GENERAL NOTES: <br />THIS BUILDING HAS BEEN DESIGNED TO CONFORM TO THE 2D10 FLORIDA BUILDING CODE <br />ARKAY ENGINEERING, INC.; A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL <br />ENGINEERING COMPANY; HAS APPLIED "RATIONAL ANALYSIS" FOR THE STRUCTURAL DESIGN <br />OF THIS STRUCTURE. <br />THE BUILDING ( INCLUDING ALL COMPONENTS AND CLADDINGS) SHALL BE DESIGNED FOR THE <br />FOLLOWING SUPERIMPOSED LOADS: <br />FLOORS: <br />LIVE LOAD - 50 P.S.F. <br />DEAD LOAD - 10 P.S.F. <br />ROOF: <br />LIVE LOAD ( TRUSS TOP CHORD) - 20 P.S.F. <br />DEAD LOAD ( TRUSS TOP CHORD) - 10 P.S.F. <br />DEAD LOAD ( TRUSS BOTTOM CHORD) - 10 P.S.F. <br />ASSUMED TRUSS SELF WEIGHT ( DEAD LOAD) - 7 P.S.F. <br />WIND: <br />BUILDING IS DESIGNED TO CONFORM TO ASCE 7-10, CHAPTERS 26 THRU 31; PER 2010 FLORIDA <br />BUILDING CODE SECTION 1609.1.1. <br />VVINL) ut51Vry HSSUMF I IUNs: <br />BUILDING EXPOSURE - B <br />BUILDING RISK CATEGORY - II <br />MEAN ROOF HEIGHT 30' OR LESS <br />HEIGHT & EXPOSURE ADJUSTMENT <br />COEFFICIENT = 1.0 <br />ENCLOSED BUILDING <br />INTERNAL PRESSURE COEFFICIENT = +/- 0AB <br />WIND SPEED SHOWN AT THE BOTTOM RIGHT <br />CORNER OF THIS SHEET <br />ALL STRUCTURAL ELEMENTS, EXTERIOR <br />WALLS AND INTERIOR WALLS SHALL BE <br />TYPE V CONSTRUCTION PER FBC 602Z <br />COMPONENT & CLADDING WIND LOADS <br />ALL OTHER <br />BUILDING <br />ROOF OVERHANG <br />COMPONENT <br />ZONE <br />LOADS <br />LOADS <br />1 <br />NIA <br />+32.3/-35.3 <br />2 <br />-65.7 <br />+32.3/-56.2 <br />3 <br />-110.6 <br />+32.3/-89.0 <br />4 <br />N/A <br />+35.3/-38.2 <br />5 <br />N/A <br />+35.3/-47.2 <br />SOIL BEARING & COMPACTION: <br />THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE SOIL BEARING CAPACITY OF 2,000 P.S.F. <br />(MINIMUM . THE CONTRACTOR/PROPERTY OWNER ARE RESPONSIBLE FOR VERIFYING THAT THE SOIL <br />ON THE SITE IS PROPERLY PREPARED & COMPACTED SUCH THAT IT CAN SUPPORT A 2,000 P.S.F. <br />FOUNDATION LOADING. <br />ARKAY ENGINEERING, INC.; A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL <br />ENGINEERING COMPANY; DESIGNED THESE FOUNDATIONS WITHOUT VISITING THE CONSTRUCTION SITE <br />NOR PERFORMING ANY SOIL TESTING. <br />ARKAY ENGINEERING, INC. SHALL NOT BE RESPONISIBLE FOR THE SITE SOILS ABILITY TO SUPPORT <br />THE BUILDING LOADS. <br />FOUNDATIONS & SLAB -ON -GRADE: <br />BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATERIALS WITHIN THE BUILDING AREA. <br />ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AREA, SHALL BE COMPACTED <br />SUCH THAT IT CAN ADEQUATELY SUPPORT A 2,000 P.S.F. FOUNDATION LOADING. <br />SLAB SHALL BE PLACED OVER A 6 MIL VAPOR BARRIER ON CLEAN, ADEQUATELY <br />COMPACTED AND TERMITE POISONED SOIL. <br />CONCRETE UTILIZED IN THE FOUNDATIONS AND SLABS SHALL HAVE A MINIMUM 28 DAY <br />COMPRESSIVE STRENGTH OF 2,500 P.S.I. <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE <br />WITH ASTM A-615. LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25" <br />FOR #5 REBAR, 30" FOR #6 REBAR & 35" FOR #7 REBAR. <br />PLANS ARE ENGINEERED