Laserfiche WebLink
rmm <br />I 1 _ _ 1 I ! . 1 11 I _. '1..-!-_ I I _ _ I <br />EQUIPMENT SCHEDULE <br />COMMERCIAL SWIMMING POOL <br />FILTRATION AND DISINFECTION SYSTEM <br />ITEM <br />QTY <br />MANUFACTURER <br />PART NUMBER <br />DESCRIPTION <br />EQUIPMENT SET <br />1 <br />AQUAWORX <br />CUSTOM <br />SEE DETAILS SHEET ON SHEET 10 <br />DRAINS AND FITTINGS <br />ITEM <br />QTY <br />MANUFACTURER <br />PART NUMBER <br />DESCRIPTION <br />12" X 12" VGBA CERTIFIED FRAME AND GRATE WITH 90.8 SQ. IN. OPEN AREA W/ <br />CUSTOM MAIN DRAIN SUMP AND 2" HYDROSTATIC RELIEF VALVE (P/N SK43101) <br />SUCTION OUTLET FITTING ASSEMBLY (SOFA) IS VGBA 2017 COMPLIANT WHEN INSTALLED IN ACCORDANCE WITH <br />MD FRAME & GRATE <br />2 <br />AQUASTAR <br />WAV12WRXXX <br />ALL MANUFACTURER INSTRUCTIONS. <br />FLORIDA DOH APPROVED 361 GPM O 1.5 FPS <br />130.0 GPM DESIGN FLOW RATE ® 0.46 FPS <br />OUTLETS SHALL BE COVERED BY A SECURE GRATE WHICH REQUIRES THE USE OF A TOOL TO REMOVE. <br />THREE-PIECE DIRECTIONAL EYEBALL FITTING 1%w KNOCK -IN - 1" EYEBALL <br />WALL INLETS <br />11 <br />AQUASTAR <br />4101 <br />DIRECTIONALLY ADJUSTABLE. <br />260.0 GPM / 23 TOTAL INLETS = 11.3 GPM PER INLET <br />INSTALL ALL RETURN FITTINGS MIN. 1'-0" BELOW OPERATING WATER LEVEL <br />4" ADJUSTABLE FLOOR RETURN FITTING WITH WATER STOP <br />260.0 GPM / 23 TOTAL INLETS = 11.3 GPM PER INLET <br />FLOOR INLETS <br />12 <br />AQUASTAR <br />4DIV101 <br />FLOOR INLETS SHALL BE DESIGNED AND INSTALLED SUCH THAT THEY DO <br />NOT PROTRUDE ABOVE THE POOL FLOOR AND ALL INLETS SHALL BE <br />DESIGNED AND INSTALLED SO AS NOT TO CONSTITUTE SHARP EDGES OR <br />PROTRUSIONS HAZARDOUS TO POOL BATHERS. <br />11.4. SO. IN. OPEN AREA VGBA CERTIFIED OUTLET <br />FLORIDA DoH APPROVED 53.6 GPM ® 1.5 FPS EACH <br />STATIC FITTING <br />1 <br />AQUASTAR <br />6HPXXX <br />FITTINGS TO INSTALLED MIN. 12" BELOW NORMAL OPERATING WATER LEVEL <br />OUTLETS SHALL BE COVERED BY A SECURE GRATE WHICH REQUIRES THE USE OF A TOOL TO REMOVE. <br />GUTTER GRATES <br />31 <br />PENTAIR <br />54-2038 <br />2.5" X 4" PLASTIC W/ 2" I.D. SOCKET <br />UNDERWATER LIGHTING SYSTEM <br />ITEM <br />QTY <br />MANUFACTURER <br />PART NUMBER <br />DESCRIPTION <br />NTELLIBRITE 5G <br />INTELLIBRITE 5G LED UNDERWATER POOL LIGHT (WHITE ONLY) <br />LOW VOLTAGE POOL LIGHTS <br />5 <br />PENTAIR <br />#60110* <br />12 VOLT, 40 WATTS (30OW EQUIVALENCY), UL LISTED. <br />(WHITE ONLY) <br />USE PENTAIR AQUATIC SYSTEMS PLASTIC NICHES P/N 79206700 AND CORD SEAL KIT P/N 670044 <br />*CONFIRM REQUIRED CORD LENGTH PRIOR TO ORDERING <br />LOW VOLTAGE TRANSFORMER <br />2 <br />INTERMATIC <br />PX300 <br />LOW VOLTAGE TRANSFORMER IN WEATHERPROOF ENCLOSURE <br />JUNCTION BOXES <br />2 <br />INTERMATIC <br />PJB4175 <br />JUNCTION BOX IN WEATHERPROOF ENCLOSURE <br />DECK & SAFETY EQUIPMENT <br />ITEM <br />QTY <br />MANUFACTURER <br />PART NUMBER <br />DESCRIPTION <br />CUSTOM 3-BEND HAND RAIL 1.90" O.D. X .065" WALL. 316L MG GRADE STAINLESS STEEL WITH A POLISHED <br />HAND RAIL <br />3 <br />S.R. SMITH <br />CUSTOM <br />AND BUFFED FINISH. THE RAIL SHALL BE ANCHORED IN THE DECK AND THE BOTTOM TREAD. <br />CONFIRM AND TEMPLATE DIMENSIONS PRIOR TO ORDERING. <br />ANCHOR <br />6 <br />S.R. SMITH <br />AS-100B <br />EACH ANCHOR SHALL BE PROPERLY GROUNDED IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE <br />STANDARDS. <br />ESCUTCHEON PLATE <br />6 <br />S.R. SMITH <br />EP-10OF <br />STAINLESS STEEL COVER PLATE. <br />RING BUOY <br />2 <br />RECREONICS, INC. <br />12-252 <br />USCG APPROVED (WHITE). <br />RING BUOY HOLDER <br />2 <br />RECREONICS, INC. <br />12-259 <br />STAINLESS STEEL <br />RING BUOY ROPE <br />2 <br />RECREONICS, INC. <br />12-261 <br />60, <br />FIBERGLASS POLE <br />2 <br />RECREONICS, INC. <br />12-220 <br />16' <br />SHEPARDS CROOK <br />2 <br />RECREONICS, INC. <br />12-230 <br />ALUMINUM <br />POLE CLAMPS <br />4 <br />RECREONICS, INC. <br />10-353 <br />STAINLESS STEEL <br />PORTABLE VACUUM <br />1 <br />WATERTECH <br />CAT FISH LI <br />POOL BLASTER SERIES <br />TEST KIT <br />1 <br />TAYLOR <br />#2005-K <br />CAPABLE OF MEETING ALL CHEMICAL TESTS SPECIFIED BY THE FLORIDA ADMINISTRATIVE CODE IN CHAPTER <br />64E-9 <br />SHOWER (BY OTHERS) <br />1 <br />T <br />LOCATE WITHIN LIMITS OF APPROVED POOL BARRIER. <br />NOTE: <br />RECIRCULATION AND TREATMENT <br />EQUIPMENT SHALL BE TESTED AND <br />APPROVED IN ACCORDANCE WITH <br />NSF/ANSI STANDARD 50 ONLY NSF-60 <br />APPROVED CHEMICALS SHALL BE USED <br />IN POOL. <br />ONLY 1OX SODIUM HYPOCHLORITE SHALL <br />BE USED IN CHLORINE FEED SYSTEM. <br />NOTE: ALL METAL LOCATED <br />WITHIN 5 FEET OF POOL WATER <br />SHALL BE BONDED. <br />PAVER BRICK <br />ON SAND <br />NOTE: <br />WEATHERPROOF/WATERPROOF <br />DISCONNECT SWITCHES TO <br />DISABLE POWER TO POOL <br />HEATERS BY OTHERS. <br />LOCATE WITHIN LINE OF SIGHT <br />OF EQUIPMENT AND MIN. 5' <br />REACH DISTANCE FROM POOL <br />WATER. LOCATION SHALL <br />COMPLY WITH FBC-B CH. 27 <br />AND NEC <br />(BY OTHERS - REFER TO <br />ELECTRICAL DRAWINGS BY <br />OTHERS FOR FINAL SWITCH AND <br />DISCONNECT LOCATIONS). <br />SLAB WIRE <br />#5 FOOTER STEEL <br />S/S LADDER AND <br />HANDRAIL <br />WEDGE ANCHOR <br />WITH GROUNDING <br />SCREW <br />JUNCTION BOXES TO BE LOCATED