Laserfiche WebLink
TANKLESS WATER <br />HEATER LOCATION <br />HEATER LOCATION <br />ELECTRICAL PLAN 1 /411 = 1' of <br />100 AMP 24 CIR TYPICAL PANEL <br />1 <br />WALL PACK LIGHT/ TIMER <br />1 P20 <br />2 <br />STORAGE LIGHTS <br />1 P20 <br />3 <br />RESTROOM LIGHTS & FAN <br />1 P20 <br />4 <br />INSTANT HOT WATER / LAV <br />1 P20 <br />5 <br />INSTANT HOT WATER / MOP SK <br />1 P20 <br />6 <br />GFI RECEPTACLE <br />1 P20 <br />7 <br />EMERGENCY LIGHTS <br />1P20 <br />8 <br />SPACE <br />9 <br />SPACE <br />10 <br />SPACE <br />11 <br />SPACE <br />12 <br />SPACE <br />13 <br />SPACE <br />14 <br />SPACE <br />15 <br />SPACE <br />16 <br />SPACE <br />17 <br />SPACE <br />18 <br />SPACE <br />19 <br />SPACE <br />20 <br />SPACE <br />21 <br />SPACE <br />22 <br />SPACE <br />23 <br />SPACE <br />24 <br />SPACE <br />LOAD CALCULATIONS <br />LOAD <br />DEMAND FACTOR <br />TOTALS <br />LIGHTING <br />176 X 3 <br />528 <br />RECPTS <br />1 X 180 <br />180 <br />TANKLESS <br />WATER HEATERS <br />2 @ 360 <br />720 <br />TOTAL <br />1428 <br />1428 VA <br />208 VOLTS 6.9 AMPS <br />ELECTRICAL NOTES <br />1. All work to be done in accordance with all current national and <br />local codes and ordinances. <br />2. Notify Engineer of any discrepancies between these drawings and the <br />actual field conditions. Obtain clarifications from the Engineer or <br />Owners prior to commencing work. <br />3. Contractor will visit site prior to bidding, no allowances for any <br />extra expenses will be granted as a result of not visiting site. <br />4. Wire to be THHN/THWN Copper, min. size 14 AWG, unless shown otherwise. <br />5. RACEWAYS: RIGID STEEL CONDUIT: full weight galvanized threaded pipe, <br />EMT CONDUIT: compression fittings, PVC: schedule 40, all as allowed <br />by local codes. Separate raceways shall be used for each voltage system. <br />6. Any installation conflict with other trades shall be brought to the <br />attention of the Engineer for clarification before proceeding. <br />7. Contractor will verify location of equipment and connect as required for <br />clearances and connections. <br />8. All ourdoor electrical equipment to be NEMA 3R rated. <br />LIGHTING & ELECTRICAL LEGEND <br />A <br />& <br />O <br />LITHONIA LB 1OX48 2 LAMP <br />110V GROUND <br />BOSCH GL 5 <br />WRAP FLUORESCENT FIXTURE <br />FAULT OUTLET <br />ARISTON 2 1/2 <br />GALLON TANKLESS <br />WATER HEATER <br />BI <br />120V 1500 WATTS <br />HE <br />LITHONIA MNSB 132 L T6 <br />2 LAMP FLUORESCENT <br />100 CFM <br />FIXTURE <br />NUTONE 765 HL <br />EXHAUST FAN <br />O <br />PANEL <br />$MS <br />MOTION OCCUPANCY <br />SENSOR SWITCH <br />STANDARD SWITCH <br />METER <br />m <br />EMERGENCY LIGHT <br />LITHONIA TWAC <br />WITH BATTERY B.U. <br />MINI WALL PACK <br />3- #3 THNN <br />1- k3 N <br />G FOOTER STEEL <br />CONCRETE ENCASED"UFER" <br />ELECTRODE REQUIRED PER <br />CURRENT N.E.C. AND MUST <br />BE INSPECTED PRIOR TO <br />CONCRETE PLACEMENT <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE <br />SINGLE PHASE <br />BREAKER PANEL <br />MAIN <br />GROUND ROD <br />54" MIN TOILET 18" MIN 18" MIN —24" MIN <br />PAPER <br />F <br />1/ <br />HOLDER <br />42" MIN <br />: <br />LAY i <br />1 <br />z <br />CLEAR FLOOR <br />yj <br />SPACE <br />HANDICAP TOILET DETAIL ----- <br />--- <br />60" MIN <br />GRAB BARS <br />A GRAB BAR SHALL BE PROVIDE, LOCATED 33" INCHES <br />FROM AND PARALLEL TO THE FINISHED FLOOR. MEASURED <br />VERTICALLY TO THE