WIND INFORMATION <br />I m SPECIFICATION-S.. <br />1, 1. CONSTRUCTION: <br />1. 1. 1. ACI 318 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, LATEST EDITION <br />1.1.2. ACI-ASCE 530, SPECIFICATIONS FOR MASONRY STRUCTURES, LATEST EDITION <br />1.1.3. ASTM C270, C476, C270 AND C90 SPECIFICATIONS FOR MASONRY STRUCTURES <br />1.1.4. NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION LATEST EDITION AND ALL <br />ACCOMPANYING SUPPLEMENTS. <br />1.1.5. THE FLORIDA BUILDING CODE: LATEST EDITION <br />1. 2. DESIGN: <br />1.2.1. ACI 318 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, LATEST EDITION <br />1.2.2. ACI-ASCE 530, SPECIFICATIONS FOR MASONRY STRUCTURES, LATEST EDITION <br />1.2.3. ASTM SPECIFICATIONS FOR MASONRY STRUCTURES <br />1.2.4. NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION, LATEST EDITION AND ALL <br />ACCOMPANYING SUPPLEMENTS. <br />1.2.5. NATIONAL FOREST PRODUCTS ASSOCIATION, LATEST EDITION <br />1.2.6. THE FLORIDA BUILDING CODE SBCCI : LATEST EDITION <br />1, 3. GEOMETRIC CONTROL: <br />1.3. 1. ELEVATIONS ARE BASED ON NATIONAL GEODETIC VERTICAL DATUM OF 1988 (NAVD <br />1988). SURVEY INFORMATION PROVIDED BY OWNER/CONTRACTOR. <br />1. 4. SHOP DRAWINGS: <br />1.4. 1. THERE SHALL NOT BE ANY DEVIATIONS FROM THESE DESIGN PLANS BY OTHERS DURING THE PREPARATION OF SHOP <br />DRAWINGS WITHOUT WRITTEN <br />APPROVAL FROM THE ENGINEER OF RECORD. <br />ALL SHOP DRAWINGS ARE TO BE SUBMITTED TO THE ENGINEER OF RECORD PRIOR TO THE COMMENCEMENT OF <br />1.4.2. CONSTRUCTION. <br />ALL ITEMS IDENTIFIED OR INTENDED TO BE DESIGNED BY OTHERS REQUIRE SHOP DRAWINGS TO BE SIGNED AND SEALED <br />AND SHALL INCLUDE; DRAWINGS <br />1.4.3. AND CALCULATIONS, REACTIONS AND BEARING POINTS, BRACING REQUIREMENTS, LIFTING LOCATIONS, AND CONNECTIONS <br />TO SUPPORTING TRUSS <br />MEMBERS. <br />2. <br />DESIGN'' LOADS ..______­_.__.­_1 <br />2. <br />1. <br />DEAD LOADS: <br />2. 1. 1. UNIT WEIGHT OF SOIL, COMPACTED: <br />120 PCF <br />2.1.2. UNIT WEIGHT OF REINFORCED CONCRETE: <br />150 PCF <br />2.1.3. UNIT WEIGHT OF 8" C.M.U. BLOCK: <br />55 PSF <br />2.1.4. 1ST FLOOR SUPERIMPOSED LOAD: <br />20 PSF <br />2.1.5. UNIT WEIGHT OF 2x4 PARTITION WALLS: <br />8 PLF <br />2.1.6. UNIT WEIGHT OF 2x6 BEARING WALLS: <br />12 PLF <br />2.1.7. 2ND FLOOR SELF WEIGHT: <br />8 PSF <br />2.1.8. 2ND FLOOR SUPERIMPOSED LOAD: <br />20 PSF <br />2.1.9. ROOF SELF WEIGHT: <br />20 PSF <br />2.1.10, ROOF SUPERIMPOSED LOAD: <br />20 PSF <br />2.1.11, FLOOR TRUSS <br />TOP CHORD MINIMUM <br />25 PSF <br />BOTTOM CHORD MINIMUM <br />5 PSF <br />2 1 12 ROOF TRUSS <br />15 PSF <br />TOP CHORD MINIMUM <br />10 PSF <br />BOTTOM CHORD MINIMUM <br />2, <br />2. <br />LIVE LOADS: <br />2.2.1. SIDEWALK AND DRIVEWAY LOAD: <br />200 PSF <br />2.2.2. GARAGE LOADS : <br />50 PSF <br />2.2.3. CORRIDORS AND BATHROOMS: <br />100 PSF <br />2.2.4. PARTITIONED ROOMS: <br />100 PSF <br />2.2. 