My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36819 Eiland Blvd Unit 1
Zephyrhills
>
Building Department
>
Building Plans
>
36819 Eiland Blvd Unit 1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 11:03:48 PM
Creation date
2/19/2025 8:00:27 AM
Metadata
Fields
Template:
Building Plans
Street #
36819
Location
Eiland Blvd Unit 1
Contractor
Wallace Associates
Building Plans - Permit #
14183
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DOOR AND HAFFDWAF;r= SCHEDULE <br />O EXISTING DOOR SYSTEM. RE -KEY AS REQUIRED. <br />3'-0" X 1'-0" X 1 3/4" S.C. WOOD DOOR AND HOLLOW METAL FRAME WITH PASSAGE <br />HARDWARE SET - SEE DETAIL C/Aib. <br />© PAIR 2'-6" X 1'-0" X 1 3/4" S.C. WOOD DOOR AND HOLLOW METAL FRAME WITH STORE <br />ROOM HARDWARE LOCK SET - SEE DETAIL C/Alb. <br />3'-0" X 1'-0" X 1 3/4" S.C. WOOD DOOR AND HOLLOW METAL FRAME WITH PRIVACY <br />HARDWARE LOCK SET - SEE DETAIL C/AIb. <br />O 3'-0" X -1'-0" X 1 3/4" S.C. WOOD DOOR AND HOLLOW METAL FRAME WITH STORE ROOM <br />HARDWARE LOCK SET - SEE DETAIL C/Ala. <br />3'-0" X 1'-0" X 1 3/4" S.G. WOOD DOOR AND HOLLOW METAL FRAME WITH OFFICE HARDWARE <br />LOCK SET - SEE DETAIL C/Aib. <br />HINGES CAL -ROYAL - U526D - 5531xUS26,T5H31xU526 <br />CLOSER LGN - U526D - 1460/1441 <br />WALL STOP GAL -ROYAL - U626D - CONW542 <br />FLOOR STOP CAL -ROYAL - U926D - DSHPIS <br />PASSAGE SET SCHLAGE - U526D - SATURN AL10S <br />PRIVACY SET SCHLAGE - U826D - SATURN AL408 <br />LOCK SET SCHLAGE - U6260 - SATURN AL50PD <br />SINGLE DUMMY TRIM SCHLAGE - U626D - SATURN ALI-10 <br />STOREROOM LOCK SCHLAGE - U52(bD - SATURN AL50PD <br />CLA55ROOM LOCK :SCHLAGE - U526D - SATURN AL10PD <br />THRESHOLD : PEMKO - ALUM - 210A or MOA <br />DOOR SWEEP : PEMKO - ALUM - 315CN <br />PULL HANDLE DON-JO - U5260 - 1114 <br />KICK PLATE DON-JO - ALUM - J102 <br />PANIC DEVICE :MONARCH - MAL - ISIOLDANE <br />C)OOR GENE RAL NOTES <br />1. ALL DOORS/DOOR OPENINGS SHALL COMPLY WITH FLORIDA FIRE PREVENTION CODE <br />2010 EDITION / NFPA 101 LIFE SAFETY CODE <br />-1.2.1.2 WIDTH <br />12.1A SWING AND FORCE TO OPEN <br />-12.1.5 LOCKS AND LATCHES AND ALARM DEVICES <br />12.1.6 SPECIAL LOCKING ARRANGEMENTS <br />12.1.1 PANIC HARDWARE AND FIRE EXIT DEVICES <br />12.1.6 SELF CLOSING DEVICES <br />2. ALL DOOR HANDLES SHALL BE LEVER TYPE MEETING A.D.A. REQUIREMENTS. <br />3. ALL INTERIOR DOOR HANDLES SHALL BE SCHLAGE "AL" SERIES "SATURN" <br />4. ALL DOORS WITH AUTO CLOSERS SHALL HAVE BALL BEARING TYPE HINGES <br />5. ALL NEW INTERIOR DOORS SHALL BE BIRCH VENEER. <br />6. DOOR CLOSER SHALL BE INSTALLED SUCH THAT THE SWEEP PERIOD OF THE CLOSER SHALL BE <br />ADJUSTED SO THAT FROM AN OPEN POSITION OF 10', THE DOOR WILL TAKE AT LEAST 3 SECONDS <br />TO MOVE TO A POINT 3 INCHES (16MM) FROM THE LATCH, MEASURED TO THE LEADING EDGE OF <br />THE DOOR. <br />1. THE MAXIMUM FORCE FOR PUSHING OR PULLING AN INTERIOR DOOR SHALL BE 51bf (222N). <br />S. PROVIDE EITHER WALL OR FLOOR STOPS FOR ALL DOORS AS REQUIRED. <br />S. SUBMIT HARDWARE SCHEDULE AND REVIEW WITH ARCHITECT PRIOR TO PLACING ORDER (3 COPIES) <br />10. PROVIDE AUTOCLOSER AT BREAKROOM AND WAITING AREA DOORS. <br />CABINET IN NON RATED WALL <br />MODEL NO. 1021F12 AS MANUFACTURED BY J.L. <br />INDUSTRIES. <br />CABINET IN RATED WALL <br />MODEL NO. 1021FI2 FX AS MANUFACTURED BY J.L. <br />INDUSTRIES AT 6" WALLS <br />MODEL NO. 1022FI2 FX AS MANUFACTURED BY J.L. <br />INDUSTRIES AT 4" WALLS <br />FIRE <br />EXTINGUISHER <br />SEE SPECS. <br />BOTTOM OF CABINET <br />TOP OF WALL <br />FLOOR SLAB <br />OFIRE EXTINGUISHER <br />SCALE: 1 1/2" = 1'-0" <br />GYPSUM <br />WALLBOARD <br />PER WALL TYPE <br />4" METAL STUDS <br />AT 1(o" O.C. <br />O FLOOR PLAN <br />SCALE: 3/16" - I'-0" <br />O <br />O <br />°000000 <br />00000o r� <br />000°000 <br />000000 <br />0000000 <br />000000 <br />000000 <br />000000 <br />00000 <br />0000000 <br />O <br />°0000 oo <br />000000 <br />0000000 <br />'.00000 <br />°0000° <br />ao00O° <br />°00000 <br />000000 <br />000000 <br />00000 <br />0000 <br />. 000 .°0000 <br />000000 <br />000000 <br />O <br />1 /A3a <br />EXAM <br />115 <br />1/A3a EXAM <br />/1 119 <br />�1 <br />EXAM <br />1/A3a 121 <br />1/A3b <br />Q1 STATION Q MIRR.0 i <br />106 1/A3b <br />TOILET N <br />122 I 24 <br />r--_1 19 <br />HI <br />El E:1 L__J <br />20 I I 23 26 0 <br />2 <br />3 <br />'-(D-\ <br />16 15 <br />CL. <br />105 <br />29 <br />I <br />i <br />CL. 20 <br />EXAM 1/A3a <br />i <br />104 <br />D <br />15 <br />16 Il <br />' <br />i <br />® <br />_i <br />Jc <br />Lro®�� J <br />I <br />1 <br />' <br />(Q <br />RECE3PTIONQ <br />� <br />i <br />/ <br />m 102 a <br />I <br />i <br />01 <br />4/A3a 15 <br />I <br />i <br />I <br />i <br />I <br />i <br />i <br />i <br />1 <br />21 <br />14 <br />12 <br />21 <br />/\ <br />n� <br />II <br />1/A3a <br />I <br />21 l <br />i <br />WALL LEGEND <br />JEXISTING DOOR SYSTEM <br />® EXISTING WINDOW SYSTEM <br />EXISTING MASONRY WALL SYSTEM WITH NEW WALL <br />FINISH - SEE GENERAL NOTE <br />4" <br />YP;, O <br />DOOR SYSTEM - REFER TO DOOR SCHEDULE <br />METAL STUD PARTITION - REFER TO TYPICAL NON -RATED <br />WALL PARTITION DETAIL B/Alb <br />METAL STUD SOUND INSULATED PARTITION - REFER TO <br />TYPICAL NON -RATED WALL PARTITION DETAIL B/AIb. <br />— — — ONE (1) HOUR RATED TENANT SEPARATION PARTITION - <br />REFER TO DETAIL A/AIb. <br />KEYED NOTES <br />OHATCH INDICATES AREA OF NO WORK. <br />OEXISTING WINDOW SYSTEM. <br />( EXISTING MASONRY WALL SYSTEM. <br />O4 EX15TING CONCRETE SIDEWALK <br />5O EXISTING HANDICAP LOADING ZONE <br />OEXISTING HANDICAP PARKING SPACE <br />OEXISTING