TOP OF THE RAIL WITH VARIATION OF <br />NOT MORE THAN 1/2 INCH AND: <br />I, SHALL HAVE AN OUTSIDE DIAMETER OF 1 V2 INCHES <br />2. SHALL PROVIDE 1 112 INCHES OF CLEARANCE BETWEEN <br />THE RAIL AND THE WALL <br />3. SHALL BE SO DESIGNED AND SUPPORTED AS TO WITHSTAND <br />A LOAD OF NOT LESS THAN 250 LBS APPLIED AT ANY POINT, <br />DOWNWARD OR HORIZONTALLY. <br />4. SHALL BE CONTINUOUSLY GRASPABLE ALONG THE ENTIRE <br />LENGTH. <br />SPECIAL NOTE: GRAB BAR MEETING THE APPLICABLE ANSI STANDARDS <br />ARE DEEMED TO BE IN COMPLIANCE WITH THE INTENT OF <br />THE LAW WHETHER CENTER SUPPORTS EXIST OR NOT. <br />S. SHALL BE AT LEAST 42 INCHES LONG AND SHALL BE CENTERED <br />AT THE LEADING EDGE OF THE WATER CLOSET. <br />------------- ---- <br />6" MAX, ----'-- XX <br />TOE CLEARANCE i z Q <br />I <br />I I I <br />I I <br />I I <br />I I <br />rt" MAX LAV DEPTH B" MIN KNEE CLEARANCE <br />HANDICAP SINK DETAIL <br />SINK <br />1. SINK SHALL BE MOUNTED WITH THE COUNTER OR RIM <br />NO HIGHER THAN 34" FROM THE FINISH FLOOR. EACH <br />SINK SHALL BE MINIMUM OF 6 1/2" DEEP, <br />2, CLEAR FLOOR SPACE RESTROOMS SHALL HAVE AN <br />UNOBSTRUCTED SPACE OF AT LEAST 60" IN DIAMETER <br />OR 52" BY Yl" FINISH INSIDE DIMENSIONS ADJACENT TO <br />THE LAVATORY AREA, SUCH CLEAR FLOOR SPACE SHALL <br />ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE AND SHALL <br />EXTEND A MAXIMUM OF 13" UNDERNEATH THE LAVATORY <br />OR SNK <br />PLUMBING FIXTURE SCHEDULE <br />SLOAN OPTIMA FAUCET ETF-80 <br />LAVATORY <br />KOHLER MODEL K-2030-0 WHITE <br />CHROME FINISH <br />SUPPLY AND DRAIN PIPING TO <br />HAVE TAMPER PROOF SHIELD <br />UNDER SINK <br />BOSCH GLS ARISTON 2 1/2 <br />TO BE INSTALLED IN STORAGE <br />TANKLESS <br />GALLON <br />AREA BEHIND LAVATORY <br />WATER HEATER <br />WATER CLOSET <br />KOHLER MODEL K-4368-0 <br />SLOAN MANUAL <br />FLOOR MOUNT ADA <br />FLUSHOMETER 110 <br />SLOAN ROYAL EXPOSED <br />URINAL <br />KOHLER MODEL K-4904-ET-0 <br />FLUSHOMETER MODEL 180 <br />WALL MOUNT VERITEK <br />CHROME FAUCET TO FIT <br />MOP SINK <br />SOLID MOLDED TUB <br />TUB WITH WATER HOSE <br />MANUFACTURE TO BE <br />ADAPTER <br />DETERMINED <br />ELECTRICAL SPECIFICATIONS <br />1.1 SCOPE <br />A. WORK INCLUDED: Include the following Work in addition to items normally part of this Section: <br />01 Wiring for lighting and power. <br />02 Installation of lighting fixtures with lamps. <br />03 Lighting panelboards and distribution panelboards. <br />04 Connection of equipment shown. <br />05 Control wiring. <br />06 Disconnection and removal of existing fixtures and wiring not to be reused. <br />1.2 MINIMUM COMPLIANCE STANDARDS <br />A. All work shall be done in accordance with the requirements of the following: <br />01 Latest adopted issue of the National Electrical Code, NFPA 70. <br />02 Other applicable NFPA Codes. <br />03 Regulation of local authorities having jurisdiction. <br />B. Furnish and install all labor, material and equipment and services necessary for complete and <br />safe installation of the electrical system indicated on the drawings and noted in the <br />specifications hereinafter. Electrical systems and equipment shall in general include the <br />following: <br />01 General provisions for electrical work. <br />02 Wiring, distribution equipment and devices. <br />03 Lighting fixtures and lamps. <br />04 Grounding system. <br />1.3 GENERAL PROVISIONS FOR ELECTRICAL WORK <br />A. DRAWINGS: Electrical drawings considered diagrammatic