1 I I I I I I - - L A. H A _ I I 1 I q I <br />GENERAL CONCRETE LINTEL SCHEDULE <br />• +• SYMMETRICAL O <br />• • • • • APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY <br />81781B/1T 8F8-06/1T <br />TYPE DESIGNATION #5REBAR ATTOP E O N <br />.0 <br />' •' MIN. (1) REO'D <br />-c <br />• • • ' • F =FILLED WITH ° vz" ce) GROUT �'- <br />/ U = UNFILLED d CGJ <br />8RF14-1 B/1T 8RF14-0B/1T R = RECESSED LEAR 4' <br />A " � � • � © O CITY. OF #5 ° ° = c <br />': • . REBAR @ BOTTOM N - <br />,Z ZOF LINTEL CAVITY J d M.u. ; Zy <br />.;•r . . . j 2 °° G! <br />az O ' y <br />8F 16-i'B/1 T ° ° MS25 <br />O O 1 <br />z G GROUT <br />,, r r, � ,, •' ,, to a • _. <br />•••, • • I NOMINAL. QUANTITY OF <br />t ° 5 REBAR AT ` <br />• • • • • • • • , • WIDTH #5 REBAR AT ° BOTTOM OF _ U - <br />TOP o LINTEL CAVITY J, O 0 <br />8F20-OB/1T 8F20-1B/1T8F16-OB/1T 8F16-1B/1T NOMINAL- OTTOM <br />c6 O 0 <br />HEIGHT REINFORCING 0- 4- <br />HEIGHT <br />© © O © 7-5/8"ACTUAL PROVIDED IN <br />8" NOMINAL WIDTH LINTEL H <br />i • .•.• : i ; � r : �, (VARIES) I <br />% • ' % ' MATERIALS <br />1. fc precast lintels = 3500 psi. <br />• • ' ' ' ' •! ' • ` ' 2. fc prestressed lintels = 6000 psi. <br />$RF6-OB/1 TLI 3. grouted per ASTM C476 fg = 3000 psi w/ <br />. r L , ; . 4. maximum 3/8" aggregate and 8" to 11" slump. _ <br />5. Concrete masonry units (CMU) per ASTM C90 w/ O I F <br />© ' 'I minimum net area compressive strength = 1900 psi. <br />• • ' ;; • , 6. Rebar per ASTM A615 Grade 60. <br />Prestressing strand per ASTM A416 grade C14 <br />;�• 7. 270 low relaxation. <br />'. • '. • 7/32 wire per ASTM A510. \ ` <br />' • • • % ;' 8. Mortar per ASTM C270 type M or S. cJ <br />8F20-1B-2T • ` ,�' '= <br />*' �-% • • • • • • GENERAL INSTALLATION NOTES <br />1. Provide full mortar head and bed joints. <br />' © 8RF22-1B/1T 8F24-OB/1T 8F24-1B/1T <br />• = • % • • 2, Shore filled lintels as required. ` 1 �' • ��, <br />° ,, • •�, ••• �,•� © O O 3. Installation of lintel must comply with the architectural and/or structural drawings. <br />4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate H <br />vertical cell reinforcing and grouting. O 0 <br />•�. <br />• ; `' �' ::0 , 5. All lintels meet or exceed U360 vertical deflection, except lintels 17'-4" and a' <br />• • ' • ; longer with a nominal height of 8" meet or exceed U180. ~ <br />.' ; • : • '• . . , 6, Bottom field added rebar to be located at the bottom of the lintel cavity. <br />7, 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. _ 3 <br />' 8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete <br />• masonry units. <br />FP-1 <br />�', ; • , . , • • , • • ' , • • '. ' • ' , • , . ' , . , 9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 coT 3 <br />F- <br />' ; , ; ; • ; 10. Product Approvals: Miami Dade County, Florida Nos.20-0630.16 and 20-0630.15. <br />11. The exterior surface of lintels installed in exterior concrete masonry walls shall have <br />r <br />• • ' a coating of stucco applied in accordance with ASTM C-926 or other approved FP-1 <br />coating. LL _ <br />O <br />•• ; �'• ; , �'• ; ; �'� ; • �', ; : , ; :`� • ; ILI 12. All lintel dimensions shown are "overall" lintel lengths. 00 CO <br />.• <br />;'• ; ;'• ; ',', ; ;', : , . 13. Lintels loaded simultaneously with veritcal (gravity and uplift) and horizontal (lateral) 3 <br />• • • • loads shoud be checked for combine loading with the following equation: r To the best of the Engineer's knowledge, information and belief, <br />• , L . : .,, ' , • Applied vertical load Applied horizontal load OQj FP-1 the structural plans and specifications contained within these <br />` •' • Safe vertical load +Safe horizontal load < 0 �\ drawings comply with the 2020 Florida Building Code - <br />:.