UPDATED 11/02/2020
<br />WAT
<br />MEM
<br />INST
<br />DOW
<br />FACE
<br />1/2"
<br />BELC
<br />PERMA-TITE SPLICE PLATE
<br />NOT SHOWN FOR CLARITY
<br />PERMA-TITE GALV.
<br />ANCHOR CLIPS 4'-0" O.C.
<br />STAINLESS STEEL
<br />FASTENERS PROVIDED
<br />BY JOHNS MANVILLE
<br />PERMA-TITE METAL
<br />COPING COVER
<br />DYNAFLEX CAP SHEET
<br />3/8" (10 mm) GAP
<br />FOR WALL VARIATIONS
<br />JM MODIFIED BITUMEN
<br />BASE SHEET
<br />NOTES:
<br />1. REFER TO JOHNS MANVILLE WEBSITE (www.jm.com) FOR MOST UP-TO-DATE INFORMATION.
<br />2. INSTALL PERMA-TITE COPING IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS INCLUDED WITH THE PRODUCT.
<br />PREFABRICATED INSIDE/OUTSIDE CORNERS AND END CAPS ARE AVAILABLE TO COMPLETE THE INSTALLATION.
<br />SHOP FABRICATED COPINGS SHOULD BE INSTALLED IN ACCORDANCE WITH SMACNA GUIDELINES.
<br />3. VERTICAL JOINTS ARE TO BE OVERLAPPED 4" MINIMUM FOR ALL APPLICATIONS. 3 COURSING WITH MBR UTILITY
<br />CEMENT AND FABRIC OR JM MBR FLASHING CEMENT IS RECOMMENDED ON ALL VERTICAL FLASHING LAPS AND
<br />INSIDE/OUTSIDE CORNERS EXTENDING PAST LEADING EDGE OF CANT STRIP.
<br />4. ANY CARPENTRY, METAL WORK, OR MASONRY CONSTRUCTION SHOULD BE DESIGNED AND CONSTRUCTED IN
<br />ACCORDANCE WITH LOCAL CODE REQUIREMENTS AND/OR PROJECT SPECIFICATIONS. THESE COMPONENTS
<br />SHOULD BE REVIEWED AND APPROVED BY A LICENSED DESIGN PROFESSIONAL. CONTACT JM TECHNICAL FOR
<br />METAL OPTIONS TO BE INCLUDED WITHIN THE JM NDL GUARANTEE.
<br />S. PLEASE SEE BITUMINOUS FLASHING SPECIFICATIONS FOR A FULL DESCRIPTION OF INSTALLATION
<br />INSTRUCTIONS AND REQUIREMENTS WHICH ARE CONSIDERED A PART OF THIS DETAIL.
<br />DRAWING NO. PERMA-TITE COPING SYSTEM OVER MOD. BIT.
<br />FE-2 (PT) MEMBRANE TYPE:Johns Menklw 4 a manufacture of wrarsrCW 100" prods and a1Mc this general wncepbnN
<br />FLASHING WALL JM BUR anlormation to you as a courtesy. This complimentary assstance is not to be used or rallied upon by
<br />sftyone a a subdi for rokxional arnpineerag deep and doeumenblbn required by Dui d ng p u
<br />SCALE ISSUE DATE MAXIMUM GUARANTEE TERM. woe wnrabl, or endorsements
<br />By an saayg Nose cur ohnit you eyNM hey ate not awy IN a ee re t any
<br />N.T.S 02-06-19 20 YEAR r usq d ft dngnn of tfir oubd" a raw"pon� girls nor sWpeed by Manville of any NI NAS NIawN the
