My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38235 Fallstone Way
Zephyrhills
>
Building Department
>
Building Plans
>
38235 Fallstone Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 4:51:31 PM
Creation date
2/19/2025 8:02:43 AM
Metadata
Fields
Template:
Building Plans
Street #
38235
Location
Fallstone Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
4788
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />3" VTR <br />NOTES: <br />3" VTR <br />JIL <br />JIL <br />I <br />ELECTRICAL CONTRACTOR <br />I <br />MUST VERIFY WITH THE <br />I <br />j <br />SPECIFICATIONS FOR THE TYPE <br />I <br />I <br />OF FIXTURE TO BE USED. LIGHT <br />— <br />OAV • <br />FIXTURES SHOWN ARE FOR <br />— i <br />—�� <br />I <br />LAv <br />LOCATION PURPOSES. <br />j HANSON <br />I BOX <br />I I <br />j <br />I <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />K* <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />j4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />I__0 <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />® D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />�P <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />N <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />JD_ <br />ELECTRIC PANEL <br />j <br />DISCONNECT SWITCH <br />J <br />ROUGH -IN FOR OPT. CEILING FAN <br />G <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />'7 <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />---- I I W/C <br />LAV 1\ I 1 SHOWER <br />3„ <br />>J TUB/ <br />W/C SHOWER <br />OUTDOOR LIVING <br />STUDOR C.O. /` <br />VENT W/ SINK INSTALL LIGHT ��� /i� <br />W/ DISP. ROUGH -IN f <br />fi <br />2' FOR OPT. <br />L�JAV W/C 3" 3 FAN/LIGHT ` `� �' WFP <br />2" <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS <br />Unit -C- (1624) <br />SQ. FT, AT 3 WATTS / SQ. F.T. <br />1625 S.F. <br />4875 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10875 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33935 <br />1st 10 KW at 100% <br />10000 <br />BALANCE OF WATTS AT 40% <br />9574 <br />AIR CONDITIONER WATTS AT 100% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 <br />5200 <br />TOTAL: 31878 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Optional Overhead Service <br />Same As Underground <br />150 Or 200 Amp Service <br />Power Co. Feed <br />200A <br />Indoor Panel <br />Center <br />NEMA1 <br />200 AMP <br />ERMAN <br />3R <br />Cable <br />#4 Solid COPPER Ground <br />Intersystem Bonding <br />Termination Per <br />NEC 08, 250.94 518" Galvanized Driven Ground <br />Rods at least 6' apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />DB&GFI TO <br />BE ALIGNED <br />VERTICALLY <br />a <br />O <br />DISCONNECT <br />QD QDGFI <br />----- --- <br />1 <br />DINING <br />KITCHEN <br />/ F— — — <br />� <br />FI O <br />- --- GFI �� --- <br />SWITCH FOR• <br />DISPOSAL IN CAB <br />UNDER SINK <br />GREAT ROOM <br />/,,>ROUGH -IN\ <br />FOR OPT. <br /><���FAN/LIGHT 1 <br />I <br />I <br />NTRY <br />IGHT AS 0ER SPECS <br />I <br />I <br />I u <br />L <br />\QUj <br />Uj <br />on <br />_04—co <br />1 ". <br />*0.4 - • - <br />�0"All - <br />WAN •�� - <br />►A <br />M01 <br />I <br />I <br />I <br />I <br />I <br />I <br />�gFEL <br />j UPSTAIRS F <br />GFI <br />@ 44" <br />LW. <br />A.F.F. <br />` 0 <br />I <br />I <br />I GARAG E <br />I <br />GARAGE <br />LIGHT AS <br />NPER SPECS <br />GARAGE <br />DOOR <br />GFI <br />--------------- <br />1 <br />I J <br />I <br />I <br />IpLU <br />Z <br />I <br />IQ � <br />I <br />I0 Q <br />I <br />IJ U <br />I <br />ILL U <br />I <br />Iw Uj <br />I <br />I> W <br />I <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />1ST ELECTRICAL -UNIT-C 1624 <br />SCALE Y4"=1'-0" <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />2ND ELECTRICAL - UNIT-C 1624 <br />SCALE: Y4"=1'-0" <br />e <br />C14H a- 01i <br />a-z. <br />0- <br />Ln -0 <br />,.- C: <br />- ci'3:- •� tT� <br />/!l <br />«Q� <br />< <br />r <br />�° <br />N <br />0 <br />CV <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />M <br />W a E <br />0 <br />g O co s <br />V N a`) N <br />N <br />vi co V 22 u <br />N w <br />J <br />Q J W �i� , a <br />� <br />(' 0 w <br />o- <br />0 <br />Z <br />�8 <br />_ <br />Fe � <br />1% e & (; 0 <br />� <br />O_jO' m w <br />Z ILN NZ <br />ILW <br />ov o <br />Z <br />W El El <br />0 <br />Z N M <br />o g <br />z o � <br />J — <br />CL_ <br />E3 <br />N <br />1 f1 a� <br />U) <br />uJ � <br />� <br />� o <br />U w <br />�N <br />U <br />r, r <br />J <br />E <br />m $ <br />mop <br />mi <br />l� ... <br />z <br />U o h <br />c o <br />N 0 <br />° <br />®0 <br />sea <br />o <br />w <br />M <br />M <br />z ¢ <br />O <br />Z <br /><o E <br />�� <br /><� <br />a p <br />E U <br />wLL <br />. <br />ZB <br />wa <br />cc <br />I— <br />— <br />XO <br />¢a <br />00 <br />, <br />O` <br />E <br />N <br />o <br />4z <br />� <br />a <br />¢w <br />d L <br />U <br />mO <br />Z <br />N <br />I <br />m <br />F� <br />¢w <br />gZ <br />o< <br />go <br />a1 <br />� <br />¢ <br />a <br />�w <br /><o <br />.1 <br />=S <br />WF <br />>o <br />o <br />V� <br />zlar <br />a <br />3 <br />o r <br />>� <br />ai <br />rn <br />N <br />C� <br />cT� <br />N <br />cL7 <br />M <br />Cfl <br />LC� <br />O <br />T <br />CID <br />CD <br />V <br />6 <br />Lillo <br />V <br />% CD <br />G <br />00 <br />E co <br />�CD <br />Cn <br />� �� <br />Q p <br />Il O <br />00 <br />lt) <br />r <br />y <br />E <br />c <br />o <br />Z <br />m <br />Z <br />3 v; <br />E C) m <br />m <br />c <br />a <br />Ei <br />U � Q p <br />c <br />a) <br />JOB <br />NO: 22-05628-05621 <br />SCALE: AS NOTED <br />SHEET NO. <br />15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.