.F THE KEYING SYSTEM FOR ALL DOOR HARDWARE SHALL BE A MASTER KEY 5Y5TEM. (SEE <br />SPECIFICATIONS) <br />10.3.1-1 ALL UNIT ENTRY DOORS SHALL 5E EQUIPPED WITH A SINGLE CYLINDER DEADBOLT WITH AN <br />INTERIOR THUMB LATCH, A PASSAGE LOCK FOR THE HANDLE, AND PEEP HOLES AT THE FRONT <br />UNIT ENTRY DOOR. DOUBLE PEEP HOLES WILL BE INSTALLED AT UFA5 UNITS WITH ONE AT <br />STANDARD HEIGHT AND ANOTHER AT THE UFA5 COMPLIANT HEIGHT. <br />11 WINDOWS <br />11.1.A REMOVE AND REPLACE ALL EXTERIOR WINDOW5. REPLACEMENT WINDOWS SHALL BE VINYL, <br />SINGLE HUNG OR 5LIDER WINDOWS WITH INSULATED GLA55 AND GBG PATTERNS AS SELECTED <br />BY THE OWNER. <br />11.2.A CASEMENT TYPE WINDOWS MAY BE REQUIRED WHEN REPLACING WINDOWS IN OFENINC75 <br />SURROUNDED BY BRICK VENEER IN ORDER TO MEET EGRE55 REQUIREMENTS AND TO AVOID <br />EXCESSIVE MODIFICATIONS TO THE EX15TING OPENING AND MASONRY DEMOLITION/REPAIRS. <br />13 DRYWALL <br />13.1.A ALL DRYWALL AT WALLS AND CEILINGS SHALL BE PROPERLY PATCHED TO REPAIR ANY EX15TING <br />DAMAGE, HOLES, SCRATCHES, ETC. <br />13.2.A DRYWALL REMOVAL AROUND EX15TING TUB5 WILL BE REQUIRED FOR TU13/5HOWER REPLACEMENT. <br />THESE AREAS ARE TO BE PROPERLY PATCHED USING MOLD RESISTANT DRYWALL THAT 15 <br />PROPERLY FINISHED, SANDED, AND PREPARED FOR PAINTING. FURRING STRIPS SHALL BE <br />INSTALLED AS REQUIRED TO CREATE A 900 OUTSIDE CORNER ANGLE AT THE COMMON TUB END <br />WALLS WHERE THE 5HEETROCK MUST LAP OVER THE TUB FLANGE. TH15 MUST BE INSTALLED IN <br />EFFORT TO PREVENT THE FORMATION OF AN OBTU5E ANGLE AT THESE LOCATIONS. <br />13.3.A ALL AREAS WHERE EXISTING WALLS ARE RELOCATED OR NEW WALLS ARE CONSTRUCTED DUE TO <br />REQUIRED UFA5 AND/OR ADA MODIFICATIONS SHALL RECEIVE NEW DRYWALL. <br />13.3.5 ALL DRYWALL SHALL BE OF THE APPROPRIATE THICKNE55 AND HAVE THE CORRECT FIRE RATING <br />IN ACCORDANCE WITH THE UL A55EM13LY FOR THE ASSOCIATED WALL/CEILING DESIGN. <br />16 RESILIENT FLOORING <br />16.1.A REMOVE AND REPLACE ALL EXISTING RESILIENT FLOORING IN ALL UNIT KITCHENS, 13ATHROOM5, <br />LAUNDRY ROOMS, AND UNIT ENTRY MUD MATS. <br />16.1.0 WHITE VINYL TUB STRIPS SHALL BE INSTALLED AT ALL TUB5 TO SEAL THE EDGE OF THE NEW VINYL <br />FLOORING. <br />16.2.A REMOVE AND REPLACE ALL EXISTING RESILIENT FLOORING. TYPICAL AREAS WHERE RESILIENT <br />FLOORING 15 INSTALLED INCLUDES THE COMMUNITY KITCHEN AREA, COMMUNITY RE5TROOM5, AND <br />COMMUNITY LAUNDRY ROOMS. <br />17 PAINTING & DECORATING <br />17.1.A UPON COMPLETION OF