<br />DE
<br />yl� f
<br />O fL 5cU R
<br />CTIO (SEE 110 �ER';�:j
<br />iAC
<br />TOP HEM FILLED
<br />WITH CAULK,
<br />SEAL ALL SIDES
<br />GALVANIZED METAL
<br />FACE PLATE INSTALLED
<br />OVER SCUPPER SLEEVE
<br />PINNED & SEALED TO
<br />EXTERIOR WALL
<br />V
<br />a~
<br />y/
<br />/FACEPLATE
<br />l9
<br />ON
<br />TERMINATE TOP OF
<br />EXTERIOR WALL
<br />BASE FLASHINGS
<br />N
<br />AS SPECIFIED
<br />of g
<br />z aL
<br />SMOOTH SBS TARGET
<br />PATCH BEHIND
<br />oo
<br />SCUPPER
<br />ADHERED
<br />k k
<br />�k
<br />ak
<br />�p1,6
<br />n
<br />DXNYI�LEX "0•
<br />OVRk
<br />k(EXTEND
<br />ONRl(
<br />ere" ' o
<br />SC.UPPEO
<br />BIAS
<br />a
<br />SCUPPER SLEEVE
<br />THROUGH WALL
<br />ASPHALT PRIMER
<br />JM FESCANT PLUS
<br />C�J
<br />3 COURSE ALL
<br />EDGES OF OUTER
<br />:FLASHING AT SCUPPER
<br />W/ MBR UTILITY CEMENT
<br />SUMP CORNER
<br />g MITERED TAPERED
<br />EDGE STRIPS
<br />UNDER MEMBRANE
<br />SET FLANGE INTO BED
<br />OF MBR UTILITY CEMENT
<br />NAIL FLANGE OF SCUPPER
<br />r� THROUGH BASE FLASHING
<br />FF 10 AND ALL PLIES OF ROOF
<br />rC Sc0 �`,a. INTO WOOD NAILER BELOW
<br />� ' • OL4 sloe �o WITH RING SHANK NAILS
<br />F
<br />eOq O Ty7CSrRla
<br />WOOD NAILER SECURED TO, �O V 4iyFSSj c�+
<br />DECK UNDER SCUPPER FLANGE.
<br />(SHOWN OUTSIDE OF
<br />NOTES: SUMP FOR CLARITY) C k 1. ADHESIVE NOT SHOWN UNDER PLIES FOR CLARITY.
<br />2. PRIME ALL SCUPPER FLANGES ON BOTH SIDES WITH ASPHALT PRIMER.
<br />3. ALL SCUPPER FLANGES SHALL BE 4" WIDE. PLEASE REFER TO LOCAL CODES AND
<br />SMACNA FOR METAL SCUPPER AND CONDUCTOR HEAD FABRICATION REQUIREMENTS.
<br />4. REFER TO JOHNS MANVILLE WEBSITE (www.jm.com) FOR MOST UP-TO-DATE INFORMATION.
<br />5. SCUPPER FACEPLATE ON EXTERIOR SHOWN AS AN EXAMPLE.
<br />6. ANY CARPENTRY, METAL WORK, OR MASONRY CONSTRUCTION SHOULD BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH
<br />LOCAL CODE REQUIREMENTS AND/OR PROJECT SPECIFICATIONS. THESE COMPONENTS SHOULD BE REVIEWED AND APPROVED
<br />BY A LICENSED DESIGN PROFESSIONAL.
<br />7. PLEASE SEE BITUMINOUS FLASHING SPECIFICATIONS FOR A FULL DESCRIPTION OF INSTALLATION
<br />INSTRUCTIONS AND REQUIREMENTS WHICH ARE CONSIDERED A PART OF THIS DETAIL.