LANDSCAPE AREA <br />OEXISTING ELECTRICAL TRANSFORMER <br />OEXISTING BIKE RACK. <br />10 NEW MECHANICAL UNITS - SEE MECHANICAL DRAWINGS. <br />11 COPIER - PROVIDED BY TENANT. <br />12 ALUMINUM SLIDING WINDOW SYSTEM - SEE INTERIOR ELEVATIONS. <br />13 42" HIGH WALK-UP COUNTER - SEE INTERIOR ELEVATIONS. <br />14 36" HIGH WRITING COUNTER - SEE INTERIOR ELEVATIONS. <br />15 BASE CABINETS / COUNTERTOP - SEE INTERIOR ELEVATIONS. <br />16 WALL MOUNTED UPPER CABINETS - SEE INTERIOR ELEVATIONS. <br />Il SINK - SEE PLUMBING. <br />15 PHONE / DATA BOARDS - SEE ELECTRICAL DRAWINGS. <br />19 SCALE - BY TENANT. <br />20 HI-LO DRINKING FOUNTAINS - SEE PLUMBING DRAWINGS. <br />21 WALL MOUNTED T.V. BY TENANT PROVIDE WALL BLOCKING AS <br />REQUIRED - SEE ELECTRICAL DRAWINGS FOR MORE INFORMATION. <br />VERIFY FINAL LOCATION AND SIZE WITH TENANT. <br />22 REFRIGERATOR - BY TENANT. <br />23 6" WALL SYSTEM <br />24 SPECIMEN PASS-THRU CABINET - SEE DETAIL E/Alb. <br />25 ELECTRICAL PANEL - SEE ELECTRICAL DRAWINGS. <br />26 FIRE EXTINGUISHER CABINET - SEE DETAIL A/Ala. <br />21 WOOD VENEER PANELS - SEE INTERIOR ELEVATIONS. <br />28 ADJUSTABLE SHELVING - SEE DETAIL A/A3b <br />29 ONE (1) HOUR RATED TENANT SEPARATION PARTITION - REFER TO <br />DETAIL A/Aib. <br />30 EXISTING ELECTRICAL SERVICE - SEE ELECTRICAL DRAWINGS. <br />GENE Rr4L NOTES <br />1. ALL INTERIOR WALLS ARE NOMINAL 4" METAL STUDS U.ON. <br />2. ALL NEW G.W.S. TO BE LEVEL FOUR (4) FINISH. <br />3. GENERAL CONTRACTOR SHALL COORDINATE INSTALLATION AND <br />ASSIST EQUIPMENT VENDOR WITH ALL OFFICE EQUIP. "BY TENANT' <br />4. GENERAL CONTRACTOR TO NOTIFY ARCHITECT AFTER LAYOUT IS <br />DONE AND WALL TRACK IS IN PLACE PRIOR TO FRAMING ANY WALLS <br />5. GENERAL CONTRACTOR TO NOTIFY ARCHITECT OF ANY <br />DISCREPANCIES PRIOR TO COMMENCING WITH ANY WORK <br />6. PROVIDE 1/2" G.W.B. OVER Ix3 FURRING STRIPS OVER i" RIGID <br />INSULATION ON INSIDE OF EXISTING CMU WALLS (TYP.) <br />1. GENERAL CONTRACTOR TO PROVIDE WOOD BLOCKING IN WALLS AS <br />REQUIRED FOR NEW CABINETRY, ACCESSORIES, ETC. <br />S. GENERAL CONTRACTOR TO MAINTAIN INTEGRITY OF ALL EXISTING <br />STRUCTURAL ELEMENTS. <br />9. PROVIDE 4" THICK 3000 PSI CONCRETE SLAB WITH 6 x fo - W1.4 x <br />W1.4 UJUXI OVER (o MIL VAPOR BARRIER OVER CLEAN, COMPACTED <br />TERMITE TREATED FILL. <br />10. SEE ELECTRICAL DRAWINGS FOR MORE INFORMATION. <br />11. SEE MECHANICAL DRAWINGS FOR MORE INFORMATION. <br />12, SEE PLUMBING DRAWINGS FOR MORE INFORMATION. <br />13. SEE SHEET D/Alc FOR TYPICAL MANEUVERING CLEARANCES AT <br />DOORWAYS. <br />H:\ProjectsTrojects 2013\13008 - FMC Dialysis Ctr - Eilattd\04-CD\13008b - FMC Dialysis Ctr\04-Architectuml\A01 a-FLPL.dwg, 4/16/2013 9:11:42 AM, DC <br />
The URL can be used to link to this page
Your browser does not support the video tag.