-1-1-I <br />l <br />\__ I <br />7 <br />E <br />m <br />HVAC GENERAL NOTES <br />1. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL MATERIAL AND EQUIPMENT IN <br />STRICT ACCORDANCE WITH APPLICABLE CODES AND STANDARDS, AND PER <br />MANUFACTURER'S DIRECTIONS. <br />2. THE CONTRACTOR SHALL SECURE AND PAY FOR ALL NECESSARY PERMITS, LICENSE, <br />INSPECTIONS, APPROVALS, AND FEES. <br />3. THE CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL OTHER TRADES BEFORE <br />INSTALLATION OF ANY MATERIALS OR EQUIPMENT. <br />4. THESE DRAWINGS ARE DIAGRAMMATIC AND SHOW GENERAL LOCATION AND <br />ARRANGEMENT OF ALL MATERIALS AND EQUIPMENT. THE DRAWINGS SHALL BE <br />FOLLOWED AS CLOSELY AS BUILDING CONSTRUCTION AND ALL OTHER WORK WILL <br />PERMIT. <br />5. DO NOT SCALE DRAWINGS FOR MEASUREMENTS. <br />6. ALL PENETRATIONS THROUGH EXTERIOR WALLS 4 ROOF SHALL BE FLASHED t <br />COUNTERFLASNED IN A WATERPROOF MANNER. (COLOR TO MATCH EXTERIOR). <br />7. SEAL ALL PENETRATIONS OF RATED WALLS WITH FIRE DAMPER, SEALANT MATERIAL <br />APPROVED BY LOCAL CODE. <br />8. ALL SUSPENDED MATERIALS AND EQUIPMENT SHALL BE INDIVIDUALLY SUPPORTED <br />FROM THE BUILDING STRUCTURE. DO NOT SUSPEND ITEMS FROM THE CEILING OR <br />ITS SUPPORT SYSTEM. <br />9. INSTALL LCONTROL DEVICES INCLUDING THERM05TA S AN SWITCHES 4'-0' <br />ABOVE FINISHED FLOOR. PROVIDE THE REQUIRED DEVICES) FOR ALL SYSTEMS <br />WHETHER LOCATED ON THE PLANS OR NOT. <br />10. LOCATE CEILING DIFFUSERS IN ACCORDANCE WITH ARCHITECTURAL REFLECTED <br />CEILING PLANS (IF PROVIDED). <br />11. PROVIDE MANUFACTURER'S RECOMMENDED CLEARANCES AROUND MECHANICAL UNITS <br />FOR MAINTENANCE AND FILTER REMOVAL. <br />12. ALL PIPING AND DUCTWORK LOCATIONS SHALL BE COORDINATED W/ WORK UNDER <br />OTHER DIVISIONS OF THE SPECIFICATIONS, TO AVOID INTERFERENCE. <br />13. PROVIDE I YEAR WARRANTY ON ALL EQUIPMENT AND 5 YEAR WARRANTY ON ALL <br />COMPRESSORS. <br />14. ALL INTAKE OPENINGS SHALL BE LOCATED A MINIMUM OF 10'-0' FROM ALL EXHAUST <br />LOCATIONS. <br />15. CONDENSATE DRAIN PIPING SHALL BE SCHEDULE 40 PVC PIPE AND FITTINGS. <br />DRAINS FROM AIR HANDLING UNITS SHALL BE TRAPPED. <br />16. THE MECHANICAL CONTRACTOR SHALL PROVIDE REFRIGERANT AND LOW VOLTAGE <br />CONTROL LINES FROM THE CONDENSER TO THE AIR HANDLING UNIT. COORDINATE <br />ROUTING AND INSTALLATION WITH THE GENERAL CONTRACTOR. SIZE REFRIGERANT <br />LINES PER MANUFACTURER'S