FOR A MAXIMUM STEMWALL HEIGHT OF 4 COURSES ( AFTER <br />FINAL SITE GRADING) . THE CONTRACTOR OR BUILDING OWNER SHALL DETERMINE THE <br />EXACT STEMWALL HEIGHT BASED UPON SITE CONDITIONS PRIOR TO POURING THE FOUNDATION <br />AND CONTACT ARKAY ENGINEERING WHEN MORE THAN 4 COURSES ARE REQUIRED. <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON THE <br />SITE FOR THE BUILDING INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND <br />A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY THE REQUIRED BUILDING SETBACKS. <br />1/2" CDX ROOF SHEATHING NAILED PER ROOF <br />SHEATHING DETAIL WITH 8D RS NAILS. COVER <br />WITH #30 FELT.INSTALL MASTER RIB 26 GA <br />PAINTED STEEL ROOFING OR EQUAL AS PER <br />MANUFACTURES SPECIFICATIONS <br />SECURE ALL ROOF TRUSSES TO BLOCK WALLS <br />USING SIMPSON HETA20 TRUSS STRAPS, FILL <br />NAIL HOLES WITH 10DX 1 1/2' NAILS <br />TOP OF BLOCK WALL 8' 4" <br />I I <br />1' 4" I_ 2' 0" <br />2X4 WOOD SUB FASCIA WITH OVERHANG CANTILEVER <br />ALUMINUM FASCIA, DRIP AND <br />SOFFIT MATERIALS <br />NO INSULATION IN WALLS <br />0 <br />60 <br />STRUCK JOINT PAINTED <br />BLOCK WALLS ON EXTERIOR <br />BUILDING FINISH FLOOR 0' 4" <br />APPROXIMATE FINAL GRADE 0' 0" <br />co <br />BOTTOM OF FOOTING <br />SOIL TERMITE TREATMENT: PER FBC 2304.11 <br />TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING PESTICIDES <br />APPLIED TO SOIL, OR WOOD, BAITING SYSTEMS, OR OTHER APPROVED PROTECTION LABELED FOR <br />USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. <br />A "CERTIFICATE OF COMPLIANCE" SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED <br />PEST CONTROL COMPANY BEFORE A "CERTIFICATE OF OCCUPANCY" WILL BE ISSUED. THE CERTIFICATE <br />SHALL STATE <br />"THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA <br />DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." <br />INITIAL SOIL POISONING TREATMENT SHALL BE DONE AFTER ALL EXCAVATION, <br />BACKFILLING & COMPACTION ARE COMPLETE <br />ANY SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RE -TREATED <br />( INCLUDING ANY BOXED OR FORMED AREAS) - <br />BOXED AREAS IN THE CONCRETE SLAB FOR INSTALLATION OF TRAPS SHALL BE MADE <br />WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF AN <br />ADEQUATE SIZE & DEPTH TO ELIMINATE ANY DISTURBANCE OF THE SOIL AFTER THE <br />INITIAL TREATMENT. <br />A MINIMUM 6 MIL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL <br />DILUTION. IF RAINFALL OCCURS BEFORE VAPOR BARRIER PLACEMENT, RE -TREATMENT <br />SHALL BE REQUIRED <br />ANY CONCRETE OVERPOUR, MORTAR OR STUCCO MATERIALS ALONG THE FOUNDATION PERIMETER <br />MUST BE REMOVED PRIOR TO EXTERIOR SOIL TREATMENT <br />EXTERIOR SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />WITHIN 12 INCHES OF THE STRUCTURE SIDE WALLS <br />AN EXTERIOR VERTICAL CHEMICAL BARRIER SHALL BE INSTALLED AFTER CONSTRUCTION IS <br />COMPLETE ( INCLUDING LANDSCAPING AND IRRIGATION) . ANY SOILS DISTURBED AFTER THE <br />VERTICAL BARRIER IS APPLIED, SHALL BE RE -TREATED. <br />CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 12 INCHES AWAY FROM THE <br />BUILDING SIDEWALLS <br />AFTER ALL WORK IS COMPLETED, ANY LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW <br />AND WITHIN 12 INCHES OF THE BUILDING. THIS SHALL INCLUDE ALL GRADE STAKES, TUB TRAP BOXES <br />FORMS, SHORING AND ANY OTHER CELLULOSE CONTAINING MATERIALS. <br />THE DISTANCE FROM THE EXTERIOR WALL COVERING ( EXCEPTIONS: PAINT AND DECORATIVE <br />CEMENTITIOUS FINISHES LESS THAN 5/6 INCH THICK ADHERED DIRECTLY ONTO THE FOUNDATION <br />WALL) AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6 INCHES TO ALLOW FOR INSPECTION <br />FOR FUTURE TERMITE INFESTATIONS <br />EXTERIOR WINDOWS & DOOR ASSEMBLIES: <br />ALL EXTERIOR WINDOW & GLASS DOORS SHALL BE TESTED IN ACCORDANCE WITH ANSI/AMMA/NWWDA <br />101/IS2 STANDARDS AND BEAR AN AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER, <br />PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY. <br />ALL MULLIONS AND ADJACENT DOORIWINDOW ASSEMBLIES SHALL BE TESTED OR ENGINEERED TO <br />TRANSFER 1.5 TIMES THE DESIGN LOADS TO THE ROUGH OPENING SUBSTRATE. <br />INSTALL ALL WINDOW & DOOR ASSEMBLIES PER THE MANUFACTURERS ANCHORING RECOMMENDATIONS <br />TO ACHEIVE THE DESIGN PRESSURES SPECIFIED. <br />SAFETY GLAZING: <br />THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSES OF <br />GLAZING PER THE FLORIDA BUILDING CODE, RESIDENTIAL - <br />( 1) GLAZING IN SWINGING DOORS, FIXED AND SLIDING PANELS OF SLIDING DOOR <br />ASSEMBLIES. <br />(2) GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM <br />ROOMS, BATHTUBS, AND SHOWERS. GLAZING IN ANY PORTION OF A BUILDING WALL <br />ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS <br />THAN 60 INCHES ABOVE THE DRAIN INLET. <br />(3) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT A DOOR WHERE <br />THE NEAREST VERTICAL EDGE IS WITHIN A 24 INCH RADIUS OF THE DOOR IN A <br />CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE <br />FINISHED FLOOR OR WALKING SURFACE. <br />(4) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS <br />DESCRIBED IN ITEMS (2) AND (3) ABOVE. THAT MEETS ALL OF THE FOLLOWING <br />CONDITIONS: <br />A) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQ. FT. <br />B) BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR. <br />C) TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR. <br />D) ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE <br />PLANE OF THE GLAZING. <br />ENGINEERED ROOF TRUSSES <br />NO INSULATION IN ATTIC <br />4X8 JAMES HARDI 8" VERTICAL GROOVE <br />SHEETS APPLIED TO BOTTOM OF ROOF <br />TRUSSES WITH 8D NAILS 8' OC (TYP) <br />SINGLE COARSE KNOCK OUT LINTEL <br />BLOCK COARSE AT TOP OF WALL WITH <br />145 HORIZONTAL REBAR TIED TO ALL <br />VERTICAL RODS, POUR SOLID WITH <br />3000 PSI CONCRETE <br />_ 8" PRECAST LINTEL OVERALL <br />OPENINGS IN WALL (TYP) <br />STRUCK JOINT PAINTED <br />BLOCK WALLS ON INTERIOR <br />#5VERTICAL REBAR FROM FOOTINGS TO TOP <br />OF WALL AT LOCATIONS SHOWN ON FLOOR AND <br />FOUNDATION PLAN TIED TO ALL REBAR