� J101- <br />L <br />, �� Residential 7th Edition. Engineers signature and seal is only for <br />, r• the sWctural engineering portions of the drawing pages bea ng <br />I r ` • Engineers signature and seal. <br />a,. W v E <br />81F44113/1T8F4006/1T 8RF40OB/1T 8F321B/1T 8F320B/1T 8RF301B/1T 81F28OB/1T 81F281B/1T � a N <br />�d ?3 N <br />O - - - V �.' C N OrD <br />J <br />0 N O # LL <br />JLLLL I w a <br />ALTERNATE POWERS LINTEL PLAN NOTES: <br />13 <br />_ <br />STEEL LINTEL Z a <br />1. THIS PLAN IS TO BE USED FOR STRUCTURAL W ~ ro � 1 <br />00 Oo W om�� o <br />INFORMATION ONLY. N co Q M o <br />r� ~ W o m J <br />LL':t::. Z oo co Z Q <br />#S .(1)RE AT TOP 2. UNLESS NOTED OTHERWISE ALL LINTEL DEPTHS ARE <br />MIN.(1)REO'D 1-1/2"CLEAR <br />Z U v vvi <br />TO BE ASSUMED TO BE 16" MINIMUM DEPTH. H <br />3. THE NUMBER OF COURSES OF MASONRY REQUIRED O <br />BETWEEN THE LINTEL & THE BOND BEAM SHOULD BE z <br />w z �� <br />dLu C.M.U. COORDINATED WITH THE ELEVATION DRAWINGS <br />1 0 4. THE CONTRACTOR IS RESPONSIBLE FOR _ <br />_ a) J - <br />.U)om wwo <br />_° W J COORDINATING THE PROPER LINTEL HEIGHT. _ I (111110z <br />�r3� Co <br />O N <br />oLO°? 5. LINTELS AT GARAGE DOOR OPENING ARE MINIMUM `�' v `� 0 <br />c1) �4--, <br />a: W <br /><0<1 DEPTH REQUIRED FOR THE DESIGN LOADS. THE `'' <br />w _ri 5 REBAR AT BOTTOM <br />U O <br />�QOQ AS INDICATED DEPTH MAY BE INCREASED IF REQUIRED FOR _ <br />•o <br />NLL 00 C g <br />4- U) <br />PROPER LINTEL HEIGHT,G.C. COORDINATE. <br />16 GAUGE POWERS N = III <br />STEEL BOXED LINTEL <br />C� <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) <br />ONLY IF NOTED ON LINTEL PLAN POWER STEEL LINTEL IS AN ADEQUATE -A (no -o <br />1. Refer to manufacturer's specifications for installation. o o 4 I, <br />2. Contractor to provide proper protection of lintel to prevent rusting. SUBSTITUTION @ ALL LOCATIONS UNLESS O O O O <br />Refer to manufacturer's specifications. <br />3. If lintel is scratched or damaged refer to Powers Steel for repair. NOTED OTHERWISE AT OPENING LOCATION cfl = <br />4. Lintel depth to match precast depth. One #5 Bar required at top M Z <br />see lintel plan/details for bottom steel required. 0 U_ z ¢ Z <br />� � Ll g ry <br />5. A bonding agent must be applied to the Steel Box lintels prior to 0 _ <br />_ 0 a, R o <'M <br />applying the cementitiuos coating. See contractor specifications O ~ o < LL <br />, E: U <o <br />Cfl CO C o 0 <br />Z op <br />O 8 az <br />2" DIA. PIN #3 SHEAR REINFORCING <br />oN m <o wW <br />=' L < o 0 <br />@ 16" O.C. x °" <br />< 0 <br />K.O. BLOCK COURSE H H H Z `Cn <br />Cn Z <br />`<W <br />O <br />00 w/(2)-#5 TOP, MIN (SOLID <br />O O LLOg -Z <br />o <br />GROUT G MIN. MIN. MIN. I W c; a. <br />�- CM ) ,� <br />r Mill <br />o w ¢ Flo <br />T (2) #5 REBAR @ BOTTOM <br />OF LINTEL CAVITY � =l¢ 03 <br />UNIT 1500 UNIT 1397 UNIT 1397 SYMMETRICAL N N <br />PRECAST LINTEL UNIT ' Li') <br />co <br />BY MANUF. <br />o <br />0 <br />ILn � <br />T � T O � O <br />AS25 LINTEL W/ SHEAR REINF. M N <br />Cr r <br />N.T.s. REV 05.02.22 CAB LINTEL PLAN � '4_0 m C) <br />Q4-4 <br />r <br />SCALE: 3/16"=1'-O" CN <br />0 <br />CD <br />Q 04 O <br />04 0)b <br />C� LO f <br />i» N o <br />E E r y Z <br />z E m <br />m E 8 -o � c <br />a 0 � ¢ 0 <br />JOB NO: 22-03326-03321 <br />SCALE : AS NOTED <br />SHEET NO. <br />L 1 <br />