My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6760 Ripple Pond Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6760 Ripple Pond Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 2:03:03 PM
Creation date
2/18/2025 4:37:09 PM
Metadata
Fields
Template:
Building Plans
Street #
6760
Location
Ripple Pond Lp
Contractor
Lennar Homes
Building Plans - Permit #
5008
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a <br />3 <br />yp <br />ZONE-1 <br />ATTIC SPACE <br />1072 SQ. FT. <br />G9� <br />w <br />6�.,2s�OPE <br />LU <br />`D <br />RIDGE <br />g <br />0 <br />v <br />I� 0 <br />JP <br />I <br />I <br />I <br />i <br />I <br />w <br />g <br />�`� <br />I <br />I <br />4 <br />I <br />I <br />41 <br />I <br />w <br />0 <br />-n. <br />Cn <br />I <br />I <br />I <br />Uj <br />G <br />6:12 SLOPE <br />L----- <br />— — — — <br />— <br />Attic Ventilation ATTIC VENTILATION CALCULATIONS <br />Attic Ventilation to be in compliance with the Florida Building Code 7th Edition ATTIC VENTILATION REQUIRED UPPER VENTILATION PROVIDED <br />(2020) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% 1/150 Rule Ridge <br />o No Upper Ventilators 300 Rule Off -Ridge <br />but no more than 50 /o of the required ventilation is provided in the upper portion of ( pp T(Must Provide <br />Vent Amt Amt. <br />e Upper Ventilators) <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet Req.) (Ft.) <br />(measured vertically) below the ridge or highest point of the space, with the Total <br />balance of the required ventilation provided by eave or cornice vents. Ventilation <br />-CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN** ATTIC Provided <br />(Values to be verified with Manufacturer Specifications) SPACE SQ. FT. Total SQ. SQ. FT. SQ. IN. of by Upper <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT SQ. IN. of of vented IN. of SIN. of of ventilation to Ventilators <br />ventilation <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. IN. of <br />soffit ventilation vented be provided Ventilation <br />tilation VentiSQ.lation <br />tilation (See Elev) <br />• STUCCO SOFFIT VENTS 126 SQ. IN. OF NET FREE AREA / SO. FT. required soffit by upper <br />needed required <br />*If not enough vented soffit is provided due to fire protection, the contractor shall use the needed I ventilators <br />following approved vents: <br />• LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. <br />"Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 =(Linear Ft. of Deck -Air Needed) <br />Main 0.0 2.0 <br />Floor 1070 1027 147 514 37 257 276.0 <br />(Zone 1) i 0.0 276.0 <br />Main 0.0 2.0 <br />Floor 992 952 136 476 34 238 276.0 <br />(Zone 2) 0.0 276.0 <br />**NOTE** <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FLORIDA BUILDING CODE 7TH EDITION (2020) RESIDENTIAL. <br />2 2 Z T6F <br />FP-1 FP-1 FP-1 2 <br />6FP-1 FP 1 FP-1 FP-1 FP-1 FP 1 P-1 FP-1 FP-1� <br />ZONE-2 <br />ATTIC SPACE <br />992 SQ. FT. FP-1 <br />ZONE-2 <br />ATTIC SPACE <br />996 SQ, FT. <br />ZONE-2 <br />ATTIC SPACE <br />997 SQ. FT. <br />ZONE-2 <br />ATTIC SPACE <br />994 SQ. FT. <br />K <br />FIRIE RETARDANT PLYWOOD FIRE RETARDANT PLYWOOD RETARDANT PLYWOOD FIRE RETARDANT PLYW <br />LOCATION, \TION. LOCATION. <br />4'-0" ROOF