IN LINTEL. <br />AND FOOTINGS. POUR CELL SOLID WITH 3000 PSI <br />CONCRETE. ALL REBAR LAP TO BE MINIMUM 25" <br />4" 3000 PSI CONCRETE OVER CLEAN COMPACT <br />TERMITE TREATED SOIL. COVER WITH 6 MILL <br />VISQUEEN AND USE 616 10/10 WIRE MESH <br />16"X12" 3000 PSI CONCRETE FOOTING <br />WITH WITH 245 REBAR ON CHAIRS <br />USE 1 SIMPSON HETA20 STRAP AT ONE <br />SIDE OF ALL ROOF TRUSSES AT BLOCK <br />WALL. FILL NAIL HOLES WITH 10DX 1/2" <br />NAILS. <br />12' 0" <br />2' 0" <br />I <br />I <br />I <br />/ <br />I <br />I <br />I <br />I <br />/1 <br />I <br />1/2" CDX ROOF SHEATHING NAILED PER ROOF <br />SHEATHING DETAIL WITH 8D RS NAILS. COVER <br />WITH #30 FELT.INSTALL MASTER RIB 26 GA <br />PAINTED STEEL ROOFING OR EQUAL AS PER <br />MANUFACTURES SPECIFICATIONS <br />SECURE ALL ROOF TRUSSES TO BLOCK WALLS <br />USING SIMPSON HETA20 TRUSS STRAPS, FILL <br />NAIL HOLES WITH 10DX 1 1/2' NAILS <br />0 <br />co <br />TOP OF BLOCK WALL 8' 4" <br />_a <br />I <br />1' 4" <br />2X4 WOOD SUB FASCIA WITH OVERHANG I <br />ALUMINUM FASCIA, DRIP AND <br />SOFFIT MATERIALS <br />NO INSULATION IN WALLS <br />STRUCK JOINT PAINTED <br />BLOCK WALLS ON EXTERIOR <br />BUILDING FINISH FLOOR 0' 4" <br />APPROXIMATE FINAL I <br />O <br />BOTTOM OF FOOTING <br />CANTILEVER ROOF LINE <br />00 <br />r <br />ENGINEERED ROOF TRUSS PLAN 1/4" = 1' 0' <br />2X4 CROSS -BRACING @ RIDGE <br />20'-0" MAX <br />mi <br />mm1�11 <br />SEE TRUSS SYSTEM ENGINEERING DRAWINGS FOR ANY ADDITIONAL <br />BRACING OR CROSS BRACING REQUIREMENTS <br />REQ. MINIMUM TRUSS BRACING <br />ENGINEERED ROOF TRUSSES <br />NO INSULATION IN ATTIC <br />4X8 JAMES HARDI 8" VERTICAL GROOVE <br />SHEETS APPLIED TO BOTTOM OF ROOF <br />TRUSSES WITH BD NAILS 8" OC (TYPj <br />SINGLE COARSE KNOCK OUT LINTEL <br />BLOCK COARSE AT TOP OF WALL WITH <br />1-#5 HORIZONTAL REBAR TIED TO ALL <br />VERTICAL RODS, POUR SOLID WITH <br />300D PSI CONCRETE <br />6" PRECAST LINTEL OVER ALL <br />OPENINGS IN WALL (TYP) <br />STRUCK JOINT PAINTED <br />BLOCK WALLS ON INTERIOR <br />#SVERTICAL REBAR FROM FOOTINGS TO TOP <br />OF WALL AT LOCATIONS SHOWN ON FLOOR AND <br />FOUNDATION PLAN TIED TO ALL REBAR IN LINTEL. <br />AND FOOTINGS. POUR CELL SOLID WITH 3000 PSI <br />CONCRETE. ALL REBAR LAP TO BE MINIMUM 25' <br />4" 3000 PSI CONCRETE OVER CLEAN COMPACT <br />TERMITE TREATED SOIL. COVER WITH 6 MILL <br />VISQUEEN AND USE 616 10110 WIRE MESH <br />16"X12" 3000 PSI CONCRETE FOOTING <br />WITH WITH 245 REBAR ON CHAIRS <br />1' 0" �6" <br />WALL SECTION DETAIL S-2 <br />#5 VERTICAL RODS FROM FOOTINGS BELOW TO <br />TOP OF WALL. PLACED AT ALL CORNERS, EACH <br />SIDE OF ALL OPENINGS AND SPACED MAXIMUM <br />VOlt OC <br />TOP/BOTTOM CHORD GABLE <br />7 END BRACING @ 48" O.C. MAX <br />FOR THE FIRST 4 ROWS OF <br />TRUSSES ( MIN 2X4) <br />W <br />J <br />Q <br />0 <br />CONT. BOTTOM CHORD <br />BRACING (1"x4" MIN) @ <br />10'-0" MAX. <br />i <br />t <br />12' 0" 5' 0" <br />--------I�li----------------- <br />li it li it <br />li it li it <br />Ali it I; ,I <br />I II 11 