5. BALCONY AND DECKS: <br />60 PSF <br />2.2. 6. STAIRWAYS AND LANDINGS: <br />100 PSF <br />2.2.7. ROOF: <br />30 PSF <br />2. <br />4. <br />WIND LOADS: <br />2.4.1. WIND DESIGN TO BE CONDUCTED IN ACCORDANCE ASCE 7-10 <br />AND CONDUCTED BASED ON A 3 SECOND 150 MPH WIND GUST. <br />2, <br />S. <br />THERMAL FORCES: <br />2.5.1. SEASONAL VARIATION FOR DESIGN AND CONSTRUCTION: <br />MEDIAN TEMPERATURE: 70 F <br />TEMPERATURE RISE: 25 F <br />TEMPERATURE FALL: 35 F <br />MEDIAN RELATIVE HUMIDITY: <br />2.5.2. 75% <br />2, <br />6, <br />CREEP AND SHRINKAGE: <br />2.6.1. ALL LOSSES IN ACCORDANCE WITH ACI 318, LATEST EDITION <br />2.7. <br />SEISMIC LOADS: <br />2.7.1. SEISMIC PERFORMANCE CATEGORY "A" <br />2. <br />8, <br />DESIGN WIND SPEEDS: <br />2.8.1. COMPONENTS AND CLADDING NET PRESSURE COEFFICIENTS ARE IN ACCORDANCE WITH TABLE 1609.6.2 (1) AND TABLE <br />1609.6.2 (2). <br />2.8.2. GARAGE DOOR AND ROLLING DOOR WIND LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN <br />EXPOSURE B, TABLE 1609.7 (1). <br />2.8.3. ADJUSTMENT FACTOR FOR BUILDING HEIGHT AND EXPOSURE, TABLE 1609.7 (2). <br />COMPONENTS AND CLADDING DESIGN WIND PRESSURES ROOF OVERHANG NET DESIGN PRESSURE <br />Wind Speed 150mph 3 second gust <br />Exposure Category = B <br />Mean Reoccurrence Interval 700 Years <br />Category II - Mean Roof Height 30ft. <br />Internal Pressure Coefficient (GCpi) = t.18 (Enclosed Structure) <br />Minus signs signify pressures acting away from building surfaces <br />Sloped Roof > 7 to 27 degrees <br />ROOF ZONE <br />Wind Area (Sq. ft.) <br />10 20 <br />23.3 -37.0 21.3 <br />23.3 -64.5 21.3 <br />-36.0 <br />-59.3 <br />50 <br />18.5 -34.6 <br />18.5 -52.5 <br />100 <br />16.5 -33.6 <br />16.5 -47.3 <br />1 <br />2 <br />3 <br />23.3 -95.4 21.3 <br />10 20 <br />40.5 -43.9 38.7 -42.1 <br />40.5 -54.2 38.7 -50.5 <br />-89.2 <br />50 <br />36.2 <br />36.2 <br />18.5 -81.0 <br />100 <br />-39.7 34.4 -37.8 <br />45.7 34.4 -42.1 <br />16.5 -74.8 <br />500 <br />30.2 -33.6 <br />30.2 -33.6 <br />WALL ZONE <br />4 <br />5 <br />Envelope Procedure, the net wind load is calculated using the following equation: <br />P = gh[(GCpf) - (GCpi)] <br />Enclosure Classification <br />(GCpi) <br />Open Buildings <br />0.00 <br />Partially Enclosed Buildings <br />+0.55 -0.55 <br />Enclosed Buildings <br />+0.18 -0.18 <br />3,.,____,__D_ES1GN METHOD <br />3. 1 a LOAD FACTOR DESIGN <br />3. 1. 