ALL DRYWALL PATCHING, REPAIRS, AND INSTALLATION, PAINT ALL UNIT AND <br />COMMUNITY AREA INTERIORS IN THEIR ENTIRETY. THI5 INCLUDES ALL NEW AND EX15TING DRYWALL, <br />INTERIOR TRIM AND INTERIOR DOORS. <br />17.1.8 PAINTING SHALL CONSIST OF ONE (1) COAT OF PAINT ON ALL SURFACES. <br />17.1.E CAULKING OF ALL NEW AND EX15TING TRIM SHALL BE PERFORMED AS REQUIRED USING INTERIOR <br />LATEX CAULKING TO FILL ALL TRIM JOINTS, NAIL HOLES, TUB SURROUND5, ETC. <br />17.2.A APPLY NEW PAINT FIN15H TO ALL EXTERIOR DOORS, WOOD COLUMNS, AND FIBER -CEMENT SIDING <br />OR TRIM. <br />17.2.0 CAULKING OF ALL NEW AND EXISTING DOORS, TRIM, ETC. SHALL BE COMPLETED A5 REQUIRED <br />USING EXTERIOR 51LICONE 13A5ED PAINTABLE CAULKING. <br />18 SPECIALTIES <br />18.1.A FURNISH AND INSTALL NEW TOILET ACCESSORIES INCLUDING ALL TOWEL BAK5, TOILET PAPER <br />HOLDERS, PAPER TOWEL DISPENSERS (AT COMMUNITY BATHROOMS ONLY), SHOWER RODS, <br />MEDICINE CABINETS, VANITY MIRRORS, AND GRAB BAR5 (AT UFA5 / ADA BATHROOMS ONLY). <br />18.2.A AT ALL NEWLY INSTALLED RANGE HOODS, INSTALL A PAIR OF CANISTER TYPE FIRE 5UPPRE55ER5 <br />(I.E. STOVE TOP FIRE STOP) AND CENTER OVER THE STOVE EYES PER THE MANUFACTUKEK'5 <br />INSTALLATION INSTRUCTIONS. <br />18.2.8 IN CA5E5 WHERE MICROHOODS ARE INSTALLED IN LIEU OF RANGE HOODS, INSTALL MICKOHOOD <br />TYPE FIRE 5UFFRE55ERS IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION <br />INSTRUCTIONS. <br />18.3.A FURNI5H AND INSTALL NEW PEDESTAL MOUNTED MAILBOXES AT THE LOCATION. <br />18.4.A FURNISH AND INSTALL BUILDING AND UNIT 51GNAGE AS REQUIRED BY LOCAL JURISDICTION <br />REQUIREMENTS. <br />20 CABINETRY <br />20.1.A REMOVE AND REPLACE EXISTING CABINETRY IN ALL UNIT AND COMMUNITY AREAS, UNIT <br />BATHROOM5, AND COMMUNITY LAUNDRY ROOMS. ALL NEW CABINET5 ARE TO BE CONSTRUCTED IN <br />COMPLIANCE WITH THE ARCHITECTURAL 5PECIFICATION5. ALL NEW CABINETRY SHALL HAVE A <br />COUNTERTOP HEIGHT OF 50" A.F.F AT TYPICAL UNITS AND 34' AT UFA5 UNITS AND COMMUNITY <br />AREAS. <br />20.1.0 NEW CABINET DOORS AND DRAWERS IN UFA5 UNITS AND THE COMMUNITY AREAS SHALL HAVE "D" <br />PULLS INSTALLED AS REQUIRED. <br />20.1.F WHERE RANGE HOODS OR MICKOHOOD5 ARE VENTED, A FIELD CONSTRUCTED ENCL05UPIE SHALL <br />BE INSTALLED TO CONCEAL ANY EXPO5ED VENT PIPING. THI5 ENCLOSURE SHALL BE <br />CONSTRUCTED FROM FACTORY FURNISHED MATERIALS FINISHED TO MATCH THE NEW CABINETRY. <br />21 APPLIANCES <br />21.1.A REMOVE AND REPLACE ALL EXISTING KITCHEN APPLIANCES