3 <br />0 <br />0 <br />0 <br />U <br />U <br />O <br />CV <br />0 <br />N <br />c <br />0 <br />z <br />w <br />0 <br />a <br />CONTINUOUS STRUCTURAL <br />TRUSS ANCHOR PER PLAN <br />STRUCTURAL SHEATHING <br />SEE PLAN AND DETAILS FOR <br />ATTACHMENT <br />DETAIL AT RAISED HEEL <br />PRE-ENGINEERED WOOD TRUSSES AT 2'-0" O.C. MAX. <br />TRUSS ANCHOR PER PLAN <br />FASCIA <br />SEE ARCH. DRAWINGS <br />2x BLOCKING AT <br />SHEATHING EDGES <br />NOTE: <br />REFER TO ARCHITECTURAL <br />DRAWINGS AND/ OR TRUSS <br />MANUFACTURER DRAWINGS FOR <br />rnrnin; TRUSS PROFLE <br />NTION. (i.e. HEEL . <br />SLOPE, OVERHANGS). <br />Vr— ' SHEATHING PER PLAN <br />BOND BEAM PER PLAN <br />R01 ROOF TRUSS ON MASONRY <br />Z <br />O <br />Q <br />z <br />o * <br />z¢ <br />o <br />STRUCTURAL SHEATHING CONTINUOUS <br />AT TRUSS HEEL, w/ SHEATHING EDGE <br />NAILING REQUIRED. <br />FRAMING PER PLAN <br />WHEN 9-1/4" < "D" < 15-1/4": <br />SOLID 2x BLOCKING BETWEEN Z <br />TRUSSES ATTACHED TO TOP Q <br />PLATES w/ 8d NAILS @ 6" O.C. — r <br />ALONG LENGTH OF BRACED <br />WALL PANELS <br />a <br />SHEATHING SEE PLAN <br />FOR ATTACHMENT <br />PRE ENGINEERED <br />TRUSSES AT 24" O.C. <br />2x BLOCKING BETWEEN TRUSSES w/ <br />(3) 8d INTO SUPPORT 0 EA END TO <br />ADJACENT TRUSS OR TO TOP PLATES <br />SHEATHING PER PLAN <br />�'n TRUSS SCREW THRU LOCATION OF BRACING AT <br />�" L TOP PLATES TO TRUSS VAULTED TRUSS. <br />DETAIL AT RAISED HEEL <br />TRUSS SCREW O O <br />NOTE: PER PLAN CONTINUOUS BRACING TRUSS MANUF. <br />REFER TO ARCHITECTURAL DRAWINGS <br />AND/ OR TRUSS MANUFACTURER SHEATHING PER PLAN <br />DRAWINGS FOR SPECIFIC TRUSS PROFILE STUD PER PLAN <br />INFORMATION. (i.e. HEEL HEIGHTS, <br />SLOPE, OVERHANGS). FRAMING PER PLAN <br />1�TRUSS SCREW THRU TOP PLATES TO TRUSS <br />\_z <br />(I TRUSS ANCHOR ATTACHED TO TOP PLATES ON EXT. SIDE OF WALL <br />R02 ROOF TRUSS ON FRAME <br />Lu <br />2x4 BLOCKING AT 2'-0" <br />O.C. w/ (2) 12d TOE NAILS <br />EACH END TO TRUSS <br />BOND BEAM PER , SHEATHING PER PLAN <br />PLAN AND SCHEDULE META16 AT BLOCKING w/1/4" <br />8" CMU WALL. SEE PLAN MAX. GAP FROM TOP OF <br />FOR VERT. REINF. WALL TO BOTT. OF BLOCKING <br />R07 WALL�BRCINGA �TN ON -BEARING EXTERIOR �WALL <br />STRUCTURAL <br />SHEATHING PER PLAN <br />PRE ENGINEERED — <br />TRUSSES AT 24" O.C. <br />TRUSS ANCHOR <br />PER PLAN <br />BOND BEAM PER PLAN <br />AND SCHEDULE SHEATHING <br />PER PLAN <br />R08B WALLBRAC.ING AT BEARING WALL <br />(8) 10d NAILS EACH <br />ENGINEERED WOOD <br />ROOF TRUSS AT 24' <br />O.C. MAX. <br />CMU WALL <br />(4) 1/4" 0 c 2-1/4" MASONRY ----/ <br />SCREWS AT EACH STRAP. (1) SIMPSON HTSM16 <br />CONDTIONS OF USE: (OR APPROVED EQUAL) <br />1. QUANTITY OF MISSED STRAPS DOES NOT EXCEED FIVE (5) CONSECUTIVE LOCATIONS. AT EACH MISSED <br />2. UPLIFT VALUE FOR TRUSS LOCATION DOES NOT EXCEED 1,175 Ibs. UPLIFT. LOCATION. <br />3. NOT ACCEPTABLE ON MULTI —PLY TRUSS APPLICATIONS. <br />IF FIELD CONDITIONS EXCEED CONDITIONS OF USE, CONTACT ENGINEER OR ARCHITECT OF RECORD FOR APPROPRIATE SOLUTION. <br />nR1MISSED TRUSS STRAP REPAIR <br />(TYPICAL CMU WALL CONNECTION) <br />STRUCTURAL SHEATHING PER PLAN <br />2x4 LADDER FRAMING AT 24" O.C. REQ'D AT <br />OVERHANGS GREATER THAN 12". ATTACH TO TRUSS <br />TOP CHORD w/ (2)-16d NAILS AT 24" O.C. <br />CONT. 2x4 w/ (2) 12d NAILS <br />1. AT VERTICALS 3'-6" TO 6'-6" USE ONE 2x4 "L" BACK. <br />2. AT VERTICALS OVER 6'-6" TO 8'-4" USE (2) 20 "L" <br />BACKS (1 EA. SIDE) (OR FRAME PER CASE 3 BELOW). <br />3. AT VERTICALS OVER 8'-4" TO 13'-0" USE ONE 2x4 <br />"L" BACK AND AN ADDITIONAL DIAGONAL BRACE IS <br />REQUIRED AT THE PEAK AND AT EVERY OTHER VERTICAL <br />MEMBER IN THIS RANGE. ATTACH THE DIAGONAL AT MID <br />HEIGHT AND TO THE BLOCKING BELOW THE ROOF <br />SHEATHING w/ (5) 12d's AT EACH END. IN ADDITION TO <br />THE SECOND DIAGONAL, A STRONGBACK IS ALSO <br />REQUIRED AT THESE VERTICALS AND MUST BE ATTACHED <br />TO EACH "L" BACK WITH (2) 12d's AND ONE SIMPSON H5 <br />CONNECTOR. <br />2x4 OUTLOOKER <br />PER DRAWINGS <br />2x6 FASCIA <br />1x6 w/(3) 8d <br />EA. OUTLOOKER <br />2x4 OUTLOOKER <br />PER DRAWINGS <br />20 FASCIA <br />SHEATHING _ O D <br />PER PLAN. I\ <br />GABLE TRUSS <br />PER PLAN 20 BETWEEN EA. <br />OUTLOOKER w/(2) <br />10d TOENAILS _ <br />EDIMENT BLOCKING @ GABLE <br />VALLEY SET TRUSSES <br />AT 24" O.C. <br />ROOF SHEATHING <br />PER PLAN <br />MIN. 9" LONG 20 GA. <br />FLAT STRAP w/ (8) 1Od <br />SHEATHING PER —OR- <br />PLAN. <br />20 BLOCKING UNDER TRUSS <br />ENDS. NAIL TO TRUSS CHORDS <br />w/ (3) 10d EACH END. <br />DAQ VALLEY SET OVER FRAME <br />i Ivv TM& <br />SHEATHING <br />PER PLAN. <br />GABLE TRUSS <br />PER PLAN <br />VALLEY SET TRUSSES <br />AT 24" O.C. <br />ROOF SHEATHING <br />PER PLAN <br />PRE—ENGINEERED ROOF <br />TRUSSES @ MAX. 24' O.C. <br />SHEATHING PER ARCH lx4 FURRING AT <br />INSTALLED PER MANUF. MAX. 16' Q.C. w/ <br />(3)1Od AT EA TRUSS <br />sot EXTERIOR CEILING FURRING <br />SCALE: N.T.S. <br />SHEATHING PER —OR- <br />PLAN. <br />(1) SDWC15600 TRUSS SCREW <br />TO EVERY TRUSS BELOW <br />20 BLOCKING AT DIAGONALS ONLY, <br />2x4 BLOCKING AT DIAGONALS ONLY. ATTACH AT EACH <br />ATTACH AT EACH END w/ (2) 12d <br />END w/ (2) 12d TOENAILS. NAIL SHEATHING TO BLOCKING <br />TOENAILS. NAIL SHEATHING TO <br />AT 6" O.C. w/ MINIMUM 8d NAILS. BLOCK 4 BAYS BACK <br />STRUCTURAL SHEATHING PER PLAN <br />BLOCKING AT 6" O.C. w/ MINIMUM <br />FROM GABLE TRUSS. <br />2x4 LADDER FRAMING AT 24" O.C. REQ'D AT <br />8d NAILS. BLOCK4 BAYS BACK <br />FROM GABLE TRUSS. <br />WHEN SECOND BRACE IS REQUIRED, NAIL TO OPPOSITE <br />OVERHANGS GREATER THAN 12". ATTACH TO TRUSS <br />WHEN SECOND BRACE IS REQUIRED, <br />SIDE OF BLOCKING. <br />TOP CHORD w/ (2)-16d NAILS AT 24" O.C. <br />NAIL TO OPPOSITE SIDE OF BLOCKING. <br />CONT. 2x4 w/ (2) 12d NAILS <br />STRUCTURAL SHEATHING <br />2x6 DIAGONAL BRACING w/ (5) 10d COMMON NAILS TO <br />PRE—ENGINEERED WOOD <br />BLOCKING. UNLESS NOTED OTHERWISE ON PLANS, PROVIDE <br />TRUSSES AT 2'-0" O.C. MAX. 3 <br />SEE PLAN FOR ATTACHMENT OF ALL <br />3 ONE BRACE NEAR THE PEAK AND THE REMAINDER AT 48 <br />STRUCTURAL SHEATHING. <br />O.C. ®APPROX. 45—DEG ANGLE. <br />O <br />TRUSS ANCHORJ3 <br />SEE CONN. CHART <br />1. AT VERTICALS 3'-6" TO 6'-6" USE ONE <br />SPLICE DETAIL FOR DIAGONAL 4' LAP WITH "T" LAP <br />20 "L" BACK. <br />NAILED w 2 ROWS 10d GUN NAILS @ 8" O.C. <br />/ O <br />BOND BEAM PER PLA <br />2. AT VERTICALS OVER 6'-6" TO 8'-4" <br />(2) SIMPSON A23 w/ (8) 10d x 1-1/2" <br />USE (2) 2x4 "L" BACKS (1 EA. SIDE) (OR <br />(ONE ON EACH SIDE OF BRACE TO TOP PLATE). <br />2 SHTG <br />FRAME PER CASE 3 BELOW) <br />SIDE NAIL ALL "L' BACKS AND STRONGBACKS w/ 12d's SHEATHING PER PLAN <br />AT 6" O.C. NOTCH "L" BACKS AT TOP AND BOTTOM. <br />PROVIDE CONT. 2x8 P.T. PLATE w/ 1/2" 0 x 10" <br />ANCHOR BOLTS AT 4'-0' O.C. MAX. w/2"x2" PL. <br />STRUCTURAL SHEATHING <br />("`M) I <br />v v WASHERS AND 7" EMBEDMENT. <br />SEE PLAN FOR ATTACHMENT <br />NAIL BOTTOM CHORD OF GABLE <br />MASONRY WALL, BOND BEAM, LINTEL BEAM OR RAKED <br />TRUSS w/ 12d's AT 4" O.C. <br />BEAM PER PLAN. FOR RAKED BEAM AT VAULTED <br />-- , <br />CONDITION, SEE PLAN AND DETAIL. <br />/ <br />CONT. 2x4 <br />\ <br />2x4 NAILED FLAT TO TOP OF BRACE ("T" x6 NAILED <br />22 <br />CONTINUOUS / <br />BRACE) NAILED TO DIAG. w/ 10d GUN TOP <br />STRUCTURAL <br />NAILS @ 8" O.C. BUTT