My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Gall Blvd (107)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Gall Blvd (107)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 11:13:51 AM
Creation date
2/18/2025 4:38:50 PM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Gall Blvd
Contractor
Berglund Construction Company
Building Plans - Permit #
2203
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br />E <br />C <br />B <br />A <br />.g L" <br />v <br />2 o <br />LO <br />� N <br />2 3 <br />STATION OUTLETS FOR <br />MEDICAL GAS IN OPERATING <br />ROOM #5 CYSTOSCOPY <br />CODE REQUIRED* <br />EXISTING <br />ANESTHESIA <br />BOOM <br />EQUIPMENT BOOM <br />OXYGEN <br />2 <br />2 <br />0 <br />VACUUM <br />5 <br />3 <br />2 <br />MEDICAL AIR <br />1 <br />1 <br />0 <br />INSTRUMENT AIR <br />1 <br />1 <br />0 <br />WAGD <br />1 <br />1 <br />0 <br />*BASED ON 2018 FGI TABLE 2.1-3 <br />STRAP HANGERS <br />NOTE 3 <br />THREADED I <br />HANGER ROD — <br />GALVANIZED HANGER STRAP <br />UNISTRUT OR <br />ANGLE IRON—� <br />—CONTINUOUS HANGER <br />STRAP AROUND DUCT <br />NOTES: <br />1. ON DUCTS OVER 48" WIDE, BOTTOM <br />SHALL BE BRACED BY ANGLE. FOR <br />CROSS SECTION AREA MORE THAN 8 <br />SQ. FT, DUCT SHALL BE BRACED BY <br />ANGLES ON ALL FOUR SIDES. <br />2. CUTTING AND PATCHING SHALL BE <br />LIMITED TO A MINIMUM AS REQUIRED <br />FOR PROPER INSTALLATION. <br />3. SUPPORTS SHALL BE SPACED AND <br />SIZED AS PER SMACNA. <br />4. REFER TO SMACNA FOR SPECIFIC <br />RECOMMENDED HANGER TYPES NOTED <br />ABOVE. <br />5. IN LIEU OF STRAP AND ROD HANGERS, <br />STEEL CABLE DUCT HANGING SYSTEM <br />MAY BE USED. BAND <br />A DUCT HANGER SUPPORT <br />NTS <br />NOTES: <br />1. VOLUME DAMPERS AND LOW LOSS FITTINGS MAY <br />OR MAY NOT BE INDICATED ON THE PLANS. THEY <br />ARE REQUIRED EVEN IF NOT SHOWN. <br />CONICAL BRANCH DUCT TAP OFF <br />OF RECTANGULAR OR ROUND MAIN DUCT - <br />SHOE TAP FITTING. SADDLE <br />TYPE IF CONNECTING TO <br />ROUND OR FLAT OVAL MAIN. <br />RECTANGULAR TO ROUND BRANCH <br />CONNECTIONS WHEN REQUIRED BY <br />MAIN DUCT SHAPE <br />BRANCH DUCT <br />MAIN DUCT <br />4 5 6 <br />�AHU-26 VENTILATION TABULATION - FGI <br />(2018) / ASHRAE 170 (2017) <br />GUIDE <br />LINES <br />CLG <br />FLR <br />ASHRAE 170 <br />ROOM <br />ROOM <br />ROOM <br />HGT. <br />AREA <br />VOLUME <br />EA <br />FILTER <br />PRES. <br />CODE CFM <br />ACTUAL CFM <br />BALANCE <br />O.A. <br />TA <br />NAME <br />Type <br />(FT.) <br />SF <br />(CU. FT.) <br />% <br />A.C. <br />A.C. <br />LTYPE <br />-F-(Transfer) <br />T.A. <br />O.A. <br />E.A. <br />S.A. <br />R.A. <br />E.A. <br />Exfil <br />10 <br />(pos = out) <br />CYSTOSCOPY <br />Operating(OR)/Surgical Cystoscopic rooms <br />10.0 <br />390 <br />3,900 <br />0% <br />95% <br />POS <br />4.0 <br />20.0 <br />1,300 <br />260 <br />0 <br />1,340 <br />1,140 <br />0 <br />0 <br />200 <br />3,050 SHEET: AVERAGE % OA = 20.0% <br />SHEET: SPACE BALANCE = 0 <br />SHEET: 15% OA CFM ** = 457 <br />SHEET: SA CFM- RA CFM = 610 <br />RELIEF AIR AT AHU= 0 <br />TOTAL OA (Max for DCV) = 610 <br />TOTAL OA% = 20.0% <br />MINIMUM OA FOR DCV = 610 <br />AHU-26 AIR BALANCE SCHEDULE <br />SYSTEM <br />EXISTING CFM <br />DURING CCFM RUCTION <br />FINAL CFM <br />AHU-21 SUPPLY <br />3,040 <br />1,705 <br />3,045 <br />AHU-21 RETURN <br />2,430 <br />1,095 <br />2,435 <br />AHU-21 OUTSIDE AIR <br />610 <br />610 <br />610 <br />EF-30 EXHAUST <br />610 <br />610 <br />610 <br />SYSTEM BALANCE <br />0 <br />0 <br />0 <br />NOTES: <br />1 EXISTING AIRFLOWS LISTED ABOVE ARE BASE ON AS -BUILT DOCUMENTS, T&B CONTRACTOR TO <br />VERIFY AIRFLOWS PRIOR TO DEMOLITION OR NEW CONSTRUCTION. <br />2 PROVIDE NEW MERV-8, MERV-14 AND HEPA FILTERS FOR AHU-26. <br />3 TOTAL AIRFLOW OF EF-30 IS 1670CFM, 610 CFM IS REMOVED FROM AHU-26. <br />4 CONFIRM AHU-26 SHUTS DOWN ON LOCAL FIRE ALARM. <br />STRAP OR <br />ANGLE <br />OVER 60" <br />TRAPEZE HANGERS <br />I <br />BAND <br />STRAP; <br />36" DIA. MAX. <br />TAPERED CONNECTION 45* <br />ANGLE (IF BRANCH DUCT IS <br />RECTANGULAR) L=114 W; 4" <br />MIN <br />PROVIDE VOLUME <br />DAMPER AT ALL <br />BRANCH TAKE -OFFS. <br />PROVIDE STANDOFF <br />HANDLE FOR <br />EXTERNALLY INSULATED <br />DUCT. PROVIDE <br />LOCKING HAND <br />QUADRANT. PROVIDE <br />12" OF ORANGE <br />SURVEYOR'S TAPE FOR <br />EASE OF MANUAL <br />VOLUME DAMPER <br />IDENTIFICATION (TYP). <br />�W <br />\RECTANGULAR BRANCH DUCT TAP <br />L OFF OF RECTANGULAR MAIN DUCT <br />EXTERNAL INSULATION <br />SUPPLY AIR <br />-� RETURN/EXHAUST AIR <br />TEMPORARY PARTITION <br />OR EXISTING WALL <br />24X24 LAY -IN <br />VESTIBULE PER <br />DIFFUSER <br />FACILITY ICRA <br />CONSTRUCTION ZONE <br />OCCUPIED AREA <br />- <br />+ <br />TO -0.03" <br />7fTRANSFERAIRPORTABLE <br />AIR SCRUBBER <br />BACK TO <br />CONSTRUCTION ZONE <br />WITH HEPA FILTRATION "0 <br />DIFFERENTIAL PRESSURE INDICATOR <br />"BALL IN THE WALL" PER FACILITY ICRA TEMPORARY PARTITION <br />OR EXISTING WALL <br />2 CONSTRUCTION CONFINEMENT SYSTEM <br />12" - V-0" <br />BRANCH CONNECTION, REFER TO DETAIL. <br />PROVIDE VOLUME DAMPER, LOCKING HAND <br />SUPPLY DUCT QUADRANT, & STANDOFF HANDLE FOR <br />INSULATE AS PER EXTERNALLY INSULATED DUCTS. <br />SPECIFICATIONS. <br />HANGER (TYP.) <br />TRANSITION (IF REQ'D.) <br />r/D > 1.5 <br />BRANCH DAMPER FOR COORDINATE DIFFUSER MOUNTING <br />AIR BALANCE ADJUSTMENTS.--JTYPE WITH CEILING TYPE. <br />� CEILING DIFFUSER -RIGID DUCT <br />NTS NTS <br />1 2 3 4 5 <br />COMPLY WITH FACILITY'S ICRA WHICH INCLUDES THE FOLLOWING REQUIREMENTS: <br />1. DPS - MAINTAIN CONSTRUCTION ZONE AT NEGATIVE PRESSURE TO OCCUPIED <br />AREA OF 0.03" WG PER FACILITY ICRA. PROVIDE DIFFERENTIAL PRESSURE <br />MONITOR/RECORDER PER FACILITY ICRA TO RECORD AND ALARM PRESSURE. <br />MAINTAIN SUFFICIENT DIFFERENTIAL PRESSURE TO MAINTAIN ALL <br />CONSTRUCTION DUST FUMES. <br />2. CONSTRUCTION ZONE SHALL BE SEALED TIGHT TO OCCUPIED AREAS AND <br />CEILING CAVITY TO PROVIDE THE CONSTRUCTION ZONE CONTAINMENT SYSTEM <br />AND MINIMIZE EXHAUST AND MAKE UP AIR. TYPICAL EXHAUST AIR REQUIRED IS 4 <br />AIR CHANGES PER HOUR. <br />3. ADJUST MAKE UP AIR VOLUME AS REQUIRED TO MAINTAIN PRESSURE <br />REQUIREMENTS. <br />4. INSURE CONSTRUCTION ZONE IS ISOLATED FROM OCCUPIED AREA WITH <br />TEMPORARY PARTITIONS, BELOW AND ABOVE THE CEILING, <br />5. EXISTING DOORS/PARTITIONS CAN BE UTILIZED AS PART OF THE <br />CONSTRUCTION ZONE CONTAINMENT SYSTEM. <br />NOTES: <br />EXTERNALLY INSULATED ROUND <br />1. <br />THIS DETAIL ALSO APPLIES TO RETURN & EXHAUST. <br />SHEET METAL DUCT TO DIFFUSER <br />2. <br />VISIBLE INSIDES OF DUCT SHALL BE PAINTED FLAT BLACK. <br />SAME SIZE AS DIFFUSER NECK <br />3. <br />FOR BRANCHES OFF ROUND OF FLAT DUCT, USE SADDLE TYPE <br />EXCEPT WHERE <br />CONNECTION. <br />INDICATED. <br />4. <br />IF r/D > 1.5 CAN NOT FIT, THEN r/D > 1.0 IS FIRST ALTERNATE <br />AND ALTERNATE 2 IS MITERED WITH TURNING VANES. <br />5. <br />PROVIDE RIGID DUCT FOR CRITICAL CARE AREAS - OPERATING <br />ROOMS, DELIVERY ROOMS, & CRITICAL CARE UNITS. <br />PROVIDE METAL DUCT <br />6. <br />PROVIDE CEILING GRID CLIPS AT TWO DIAGONALLY OPPOSITE <br />TRANSITION FOR SQUARE <br />CORNERS OF GRILLE. <br />NECK GRILLE AS REQUIRED <br />CEILING DIFFUSER <br />INSULATE BACK PER <br />SPECIFICATIONS. <br />—CEILING - SEE <br />ARCHITECTURAL PLAN FOR <br />THE TYPE. <br />GRILLE DAMPER NOT TO BE USED <br />FOR PRIMARY BALANCING. <br />6 <br />E <br />chapuis design group <br />architecture.pa <br />510 Vonderburg Drive I Suite 216 Brandon, <br />Florida 33511 1 813.667.2340 <br />CGDPA - FL # AA-26003049 <br />exp U.S. Services Inc. <br />t: +1.407.660.0088 f: <br />+1.407.660.1655 <br />2601 Westhall Lane <br />Maitland, FL 32751 <br />USA <br />00 <br />Q <br />~.exp.com <br />0 P <br />Project #: 21005054 <br />ex <br />Cart of Auth: 29701 <br />• <br />D <br />PROJECT FOR <br />ADVENT HEALTH - <br />ZEPHRYHILLS <br />OPERATING ROOM <br />5-CYSTOSCOPY <br />7050 GALL BLVD. <br />ZEPHYRHILLS, FL 33541 <br />1 05/05/2021 1 AHCA COMMENTS 1 <br />MARK I DATE DESCRIPTION <br />PROJECT NUMBER 042-21-177.01 <br />ORIGINAL ISSUE 03/11/21 <br />PROJECT MANAGER TEC <br />PROJECT DESIGNER n/a <br />PROJECT ARCHITECT THOMAS E. CHAPUIS AR 97109 <br />B LANDSCAPE ARCHITECT n/a <br />CIVIL ENGINEER n/a <br />STRUCTURAL ENGINEER n/a <br />MECHANICAL ENGINEER TIMOTHY P. PENNOCK PE 54516 <br />ELECTRICAL ENGINEER CHARLES T. ALEXANDER PE 76422 <br />INTERIOR DESIGNER n/a <br />EQUIPMENT PLANNER n/a <br />DRAWN BY Author <br />Cl <br />No. 5018 �� r <br />STATE OF : 9 <br />''i�� �•= ORN1P '"�� �''�• <br />ltt8Iitt <br />iO <br />MECHANICAL <br />SCHEDULES AND <br />A DETAILS <br />SCALE 12" = V0" <br />I <br />M600 <br />Project Status <br />
The URL can be used to link to this page
Your browser does not support the video tag.