IN ACCORDANCE WITH THE UNIT MATRIX <br />AND CAPEX HISTORY. <br />21.2.A REMOVE AND REPLACE EXISTING PROPERTY OWNED LAUNDRY EQUIPMENT WITH NEW COIN <br />OPERATED WASHERS AND DRYERS. APPLIANCES WILL BE CONFIGURED TO MEET ADA STANDARDS <br />AS REQUIRED. <br />22 BLINDS, SHADES, & ARTWORK <br />22.A REMOVE AND REPLACE ALL EXISTING WINDOW BLINDS. NEW 13LIND5 SHALL BE 1" VINYL MINI BLINDS <br />IN A STANDARD COLOR AS SELECTED BY THE OWNER. <br />23 CARPET <br />23.1.A REMOVE AND REPLACE ALL UNIT CARPET AND PADDING (WHERE APPLICABLE). TYPICAL CARPETED <br />AREAS INCLUDE LIVING ROOMS, BEDROOM5, BEDROOM CLOSETS, HALLWAYS, HALLWAY CLOSETS, <br />AND INTERIOR STAIRS. <br />23.1.13 CARPET IN ALL NON-UFA5 UNITS SHALL BE INSTALLED OVER PADDING A5 SPECIFIED AND <br />SECURED WITH EDGE TACK 5TKIP5. <br />23.1.1) NEW CARPET FOR UFAS UNITS SHALL 13E A GLUE -DOWN TYPE CARPET WITH A UNITARY BACKING. <br />ALL GLUE -DOWN CARPETING WILL BE INSTALLED DIRECTLY TO THE CONCRETE 5LAB OR GYP-CRETE <br />SUB -FLOOR WITH NO PADDING. <br />23.1.E ALL CARPET TO RESILIENT TRANSITIONS SHALL RECEIVE A VINYL TRANSITION STRIP IN A <br />STANDARD COLOR AS SELECTED BY THE OWNER. <br />23.2.A REMOVE AND REPLACE ALL OFFICE / COMMUNITY SPACE CARPET WITH A GLUE -DOWN TYPE CARPET <br />WITH A UNITARY BACKING. ALL GLUE -DOWN CARPETING WILL BE INSTALLED DIRECTLY TO THE <br />CONCRETE SLAB WITH NO PADDING, <br />26 PLUMBING <br />26.1A REMOVE AND REPLACE ALL EXISTING PLUMBING FIXTURES INCLUDING THE FOLLOWING AS <br />INDICATED ON THE UNIT MATRIX: <br />i KITCHEN SINK AND FAUCET <br />1i BATHROOM VANITY SINK AND FAUCET <br />III WATER CL05ET (STANDARD HEIGHT WITH ELONGATED 15OWL5, EXCEPT AT UFA5 UNITS) <br />1v TUB/SHOWERS VALVES, CONTROLS, TRIM, OVERFLOW AND SHOWER HEAD FOR ALL UNITS. THE <br />EX15TING TUBS AND CERAMIC TILE SURROUNDS SHALL REMAIN IN ALL UNITS EXCEPT FOR THE <br />UFAS UNITS. TUB/5HOWER FOR UFA5 UNITS 5HALL BE FULLY REPLACED WITH NEW FIBERGLA55 <br />TU13/5HOWER5 AND WILL RECEEVE GRAB BARS 5ECURILY FASTENED TO SOLID BLOCKING, OFFSET <br />CONTROLS, HAND HELD SHOWER HEADS WITH ADJU5TA13LE MOUNTING ROD AND BRACKET5 AND <br />FOLDING REMOVABLE SEAT WHERE APPLICABLE BY CODE. <br />v WATER HEATERS (CAPEX INDICATES RECENT REPLACEMENT OF 12 EACH - SEE MATRIX) <br />RESIDENTIAL WATER HEATERS SHALL BE 40 GALLON, ELECTRIC, LOW BOY TYPE AND HAVE AN <br />ENERGY EFFICIENCY RATING OF 0.95. THE WATER HEATER FOR THE LAUNDRY SHALL BE 80 <br />GALLON ELECTRIC. ALL RESIDENTIAL