I) <br />II I I I <br />I II I. I <br />4" CONCRETE <br />I i I SIDEWALK <br />3' 4" '14" <br />li il�li it <br />I I I I I------- ---_-_ -- I <br />I I I L —— — — J <br />I----------------------- <br />I II <br />■I� S II <br />II II <br />I I <br />FOUNDATION PLAN 1/4" = 1' 0' <br />NOTE: <br />SEE SANITARY PLAN FOR PLUMBING <br />FIXTURE LOCATIONS <br />51-10„ <br />ROOFEDGE <br />0 <br />yiA <br />22 c1<1 <br />q O <br />Q`Ae <br />O <br />O <br />O I O <br />GABLE END <br />PARTIAL ROOF PLAN <br />ZONE O 8dRING SHANK NAILS AT 6" Q.C. AT EDGES <br />8dRING SHANK NAILS AT 12" O.C. INTERMEDIATE <br />ZONES 2a O 8dRING SHANK NAILS AT 6" O.C., 4" O.C. AT <br />ROOF EDGES, RIDGE LINE, OR GABLE ENDWALL <br />NOTE: END JOINTS FOR SHEATHING SHALL BE STAGGERED <br />AND OCCUR OVER A FRAMING MEMBER. <br />ROOF SHEATHING NAILING <br />NOT TO SCALE <br />ENGINEERED ROOF TRUSSES <br />NO INSULATION IN ATTIC <br />4X8 JAMES HARDI 8" VERTICAL GROOVE <br />SHEETS APPLIED TO BOTTOM OF ROOF <br />TRUSSES WITH BD NAILS 8" OC (TYP) <br />SINGLE COARSE KNOCK OUT LINTEL <br />BLOCK COARSE AT TOP OF WALL WITH <br />145 HORIZONTAL REBAR TIED TO ALL <br />VERTICAL RODS, POUR SOLID WITH <br />3000 PSI CONCRETE <br />_ 8" PRECAST LINTEL OVER ALL <br />OPENINGS IN WALL (TYP) <br />STRUCK JOINT PAINTED <br />BLOCK WALLS ON INTERIOR <br />OF EACH SIDE <br />#5VERTICAL REBAR FROM FOOTINGS TO TOP <br />OF WALL AT LOCATIONS SHOWN ON FLOOR AND <br />FOUNDATION PLAN TIED TO ALL REBAR IN LINTEL. <br />AND FOOTINGS. POUR CELL SOLID WITH 3000 PSI <br />CONCRETE. ALL REBAR LAP TO BE MINIMUM 25" <br />4" 3000 PSI CONCRETE OVER CLEAN COMPACT <br />TERMITE TREATED SOIL. COVER WITH 6 MILL <br />VISQUEEN AND USE 6/610/10 WIRE MESH <br />16"X12" 3000 PSI CONCRETE FOOTING <br />WITH WITH 245 REBAR ON CHAIRS <br />�6" <br />WALL SECTION DETAIL S-3 <br />NOT TO SCALE <br />00 <br />r <br />0 <br />z <br />w <br />w <br />Q <br />C9 <br />ARKAY ENGINEERING INC. <br />STRUCTURAL ENGINEERS <br />RICHARD L. KIDDEY P.E. <br />FLORIDA LICENSE NUMBER 37296 <br />I HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS <br />WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION <br />ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 OF THE <br />FLORIDA BUILDING CODE 2010 AND ASCE 7-10 FOR 137 MPH <br />WIND ZONE RISK CATEGORY II <br />W <br />Q <br />a <br />z <br />O <br />W <br />} <br />r � � <br />m <br />cfl <br />cq <br />M�gtJ <br />z1L L <br />IJ_ so <br />z c do <br />Z Q) <br />�e 0 1 <br />lu >L Q p E ui <br />41 t! Q- <br />2 O UM <br />3 tM <br />UJ � ca <br />jhatoa <br />d' <br />M <br />V_ <br />m <br />Nr <br />•- <br />A <br />g <br />Z <br />`- <br />Z <br />m <br />a <br />o <br />0 <br />I— <br />J <br />U <br />U— <br />2 <br />cn <br />O <br />T� <br />i <br />` v / <br />W <br />DC <br />^= <br />W <br />N � <br />Q <br />Q <br />I— <br />U n. <br />W <br />Z <br />Z <br />r� <br />V <br />TOTAL AREA <br />176 SQ. FT. <br />WALL SECTION DETAIL S-1 <br />NOT TO SCALE <br />NOT TO SCALE <br />S1 <br />ARKAY # <br />