JOINT ALLOWED <br />SHEATHING SEE PLAN <br />(48" MIN MEMBER LENGTH), BRACED <br />FOR ATTACHMENT <br />REQUIRED TO BE CONTINUOUS OVER DIAG. <br />BRACE SPLICE SHOWN <br />FIELD NAILING <br />PER PLAN <br />2 4 BLOCKING AT 48" O C <br />\ 3xTRUSS BAYS <br />2x6 NAILED @ BOTTOM <br />FRAMING <br />WOOD PER PLAN GABLE END DIAGONAL BRACE TYPICAL SPLICE <br />R09GABLE END TRUSS BRACING DETAIL <br />GABLE END <br />FASCIA x <br />SEE ARCH. BLOCKING <br />DRAWINGS 3. AT VERTICALS OVER 8'-4" TO 13'-0" <br />8" CMU WALL OR USE ONE 2x4 "L" BACK AND AN <br />LINTEL, SEE PLAN SHEATHING PER ADDITIONAL DIAGONAL BRACE IS REQUIRED <br />FOR REINFORCEMENT PLAN AT THE PEAK AND AT EVERY OTHER <br />MASONRY VERTICAL MEMBER IN THIS RANGE. ATTACH <br />THE DIAGONAL AT MID HEIGHT AND TO THE <br />2x4 DIAGONAL BRACING w/ (5) 12d BLOCKING BELOW THE ROOF SHEATHING w/ <br />COMMON NAILS TO BLOCKING AND <br />\ TO THE "L" BACK. UNLESS NOTED (5) 12d's AT EACH END. IN ADDITION TO <br />OTHERWISE ON PLANS, PROVIDE THE SECOND DIAGONAL, A STRONGBACK IS <br />ONE BRACE AT THE PEAK AND THE ALSO REQUIRED AT THESE VERTICALS AND <br />REMAINDER AT 48" O.C. DIAGONALS MUST BE ATTACHED TO EACH "L" BACK <br />OVER 8'-0" MUST HAVE AN WITH (2) 12d's AND ONE SIMPSON H2.5A <br />OR ONE LISP RT5 CONNECTOR. <br />TRUSS ANCHOR <br />ADDITIONAL "T" BRACE ATTACHED <br />SEE CONN. CHART TO THE NARROW EDGE w/ /12d's SIDE NAIL ALL "L" BACKS AND <br />FRAMING PER PLAN AT 6" O.C.. "T" BRACE LENGTH TO STRONGBACKS w/ 12d's AT 6" O.C. NOTCH <br />BE THE DIAGONAL'S LENGTH MINUS "L" BACKS AT TOP AND BOTTOM. <br />12" FROM EACH END. <br />WOOD DUTCH HIP GABLE TRUSS BRACING DETAIL <br />R09B w� <br />"X" = 10% "X" = 10% "X" = 10% OF <br />HOUSE WIDTH ® HOUSE WIDTH HOUSE WIDTH <br />i4— �:q x x <br />O ® 3 , O ® 7 <br />0 �2 / <br />x x Co <br />RIDGE 7 X RIDGE RIDGE <br />� GABLE END � , — O GABLE END <br />BOSTON HIP X�� I GABLE X I HIP <br />ROOF SHEATHING <br />NAILS <br />ROOF FASTENING ZONES <br />SHINGLE: <br />7/16" SPAN RATED PLYWOOD OR OSB <br />8d RING SHANK <br />0.113" x 2-3/8" <br />1 <br />2 <br />3 <br />OFFSET DIMENSION "X" = 10% HOUSE WIDTH <br />"X" <br />"X" <br />TILE: 15/32" SPAN RATED PLYWOOD <br />OR OSB <br />PANEL EDGES SUPPORTS (1) <br />6" O.C. <br />6" O.C. <br />4" O.C. <br />PANEL FIELD 1 <br />6" O.C. <br />6" O.C. <br />6" O.C. <br />METAL: <br />15/32" SPAN RATED PLYWOOD w/24 GA. <br />19/32' SPAN RATED PLYWOOD w/26 GA. <br />NOILS: <br />1. LONG SIDE OF