My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Gall Blvd (107)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Gall Blvd (107)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 11:13:51 AM
Creation date
2/18/2025 4:38:50 PM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Gall Blvd
Contractor
Berglund Construction Company
Building Plans - Permit #
2203
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
R <br />E <br />D <br />C <br />B <br />A <br />1 <br />1 <br />iTi ii <br />EG-1 01 <br />( 4 $ <br />L <br />570 (E) <br />1 <br />�m x».. .... <br />LS-1 <br />TYPICAL S- TYPICALJL <br />;r <br />" <br />165 OF4 170 OF4 <br />SD-1 <br />Q 1 la) I <br />(E) 10"xl <br />385 <br />—I <br />e <br />;l. III rc,I <br />S: <br />co <br />X <br />N <br />a <br />q.. <br />- <br />CV <br />X <br />W <br />; <br />;mm <br />k <br />w <br />�(E) 8" ff <br />f. <br />75 <br />E 10 x10" <br />O <br />1 a E 12"x12" <br />„ ( ) <br />_ <br />........ <br />; <br />E(G'1 01 E NG " L IN <br />`� <br />X <br />C,R_��" <br />.......... <br />570 WALL" POSITIV PRESS <br />MONITOR TO REMAIN. <br />w <br />`` <br />TO <br />RH2O5 <br />DPI <br />EXISTING REHEAT COIL AND <br />(E) 20"x12" <br />HUMIDIFIER TO REMAIN. <br />12"xl2" <br />STS L <br />(E) <br />20"x20" <br />.16"x14" <br />RH <br />205 <br />D""` <br />N <br />N <br />2 MECHANICAL NEW PLAN <br />1/4" = 1'-0" <br />VA <br />3 <br />4 <br />........ ........ <br />E <br />EG)1 01 EXISTING EQUIPMENT \ <br />570 BOOM TO REMAIN. <br />�..... (E) (R) <br />LS 1 (TYP. 5) LS 1 (TYP. 3) .OL ' <br />165 170 <br />00 <br />w <br />�I <br />10 <br />E x1 <br />EXISTING ANESTHESIA <br />- <br />BOOM TO REMAIN. <br />(E) 8"x8" <br />- <br />3' <br />I I C, 11 .. _. <br />(E)10"x10" (E) 12"xl2" <br />(E) 20"x12" \\ 05 <br />EXISTING MED GAS ZONE <br />VALVES FOR OR 5 TO REMAIN. <br />MECHANICAL DEMO PLAN <br />1/4" =1'-0" <br />4 <br />EG-1 <br />5 <br />5 <br />SD-1 <br />-160 <br />Ft <br />GENERAL NOTES: <br />1 THE EXISTING FACILITY'S AIR HANDLERS AND INTERLOCKED EXHAUST FANS SHUTDOWN UPON <br />SIGNAL FROM THE FIRE ALARM SYSTEM AND ASSOCIATED FIRE/SMOKE DAMPER CLOSE. <br />2 EXISTING FIRE PROTECTIONS SYSTEM TO REMAIN. NO WALLS ARE BEING MODIFIED, CURRENT <br />SPRINKLER HEAD LOCATIONS ARE CODE COMPLIANT. <br />KEY NOTES <br />050 PROPOSED LOCATION OF ROOM PRESSURE MONITOR PER FACILITY ICRA. <br />051 PROPOSED LOCATION OF TEMPORARY NEGATIVE AIR MACHINE WITH HEPA FILTRATION TO <br />MAINTAIN NEGATIVE PRESSURE AT CONSTRUCTION ZONE. FAN CRITERIA: TEMPORARY <br />NEGATIVE AIR EXHAUST MACHINE WITH MERV 17 FILTERS AND CARBON FILTERS IF REQUIRED <br />BY ICRA. UNIT SHALL BE EQUAL TO HEPA-AIRE PAS1200HC (VARIABLE SPEED -150 CFM TO <br />1000 CFM). PROVIDE ADDITIONAL FANS AS REQUIRED TO MAINTAIN ADEQUATE NEGATIVE <br />PRESSURE. REFER TO CONSTRUCTION CONFINEMENT SYSTEM DETAIL FOR AIR SCRUBBER <br />DISCHARGE. COORDINATE WITH FACILITY ICRA. <br />052 PROPOSED LOCATIONS OF PHASED TEMPORARY CONSTRUCTION BARRIERS TO ISOLATE <br />RENOVATION WORK FROM CONSTRUCTION ZONES. FIRE RATED AS PER ARCHITECTURAL <br />DEMOLITION PLAN. <br />701 EXISTING LOW WALL RETURN GRILLE TO REMAIN, BALANCE TO AIRFLOW SHOWN. <br />2 <br />6 <br />L <br />chapuis design group <br />arch itectu re. pa <br />510 Vonderburg Drive I Suite 216 Brandon, <br />Florida 33511 1813.667.2340 <br />CGDPA - FL # AA-26003049 <br />exp U.S. Services Inc. <br />t: +1.407.660.0088 f: +1.407.660.1655 <br />2601 Westhall Lane <br />Maitland, FL 32751 <br />USA <br />we <br />www.exp.com •� �j <br />Project #: 21005054 <br />Cert of Auth: 29701 exp. <br />D <br />PROJECT FOR <br />ADVENT HEALTH - <br />ZEPHRYHILLS <br />OPERATING ROOM <br />5 - CYSTOSCOPY <br />7050 GALL BLVD. <br />ZEPHYRHILLS, FL 33541 <br />60111 <br />Advent Health <br />1 05/05/2021 'AHCA COMMENTS 1 <br />MARK DATE DESCRIPTION <br />PROJECT NUMBER 042-21-177.01 <br />ORIGINAL ISSUE 03111/21 <br />PROJECT MANAGER TEC <br />PROJECT DESIGNER n/a <br />PROJECT ARCHITECT THOMAS E. CHAPUIS AR 97109 <br />B LANDSCAPE ARCHITECT n/a <br />CIVIL ENGINEER n/a <br />STRUCTURAL ENGINEER n/a <br />MECHANICAL ENGINEER TIMOTHY P. PENNOCK PE 54516 <br />ELECTRICAL ENGINEER CHARLES T. ALEXANDER PE 76422 <br />INTERIOR DESIGNER n/a <br />EQUIPMENT PLANNER n/a <br />DRAWN BY Author <br />iPE'�1J�// <br />No. U516 <br />STATE OIF <br />,+��tA t1�ti®`�'��� <br />INI <br />MECHANICAL PLANS <br />DEMO AND NEW <br />A <br />PROJECT <br />NORTH SCALE 1/4" = 1'-0" <br />m 101 <br />Project Status <br />
The URL can be used to link to this page
Your browser does not support the video tag.