1. THE LOAD FACTOR DESIGN METHOD WAS USED TO DESIGN: <br />CAST -IN -PLACE CONCRETE SLABS, BEAMS, COLUMNS & FOOTINGS <br />3, 2, SERVICE LOAD DESIGN: <br />3.2.1. THE SERVICE LOAD DESIGN METHOD WAS USED TO DESIGN: <br />MASONRY WALLS AND LINTELS <br />INTERIOR AND EXTERIOR WOOD FRAMING AND SHEATHING <br />STAIRS AND FLOOR FRAMING <br />ROOF FRAMING, SHEATHING AND UP LIFT <br />3. 3. LOAD FACTORS AND COMBINATIONS <br />3.3.1. THE FOLLOWING LOAD COMBINATIONS WERE DESIGNED FOR: <br />TOTAL DL + FLOOR LL + ROOF LL <br />TOTAL DL + FLOOR LL + WL <br />TOTAL DL + WL <br />IN THE CASE OF WIND LOADS, AN ALLOWABLE OVER STRESS OF 125% CAN BE CONSIDERED. <br />3.3.2. ALL ROOF AND FLOOR TRUSSES SHALL BE DESIGNED TO RESIST THE WORST LOAD COMBINATION RESULTING IN THE <br />MAXIMUM STRESSES PLACED ON <br />THAT COMPONENT. BOTH PARTIAL, FULL, AND ALTERNATING SPAN LOADING ARE TO BE CONSIDERED. <br />3.3.3. <br />3. 4. DESIGN ASSUMPTIONS: <br />3.4.1. FOUNDATIONS ARE DESIGNED BASED ON A PRESUMPTIVE BEARING CAPACITY OF 2500 PSF ON UNDISTURBED SOIL OR ROCK. <br />A REGISTERED <br />GEOTECHNICAL ENGINEER SHALL VERIFY ACTUAL CONDITIONS PRIOR TO PLACEMENT OF THE FOOTING, IF THE FOUNDATION <br />IS ON PREPARED FILL, THE <br />REGISTERED GEOTECHNICAL ENGINEER SHALL VERIFY SUITABILITY OF FILL FOR USE AND ITS FOUNDATION BEARING <br />CAPACITY. <br />3.4.2. ALL FOUNDATIONS ARE CENTERED UNDER SUPPORTED COLUMNS AND WALLS UNLESS SHOWN OTHERWISE IN THE DESIGN <br />PLANS. <br />4. MATERIALS_- <br />4, 1, REINFORCING STEEL: <br />4.1.1. REINFORCING STEEL SHALL BE ASTM A615 GRADE 60, fy = 40 Ksi UNLESS OTHERWISE NOTED. <br />REINFORCING LAP SPLICES SHALL BE 48 BAR DIAMETERS IN LENGTH UNLESS OTHERWISE NOTED. <br />ALL DIMENSIONS PERTAINING TO THE LOCATION OF REINFORCING ARE TO THE CENTERLINE OF EACH BAR EXCEPT WHERE <br />4.1.2. THE COVER DIMENSION IS <br />SHOWN TO THE FACE OF THE CONCRETE. <br />REINFORCING DETAIL DIMENSIONS ARE OUT TO OUT OF BARS. <br />4. 1. 3. REINFORCING MECHANICAL COUPLERS ARE TO DEVELOP 125 % OF THE REQUIRED YIELD STRENGTH OF THE BAR AND ARE <br />TO BE APPROVED BY THE <br />ENGINEER OF RECORD. <br />DESIGN COVER REQUIREMENTS: <br />4.1.4. C-1-P CONCRETE FORMED AGAINST EARTH: 3" <br />C-1-P CONCRETE EXPOSED TO EXTERIOR: 2" <br />4.1.5. C-1-P CONCRETE NOT EXPOSED: 1 1/2" <br />GROUT FILLED MASONRY: 3/4" <br />PRE STRESSED CONCRETE LINTELS: 1 1/2" <br />PRE CAST GROUT FILLED LINTELS: 1 1/2" <br />4a 3, STRUCTURAL LUMBER: <br />4.4. 1. <br />MAXIMUM DESIGN VALUES <br />MODULUS OF <br />BENDING TENSION SHEAR <br />ELASTICITY <br />f b f t fw <br />E) <br />INTERIOR FRAMING 2x(4) 1,500 Psi 825 Psi 90 Psi <br />1,600 Ksi <br />EXTERIOR FRAMING 2x(6 AND 8) 1,200 Psi 650 Psi 90 Psi <br />1,600 Ksi <br />FLOOR FRAMING 2x(8 AND 10) 1,300 Psi 725 Psi 90 Psi <br />1,700 Ksi <br />TABLE VALUES ARE MINIMUMS AND ARE BASED ON SOUTHERN PINE No. 2 GRADE. <br />4.4.2. <br />ALL PLYWOOD USED FOR EXTERIOR APPLICATIONS SHALL CONFORM TO VOLUNTARY <br />PRODUCT STANDARD PS 1-83 AND SHALL BE APA RATED SHEATHING EXP 3. <br />4.4.3. <br />ALL PLYWOOD USED FOR INTERIOR APPLICATIONS SUCH AS SUB FLOORING AND SHEAR <br />WALLS SHALL CONFORM TO VOLUNTARY PRODUCT STANDARD PS 1-83 AND SHALL BE APA <br />RATED SHEATHING EXP 1 OR 2. <br />4.4.4. <br />IF OSB BOARD IS TO BE USED IN PLACE OF PLYWOOD IS TO HAVE SIMILAR SECTION <br />PROPERTIES. <br />4.4.5. <br />ONLY STRUCTURAL LUMBER TO BE USED FOR AN EXTERIOR APPLICATION AND IN CONTACT <br />WITH CONCRETE IS TO RECEIVE A STANDARD GRADE PRESSURE TREATING. <br />4.4.6. <br />PRESSURE TREATED STRUCTURAL LUMBER IS NOT TO BE USED FOR ANY INTERIOR <br />FRAMING. <br />4.4. FASTENERS AND TIE DOWNS : <br />4.5.1. <br />FASTENERS AND TIE DOWNS SHALL CONSIST OF BUT ARE NOT LIMITED TO: <br />SHAPES, ANGLES, CHANNELS : ASTM A36 Fy = 36 Ksi <br />ROUND METAL PIPE: ASTM A53, GRADE B Fy = 35 Ksi <br />SQUARE METAL TUBING: ASTM A500, GRADE B Fy = 46Ksi <br />HIGH STRENGTH BOLTS: ASTM A325 <br />MACHINE BOLTS: GALVANIZED ASTM A307 <br />4.5.2. <br />SHEET METAL ACCESSORIES SHALL CONFORM TO: ASTM A446 OR ASTM A526 Fy = 33 <br />Ksi WITH G90 GALVANIZED COATING IN ACCORDANCE WITH ASTM A525. <br />4.5.3. <br />NAILS SHALL CONSIST OF: COMMON WIRE NAILS WITH MINIMUM DIAMETER AS FOLLOWS <br />8d = 0.131 ", 10d = 0.148", 16d = 0.162". <br />4.5.4. <br />ALL FASTENERS AND TIE DOWNS EMBEDDED IN CONCRETE OR USED IN AN EXTERIOR <br />APPLICATION ARE TO RECEIVE AN ANTI -CORROSIVE COATING PRIOR TO <br />INSTALLATION. <br />4.5.5. <br />ALL FASTENERS AND TIE DOWNS ARE TO PROVIDE THE UPLIFT CAPACITY CALLED <br />FOR IN THE PLANS ASAMINIMUM. <br />4.5.6. <br />CONCRETE EMBEDDEWS BOLTS USED FOR UPLIFT ARE TO BE WET SET PRIOR TO <br />INITIAL SET OF THE CONCRETE, SPACING AND ALIGNMENT ARE TO BE IN ACCORDANCE <br />WITH THE DESIGN PLANS. <br />R <br />A <br />90%%D HOOK SHOWN <br />STANDARD HOOK FOR <br />REINFORCING BAR <br />L MIN. LAP <br />LAP SPLICE <br />RECOMMENDED <br />END <br />HOOKS <br />90%%D HOOK <br />AND LAP LENGTHS <br />HOOK <br />BAR <br />180%%D HOOK <br />LAP <br />A <br />R <br />V. <br />SIZE <br />A <br />5" <br />Lb <br />18" <br />#3 <br />6" <br />#4 <br />6" <br />8" <br />1-1/2" <br />24" <br />#5 <br />7" <br />10" <br />2" <br />30" <br />#6 <br />8" <br />12" <br />2-1/4" <br />36" <br />#7 <br />10" <br />14" <br />2.1 /2" <br />42" <br />#8 <br />11" <br />16" <br />3" <br />48" <br />#9 <br />15" <br />19" <br />4-3/4" <br />55" <br />#10 <br />17" <br />22" <br />5-1/2" <br />61" <br />UPDATED 11/02/2020 ^ <br />BUILDING RISK CATEGORY: I I_ <br />BASIS OF DESIGN WIND SPEED MPH - 31SECOND.