<br />DRAWING NO. PRIMARY METAL SCUPPER IN SUMP
<br />DF E -21 MEMBRANE TYPE: John! Mama is a matwfacturerd cotnherctal mafmg product and dNta lhiir genera wneep0ual
<br />DRAINS & VENTS BUR edomweloo to you a a wunny The complementary assistance s not to be used a -tact lgon by
<br />anyone a a substl iss ra Iessional eNIneerlg design and documentation required by building
<br />pro ens ate nor crostade
<br />SCALE ISSUE DATE MAXIMUM GUARANTEE TERM cetle contract `;r dWD cmle owA`a`:7bgff feae cann ya apd Ndi ry a il
<br />N.T.S 612-14 adequagdffedesignorteb er, aft material nts ru by pJya lU.11ryr,,.or joh1/Aft"19
<br />N
<br />UNDERDECK DRAIN
<br />CLAMP (AS REQUIRED)
<br />SHEET LEAD, MIN. 30" X 30"
<br />PRIME LEAD WITH PRIMER ON
<br />BOTH SIDES, (SEE NOTES)
<br />ROLL LEAD DOWN BOWL. (SET
<br />IN MBR UTILITY CEMENT OR
<br />MBR FLASHING CEMENT)
<br />✓�C
<br />C"9.o
<br />sy
<br />SFr
<br />DRAIN STRAI
<br />SUMP CORNER
<br />CLAMPING RING
<br />CAP SHEET UNDER
<br />CLAMPING RING
<br />/ JM CLEANSOND SA/SA BASE
<br />JM CLEANBOND SA/SA BASE
<br />BELOW CAP SHEET
<br />LEAD SHEET
<br />INSULATION TAPERED JM TO DRAIN Ao Rlgj�
<br />RdV ►vS��Tr
<br />NOTES:
<br />1. REFER TO JOHNS MANVILLE WEBSITE (www.jm.com) FOR MOST UP-TO-DATE INFORMATION.
<br />2. ASPHALT AND MBR UTILITY CEMENT NOT SHOWN FOR CLARITY
<br />3. LEAD FLASHING SHALL BE 2.5 LBS. PER SQUARE FOOT MINIMUM.
<br />4. IT IS ACCEPTABLE TO RUN FIELD MEMBRANE PLY THROUGH DRAIN CENTER AND OMIT TARGET SHEET IF DRAIN SUMP IS SHALLOW
<br />ENOUGH TO ALLOW INSTALLATION WITHOUT WRINKLES OR FISHMOUTHS. STEEP SUMPS WILL REQUIRE THE INSTALLATION OF A
<br />TARGET PATCH WITHIN DRAINSUMP.
<br />5. USE ASPHALT PRIMER ON LEAD FLANGES WHEN USING MBR UTILITY CEMENT. USE PERMAFLASH PRIMER ON LEAD FLANGES WHEN
<br />USING MBR FLASHING CEMENT,
<br />6. EXTEND ALL PLIES TO EDGE OF DRAIN BOWL.
<br />7. ANY CARPENTRY, METAL WORK, OR MASONRY CONSTRUCTION SHOULD BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH
<br />LOCAL CODE REQUIREMENTS AND/OR PROJECT SPECIFICATIONS. THESE COMPONENTS SHOULD BE REVIEWED AND APPROVED BY A
<br />LICENSED DESIGN PROFESSIONAL.
<br />8. PLEASE SEE BITUMINOUS FLASHING SPECIFICATIONS FOR A FULL DESCRIPTION OF INSTALLATION INSTRUCTIONS AND REQUIREMENTS
<br />WHICH ARE CONSIDERED A PART OF THIS DETAIL.
<br />DRAWING NO.
<br />CBE-11 MEMBRANE METAL DRAIN
<br />M TYPE: ME
<br />rm MenNk is a ndacwnr commercial roof caul offers the oral Jon ma d odtsrJ
<br />n9 products fie° coupon by
<br />nfarrnalan to a a . This men assistance h not b De used a rdled You Caebl y °°nHt ay upon by
<br />DRAINS $VENTS BUR anyone a a weseanm for pdeeelorW enginaenrg Design and documentation required by building
<br />SCALE ISSUE DATE MAXIMUM GUARANTEE TERM: wds. contract a appr law By aowpli g the" canmeno you agree Nov do not constitute envy
<br />N.T.S 12-10-18 bons, emohemeNb of a an o other a Jnhru ManHu of any fp s Mianvantler Na � ,M
<br />aeprecy design a Its btiblg a any obrer meonA rat wppbea by Johns e.