A <br />MINIMUM OF 4 FEET FROM WATER'S <br />EDGE AND 12" ABOVE COPING OR <br />DECK <br />-m --< <br />/ I / :0Vjoi�-ice �'�`'��=��-►�'���'�f�►������� <br />doo <br />- <br />•COPPER <br />�N'EINFORCING STEEL <br />-�WIRE 18" TO 24m FROM <br />GRADEFOR POOLS WITH NO DECKS OR BURIED 4" TO 6" BELOW <br />PAVER DECKS REBAR SHALL BE <br />TIED TO WALL STEEL AND <br />BROUGHT OUT OF <br />POOL BONDING DETAIL <br />RECIRC <br />PUMP <br />\ #8 SOLID <br />COPPER WIRE <br />FOUR (4) EQUALLY SPACED WALL REBARS <br />AROUND POOL OR (4) INSULATED #8 WIRE <br />IN PLACE OF REBAR <br />-APPROVED CONNECTOR <br />NOTE: IF REBAR IS 18" TO 24" <br />IN HORIZONTAL LENGTH, THE <br />PERIMETER BONDING WIRE MAY <br />BE CONNECTED DIRECTLY TO <br />REBAR WITHOUT JUMPER. <br />POOL EQUIPMENT NOTES: <br />1. THE POOL RECIRCULATION PUMP(S) ARE <br />SELF -PRIMING AND ARE PROVIDED WITH A HAIR <br />AND LINT STRAINER. <br />2. ALL P.V.C. PIPE SHALL BE SCHEDULE 40 (SCHEDULE <br />80 WHERE REQUIRED BY LOCAL CODE) AND BE <br />IMPRINTED WITH THE MANUFACTURES NAME AND <br />THE NSF-PW LOGO. (COLLAPSE RATINGS SHALL BE <br />IN EXCESS OF THE EXTERNAL PRESSURES ON THE <br />INSTALLED PIPE). PVC PIPE EXPOSED TO SUN <br />LIGHT SHALL BE COATED FOR U.V. PROTECTION. <br />3. ALL FLOW CONTROL VALVES SHALL BE <br />PROPORTIONAL CONTROL TYPE (GATE VALVES ARE <br />NOT ACCEPTABLE FOR THIS PURPOSE) RETURN, <br />MAIN DRAIN, AND SURFACE OVERFLOW SYSTEM <br />LINES SHALL EACH HAVE VALVES DESIGNED FOR <br />PROPORTIONAL FLOW. <br />4. CLEARANCE FOR ALL FLOW METERS SHALL BE AS <br />RECOMMENDED BY THE MANUFACTURER. <br />NORMAL OPERATING WATER LEVEL <br />LOW VOLTAGE (12V) <br />POOL UNDERWATER LIGHT <br />IN STAINLESS STEEL NICHE. <br />INSTALL AND BOND LIGHT AND NICHE <br />IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS <br />AND JURISDICTIONAL REQUIREMENTS. <br />NOTE: <br />COMPONENTS AND MATERIALS SHALL BE TESTED <br />AND APPROVED USING THE NSF/ANSI STANDARD <br />50, CIRCULATION SYSTEM COMPONENTS AND <br />RELATED MATERIALS FOR SWIMMING POOLS, <br />SPAS/HOT TUBS, DATED APRIL 2007, WHICH IS <br />INCORPORATED BY REFERENCE. <br />NOTE: MINIMUM 7'-0" CLEAR <br />HEADROOM SHALL BE PROVIDED <br />ABOVE ALL ACCESSIBLE AREAS. <br />EQUIPOTENTIAL BONDING GRID: <br />1. EQUIPOTENTIAL BONDING IN ACCORDANCE WITH NEC 680.26 SHALL BE PROVIDED. <br />2. THE PERIMETER SURFACE TO BE BONDED SHALL BE CONSIDERED TO EXTEND FOR 1 M (3 FT) HORIZONTALLY <br />BEYOND THE INSIDE WALLS OF THE POOL AND SHALL INCLUDE UNPAVED SURFACES AND OTHER TYPES OF <br />PAVING. <br />3. BONDING FOR PERIMETER SURFACES SHALL BE PROVIDED AS SPECIFIED IN 680.26(B)(2)(A) OR 