and indicate general arrangement of work <br />and systems. Refer to other drawings to verify location of equipment, etc. Check drawings of <br />other trades to verify exact space condition or underground lines. Drawing Scales prohibit the <br />indication of all offsets, fittings and accessories required, however these items will be <br />provided by this subcontractor at no extra cost to the owner. <br />B. QUALITY OF MATERIALS: New, best of their respective kind, free from defects, and listed by <br />Underwriter's Laboratories, Inc. or bearing their label. <br />C. SHOP DRAWINGS: Submit four (4) copies of shop drawings for lighting fixtures and panelboards. <br />Obtain approval before equipment is ordered, built or installed. <br />D. EXCAVATION AND BACKFILLING: Excavate, backfill and restore surfaces for all electrical work. <br />E. Visit site and inspect existing facilities before bid in order to ensure proper evaluation of <br />working conditions and location of existing equipment. <br />1.4 WIRING, DISTRIBUTION EQUIPMENT AND DEVICES <br />A. CONDUCTORS: Copper, in accordance with ASTM Standards, size references AWG. Conductors No. 10 and <br />smaller size solid, No. 8 and larger stranded. Insulation of conductor thermoplastic, type THHN <br />(min. size: No. 12) any wire installed outside, underground, in slabs, or exposed to moisture <br />shall have THWN insulation. <br />B. RACEWAYS: RIGID STEEL CONDUIT, full weight pipe galvanized, threaded, and minimum 112 inch except <br />as noted or required for wiring. ELECTRICAL METALLIC TUBING (EMT), thin wall pipe, galvanized, threadless, <br />comression fittings, and minimum 1/2" except as noted or required for wiring. FLEXIBLE STEEL CONDUIT, <br />continuous singlestrip, galvanized, and minimum 1/2" size except as noted or required for wiring. PVC <br />CONDUIT, heavy duty type, size as indicated. Type AC or MC cable where permitted. Separate raceways shall <br />be used for each voltage system. <br />C. DISCONNECT SWITCHES: General Duty, horsepower rated for motor loads 600 or 250 volt rating, fused <br />or non -fused as noted; number of poles as indicated, cover Interlocked with switch. Enclosure <br />NEMA 1 for indoor use and NEMA 3R for weatherproof applications. Switch to be Square "D" or equal. <br />E <br />ALL WATER AND SANITARY PIPING TO <br />BE EXPOSED AND ACCESSIBLE FROM <br />THIS SIDE OF MASONRY WALL <br />SANITARY PLAN 1 /411 = 1' 0' <br />PIPE NOTE: <br />SANITARY PIPING TO BE SCHL 40 PVC <br />COLD AND HOT WATER LINES TO BE CPVC <br />OR EQUAL <br />D. CIRCUIT BREAKERS: Molded case, thermal -magnetic quick -make, quick -break, bolt -on type with <br />manually operated insulated trip -free handle. Multi -pole types with internal common trip bar. <br />Terminals suitable for copper or aluminum conductors. Interrupting capacity minimum 10,000 RMS <br />symmetrical amperes circuit breakers to be Square "D" or equal, type as required. <br />E. PANELBOARDS: Voltage, phasing and ampere ratings as indicated, circuit breaker type as indicated, <br />busbars of hard drawn copper, minimum 98% conductivity, galvanized steel back box, door and trim. <br />All corners lapped and welded, hardware chrome plated with flush lock and catch. Hinges semi - <br />concealed, 5 knuckle steel with nonferrous pins, 180 degree openings. Minimum gutter space 5- <br />3/4" sides, top and bottom. Increase size where required by code. Directory holder complete <br />with clear