u- n ,.,:,r.,a,w■ I t i �Ip�il�i t'} a �f <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />L.® <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />6. <br />P4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />lO <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />�P <br />PUSH BUTTON SWITCH (OPTIONAL) <br />Df [B] <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />a 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />Ci J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G T J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />AIL <br />I <br />I <br />I <br />I I <br />I I <br />I I <br />� I I <br />LAV 1\ <br />� I <br />U TUB/ <br />W/C SHOWER <br />LAV <br />3" VTR <br />JIL <br />I <br />I <br />I <br />I <br />I OPT. <br />LAV <br />ILAV <br />I <br />I <br />_U W/C <br />SHOWER <br />--_ 2n0' F FC <br />STUDOR <br />VENTI , DBL SINK <br />T' W/ DISP. <br />W/C <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS <br />Unit -B- (1516) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1505 S.F. <br />4515 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10515 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33575 <br />1st 10 KW at 100% <br />10000 <br />BALANCE OF WATTS AT 40% <br />9430 <br />AIR CONDITIONER WATTS AT 166 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 <br />5200 <br />TOTAL: 31734 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Optional Overhead Service <br />Same As Underground <br />150 Or 200 Amp Service <br />1 <br />Power Co. Feed <br />200A <br />Indoor Panel <br />Center <br />NEMA1 <br />RMAN <br />200 AMP <br />NEM <br />3R <br />Cable <br />#4 Solid COPPER Ground <br />II <br />Intersystem Bonding <br />Termination Per <br />NEC 08, 250.94 5/8" Galvanized Driven Ground <br />Rods at least 6' apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />C.O. <br />DISCONNECT <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE <br />RANGE HOOD PER <br />SPECS <br />--------- <br />OUTDOOR LIVING <br />> INSTALL LIGHT <br />ROUGH -IN <br />FOR OPT. <br />GFI <br />.i AN/LIGHT <br />n. <br />GFI / <br />IF� <br />�I <br />I <br />DINING <br />�I <br />I <br />f KITCHEN <br />�I 1 <br />Olt <br />I <br />_4 <br />L---- <br />GFI <br />SWITCH FOR <br />DISPOSAL IN CAB <br />C.M. UNDER SINK <br />1 <br />II / <br />I <br />I / <br />GREAT ROOM <br />ROUGH -IN<,,\ <br />CH FOR OPT. <br />' FAN/LIGHT J �> <br />1 I <br />I <br />UPSTAIRS 1 I <br />I <br />FI FOYER <br />rMi <br />GFI / <br />W.H.7@ 44" <br />I <br />\ DB <br />GARAG E 1 , I ENT <br />GFI LIGHT <br />/ PER SPE <br />GARAGE <br />LIGHT AS I <br />PER SPECS <br />GARAGE <br />DOORGFI <br />I <br />I I \ <br />I ZIW \ <br />I OlzQ \ <br />Q IC- <br />I U I-j _ \ <br />I O IL) W F- 1 <br />I I� I— <br />I LL IH W Z <br />I �IW _ <br />I WIC �� <br />>IW �LLUJ / <br />>0m <br />COACH LIGHTS i <br />OR PREWIRE AS <br />PER SPECS <br />DB&GFI TO <br />BE ALIGNED <br />VERTICALLY <br />1ST ELECTRICAL — UNIT—B 1516 <br />SCALE: Y4"=1'-0" <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />— — — —1 <br />I <br />2ND ELECTRICAL — UNIT—B 1516 <br />SCALE: Y4"=1'-0" <br />f <br />U h <br />w T1 <br />n <br />s <br />C&- <br />No Z' �l <br />qj <br />ca-M <br />O <br />U <br />CQi �.. <br />��tL•dW <br />.�. <br />N <br />0 <br />N <br />rn <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural <br />plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />9! <br />W <br />a <br />d Eq <br />-• <br />fJ <br />(0MGM <br />O N <br />N <br />u' o <br />r <br />Lo co <br />Y/ <br />� <br />Cn i` r- .9 <br />tIi <br />a <br />N O # L <br />ID M �r <br />L, <br />ll <br />- <br />CoLLioLOU- <br />Z <br />o <br />W <br />7 (6 NO <br />Z <br />U <br />O 0 m w <br />C <br />04 M Z J <br />Z <br />N <br />W <br />❑❑ <br />N th <br />o <br />z 10 <br />} <br />< <br />W <br />a <br />N <br />M <br />�N <br />Ur o <br />(Q <br />w <br />� <br />V <br />OLLJflu <br />NU) <br />S <br />Ly N <br />'J <br />U) <br />•,� <br />U <br />"' <br />r— J E <br />L 8 <br />zI1 <br />Q g <br />N <br />sm <br />co <br />Mm <br />w <br />M <br />¢ <br />O SS <br />Z <br />a <br />� <br />LJL <br />a_ E <br />a <br />E <br />w o <br />o0 <br />Z p <br />z® <br />fcu ro <br />x� <br />�= <br />00 <br />o< <br />o @ <br />04 <br />aZ <br />o <br />-Z <br />r <br />L <br />Cn <br />Z <br />or <br />U <br />m 0 <br />0- <br />Z <br />_ <br />h -0 <br />Q Z <br />Z <br />C1 <br />O� <br />OLL <br />Qo <br />0 <br />a <br />N W <br />C) <br />< o <br />oW <br />61 <br />>° <br />a <br />to <br />v <br />z< <br />aF <br />o r <br />.L <br />TT <br />ai <br />N <br />CO <br />N— <br />Cn <br />co <br />M <br />L'> <br />O <br />r <br />� <br />cV <br />^ <br />CL <br />O <br />itCID <br />M <br />r <br />o <br />C m <br />O <br />00 <br />r <br />E M <br />� <br />C:) <br />N <br />o <br />Ln <br />co <br />Q O <br />LC) <br />OO <br />LO <br />r <br />Eo <br />E <br />CDv; <br />z <br />ca <br />Z <br />E O <br />FLU <br />E <br />o _ <br />a m <br />¢ o <br />JOB <br />NO: 22-05628-05621 <br />SCALE . <br />AS NOTED <br />SHEET NO. <br />14 <br />