680.26(B)(2)(B), <br />AND ATTACHED TO THE POOL REINFORCING STEEL OR COPPER CONDUCTOR GRID AT A MINIMUM OF FOUR (4) <br />POINTS UNIFORMLY SPACED AROUND THE PERIMETER OF THE POOL. FOR NON-CONDUCTIVE POOL SHELLS, <br />BONDING AT FOUR POINTS SHALL NOT BE REQUIRED. <br />4. STRUCTURAL REINFORCING STEEL STRUCTURAL REINFORCING STEEL SHALL BE BONDED IN ACCORDANCE WITH <br />680.26(B)(1)(A). <br />5. ALTERNATE MEANS. WHERE STRUCTURAL REINFORCING STEEL IS NOT AVAILABLE COPPER CONDUCTORS SHALL BE <br />UTILIZED WHERE THE FOLLOWING CONDITIONS ARE MET- <br />A. MATERIALS AND CONNECTIONS. BONDING SHALL BE BY MEANS OF AT LEAST ONE MINIMUM 8 AWG BARE <br />SOLID COPPER CONDUCTOR. THE CONDUCTORS SHALL FOLLOW THE CONTOUR OF THE PERIMETER SURFACE. <br />B. APPROVED SPLICES SHALL BE PERMITTED. IF ONLY A SINGLE CONDUCTOR IS PROVIDED, IT SHALL BE 450 <br />TO 600 MM (18 TO 24 INCHES) FROM THE INSIDE WALL OF THE POOL. <br />C. SECURING. PERIMETER SURFACE EQUIPOTENTIAL BONDING CONDUCTORS SHALL BE SECURED WITHIN OR <br />UNDER THE PERIMETER SURFACE. AN EQUIPOTENTIAL BONDING CONDUCTOR UNDER THE PERIMETER SURFACE <br />SHALL BE CONSIDERED SECURED WHEN INSTALLED 100 TO 150 MM (4 TO 6 INCHES) BELOW THE SUBGRADE. <br />NOTES: <br />1) ALL ELECTRIC SHALL COMPLY WITH FBC-B CH. 27 (2020) AND NEC (2017) <br />2) ALL ELECTRIC WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN COMPLIANCE WITH FBC <br />2017. <br />3) LICENSED ELECTRICAL CONTRACTOR SHALL CONFIRM ALL ELECTRICAL REQUIREMENTS PRIOR TO STARTING WORK. <br />4) LICENSED ELECTRICAL CONTRACTOR SHALL CHECK AND VERIFY FURNISHED EQUIPMENT AGAINST SPECIFIED OR <br />INTENDED ITEMS AND REVISE BRANCH CIRCUITS AS REQUIRED WITH PRIOR APPROVAL OF ENGINEER. <br />5) LICENSED ELECTRICAL CONTRACTOR SHALL VERIFY ALL EQUIPMENT FOR PROPER VOLTAGE, PHASE, AND CURRENT <br />BEFORE CONNECTION TO CIRCUITS. <br />6) ALL EQUIPMENT SHALL BE PROVIDED WITH GFCI PROTECTION PER NEC 680. <br />7) ALL EQUIPMENT SHALL BE U.L. APPROVED. <br />8) CIRCUITS SHOWN ON PLANS ARE TO DETERMINE LOAD DATA AND PANEL SIZE ONLY. THE LICENSED ELECTRICAL <br />CONTRACTOR SHALL PROVIDE CIRCUITS TO SUIT JOB CONDITIONS. ANY DEVIATIONS FROM THE APPROVED PLANS <br />SHALL GENERATE A REVISION AND REVISED PLANS SHALL BE PRESENTED FOR REGULATORY REVIEW AND <br />APPROVAL PRIOR TO FINAL INSPECTION. <br />9) ALL ELECTRICAL EQUIPMENT AND WIRING SHALL BE RATED FOR MIN. 75-C CONTINUOUS DUTY. <br />10) DISCONNECT SWITCHES SHALL BE H.P. RATED, HEAVY DUTY, QUICK MAKE, QUICK BREAK, WITH ENCLOSURES AS <br />REQUIRED BY EXPOSURE. <br />11) UNLESS OTHERWISE NOTED, ALL CONDUCTORS SHALL BE COPPER THHN/THWN-2. ALL CONDUCTORS #10 AND <br />SMALLER MAY BE SOLID. ALL CONDUCTORS #8 AND LARGER SHALL BE STRANDED. <br />12) THE ELECTRICAL SYSTEM SHALL BE COMPLETELY AND EFFECTIVELY GROUNDED AS REQUIRED IN ART. 250, NEC. <br />13) ALL BONDING SHALL CONFORM TO NEC 680. <br />14) OUTLETS SUPPLYING PUMP MOTORS CONNECTED TO SINGLE-PHASE 120-VOLT THROUGH 240-VOLT BRANCH <br />CIRCUITS, WHETHER BY RECEPTACLE OR BY DIRECT CONNECTION, AND OUTLETS SUPPLYING OTHER ELECTRICAL <br />EQUIPMENT AND UNDERWATER LUMINAIRES OPERATING AT VOLTAGES GREATER THAN THE LOW VOLTAGE <br />CONTACT LIMIT, CONNECTED TO SINGLE-PHASE, 120 VOLT THROUGH 240 VOLT BRANCH CIRCUITS, RATED 15 OR <br />20 AMPERES, WHETHER BY RECEPTACLE OR BY DIRECT CONNECTION, SHALL BE PROVIDED WITH GROUND -FAULT <br />CIRCUIT INTERRUPTER PROTECTION FOR PERSONNEL <br />15) ELECTRICAL EQUIPMENT WIRING AND INSTALLATION, INCLUDING THE BONDING AND GROUNDING OF POOL <br />COMPONENTS SHALL COMPLY WITH CHAPTER 27 OF THE FLORIDA BUILDING CODE, BUILDING. AND 2017 NATIONAL <br />ELECTRICAL CODE (NEC), NFPA 70, INCLUDING NEC CHAPTER 680. <br />16) NEC 430.32 CONTINUOUS -DUTY MOTORS SUCH AS POOL PUMP MOTORS SHALL HAVE OVERLOAD PROTECTION. <br />17) NO ELECTRIC OVER 12V SHALL BE PERMITTED WITHIN 5' OF POOL WATER. <br />18) ALL ELECTRIC LESS THAN 10' FROM POOL WATER SHALL BE GFCI PROTECTED. <br />MIN. <br />1'-6" <br />TO TOP <br />OF LENSE, TYP. <br />JUNCTION BOX. LOCATE IN ACCORDANCE WITH THE NEC. <br />DO NOT LOCATE LESS THAN 4' FROM WATER'S EDGE PER NEC. <br />5'-0" MIN. <br />4'-0" MIN. <br />8" MIN. <br />F ABOVE <br />MAX. <br />WATER LEVEL <br />OUTSIDE <br />OF DECK <br />BOND LIGHT AND NICHE <br />CONTINUE <br />REINFORCED <br />CONCRETE RIGID PVC CONDUIT <br />BEHIND LIGHT TO COMPLY W/ NEC 680.23 (B)(2) <br />NICHE (SEE ELECTRICAL <br />DRAWINGS BY OTHERS) <br />NOTE: <br />ALL ELECTRICAL WORK SHALL BE PERFORMED BY LICENSED CONTRACTORS ONLY. <br />ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE W/ ARTICLE 680 N.E.C. AND ALL <br />JURISDICTIONAL REQUIREMENTS. THE CONTRACTOR IS RESPONSIBLE FOR MEETING THESE <br />CRITERIA. <br />UNDERWATER LIGHT DETAIL <br />SCALE: N.T.S. <br />HANDRAIL <br />OR <br />LADDER <br />TIGHTENING <br />SCREW <br />FrLUG <br />SCREW <br />AND <br />GROUND / fWIRE <br />ESCUTCHEON <br />PLATE <br />LOW VOLTAGE <br />TRANSFORMER IN WEATHERPROOF ENCLOSURE <br />CONNECT BOND WIRE TO <br />DECK POOL REINFORCING W/ <br />BY AN APPROVED BONDING <br />OTHERS CLAMP <br />BRASS <br />ANCHOR <br />SOCKET <br />REFER TO <br />MANUFACTURER <br />FOR REQUIREMENTS <br />ANCHOR IN <br />ACCORDANCE WITH <br />MANUFACTURER <br />INSTRUCTIONS USING " <br />NON -SHRINK GROUT <br />AND