<br />STEP 1
<br />FIRST, MITER CANT
<br />STRIP AT CORNER
<br />RUN ONE SHEET
<br />UP BOTH EDGES--p
<br />MITER CUT IN
<br />FIELD SHEET
<br />OVERLAP & SEAL
<br />STRIP FIELD MEMBRANE CANT
<br />XTEND SECOND
<br />IASE FLASHING
<br />CUT OVER
<br />1VER FIRST PIECE
<br />EDGE FOR
<br />IP TO EDGE
<br />CLEAN LINES
<br />FIELD MEMBRANE /
<br />STRIP CANT STRI
<br />STEP 2
<br />WRAP FIRST BASE FLASHING
<br />AROUND CORNER PROVIDING
<br />RELIEF CUTS AT CANT
<br />TRANSITIONS AND OVERLAP
<br />FLASHING AS SHOWN
<br />FIELD MEMBRANE
<br />STRIP \\\ CANT STRIP
<br />STEP 4
<br />NOTES:
<br />1. REFER TO JOHNS MANVILLE WEBSITE (www.jm.com) FOR MOST UP-TO-DATE INFORMATION.
<br />2. 3-COURSING WITH MBR UTILITY CEMENT & FABRIC OR MBR FLASHING CEMENT & FABRIC MUST BE
<br />USED ALONG EDGE OF BASE FLASHING AS DEPICTED IN STEP 4.
<br />3. VERTICAL JOINTS ARE TO BE OVERLAPPED 4" MINIMUM FOR ALL APPLICATIONS. 3 COURSING WITH MBR
<br />UTILITY CEMENT AND FABRIC OR JM MBR FLASHING CEMENT IS RECOMMENDED ON ALL VERTICAL FLASHING
<br />LAPS AND INSIDE/OUTSIDE CORNERS EXTENDING PAST LEADING EDGE OF CANT STRIP.
<br />4. PLEASE SEE BITUMINOUS FLASHING SPECIFICATIONS FOR A FULL DESCRIPTION OF INSTALLATION
<br />INSTRUCTIONS AND REQUIREMENTS WHICH ARE CONSIDERED A PART OF THIS DETAIL.
<br />DRAWING NO. BASE FLASHING AT INSIDE CORNER
<br />DE -fors//�/7 MEMBRANE TYPE: John Mamflat Is a mardardurer of commercial ercial mdang products and omas this gews! wrapWa
<br />nbrmatw to a Thh invent 9iaaras is not b be used a raped a a e
<br />CURB CORNER BUR
<br />you coutesy � ail °D°1 M
<br />U B& 0
<br />arv°ira a a sucebNo to pr°fasorel emjpleemnp desgrn and documenlabal required Dy Duldag
<br />SCALE I ISSUE DATE MAXIMUM GUARANTEE TERM �°• contract a apppw law By aweptllg fora canmenm you agree any b nd XnN lute soy
<br />N.T.S 02-08-19 represerNatrons, erudorsenisnb M. a an acsrmpron by Jahm Menaies d any ipbiliry or e1Dx Ne � �De
<br />adequacy d fe dngn of fo bulblg a dry curer matenat rid suppuea by John Marrvae.
<br />ROLL TOP OF LEAD
<br />FLASHING DOWN INTO
<br />PIPE APPROXIMATELY 1"
<br />- PLUMBING VENT STACK
<br />CLEANSOND CAP
<br />LEAD FLASHING CANTED BEAD OF
<br />MBR UTILITY CEMENT
<br />' PRIME FLANGE OF LEAD FLASHING
<br />WITH PRIMER ON BOTH SIDES,
<br />(SEE NOTES) SET LEAD FLANGE IN
<br />MBR UTILITY CEMENT, OR MBR
<br />€ r FLASHING CEMENT.
<br />! ROUND CORNERS \
<br />I OF TARGET PATCHES
<br />'0'AS SHOWN
<br />MBR FLASHING
<br />j CEMENT, OR MBR
<br />UTILITY CEMENT
<br />C
<br />P
<br />G <� J ,� PP
<br />M App
<br />�O h
<br />NOTES:
<br />1. REFER TO JOHNS MANVILLE WEBSITE (www.jm.com) FOR MOST UP-TO-DATE INFORMATION.
<br />2. LEAD FLASHING SHALL BE 2.5 LBS. PER SQUARE FOOT MINIMUM.