WATER HEATERS SHALL BE INSTALLED IN NEW PLASTIC <br />PANS PIPED INTO THE BELL HUB DRAIN. <br />vi EXTERIOR H05E 13I135 <br />A WASHING MACHINE CONNECTIONS (WHERE APPLICABLE) <br />viii MOP/LAUNDRY SINK (MAINTENANCE ROOM) <br />26.1.E ALL EX15TING PIPING AT KITCHEN AND BATH VANITIES IN UFA5 UNITS AND COMMUNITY <br />BATHKOOM5 WILL BE REWORKED IN ORDER TO ALLOW THE PROPER KNEE SPACE CLEARANCES AS <br />REQUIRED BY CODE. <br />26.1.F INSULATED PIPE GUARDS WILL BE INSTALLED ON ALL EXF05ED WASTE LINES AT UFA5/ADA SINKS <br />AND VANITIES. <br />26.1.G DURING THE INITIAL SITE INSPECTION, IT WAS NOTED THAT THE EXISTING PLUMBING SUPPLY LINES <br />WERE POLYBUTYLENE. THE EXISTING LINES SHALL BE ABANDONED AND/OR REPLACED AS <br />REQUIRED BY THE ARCHITECTURAL 5PECIFICATION 5. <br />27 HEAT & VENTILATION <br />27.1.A REMOVE AND REPLACE ALL EXISTING CONDENSER UNITS, AIR HANDLERS, REGISTERS, GRILLS, AND <br />THERMOSTATS. <br />27.1.E NEW THERMOSTATS SHALL BE A DIGITAL, NON -PROGRAMMABLE TYPE AS MANUFACTURED BY <br />HONEYWELL OR EQUAL. <br />27.1.F ALL EXISTING DUCTWORK AND FRENN LINES ARE TO REMAIN AND WILL BE TIED IN TO THE NEW <br />HVAC EQUIPMENT. <br />27.1,G REMOVE AND REPLACE ALL EXISTING BATHROOM VENTILATION FANS AND TIE-IN TO THE EXISTING <br />VENT PIPING. NEW VENTILATION FANS SHALL BE 50 CFM AND SHALL BE ENERGY STAR RATED. <br />27.1.H REMOVE AND REPLACE ALL LAUNDRY ROOM DRYER VENT PIPING IN THE COMMUNITY LAUNDRY <br />ROOM. <br />27.1.1 NEW CONDENSATE LINES WILL BE TIED INTO EXISTING HUB DRAIN OR PIPING TO THE EXTERIOR. <br />27.1.J INSTALL NEW ELECTRIC WALL HEATER (UP TO 5KW) IN THE COMMUNITY LAUNDRY ROOM. <br />5 <br />29 ELECTRICAL <br />29.1.A REMOVE AND REPLACE ALL EXISTING INTERIOR AND EXTERIOR LIGHT FIXTURES AND REPLACE WITH <br />ENERGY STAR RATED FIXTURES WHERE APPLICABLE. INSTALL NEW CFL LIGHT 1 ULB5 IN ALL <br />FIXTURES. <br />29.1.13 REMOVE AND REPLACE ALL EXISTING SWITCHES, RECEPTACLES, GFI'S AND COVERS. NEW DEVICES <br />AND COVERS SHALL BE 5TANDARD OFF-WHITE IN COLOR AND MEET ALL NEC REGULATIONS. <br />29.1.0 INSTALL CABLE TV WIRING TO ALL BEDROOMS WHERE NO CABLE TV CONNECTIONS CURRENTLY <br />EXIST. <br />29.1.1) LOWER ALL EXISTING ELECTRICAL PANELS IN UFA5 UNITS AS REQUIRED TO COMPLY WITH UFA5 <br />STANDARDS. <br />29.1.E REPLACE EXISTING OR INSTALL NEW DISCONNECTS AT NEW WATER HEATERS. <br />29.1.F CONNECT ALL WIRING AS REQUIRED FOR ALL REPLACED APPLIANCES, PLUMBING, AND ELECTRICAL <br />FIXTURES AS