-GUST 150 <br />EXPOSURE CATEGORY (A, B, OR C): "Bel <br />WINDBORNE DEBRIS REGION REQUIREMENTS: YES --- <br />A, PLYWOOD SHUTTERS NIA ---- <br />B. SAFETY GLASS YES - <br />C. ROLL DOWN SHUTTERS NIA <br />D. OPEN DESIGN .NIA <br />INTERNAL PRESSURE COEFFICIENT: - fl.__0t1 <br />1. VALLEY LININGS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURES INSTALLATION. <br />INTSRUCTIONS BEFORE APPLYING CONC. ROOF TILES VALLEY LININGS OF THE FOLLOWING <br />TYPES SHALL BE PERMITTED. <br />2. FOR OPEN VALLEYS (VALLEY LINING EXPOSED) LINED WITH METAL, THE VALLEY LINING <br />SHALL BE AT LEAST 16 INCHES (406 MM) WIDE AND OF ANY OF THE <br />CORROSION -RESISTANT METALS. <br />3. FOR OPEN VALLEYS (VALLEY LINING IF TWO PILES OF MINERAL SURFACES ROLL ROOFING <br />SHALL BE PERMITTED. THE BOTTOM LAYER SHALL BE 18 INCHES (457 MM) AND THE TOP <br />LAYER A MINIMUM OF 36 INCHES (914 MM) WIDE. <br />4, FOR CLOSED VALLEYS (VALLEY COVERED WITH SHINGLES), VALLEY LININGS SHALL <br />BE ONE OF THE FOLLOWING: <br />A. BOTH TYPES 1 AND 2 ABOVE COMBINED <br />B. ONE PLY OF SMOOTH ROLL ROOFING AT LEAST 36 INCHES WIDE (914 MM) AND <br />COMPLYING WITH ASTM D 224. <br />C. SPECIALITY UNDERLAYMENT AT LEAST 36 INCHES (914 MM) WIDE AND <br />COMPLYING WITH ASTM D 1470. <br />WINDOWS__AND-QOOR.Si ._.. <br />1. EXTERIOR WINDOWS AND GLASS DOORS SHALL BE TESTED PRIOR TO INSTALLATION IN <br />ACCORDANCE WITH ANSI/AMMAINWDA 101 I IS2 STANDARD AND BEAR AN AMMA OR WDMA <br />LABEL IDENTIFYING THE MANUFACTURER, PERFORMANCE CHARACTERISTICS AND APPROVED <br />PRODUCT TESTING ENTITY, IN ACCORDANCE WITH CHAPTER 17 OF THE FLORIDA BUILDING <br />CODE. <br />2. ALL DOORS & WINDOWS SHALL COMPLY WITH F.B.C. WIND LOAD <br />REQUIREMENT -150 MPH <br />3. ALL GLASS DOORS TO BE TEMPERED GLAZING. <br />4. ANY GLAZING WITHIN 36" HORIZONTALLY AND BELOW 60" OF THE STANDING <br />SURFACE OF A BATHTUB, SHOWER, SPA, ETC., SHALL BE SAFETY GLAZED. <br />5. PERIMETER EXTERIOR SEALANT TO BE DOW 795 SILICONE SEALANT OR APPROVED EQUAL; <br />VERIFY COMPATIBILTIY OF SEALANT WIHT ADJACENT SUBSTRATES PRIOR TO INSTALLATION <br />6. ALL DOORS AND WINDOW TO FBC NOA COMPLIANT FOR WIND LOAD INDICATED. <br />FASTNER SPACING AND SIZE SHALL BE IN ACCORDANCE WITH THE MFG: S FBC APPROVED NOA. <br />7. WINDOW AND DOOR FRAMES SHALL BE PAINTED WITH PPG KYNAR PAINT SYSTEM COMPLYING WITH <br />AAMA 2605, OR APPROVED EQUAL. COLOR TO BE BONE WHITE OR BY OWNER. <br />WINDOW- ANCHORAGE REQUIREMENTS: <br />1. EXTERIOR WINDOWS AND DOORS - WHERE BUCK THICKNESS IS 1-1/2 INCHES OR LESS, THE <br />- BUCK SHALL BE ATTACHED WITH FASTENERS THROUGH TO JAMB AND SECURED DIRECTLY <br />TO THE STRUCTURE; MINIMUM EMBEDMENT INTO STRUCTURE IS 1-3/4", OR AS REQUIRED BY <br />MFG.'S FBC APPROVED NOA CRITERIA FOR THE WIND LOADS INDICATED