WATERPROOFING <br />REFER TO MANUFACTURER <br />FOR REQUIREMENTS <br />ANCHOR DETAIL <br />SCALE: N.T.S. <br />ALL ELECTRICAL WORK SHALL BE PERFORMED BY LICENSED <br />CONTRACTORS ONLY. <br />ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE W/ <br />ARTICLE 680 N.E.C. AND ALL JURISDICTIONAL REQUIREMENTS. <br />THE CONTRACTOR IS RESPONSIBLE FOR MEETING THESE CRITERIA. <br />WP TRANSFORMER BOX <br />WP JUNCTION BOX OR WP GUTTER <br />REFER TO AREA PLAN <br />J-BOX/TRANSFORMER LOCATIONS <br />TO GFCI, CIRCUIT BREAKER, <br />TIMER, AND PANEL <br />(BY OTHERS - SEE ELECTRICAL <br />DRAWINGS FOR CONTINUATION) <br />STAINLESS STEEL UNISTRUT FRAME • • ALL ELECTRICAL WORK SHALL BE <br />J-BOX SHALL PERFORMED BY LICENSED <br />COMPLY W/ CONTRACTORS ONLY. <br />NEC 680.24 • <br />DECK LEVEL, ALL WORK SHALL BE PERFORMED <br />MAX. WATER LEVEL IN STRICT COMPLIANCE W/ ARTICLE <br />OR BFE+1' I I I MIN. 680 N.E.C. AND ALL <br />(WHICHEVER IS GREATER) I I I 8» JURISDICTIONAL REQUIREMENTS. <br />THE CONTRACTOR IS RESPONSIBLE <br />I I FOR MEETING THESE CRITERIA. <br />z <br />-I <br />w� <br />0 <br />� <br />Q�z <br />Z <br />0 <br />O <br />U <br />0 <br />I-U <br />U <br />ry <br />��0 <br />o <br />Lit <br />c-) <br />O <br />as <br />0- <br />Z <br />- <br />-'N <br />LLJ <br />C4 <br />Cd <br />� � N <br />00 <br />� N <br />0 NM M <br />O <br />L� 0 � 1 � <br />OQ F� <br />V <br />00 <br />Ld <br />Wcr <br />Mo <br />w <br />z <br />�00 <br />N 00 <br />�n�N� <br />I00 <br />o-Juj Gw <br />cV <br />w 0 CC) <br />Go <br />COX <br />Li <br />rya v X�- <br />0wQ <br />Noou.J <br />a <br />I <br />W <br />PROJECT NO. <br />22CO93 <br />aR o <br />�6� zw <br />z <br />; <br />0WL)u- Qp� <br />lox<* zQQ <br />rz 2 0 <br />Oww <br />a�=o 0 V) G: <br />� <br />caw 6 mom <br />W <br />0I�iQU <br />�Q> <br />z_oLL1a ow <br />o iE z <br />0 z <br />0 <br />_ <br />U <br />Q . (OjWw- <br />0wwz <br />w�� oo� <br />�? k�,ao <br />N<owo- n z0�J' <br />�NwFSw <br />0.0cnw <br />David <br />Digitally signed <br />by David <br />Faerman, RE <br />�,,,1��11�1►�,,,, <br />1•FAER,yq%, <br />Faer m <br />Date: <br />��,•�Pv�p <br />,..•` o e7o*�N G E N SF....y <br />2023.01.13 <br />�� G <br />* :J No. 47646 <br />an, <br />RE <br />16:27:05-051001 <br />STATE OF <br />4NALE��:�`��. <br />111nn11%10 <br />01 /13/2023 <br />DAVID I FAERMAN, P.E. <br />FL LICENSE NO. 47646 <br />�4, III 4� <br />CONCRETE TO ANCHOR POSTS <br />. ,• ; •, � III .',• :., . <br />RIGID CONDUIT FROM POOL LIGHTS •' 7. ' I I I •' ' :� <br />-------------�/ <br />J-BOX/TX MOUNTING <br />SCALE: N. T. S. <br />PERMIT SET <br />SHEET <br />11 OF 11 <br />