VENT 4A" ROOF VENT <br />0 <br />RIDGE <br />I w I <br />I � I <br />I I <br />I I <br />6+pE 6:12 SLOPE' <br />I I <br />I I <br />L--- ---J <br />4'-0" ROOF VENT 4'-0" ROOF VENT <br />0 0 <br />RIDGE <br />I I <br />ILU <br />� I <br />I I <br />I I <br />I 6� .12 SLOPE 6:12 SLOPE' I <br />I I <br />L t <br />I I <br />w "-4 <br />a <br />O <br />CD <br />6:12� SLOPE <br />FP 1 FP-1 I �Q <br />I I w <br />2 I o <br />FP-1 T <br />CAD <br />I I <br />L4 <br />4'4' ROOF VENT 4'-0" ROOF VENT edo, 00or 4'-0" ROOF VENT 4A" ROOF VENT <br />0 0 0 0 <br />RIDGE RIDGE <br />GOOF �t� G <br />I w I I w I <br />I I I 921 I <br />I I I I <br />I I I I <br />6:12� SLOPE 6:12 SLOPE 7 I I 6:12� SLOPE 6:12 SLOPE <br />I I I I <br />L t L <br />I I I I <br />0 0 <br />CO cG <br />6:12 SLOPE <br />7 <br />1 1 <br />'yo I FP-1 FP-1 I �Q <br />w <br />oCn 2 <br />FP-1 <br />I I <br />11 A�II <br />`i 4'-0" 4'-0" I, L L 4'-0" 4'-0" � <br />4'-0" 4'-0" 4'-0" 4'-0" <br />UNIT 1500 � UNIT 1397 UNIT 1397 UNIT 1397 UNIT 1397 <br />41 <br />ZONE-1 <br />I <br />ATTIC SPACE I <br />1070 SQ. FT. I <br />I <br />�, <br />Lu <br />z rl <br />6:12 SLOPE O <br />U_ —� <br />RIDGE <br />w <br />G o <br />I <br />I <br />I <br />I <br />I <br />I <br />w Z <br />v <br />w <br />0 <br />N <br />UjI <br />6:12� SLOPE I <br />— — — — — — — — — — J <br />1 1 <br />'-1 FP-1 <br />2 UNIT 1500 <br />FP-1 <br />ROOF PLAN <br />SCALE: 3/8"=1'-0" <br />Q <br />o <br />IN <br />A- <br />A- : <br />QC` <br />1, f J '^✓ <br />z-_ <br />C, <br />` <br />N <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural <br />engineering portions of the drawing pages bearing <br />Engineers <br />signature and seal. <br />W <br />11,_ <br />'q E <br />ci <br />0 0 <br />� cc °K <br />0 <br />rnr--ti� <br />N O� 252s � LL <br />W <br />J LL > a <br />W <br />m c � <n <br />O <br />l6 N <br />Wr02M <br />of <br />Z <br />J <br />CO <br />N <br />M Z QLL <br />Z <br />< <br />OU <br />W <br />❑ ❑ <br />V M � <br />0 <br />z <br />Q � a <br />J <br />o_ <br />r <br />z <br />�-1 <br />_o <br />4-1 <br />m <br />U <br />0 <br />t/1 <br />w oo <br />c « <br />Nss <br />r <br />U <br />u, m <br />� <br />L <br />z .. <br />pdp�� <br />U O N <br />0 <br />N O <br />f� <br />CD <br />¢ <br />W <br />z <br />co <br />M <br />w <br />o <br />LL_ <br />2 <br />E <br />> N <br />o® <br />¢=7O <br />E <br />Q <br />wKwo <br />❑ <br />O <br />¢ <br />oaZzZ <br />OC) <br />O <br />oa <br />oZa <br />w <br />co C <br />6p <br />OV <br />m� <br />o <br />zz< <br />Q <br />� J <br />� � <br /><w <br />E o <br />Cl) <br />y <br />¢ <br />oa <br />zz <br />a0 <br />a� <br />W <br />4 <br />w <br />o <br />w a <br />.0 <br />x <br />p <br />d <br />�I¢ <br />2 <br />UU <br />0 <br />`N <br />>L <br />CID <br />ui <br />rn <br />o <br />0 <br />L J <br />AAWWL�' <br />- <br />0 <br />O <br />M <br />CID <br />d <br />�✓ <br />CT U <br />T <br />60 <br />T— <br />U) m <br />o <br />Q <br />O <br />N <br />N <br />04 <br />Q O <br />04 <br />L <br />Cf� <br />N <br />T <br />Lo <br />J <br />T'7 <br />m <br />O <br />z <br />E <br />E <br />-D <br />m <br />C <br />d <br />U <br />Q O <br />JOB NO: 22-03326-03321 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />10.1 <br />