AND AS REQUIRED <br />BY LOCAL BUILDING CODES. <br />STEEL LAP AND- BEND DTLN_ <br />NTS <br />LINTEL TYPE - A <br />SPAN T-0" <br />THRU 6-0" <br />LINTEL TYPE - B <br />SPAN 6'-0" <br />THRU 18'-0" <br />- LINE OF - <br />REINF. <br />STL <br />4" MIN BEARING <br />LINTEL SCHEDULE <br />LINTEL TYPE <br />TYPE - A <br />TYPE -B <br />BAR SIZE BAR QNTY• LINTEL SIZE <br /># 5 2 8" x 8" <br /># 5 4 8" x 16" <br />8" MIN BEARING <br />LINTEL SCHEDULE & REINF, <br />NTS <br />GENERAL NOTES--------- <br />1. CONSTRUCTION SHALL COMPLY WITH ALL LOCAL BULIDING CODES. <br />4■ 2. CONCRETE : 2. PRE -ENGINEERING ROOF TRUSSES SHALL BE DESIGNED TO MEET 150 MPH <br />WIND UPLIFT CRITERIA BY A FLORIDA REGISTERED ENGINEER. <br />4.2. 1. C-I-P CONCRETE <br />C-I-P GROUT <br />PRE CAST CONCRETE LINTELS <br />PRE STRESSED CONCRETE LINTELS <br />3. CONCRETE SHALL REACH DESIGN STRENGTH WITHIN 28 DAYS OF <br />PLACEMENT. SLAB ON GRADE CONCRETE SHALL BE CHEMICALLY CURED <br />WITH MATERIAL COMPATIBLE WITH FLOORING ADHESIVE. <br />4, ALL STRUCTURAL LUMBER SHALL BE NO. 1 - SOUTHERN YELLOW PINE KILN <br />DRIED. ALL WD. IN CONTACT WITH CONC. SHALL BE TREATED WITH WOOD <br />PRESERVATIVE, ALL DIMENSIONAL LUMBER EXPOSED TO WEATHER SHALL <br />BE PRESSURE TREATED. <br />4.2. 2. CONCRETE SHALL CONSIST OF 1" MAXIMUM AGGREGATE CONCRETE MIX WITH SLUMP BETWEEN 6" AND 7" AT TIME OF PLACEMENT. SEE ACI 5. <br />SPECIFICATIONS FOR ADDITIONAL CRITERIA. <br />4.2.3. GROUT SHALL CONSIST OF PEA ROCK (318" MAXIMUM AGGREGATE) CONCRETE MIX WITH SLUMP BETWEEN Be AND 10" AT TIME OF PLACEMENT. SEE ACI, <br />ASTM SPECIFICATIONS FOR ADDITIONAL CRITERIA. <br />6. <br />4.2.4. CONSTRUCTION JOINTS ARE TO BE PROVIDED IN ACCORDANCE WITH THE DESIGN CODES AND GUIDELINES AT THE ENGINEERS DIRECTION. <br />4.2.5. METHOD OF CONCRETE FORMING, PLACEMENTAND CURING SHALL BE CONDUCTED IN ACCORDANCE WITH THE ACI, ASTM SPECIFICATIONS AS STATED, <br />MODULUS OF <br />MIN. 28 DAY <br />ELASTICITY <br />DESIGN (fc) <br />DESIGN (E) <br />3,000 Psi <br />3,122 Ksi <br />2,000 Psi <br />2,500 Ksi <br />3,000 Psi <br />4,000 Ksi <br />5,000 Psi <br />3,200 Ksi <br />ROOF DECKING SHALL BE INSTALLED IN T & G CONFIGURATION & SHALL <br />BE NAILED @ 6" O.C. @ EDGES & 12" O.C, INTERMEDIATE AREA NAILS SHALL <br />BE 10d COMMON DEFORMED SHANK. PERIMETER EDGE FLASHING SHALL BE <br />PAINTED GALV. 20 GA MTL. MIN. LAP @ ROOF SHALL BE 3" - NAILED @ 6" O.C. <br />& SET IN MASTIC. <br />DECK DESIGNS TO COMPLY WITH FBC, SECTION R502, WOOD FLOOR FRAMING, <br />R502.1.4 DECKS: <br />WHERE SUPPORTED BYATTACHMENT TO AN EXTERIOR WALL, DECKS SHALL BE POSITIVELY ANCHORED TO THE PRIMARY <br />STRUCTURE AND DESIGNED FOR <br />BOTH VERTICAL AND LATERAL LOADS AS APPLICABLE. SUCH ATTACHMENT