REQUIRED. EXISTING RECEPTACLES FOR RANGES AND/OR DRYERS ARE TO BE <br />CHANGED TO A CODE COMPLIANT 4-PRONG RECEPTACLE AS REQUIRED <br />29.1.G UPGRADE ELECTRICAL 15REAKER5 A5 NECESSARY FOR NEW HVAC EQUIPMENT. <br />29.1.H RE -LABEL ALL ELECTRICAL PANELS TO INDICATE THE NEW WIRING AND BREAKER FEEDS. <br />29.1.1 ADD HARDWIRED SMOKE DETECTORS AS REQUIRED BY NEC 50 THAT DETECTORS EXI5T IN ALL <br />13EDROOM5, IN THE HALLWAY OUTSIDE OF THE BEDROOMS, AND AS REQUIRED FOR THE <br />COMMUNITY 5PACE(5). <br />29.1.J ALL EXISTING UTILITY 13OXE5, CONDUITS, AND CABLES AT THE BUILDING EXTERIOR WILL BE <br />RE -SECURED AS NECESSARY. <br />29.2.A EXISTING 51TE LIGHTS ARE OWNED AND SERVICED BY LOCAL UTILITY COMPANY. ANY REPAIRS OR <br />REPLACEMENT OF THESE LIGHTS HAS BEEN EXCLUDED. <br />29.2.8 FURNISH AND INSTALL SOLAR POWERED LIGHTING TO PROPERTY ENTRANCE SIGN. <br />29.3.A FURNISH AND INSTALL NEW SMOKE DETECTORS WITH 5TRO13E5 AND HORN/STROBES TIED TO THE <br />EXISTING DOORBELL FOR THE DESIGNATED HEARING & V15UAL IMPAIRED UNIT. <br />31 ON -SITE UTILITIES <br />31.1.A ALL EXISTING 51TE UTILITIES ARE PRESUMED TO BE FUNCTIONING PROPERLY AND ARE FREE OF <br />LEAKS, P>LOCKAGE5, DEBRIS, ETC. <br />31.2.A ALL EX15TING UNITS AND/OR 15UILDING5 ARE PRESUMED TO HAVE PROPERLY SEALED, CONNECTED, <br />AND WORKING VALVES, SHUT -OFFS, MANIFOLDS, ETC. ALSO, THE EXISTING WATER FRE55URE IS <br />PRESUMED TO BE AT AN ACCEPTABLE LEVEL AND/OR FRE55URE REDUCING VALVES (PRV'S) HAVE <br />BEEN PREVIOUSLY INSTALLED WHERE NECESSARY. THESE ITEMS WILL BE INSPECTED DURING THE <br />COURSE OF THE REHAB AND ANY NECESSARY REPAIRS, REPLACEMENTS, AND/OR ADDITIONS WILL <br />BE COMPLETED AND REFLECTED ON A CHANGE ORDER. <br />31.4.A ALL EXISTING SANITARY SEWER MAINS AND LATERALS ARE PRESUMED TO BE FREE OF <br />013STRUCTION5 AND CURRENTLY FUNCTIONING PROPERLY. ANY D15COVERED 155UE5 SHALL BE <br />INSPECTED AND REQUIRED MEASURES WILL BE PERFORMED TO RESTORE PROPER DRAINAGE AND <br />WILL BE REFLECTED ON A CHANGE ORDER. <br />32 ROADS AND WALKS <br />32.1.A FRE55URE WASH ALL ROADS AND PARKING LOT AREAS TO REMOVE ANY 5EDIMENT AND SURFACE <br />DEBRIS. <br />32.2.A REMOVE ANY DAMAGED 5ECTION5 OF CONCRETE IN ACCORDANCE WITH THE DRAWINGS AND MAKE <br />THE NECESSARY REPAIRS TO THE UNDERLYING STONE BASE TO REGAIN STRUCTURAL 5TA13ILITY. <br />32.5.A LAYOUT AND STRIPE ALL NEW STANDARD AND ACCE55113LE PARKING SPACES AS INDICATED ON <br />THE DRAWINGS. ALSO, 5TRIPE ALL ACCESS AISLES AND CR055WALK5 