<br />3. IF LEAD FLASHING IS NOT DESIRED OR PIPE IS TOO TALL, SEE PERMAFLASH DETAIL PMF-6 & PMF-6S FOR A SUITABLE ALTERNATIVE.
<br />4. USE ASPHALT PRIMER ON LEAD FLANGES WHEN USING MBR UTILITY CEMENT.
<br />S. USE PERMAFLASH PRIMER ON LEAD FLANGES WHEN USING MBR FLASHING CEMENT.
<br />6. ANY CARPENTRY, METAL WORK, OR MASONRY CONSTRUCTION SHOULD BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH
<br />LOCAL CODE REQUIREMENTS AND/OR PROJECT SPECIFICATIONS. THESE COMPONENTS SHOULD BE REVIEWED AND APPROVED BY A
<br />LICENSED DESIGN PROFESSIONAL.
<br />7. PLEASE SEE BITUMINOUS FLASHING SPECIFICATIONS FOR A FULL DESCRIPTION OF INSTALLATION INSTRUCTIONS AND
<br />REQUIREMENTS WHICH ARE CONSIDERED A PART OF THIS DETAIL.
<br />DRAWING NO. PLUMBING VENT
<br />C Y E - VQ MEMBRANE TYPE.
<br />Mrs onn MenvtN o a marcoua . d nararome radlrg products and then Ns a or re t cmcepa y
<br />DRAINS &VENTS BUR an�yoneasawDWsarue essionallario dntary esigniaddoocumentais not to cetbn d�requireeddbybu�leung
<br />SCALE I ISSUE DATE MAXIMUM GUARANTEE TERM: ode• cohered, of sociable law. By awaptlg thim oontmens you agree tlmy do not conatiWo my
<br />N.T.S 12-10 18 �roeppresentaa !, endaee snob rn, a an aswr eon by Johns MarMle d any IeDunq br salter the jwjM
<br />a0equaty rn Ne deep of fh building a any or nubrlal not suppled ty Johns Manvab.
<br />MBR FLASHING CEMENT
<br />OR MBR UTILITY CEMEN
<br />METAL SET IN MBR
<br />FLASHING CEMENT OR
<br />MBR UTILITY CEMENT
<br />NAILS APPROX.
<br />3" O.C. STAGGERED-
<br />ApoR
<br />o�Fo
<br />8"^ltti
<br />Ml
<br />" (I a
<br />N rOR 44S/Y'
<br />CgSylNcsJ 6j
<br />3
<br />m�
<br />m
<br />�o
<br />o
<br />METAL GRAVEL STOP,
<br />PRIME FLANGE ON BOTH
<br />SIDES (SEE NOTES)
<br />EXTEND ONE PLY OR
<br />A SEPARATE MEMBRANE
<br />TO TURN DOWN EDGE
<br />WOOD NAILERS
<br />FASTEN AS REQ'D.
<br />GUTTER PER
<br />SMACNA
<br />GUTTER STRAPS
<br />NOTES:
<br />1. REFER TO JOHNS MANVILLE WEBSITE (www.jm.com) FOR MOST UP-TO-DATE INFORMATION.
<br />2. *AN SBS BACKER PLY EXTENDING 8" FROM THE EDGE OF THE ROOF IS REQUIRED FOR EXTENDED TERM 25 AND 30 YEAR GUARANTEES,
<br />3. ANY CARPENTRY, METAL WORK, OR MASONRY CONSTRUCTION SHOULD BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH LOCAL
<br />CODE REQUIREMENTS AND/OR PROJECT SPECIFICATIONS. THESE COMPONENTS SHOULD BE REVIEWED AND APPROVED BY A LICENSED
<br />DESIGN PROFESSIONAL. CONTACT JM TECHNICAL FOR METAL OPTIONS TO BE INCLUDED WITHIN THE JM NDL GUARANTEE.
<br />4. SHOP FABRICATED GRAVEL STOPS AND GUTTERS SHOULD BE INSTALLED IN ACCORDANCE WITH SMACNA AND/OR NRCA GUIDELINES.