SHALL NOT BE ACCOMPLISHED BY THE USE OF <br />TOENAILS OR NAILS SUBJECT TO <br />WITHDRAWAL. <br />TYPE OF ROOF SYSTEM: <br />NOT APPLICABLE TO THIS PROJECT <br />TERMITE PROTECTION TO COMPLY <br />WITH FBC,_ SECTION_ 1816_ <br />1. A WEATHER RESISTANT JOB SITE POSTING BOARD SHALL BE PROVIDED TO RECEIVE <br />DUPLICATE TREATMENT CERTIFICATES TO BE POSTED AFTER EACH REQUIRED PROTECTIVE <br />TREATMENT IS COMPLETED, A COPY OF THE CERTIFICATE IS TO BE PROVIDED FOR THE <br />PERSON THE PERMIT IS ISSUED TO, AND ANOTHER COPY FOR THE BUILDING PERMIT FILES. <br />2. TO ESTABLISH A VERIFIABLE RECORD OF PROTECTIVE TREATMENT, THE TERMITE <br />CERTIFICATE SHALL 1) INDICATE THE PRODUCT USED, 2) IDENTITY OF THE APPLICATOR, 3) <br />TIME AND DATE OF THE TREATMENT, 4) SITE LOCATION, 5) AREA TREATED, 6) CHEMICAL <br />USED, AND 7) PERCENT CONCENTRATION AND NUMBER OF GALLONS USED. <br />3. IF THE SOIL CHEMICAL BARRIER METHOD FOR TERMITE PREVENTION IS USED, FINAL <br />EXTERIOR TREATMENT SHALL BE COMPLETED PRIOR TO FINAL BUILDING APPROVAL. <br />4. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR <br />RE -INSPECTION AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE SIGN <br />SHALL BE POSTED NEAR THE WATER HEATER OR ELECTRIC PANEL. <br />5. INITIAL TERMITE CHEMICAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND <br />BACKFILL IS COMPLETE. <br />6. SOIL DISTURBED AFTER THE INITIAL TERMITE CHEMICAL TREATMENT SHALL BE <br />RETREATED INCLUDING SPACES BOXED OR FORMED. BOXED AREAS IN CONCRETE <br />FLOORS FOR SUBSEQUENT INSTALLATION OF TRAPS, ETC., SHALL BE MADE WITH PERMANENT <br />METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF A SIZE AND DEPTH THAT WILL <br />ELIMINATE THE DISTURBANCE OF SOIL AFTER THE INITIAL TREATMENT. <br />7. ALL VAPOR BARRIER JOINTS MUST BE TAPED, CONTINUOUS WITH DUCT TAPE, AND VAPOR <br />BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL DILUTION. IF RAINFALL <br />OCCURS BEFORE VAPOR BARRIER PLACEMENT, RE -TREATMENT IS REQUIRED. <br />8. CONCRETE OVERPOUR AND MORTAR ALONG THE FOUNDATION PERIMETER MUST BE <br />REMOVED BEFORE EXTERIOR SOIL TERMITE CHEMICAL TREATMENT IS APPLIED. TERMITE <br />CHEMICAL SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR <br />GRADE WITHIN V-0" OF THE STRUCTURE SIDEWALLS. <br />9. AN EXTERIOR VERTICAL TERMITE CHEMICAL BARRIER MUST BE INSTALLED AFTER <br />CONSTRUCTION IS COMPLETE INCLUDING LANDSCAPING AND IRRIGATION. ANY SOIL <br />DISTURBED AFTER THE VERTICAL BARRIER IS APPLIED, SHALL BE RETREATED. <br />10. ALL BUILDINGS ARE REQUIRED TO HAVE PRE -CONSTRUCTION TERMITE CHEMICAL <br />TREATMENT. <br />11. A CERTIFICATE OF COMPLIANCE MUST BE PREPARED BY A LICENSED TERMITE <br />TREATMENT APPLICATOR AND IS TO BE ISSUED TO THE