REQUIREMENTS. <br />17. ELECTRICAL CONTRACTOR TO PROVIDE ALL HIGH VOLTAGE ELECTRICAL WIRING, <br />CONDUIT, DISCONNECT SWITCHES, FUSE5, ECT. TO SPLIT SYSTEM UNITS. ALL <br />FINAL ELECTRICAL CONNECTIONS ARE BY ELECTRICAL CONTRACTOR. <br />18. REFRIGERANT PIPING, NOT SHOWN ON PLANS, SHALL BE 51ZED t INSTALLED IN <br />ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, INSTALLATION <br />INSTRUCTIONS AND LOCAL CODES. <br />19. MECHANICAL CONTRACTOR SHALL VERIFY LOCATION OF ALL PENETRATIONS FOR <br />RELIEF HOODS, OUTSIDE AIR HOODS, LOUVERS, AND WALL CAPS WITH ARCHITECT E <br />OWNER PRIOR TO INSTALLATION. <br />20. MECHANICAL CONTRACTOR SHALL PAINT ALL RELIEF HOODS, INTAKE HOODS, <br />LOUVERS, AND VENT CAPS. CONFIRM COLOR WITH ARCHITECT t OWNER PRIOR TO <br />INSTALLATION. <br />21. THE MECHANICAL CONTRACTOR SHALL COORDINATE THE REQUIRED OPENINGS IN <br />ROOF TRUSSES WITH THE G.C. IN ORDER TO PROVIDE ADEQUATE SPACE, ACCESS <br />AND SUPPORT FOR THE MECHANICAL UNIT. <br />22. THE GENERAL CONTRACTOR 514ALL PROVIDE PLATFORMS AS REQUIRED FOR THE <br />INSTALLATION OF THE MECHANICAL UNIT, AND SUITABLE WALKING SURFACES AND <br />WORKING AREAS FOR ACCESS AND MAINTENANCE. THE MECHANICAL CONTRACTOR <br />SHALL COORDINATE THE REQUIREMENTS FOR THESE ITEMS WITH THE GENERAL <br />CONTRACTOR. <br />VENTILATION CALCULA11ONS <br />VENTILATION CALCULATIONS BASED ON ASHRAE 62.1-200q <br />PTHP-I <br />OFFICE <br />= (58 5QFT) X (5 PER5ON/5QFT) X (5 CFM/PERSON) + (58 SOFT) X (0.06 CFM/SQFT) <br />=2CFM +3CFM <br />= 5 CFM <br />PTHP-I TOTAL: <br />VBz = 5 CFM <br />VOz = VBz/0.8 = 6 CFM <br />SYSTEM PROVIDES 20 CFM TO SPACE. <br />BACKROOM <br />= (125 SQFT) X (0.75 CFM/SQFT) <br />= 94 CFM <br />EF-2 EXHAUSTS A TOTAL OF 200 CFM FROM SPACES. <br />SERVICE BAYS = 1144 SQFT <br />4% = 45.8 SOFT <br />TOTAL OPERABLE AREA SUPPLIED: <br />600 SQFT <br />MECHANICAL LEGEND <br />X'O © ROUND METAL DUCT <br />0 CEILING EXHAUST FAN <br />C CONDENSATE DRAIN <br />MECHANICAL EQUIPMENT <br />TYPE XX <br />if- 3/4' DOOR UNDER CUT <br />THERMOSTAT WIRE <br />PACKAGED THRU-WALL UNIT SCHEDULE <br />SUPPLY - FAN DATA �' <br />CAPACITY WAGITY <br />ELECnwx DATA <br />UNIT <br />AREA _.. _ _� _ ._ _-- __ _ . __ .. _ �_ _._ ... <br />_ _ . MANUFACTURER UNIT UNIT <br />NO. <br />SERVID TOTAL 0/A ' M mcr FAN MOTOR TOTAL AUX. ELEC TOTAL ALE <br />NOTES <br />: VOLT/PH MAX MCA MODEL TOt'NAGE WEK,NT; <br />CR1 CFMIN.WG :RPM KW MBH 1CW MBFI MBH <br />815E (Las) <br />PTHP-I <br />OFFICE 256 20 0.3 E PERMEFRG 5.6 2.0 7.4 5.6 <br />240V/i� 15 114 P�070 3/4 TON 98 I-8 <br />NOTES: <br />I. <br />COOLING CAPACITIES ARE RATED IN ACCORDANCE WITH ARI STANDARD 210/290 AT 95'F AMBIENT OUTDOOR <br />8. CATALOG NUMBERS AND MANUFACTURERS ARE TO <br />AIR TEMP., 80-F DRY BULB, 6TF WET BULB ENTERING AIR TEMP., AND NOMINAL AIR QUANTITY LISTED. <br />INDICATE TYPE AND QUALITY OF UNIT DESIRED. SUBMIT <br />CUTSHEETS OF THESE AND ALTERNATE MANUFACTURERS <br />2. <br />PROVIDE WITH UNIVERSAL POWER CORD (6-15P <br />FOR ARCHITECT AND OWNER APPROVAL PRIOR TO <br />3. <br />PROVIDE WITH DISPLAY MODULE. <br />PURCHASE OF ANY UNITS. INFORMATION ON ALTERNATE <br />UNITS PROPOSED BY THE CONTRACTOR SHALL INCLUDE <br />4. <br />PROVIDE WITH WALL SLEEVE AND SUBBASE INTERNAL DRAIN KIT (PIPE SECONDARY DRAIN TO OUTSIDE) <br />THE ADD/DEDUCT ASSOCIATED WITH ACCEPTANCE OF <br />5. <br />PROVIDE CONDENSATION PUMP (PUMP PRIMARY CONDENSATE TO MOP SINK) <br />THAT UNIT (OR THE ALTERNATE PACKAGE AS A WHOLE). <br />6. <br />PROVIDE ARCHITECTURAL ALUMINUM GRILLE. COLOR TO BE SELECTED BY OWNER. <br />7. <br />MINIMUM 13.0 SEER RATING. <br />FAN SCHEDULE <br />UNIT <br />AREA <br />E <br />TYPE 4 MIN. MOTOR NP <br />MANUFACTURER <br />NO. <br />5ER1/ED <br />CFM S.P. RPM <br />ARRANGFFrIB�T' VOLTAGE <br />t MODEL NO. <br />DRIVE COMCROL <br />SCHFJNE <br />RIEMARICS <br />EF-I <br />EXHAUST TOILET <br />75 MIN 0.25" 950 <br />CEILING WATTS/0.58A <br />GREENNECK <br />DIRECT <br />A <br />I-5 <br />120/I <br />SP-AI10 <br />_ <br />EF 2 <br />. __... _..._ _...._.__._ <br />EXHAUST BACK ROOM <br />_ <br />150 0.25" 1550 <br />_ . <br />51DEWALL I/25 HP/0.7A <br />GREENNECK <br />- <br />DIRECT <br />B <br />1-6 8 <br />120/I0 <br />51-8-440-D <br />' <br />CF-I <br />;CIRCULATION; SERVICE AREA <br />3700 0.2511 1300 <br />WALL MTD 120 14P10 <br />D2LYT N <br />DIRECT <br />B <br />I-6 <br />NOTE5: <br />CONTROL <br />OPTIONS: <br />I. <br />SCREEN 4. <br />INTEGRAL DISCONNECT SWITCH <br />7. U.L./CUL 705 LISTED <br />2. <br />BACKDRAFT DAMPER 5. <br />SPEED CONTROLLER NEAR FAN <br />8. PROVIDE W/GRAVITY DAMPER, WALL <br />A. <br />CONTROL W/ ROOM LIGHTS <br />3. <br />COLOR BY ARCHITECT 6. <br />PROVIDE STARTER AS REQUIRED <br />LOUVER AND MOTOR SIDE GUARD. <br />B. <br />CONTROL W/ T14ERM05TAT <br />C. <br />CONTROL W/ SWITCH <br />D. <br />CONTINUOUS OPERATION <br />UNIT HEATER SCHEDULE <br />TAG <br />LrOCATION <br />MOUNTING CAPAGTY <br />EL6CTRIG4L DATA <br />MANUFAiGTURER 4 MODEL NO. NOTES <br />MBN <br />Im V PH w <br />EH -I <br />TOILET <br />CEILING 2560 <br />0.75 120 10 60 <br />QMARK QCN1151F I-3 <br />EH-2 <br />__...._ _ ..... ............. _.:m..., <br />STORAGE RM <br />_. _ <br />f <br />CEILING 6826 <br />2.0 240 10 60 <br />QMARK QCNI202F 1-3 <br />IRH-1,2 <br />', SERVICE BAYS <br />NOTE 5 20,473 <br />6.0 240 10 60 <br />QMARK BRM M6043B 3-5 <br />NOTES: <br />I. INTERNAL THERMOSTAT 5. CHAIN MOUNT 12'-0' A.F.F. (FIELD COORD. FINAL <br />2. UNIT DISCONNECT MOUNTING HEIGHT WITH OWNER) <br />3. U.L. LISTED <br />4. PROVIDE REMOTE WALL THERMOSTAT <br />HANGER <br />FAN <br />--- :::.. . . . .............. <br />- - :r, <br />EXHAUST DUCT <br />TAGGED NOTES - THIS SHEET <br />O ROUTE FULL SIZE CONDENSATE DRAIN LINE TO <br />MOP SINK. <br />O2 00 EXHAUST DUCT TO EXTERIOR WALL CAP BY <br />FAN MANUFACTURER. <br />O3 84 EXHAUST DUCT TO EXTERIOR WALL CAP BY <br />FAN MANUFACTURER. <br />® CONDENSATE UP IN WALL TO ABOVE CEILING. <br />O SECONDARY CONDENSATE DRAIN TO OUTSIDE. <br />O PROVIDE INSULATED 5U5BA5E. <br />O COORDINATE HEATER LOCATION WITH TAKE 5 <br />REPRESENTATIVE. <br />® CLASS I LIQUIDS ARE NOT USED OR STORED IN <br />THIS BUILDING. <br />O VEHICLES ARE ONLY OPERATED FOR THE <br />DURATION OF MOVING THEM IN AND OUT OF THE <br />GARAGE. <br />10 12"XI2' INTAKE LOUVER EQUIVALENT TO RUSKIN <br />MODEL ELF6375DX WALL LOUVER WITH A MINIMUM <br />OF 2.1 SQFT OF FREE AREA. PROVIDE WITH <br />GRAVITY BACKDRAFT DAMPER. <br />r , 1 MECHANICAL FLOOR PLAN <br />1/4 III= 1 11-0111 <br />2923 South Tryon Street Suite 280 <br />Charlotte, North Carolina 28203 <br />tel 704.373.0068 fax 704.373.0260 <br />MECHANICAL ELECTRICAL PLUMBING <br />a. <br />v <br />-J 0 W <br />�O/ <br />v <br />Z�/ �- <br />L.J- z <br />__� <br />U-c`o O <br />W CO I <br />JNi jQ <br />W <br />O <br />QJ oQ <br />Lf) I.__ J Z F-- <br />WWa: oQ <br />�= SQ <br />`aW � <br />N U- <br />� N O <br />zN� <br />wzo <br />Quo <br />o� <br />0 <br />-�Zp!E <br />�0 <br />Nazi <br />NUa3 <br />Is not to bm c"ged <br />In whob <br />of to be umd aw on ` Jed <br />am! muct be robvned to <br />Amodobw Won <br />Cep ht 2013. cmwm RoEYiwn <br />REV. I DESCRIP71014 <br />09-23-2021 <br />MECHANICAL <br />PLAN <br />mml <br />