IN ACCORDANCE WITH <br />UFA5 / ADA REQUIREMENTS. <br />32.6.A FURNISH AND INSTALL ALL REQUIRED 51GNAGE FOR ACCE55113LE AND VAN ACCE55113LE PARKING <br />SPACES. <br />32.68 NEW 51GNAGE SHALL BE INSTALLED AT THE APPROPRIATE HEIGHTS, DI5TANCE5, AND LOCATIONS <br />IN COMPLIANCE WITH UFA5 / ADA REQUIREMENT5. <br />32.6C NEW SIGNAGE SHALL BE MOUNTED ON PRE -FINISHED METAL SIGN POST5, EMBEDDED IN A <br />CONCRETE 13A5E BELOW GRADE. <br />32.7A FURNISH AND INSTALL ALL REQUIRED STOP SIGNS, NO PARKING SIGNS, ETC. <br />32.6.A PROVIDE REMOVAL, REPLACEMENT, AND D15PO5AL OF ANY EXISTING AND/OR NEW 51DEWALK5, <br />CURBS, HANDICAPPED RAMPS, PARKING 5PACE5, AND CROSSWALKS THAT ARE DAMAGED, NON <br />UFAS/ADA COMPLIANT, AND/OR INDICATE EVIDENCE OF A TRIP HAZARD <br />32.5.13 NEW CONCRETE SHALL BE A MINIMUM OF 3000 P51 AND 15 TO RECEIVE A LIGHT BROOM FINISH. <br />33 ON -SITE IMPROVEMENTS <br />33.1.A REMOVE EXf5TING AND INSTALL NEW DUMPSTEK FENCING AT ALL DUMP5TER PAD LOCATIONS. <br />33.1.0 INSTALL STEEL BOLLARD5, AS INDICATED ON THE DRAWINGS, AT THE BACK OF THE NEW <br />DUMP5TEK PAD LOCATIONS. ALL BOLLARDS SHALL HAVE MINIMUM 4' OUTSIDE DIAMETER, FILLED <br />SOLID WITH CONCRETE, AND PAINTED. <br />33.2.A REMOVE AND REPLACE EXISTING PLAYGROUND EQUIPMENT AT EXISTING LOCATION. PLAYGROUND <br />SHALL INCLUDE ALL EQUIPMENT, MULCH BEDDING AND BORDERS. <br />33.3.A REMOVE THE EXISTING PROPERTY SIGNAGE AND REPLACE WITH NEW 51GNAGE, REUSE EXISTING <br />MA50NKY 5UKROUND/COLUMNS. <br />33.4.A REPAIR EXISTING PERIMETER SITE FENCING. THE EXISTING WOOD FENCE 5EPARATING THIS <br />PROPERTY FROM VILLAGE CHASE APARTMENTS, 5HALL BE REMOVED. <br />53.4.13 REMOVAL OF THE EX15TING FENCING BEHIND THE OLM AND INSTALLATION OF VINYL FENCING, WITH <br />A DOUBLE GATE, AROUND THE EXISTING MAINTENANCE SHELTER HAS BEEN INCLUDED. <br />33.8.A INSTALL NEW ALUMINUM OR EPDXY COATED 51TE BENCHES ALONG THE SIDEWALKS AND <br />ACCESSIBLE PATH. <br />33.8.8 ALL NEW 13ENCHE5 ARE TO RECEIVE NEW CONCRETE PAD PER DRAWINGS. <br />34 LAWNS AND PLANTINGS <br />34.1A PROVIDE LANDSCAPING INCLUDING THE INSTALLATION OF NEW PLANTS, TREES, 50D, SITE <br />DRAINAGE REPAIR5, BACKFILLING, AND GRASS AND/OR 501). <br />U <br />0 <br />ivuk_,ritini. J. iu nrrivnic <br />ARCHITECT <br />LICENSE #96387 <br />WALLACE ARCHITECTS, L.L.C. <br />ffCOPYRIGHT C 2015 <br />T ISSUE <br />OV 2015 <br />REVISIONS <br />SHEET NO. <br />scilo <br />2 <br />3 <br />II <br />5 <br />JOB NO. <br />3139B <br />