BUILDING DEPARTMENT BEFORE A <br />CERTIFICATE OF OCCUPANCY WILL BE ISSUED. <br />THE CERTIFICATE OF COMPLIANCE SHALL STATE, "THE BUILDING HAS RECEIVED A <br />COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. THE TREATMENT <br />IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA DEPARTMENT OF <br />AGRICULTURE AND CONSUMER SERVICES." <br />12. AFTER ALL WORK IS COMPLETED, LOOSE WOOD AND FILL MUST BE REMOVED FROM <br />BELOW AND WITHIN V-0" OF THE BUILDING. THIS INCLUDES ALL GRADE STAKES, TUB TRAP <br />BOXES, FORMS, SHORING OR OTHER CELLULOSE CONTAINING MATERIAL. <br />13. NO WOOD VEGETATION STUMPS, CARDBOARD, TRASH, ETC., SHALL BE BURIED WITHIN <br />15-0" OF THE BUILDING. <br />14. CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST V-0" AWAY FROM <br />THE BUILDING SIDEWALLS, OR PRECAST SPLASH BLOCKS MUST BE INSTALLED AS <br />INDICATED ON THE CONTRACRT DOCUMENTS. <br />15, IRRIGATION/SPRINKLER SYSTEMS INCLUDING ALL RISERS AND SPRAY HEADS SHALL NOT <br />BE INSTALLED WITHIN V-0" OFTHE BUILDING SIDEWALLS. <br />1 <br />U0 <br />ttampa <br />URSAMoRDER"tampa, Inc. <br />5006 south elberon street 33611 <br />813.832.5557 <br />as2002460 <br />URBANoRDER.tam a inc. <br />The« pans are copyrighted and are WW to <br />copyright protection as an `arcNtsctural work" under <br />section 102 of the oopyright act. 17 u.s.o. as <br />amended December 1990 and known as architectural <br />wake copyright protection 0 of 1990. The <br />protection inctudw but 4 not limited to the mall <br />form se wee as anangemant end aanposition of <br />spaces and elements of the design, under each <br />prolec5on, unautha¢ed use of mace plans, work or <br />home represented, man l gelry result in the oeacation <br />of coneauctlon or bulW <br />ompeasairgs being seized andior <br />monetary ciem to URBANaRDE.Rltampa inc., <br />Florida registration AA2M460. <br />ISSUE DATE <br />05/15/2019 <br />REVISIONS <br />n <br />LO <br />CM <br />M <br />U <br />z <br />W <br />O <br />U <br />U_ <br />Q` <br />_CU <br />U) <br />/ <br />W <br />:mE <br />CL <br />N <br />N <br />W <br />H <br />O <br />z <br />J <br />1-- <br />V <br />H <br />JOETOPH. <br />FL.,REG.AR10095 <br />DATE: 11/1912020 <br />DRWN, <br />CHKDI <br />SCALE: <br />DISCLAIMER <br />THE CLIENT UNDERSTANDS THAT THERE IS NO LIABILITY INSURANCE THAT CAN BE CLAIMED PER THIS PROJECT AND AGREES <br />TO HOLD HARMLESS, INDEMNIFY, AND DEFEND THE ARCHITECT FROM ALL CLAIMS, LOSSES AND EXPENSES, INCLUDING <br />REASONABLE ATTORNEY FEES ARISING OUT OF OR RESULTING FROM THE DRAWINGS. IN THE EVENT ERRORS OCCUR, THE <br />ARCHITECT WILL NOT BE LIABLE FOR COST OF REPAIRS OR DELAY TO THE CONSTRUCTION FOR THIS PROJECT. <br />SHEETNUMBER <br />A=25 <br />