<br />GRAVEL STOP LAPS SHALL UTILIZE EITHER APPROVED SPLICE PLATES OR 4" MINIMUM OVERLAPS WITH APPROVED SEALANT.
<br />S. PLEASE SEE BITUMINOUS FLASHING SPECIFICATIONS FOR A FULL DESCRIPTION OF INSTALLATION INSTRUCTIONS AND REQUIREMENTS
<br />WHICH ARE CONSIDERED A PART OF THIS DETAIL
<br />6. USE ASPHALT PRIMER ON GRAVEL STOP FLANGES WHEN USING MBR UTILITY CEMENT. USE PERMAFLASH PRIMER ON GRAVEL STOP
<br />FLANGES WHEN USING MBR FLASHING CEMENT.
<br />DRAWING NO. ROOF EDGE GUTTER
<br />BE-4 (GTR) MEMBRANE TYPE
<br />FLASHING EDGE BUR Julia Manville is a s manufacturer d n ownplane roolirg products and ttob tll! gerrmal
<br />etormaon b you a a weary. Tits omnpamamfaly assistance s not b be wad a fused 14. by
<br />anyone a a substNte or prdessianal engraving design are documentation required by building
<br />SCALE ISSUE DATE MAXIMUM GUARANTEE TERM: code, warva or applicable law, By swepttrg lime wmmeuts you agree bey do not constitute any
<br />N.T.S 12-10-18 represenbaws, andonenenb rn. a an assxnpaon oy Johns Marvin d anyy it ty tat edhar Me
<br />adequacy of the design offis building dirg any cafe Alienist AN supplied by JMn! Mamms. i1/1
<br />HEX HEAD
<br />FASTENERS--�
<br />FASTEN MEMBRANE
<br />6" O.C. ON BACK
<br />SIDE OF WALL
<br />JM SINGLE PLY MEMBRANE
<br />ADHERED TO WALL
<br />WOOD NAILER FASTENED
<br />AS REQUIRED
<br />JM SINGLE PLY
<br />MEMBRANE ADHESIVE
<br />FASTEN 12" O.C. W/
<br />APPROVED FASTENERS
<br />3 COURSING
<br />(OPTIONAL)
<br />MASONRY
<br />WALL
<br />ASPHALT --��
<br />PRIMER
<br />FESCANT�
<br />PLUS
<br />PRESTO LOCK METAL
<br />COPING COVER
<br />PRESTO LOCK
<br />ANCHOR CLIP
<br />V-0" MAX. WITHOUT
<br />INTERMEDIATE
<br />VERTICAL FASTENING
<br />FOR WALL FLASHINGS OVER V-0"
<br />HIGH INTERMEDIATE FASTENING
<br />IS REQUIRED AT 5'-0" INTERVALS
<br />4" MIN. COUNTER FLASHING
<br />OVERLAP PAST TOP OF BASE
<br />FLASHING
<br />8" MIN. TO 24"
<br />MAX. BASE
<br />FLASHING
<br />4" MIN. (1 FLASHING)
<br />OR
<br />IN. (2 FLASHINGS)
<br />METAL
<br />01WMETAL COUNTER FLASHING
<br />•* MASONRY FASTENERS WITH 1" MIN. 0
<br />- PLATE 6" O.C. AT TOP EDGE
<br />- JM CLEANSOND CAP
<br />MBR FLASHING CEMENT OR
<br />- MBR UTILITY CEMENT
<br />SA/SA A/SAj�////
<br />NOTES:
<br />1. REFER TO JOHNS MANVILLE WEBSITE (www.jm.com) FOR MOST UP-TO-DATE INFORMATION.
<br />2. *AN SBS BACKER PLY EXTENDING 2" MIN. FROM TOE OF CANT IS REQUIRED FOR EXTENDED TERM 25 AND 30 YEAR GUARANTEES.
<br />3. **A TERMINATION BAR FASTENED 6" O.C. IS AN ACCEPTABLE SECUREMENT ALTERNATIVE ALONG THE TOP EDGE OF THE FLASHING.
