My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7631 Gall Blvd (13)
Zephyrhills
>
Building Department
>
Building Plans
>
7631 Gall Blvd (13)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 10:41:11 AM
Creation date
2/18/2025 4:39:36 PM
Metadata
Fields
Template:
Building Plans
Street #
7631
Location
Gall Blvd
Contractor
Waehter Inc
Building Plans - Permit #
2497
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CEILING HEIGHT MOTE <br />CEILING HEIGHT IS 20'-0" IN SALES AND <br />RECEIVING AREAS, AND 10'-0" IN OFFICE AND <br />T.I. AREAS <br />EXISTING <br />3 <br />SUPERVISING STATION ALARM SYSTEMS <br />THE FIRE ALARM SYSTEM WILL BE MONITORED BY <br />A SUPERVISING STATION FOR ELECTRONICALLY <br />MONITORED SPRINKLER SYSTEMS. SEE RISER <br />DIAGRAM ON SHEET EFP2 AND TECHNICAL DATA <br />SHEETS FOR SUPERVISING STATION DETAILS. <br />EXISTING FIRE ALARM INITIATION <br />PVICTINC POINFP <br />PLAN rA—"N"� CLINIC ADDITION <br />SCALE: 1" = 40'-0" EFP1 <br />TED BY AN EXISTING AUTOMATIC FIRE SPRINKLER <br />vl CONSISTS OF THE FOLLOWING: <br />✓ES CONTROLLING THE SPRINKLER SYSTEM. <br />MOKE DETECTORS TO PROTECT THE CPU ("FACP") <br />AS SHOWN <br />UTOMATIC EXTINGUISHING SYSTEMS (ANSUL, ETC.) <br />ARM" CONDITION. <br />UCT SMOKE DETECTORS FOR ALL AC UNITS <br />D CFM. <br />ELECTRONIC FIRE PROTECTION PLAN B Q 4' 8' 16' <br />SCALE: vs" = 1'-0" EFP1 scale: 1 fg" _ 1 ,_o„ <br />FIRE ALARM SYMBOLS LEGEND <br />SYMBOL <br />QTY. <br />DESCRIPTION <br />MAKE/MODEL <br />FRCP <br />EXISTING <br />FIRE ALARM CONTROL PANEL <br />BOSCH D9412G <br />FACU <br />EXISTING <br />FIRE ALARM CONTROL UNIT <br />BOSCH D1256 <br />FAA <br />EXISTING <br />FIRE ALARM ANNUNCIATOR <br />BOSCH D1257 <br />NAC <br />1 NEW <br />NOTIFICATION POWER SUPPLY <br />ALTRONIX AL1002ULADA <br />O <br />1 NEW <br />SMOKE DETECTOR W/ <br />BOSCH D273THE <br />END OF LINE RELAY <br />2 NEW <br />MANUAL PULL STATION <br />BOSCH FMM-100 <br />O <br />EXISTING <br />DUCT SMOKE DETECTOR <br />SYSTEM SENSOR D4120 <br />O <br />32 NEW <br />CEILING MOUNT STROBE <br />SYSTEM SENSOR SCWL <br />MULTI CANDELA <br />CEILING MOUNT HORN/STROBE <br />HS <br />8 NEW <br />MULTI CANDELA <br />SYSTEM SENSOR PC2WL <br />HS <br />3 NEW <br />WALL MOUNT <br />HORN STROBE, MULTI CANDELA <br />SYSTEM SENSOR P2WL <br />EXISTING <br />COOKING HOOD SUPPRESSION <br />(POINT OF CONNECTION ONLY) <br />SYSTEM <br />PT <br />5 NEW <br />POPT MODULE <br />BOSCH D9127U <br />X , <br />EXISTING <br />WATERFLOW INDICATOR SWITCH <br />(PROVIDED BY OTHERS) <br />EXISTING <br />SPRINKLER SYSTEM CONTROL VALVE <br />(PROVIDED BY OTHERS) <br />SUPERVISORY TAMPER SWITCH <br />A—Z <br />END OF LINE RESISTOR/DEVICE <br />PER MANUFACTURER <br />WIRE LEGEND <br />A <br />- _ T _ T _ - <br />FIRE ALARM SYSTEM <br />3pr #18 AWG FPL TWISTED <br />B <br />--------------------- <br />NOTIFICATION CIRCUIT <br />1pr #12 AWG FPL ZIP <br />C <br />MULTIPLE CABLES <br />PLENUM RATED CABLE FPLP SHALL BE UTILIZED IN PLENUM RATED CEILING AREAS ONLY <br />NO PLENUM RATED CEILING IN THIS PROJECT <br />WP = WEATHERPROOF CABLE SHALL BE PROVIDED AS REQUIRED <br />(+) POSITIVE CIRCUIT POLARITY (-) NEGATIVE CIRCUIT POLARITY <br />PS—X — POWER SUPPLY ASSIGNED TO ASSOCIATED CIRCUITS <br />LP— X — LOOP ASSIGNED TO ASSOCIATED POWER SUPPLY. <br />ILD— X DEVICE NUMBER ASSIGNED TO ASSOCIATED LOOP. — — — — — — — — — — — — j <br />ALL NAC CIRCUITS SHALL BE7 <br />12 AWG. ALL OTHER FIRE <br />ALARM WIRE SHALL BE 18 AWG. <br />NOTIFICATION APPLIANCES MUST BE A <br />MINIMUM OF 15dB ABOVE AVERAGE <br />AMBIENT SOUND LEVELS. AVERAGE <br />AMBIENT SOUND LEVEL FOR M <br />OCCUPANCY IS 40 dB. NOTIFICATION <br />APPLIANCES MUST BE AT LEAST 55dB, <br />NOT TO EXCEED 85dB. <br />VISIBLE NOTIFICATION APPLIANCES <br />SHALL BE INSTALLED IN ACCORDANCE <br />WITH NFPA 72 TABLE 18.5.5.4.1(a) OR <br />TABLE 18.5.5.4.1(b) PER <br />SPECIFICATIONS OF NFPA 72 18.5.5.4.2, <br />AND SHALL FLASH IN SYNCHRONIZATION <br />WHERE MORE THAN TWO VISIBLE <br />NOTIFICATION APPLIANCES ARE IN ANY <br />FIELD OF VIEW PER NFPA 72 18.5.5.5.7. <br />STROBE <br />SPACING: <br />CEILING <br />HEIGHT 10' <br />115cd — <br />55' MAXIMUM SPACING <br />75cd — <br />44' MAXIMUM SPACING <br />15cd — <br />20' MAXIMUM SPACING <br />FIRE ALARM SCOPE OF WORK <br />THE EXISTING STORE IS PROTECTED BY AN APPROVED <br />FIRE ALARM SYSTEM. THE SCOPE OF WORK IS THE <br />FOLLOWING: <br />1. INSTALL NEW NOTIFICATION IN THE RETAIL ADDITION <br />AREA. <br />2. INSTALL NEW PULL STATIONS, AND CONNECT TO <br />EXISTING INITIATING LOOP. <br />3. INSTALL NEW POWER SUPPLY, AND ITS MONITORING. <br />4. INSTALL NEW SMOKE DETECTOR TO PROTECT THE <br />POWER SUPPLY. <br />THE EXISTING FIRE ALARM PANEL, AND ALL OTHER <br />EXISTING FIRE ALARM INITIATING AND NOTIFICATION <br />DEVICES SHALL REMAIN. <br />z <br />J <br />z <br />guo <br />4 <br />Zvi <br />CDC <br />O1I.I.I� <br />NAM <br />U ((� <br />�. ' <br />MWVVV <br />E 3 J <br />iA U� �� <br />Q <br />Z <br />pd <br />a <br />w <br />A <br />O 0 <br />O <br />� <br />W <br />O <br />_j� <br />z <br /><t � <br />W <br />0 � <br />O <br />a <br />A <br />0�^ <br />(n <br />Cfl <br />N <br />w <br />z <br />0 <br />ISSUE BLOCK <br />CHECKED BY: RH <br />DRAWN BY: SM <br />FILE NAME: <br />PROTO CYCLE: <br />DOCUMENT DATE: 12-12-20 <br />INSTALLING CONTRACTOR: <br />WACHTER INC <br />1419 W. MONROE <br />LOWELL, AR 72745 <br />OFFICE: 479-725-5551 <br />WACHTER. ALARM @WACHTER. COM <br />ELECTRONIC <br />Date Signed: April 9, 2021 <br />FIRE <br />PROTECTION <br />PLAN <br />SHEET: <br />KEY <br />EFF1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.