Laserfiche WebLink
3 <br />d <br />0 <br />CV <br />cn <br />cj <br />C3 <br />0 <br />0 <br />cV <br />O <br />cV <br />0 <br />z <br />W <br />0 <br />n• <br />SCALE: 1 /4"=1'-O" <br />GENERAL NOTES <br />1. REFER TO ARCHITECTURAL DRAWINGS FOR WALL HEIGHTS. <br />2. REFER TO STRUCTURAL DETAILS FOR STEPPED MASONRY WALL <br />HEIGHT DETAIL <br />3. ALL INTERIOR CEILING SHEATHING TO BE GYPSUM. <br />4. ALL EXTERIOR SHEATHING TO BE MINIMUM 7/16 " APA RATED <br />SHEATHING. <br />5. FLOOR SHEATHING (IF APPLICABLE) SHALL BE 2�; MIN. <br />6. REFER TO DETAILS FOR ROOF SHEATHING REQUIREMENTS. <br />7. U.N.O. INTERIOR SHEATHING TO BE GYPSUM AS REQUIRED IN <br />ARCHITECTURAL DRAWINGS. <br />8. PROVIDE SOLID BLOCKING FROM ALL BEAMS & GIRDERS TO <br />FOUNDATION BELOW. <br />TRUSS NOTES <br />UNLESS OTHERWISE NOTED ON PLANS: <br />1. ALL TRUSS STRAPS TO MASONRY ARE TO BE META16. <br />2. ALL TRUSS TO FRAME SCREWS ARE TO BE THE FOLLOWING: <br />A) TRUSS TO TOP PLATE TO BE (2) SIMPSON SDWC15600. <br />B) MULTI -PLY TRUSS REQUIRE (2) SDWC15600 AT EA PLY. <br />C) (1) SDWC15600 MAY BE USED ON JACK TRUSSES. <br />3, THESE PLANS ARE ENGINEERED BASED ON TRUSS LAYOUTS AND <br />ENGINEERING PROVIDED BY THE DELEGATED TRUSS ENGINEER. <br />CHANGES OR MODIFICATIONS ARE NOT PERMITTED WITHOUT A <br />LETTER FROM THE ENGINEER OF RECORD. <br />LEGEND <br />DETAIL INDICATOR <br />SHT <br />CROSS HATCHED AREA INDICATES EXTENT OF <br />GABLE END BRACING <br />TRUSS LAYOUT SHOWN ON THIS SHEET IS FOR EXAMPLE <br />PURPOSES ONLY TO ILLUSTRATE TRUSS TO WALL CONNECTIONS. <br />THIS LAYOUT HAS BEEN PROVIDED BY A THIRD PARTY FOR <br />EXAMPLE PURPOSES ONLY; THE ACTUAL TRUSS MANUFACTURER <br />LAYOUTS ARE TO BE USED FOR ALL STRAP LOCATIONS. PER <br />BUILDING CODE STATUTES, THE ROOF AND/OR FLOOR SYSTEM <br />HAS BEEN DELEGATED TO THE TRUSS MANUFACTURER'S <br />PROFESSIONAL ENGINEER. <br />C.Q.A.# ARCHITECTURE; <br />AA26002802 <br />C.O.A.# ENGINEERING: <br />29349 <br />El THOMAS A. WEBER, PE <br />P.E. # 73242 FLORIDA <br />® BENJAMIN NIESE, PE <br />P.E. # 86025 FLORIDA <br />11 /30/20 <br />oaTe <br />No. o <br />OF 4 <br />ED <br />0- <br />CD <br />cV <br />O <br />CV <br />0 <br />U <br />O <br />W <br />o� <br />c ?1 <br />e--{ <br />OQ <br />M <br />� <br />O <br />r ^ <br />VJ00 <br />O <br />♦ <br />O <br />n� <br />�-1 <br />O <br />t� <br />U <br />cir) <br />�' <br />�s <br />a�7-4 <br />-(=5 <br />;--4 <br />� <br />bio <br />C� <br />as <br />N <br />as <br />*Pulte:""', <br />PRODUCT MANAGER <br />RELEASE <br />DATE: XX/XX/XXXX <br />PROJECT TYPE I Single Family <br />SPECIFICATION LEVEL I <br />Pulte <br />PLAN NAME <br />Highgate <br />NPC CHIM NU ER <br />2811.500 <br />SHEET <br />S3.1 <br />