<br />4. ANY CARPENTRY, METAL WORK, OR MASONRY CONSTRUCTION SHOULD BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH
<br />LOCAL CODE REQUIREMENTS AND/OR PROJECT SPECIFICATIONS. THESE COMPONENTS SHOULD BE REVIEWED AND APPROVED
<br />BY A LICENSED DESIGN PROFESSIONAL.
<br />S. INSTALL PRESTO LOCK COPING IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS INCLUDED WITH THE PRODUCT.
<br />PREFABRICATED INSIDE/OUTSIDE CORNERS AND END CAPS ARE AVAILABLE TO COMPLETE THE INSTALLATION. SHOP FABRICATED
<br />COPINGS SHOULD BE INSTALLED IN ACCORDANCE WITH SMACNA GUIDELINES.
<br />6. VERTICAL JOINTS ARE TO BE OVERLAPPED 4" MINIMUM FOR ALL APPLICATIONS. 3 COURSING WITH MBR UTILITY CEMENT AND
<br />FABRIC OR JM MBR FLASHING CEMENT IS RECOMMENDED ON ALL VERTICAL FLASHING LAPS AND INSIDE/OUTSIDE CORNERS
<br />EXTENDING PAST LEADING EDGE OF CANT STRIP.
<br />7. PLEASE SEE BITUMINOUS FLASHING SPECIFICATIONS FOR A FULL DESCRIPTION OF INSTALLATION
<br />INSTRUCTIONS AND REQUIREMENTS WHICH ARE CONSIDERED A PART OF THIS DETAIL.
<br />DRAWING NO. SINGLE PLY WALL COVERING WITH BITUMINOUS BASE FLASHING
<br />CBE-15 MEMBRANE TYPE:
<br />Jofrre Mamie s e nanufacturor d wmnurcht nary a products and don this tee r Allied
<br />edconceptull
<br />by
<br />BUR Nbmtatlon b yw a s wurlesy This canpmneralay assistance b not to be used a r1WW upon by
<br />amone as a euDsUtde br D tend englneerug design and tloatmeraeran rewired by butl0rg
<br />SCALE ISSUE DATE MAXIMUM GUARANTEE TERM: code, contract. or appacatle IN By eceephnij Ihele wnanem! you agree the do not caaAtrie any
<br />N.T.S 02 0$-19 ropr w"9011 fe aeatgri a tNi bozo a an aria; t trm by jdm Marnble olany iiet3*I la ether the
<br />a0eg Ndag a arty doer rat wprtled try Johns aimvMe.
<br />HEX HEAD PRESTO LOCK METAL
<br />FASTENERS COPING COVER
<br />WATERPROOF PRESTO LOCK
<br />MEMBRANE ANCHOR CLIP
<br />1" DIA. CAP NAILS
<br />6" O.C. AT TOP
<br />JM BASE SHEET
<br />OPTIONAL
<br />WOOD NAILER
<br />FASTENED AS
<br />REQUIRED
<br />3�,�,1D GAP
<br />8" MIN. TO 24" MAX.
<br />BASE FLASHING HT.
<br />4" MIN. (1 FLASHING)
<br />+'na11pN` OR
<br />6" MIN. (2 FLASHINGS)
<br />NAILED 9" D.C.----
<br />BOTH DIRECTIONS
<br />g
<br />WALL Oy
<br />FESCANT
<br />PLUS
<br />CLEANSOND CAP
<br />MBR FLASHING CEMENT OR
<br />MBR UTILITY CEMENT
<br />CLEANSOND SA/SA
<br />as
<br />�eFr
<br />NOTES:
<br />1. REFER TO JOHNS MANVILLE WEBSITE (www.jm.com) FOR MOST UP-TO-DATE INFORMATION.
<br />2. *AN SBS BACKER PLY EXTENDING 2" MIN. FROM TOE OF CANT IS REQUIRED FOR EXTENDED TERM 25 AND 30 YEAR GUARANTEES.
<br />3. INSTALL PRESTO LOCK COPING IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS INCLUDED WITH THE PRODUCT.