SHEATHING TO BE PERPENDICULAR TO TRUSSES OR RAFTERS -TYPICAL. <br />2. EDGE SPACING ALSO APPLIES OVER GABLE END WALLS OR TRUSSES. <br />3. FASTENING ZONES 2 AND 3 ARE EQUAL TO 10% OF TOTAL HOUSE WIDTH, DIMENSION "X" OFFSET FROM ROOF EDGE. <br />30' WIDE HOUSE = 3' ZONE, 40' WIDE HOUSE = 4' ZONE, 50' WIDE HOUSE = 5' ZONE, 60' WIDE HOUSE = 6' ZONE <br />R11 ROOF SHEATHING ATTACHMENT DIAGRAM <br />VALLEY SET TRUSSES <br />AT 24" O.C. <br />ROOF SHEATHING <br />PER PLAN <br />SHEATHING PER <br />PLAN. <br />20 PURLIN 0 EA VALLEY <br />TRUSS. NAIL TO COMMON <br />TRUSS w/(3) 16d GUN NAILS <br />BOTTOM CORD OF VALLEY <br />TRUSS NAILED TO PURUN <br />w/ 10d GUN NAIL @ 8" Q.C. <br />20 LADDER FRAMING AT 24' O.C. REQ'D AT <br />OVERHANGS GREATER THAN 12'. ATTACH TO TRUSS <br />TOP CHORD w/ (2)-16d NAILS AT 24" O.C. <br />CONT. 2x6 w/ (2) 12d NNLS � <br />STRUCTURAL SHEATHING PER PLAN <br />2x BLOCKING BETWEEN EA. <br />TRUSS MEMBER OR TRUSS WEB. <br />2x LEDGER w/2-10d @ EA. <br />CROSSING TRUSS MEMBER <br />FOR ROOF SHEATHING <br />NAILING <br />20 BLOCKING AT DIAGONALS ONLY. ATTACH AT <br />EACH END w/ (2) 12d TOENAILS. NAIL SHEATHING <br />TO BLOCKING AT 6" Q.C. w/ MINIMUM 8d NAILS, <br />BLOCK 8'-0' BACK FROM GABLE TRUSS. <br />2x4 DIAGONAL BRACING w/ (5) 12d COMMON <br />NAILS EA. E4ND ®32" MAX. SPACING <br />-'- IF LENGTH IS LESS THAN 4'-0' USE 2x4 "L" BACK, <br />IF LENGTH IS GREATER THEN 4'-O" USE (2) 2x4 "L" <br />BACKS. NAIL "L" BACKS w/12d ® 12'0,C.(NOTCHED <br />0 TOP w/2-12d TOENAILS <br />"L" BACK -EXTEND 6" PAST <br />LOWER ROOF SHEATHING <br />SHEATHING PER PLAN—J <br />PARTIAL GABLE END TRUSS DETAIL <br />ROTC PARTIAL GABLE <br />C.O.A.# ARCHITECTURE: <br />AA26002802 <br />G.O.A.# ENGINEERING: <br />29349 <br />THOMAS A. WEBER, PE <br />P.E, # 73242 FLORIDA <br />■ BENJAMIN NIESE, PE <br />P.E. # 86025 FLORIDA <br />11 /30/20 <br />DATE ttltillll { <br />Fi <br />\ * f <br />\` O. <br />—V <br />STAT <br />Rig <br />iflilt <br />tt�l <br />© <br />O <br />�Oy <br />co <br />� <br />+j <br />e-4 <br />v <br />°O <br />c� <br />o <br />0 <br />ul) <br />N <br />o <br />00 <br />-'TH <br />� <br />-:v <br />v <br />a�, <br />c� <br />c� <br />O <br />� <br />0 <br />bIJ <br />r" 1 <br />crS <br />N <br />0 <br />PRODUCT MANAGER <br />RELEASE <br />DATE: XX/XX/XXXX <br />PROJECT TYPE <br />Single Famfl <br />SPECIFICATION LEVEL <br />Pulte <br />FN NAME <br />i h ate <br />CHI NU ER <br />11.500 <br />SHEET <br />S4.1 <br />