<br />PREFABRICATED INSIDE/OUTSIDE CORNERS AND END CAPS ARE AVAILABLE TO COMPLETE THE INSTALLATION. SHOP
<br />FABRICATED COPINGS SHOULD BE INSTALLED IN ACCORDANCE WITH SMACNA GUIDELINES.
<br />4. VERTICAL JOINTS ARE TO BE OVERLAPPED 4" MINIMUM FOR ALL APPLICATIONS. 3 COURSING WITH MBR UTILITY CEMENT AND
<br />FABRIC OR JM MBR FLASHING CEMENT IS RECOMMENDED ON ALL VERTICAL FLASHING LAPS AND INSIDE/OUTSIDE CORNERS
<br />EXTENDING PAST LEADING EDGE OF CANT STRIP.
<br />S. ANY CARPENTRY, METAL WORK, OR MASONRY CONSTRUCTION SHOULD BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH
<br />LOCAL CODE REQUIREMENTS AND/OR PROJECT SPECIFICATIONS. THESE COMPONENTS SHOULD BE REVIEWED AND APPROVED BY A
<br />LICENSED DESIGN PROFESSIONAL. CONTACT JM TECHNICAL FOR METAL OPTIONS TO BE INCLUDED WITHIN THE JM NDL GUARANTEE.
<br />6. PLEASE SEE BITUMINOUS FLASHING SPECIFICATIONS FOR A FULL DESCRIPTION OF INSTALLATION INSTRUCTIONS AND
<br />REQUIREMENTS WHICH ARE CONSIDERED A PART OF THIS DETAIL.
<br />DRAWING NO. BASE FLASHING FOR WOOD WALL > 24" W/ COPING
<br />CBE-3 (HM MEMBRANE TYPE:
<br />johns Marwile b a marMacaax of eonanerclal roofing pY *xb and often fb p erM wnxptual
<br />BUR tnbmiseon b you a a =may This canplimarary swislanoa s not to be uaad a nod upon by
<br />anyone as a stboule for fesslonal &Vme" dalgn and documeraatbn reared by bhidng
<br />SCALE ISSUE DATE MAXIMUM GUARANTEE TERM -
<br />representations
<br />contract, or appkatle law By acapbng tMes oo nitwit you agree tr ey ce not wrrbaae any
<br />N.T.S 02-06-19 representations endon arnsns of, a an assumption by Jahn Manville d any fiabiay for elf it the
<br />adequacy d the design deaf buiMirip a dry oiler rtstenal not wpptod by Johns Manville. ■
<br />U 0
<br />[tamps
<br />URBANORDER.tampa, Inc.
<br />5006 mouth elhsron street 33611
<br />813.832.507
<br />■m2002460
<br />1URBANoRDERAampa, inc.l
<br />Thee pYrm are copymdhtsd and are WW to
<br />mpr*t pmwtm n an •architectural work' urow
<br />sacdm 102 or the copyright ad. 17 ua& as
<br />-mantled Deceonsr 1990 and knom at amhltec ual
<br />wortu copyrc u P, but Is act al to t e9
<br />taorockm atctctwa but b nd emtted b the comma
<br />bon ae wM a amingsnrnt am owmadtion of
<br />Woos and ebtrients of the dngn, undo such
<br />protection, unauNabed use of Mae owns, work a
<br />home represented, - moy .it in the caseation
<br />of mneluclbn or buildings being 0ued and/or
<br />morwkrry mmponsatldn to URaAJkRDER/Wnps ins.,
<br />Fbrlda registration M2e002180.
<br />ISSUE DATE
<br />05/15/2019
<br />REVISIONS
<br />N
<br />M
<br />M
<br />U
<br />�
<br />ICU
<br />Z
<br />M
<br />0
<br />U
<br />U_
<br />c
<br />Q
<br />cur
<br />v)
<br />`
<br />/
<br />W
<br />!E
<br />L
<br />W
<br />N
<br />U)
<br />J
<br />JOE TOPH.
<br />FL,REG. AR10095
<br />DATE: I M 912020
<br />DRWN:
<br />CHKD:
<br />SCALE.
<br />SHEET NUMBER
<br />A=28
<br />z hills 11119/2020 11:28:48 AM
<br />
|