plastic transparent cover indicating typewritten list of feeder cables, conduit sizes, <br />circuit numbers, outlets of equipment supplied, and their location. Circuit breaker type <br />panelboards to be Square "D" type NQOD or I -Line, or equal. A plastic label shall be located on exterior of <br />panelboard identifying the system voltage, phase, and current rating. <br />F. WIRING DEVICES: All devices the product of the same manufacturer. Wall switches singlepole, 20 <br />ampere, 120 volt. Wall switches three-way, 20 ampere, 120 volt. Receptacles duplex, 2-wire; 3 <br />pole grounded, 20 ampere, 120 volt. <br />G. DEVICE PLATES: Provide for all outlets where devices are installed. Provide engraved marking for <br />special outlets. Provide blank plates for empty or future outlet boxes. DEVICE AND DEVICE PLATES <br />COLORS TO BE VERIFIED WITH INTERIOR DESIGNER AND OWNER. <br />1.5 LIGHTING FIXTURES AND LAMPS <br />A. Furnish and install complete system of lighting fixtures, lamps, accessories and supports as <br />specified and indicated. Submittals of equal quality are allowed. <br />1.6 GROUNDING SYSTEM <br />A. EQUIPMENT: Ground non -current carrying metal parts of panelboard, raceways and all lighting <br />fixtures. All conduits shall have equipment grounding conductors. <br />1.7 INSTALLATION <br />A. Secure all supports to building structure. Support horizontal runs <br />of metallic conduit not more than 10 feet apart. Run exposed raceways parallel with or at right <br />angles to walls. <br />B. Pass raceways over water, steam or other piping when pull boxes are not required. No raceway <br />within 3 inches of steam or hot water pipes, or appliances, except crossings where raceway shall <br />be at least 2 inches from pipe cover. <br />C. Cut conduit ends square, ream smooth. Paint male threads of field threaded conduit with graphite <br />base pipe compound. Draw up tight with conduit couplings. <br />D. Leave wire sufficiently long to permit making final connections. In raceways over 50 feet in <br />which wiring is not installed, furnish pull wire. <br />E. Verify locations of outlets and switches. <br />F. Support panel, junction and pull boxes independently to building structure with no weight bearing <br />on conduits. <br />G. Connect conduit to motor conduit terminal boxes with flexible conduit; minimum 18 inches in <br />length and 50% slack. Do not terminate in or fasten raceways to motor foundation. <br />H. Contractor to remove and salvage all abandoned electrical equiment. <br />I. This contractor shall warrant all labor and materials for one year from date of final written <br />acceptance. <br />ARKAY ENGINEERING INC. <br />STRUCTURAL ENGINEERS <br />RICHARD L. KIDDEY P.E. <br />FLORIDA LICENSE NUMBER 37296 <br />1 HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS <br />WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION <br />ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 OF THE <br />FLORIDA BUILDING CODE 2010 AND ASCE 7-10 FOR 137 MPH <br />WIND ZONE RISK CATEGORY II <br />Z� <br />z <br />0" <br />z <br />V1 <br />W <br />A <br />C <br />r- <br />1 <br />Comm <br />Cq to* <br />o� <br />ma�iii <br />Z <br />IL X L J <br />IL as <br />z c <br />_o <br />0FL <br />z�>JJJ <br />LJ <br />01T <br />go <br />w ILL <br />"_J <br />1i_ ) <br />W <br />d <br />0 <br />z <br />O <br />W <br />W <br />W <br />co <br />CV <br />N <br />� <br />�CC <br />m <br />r <br />G <br />Z <br />w <br />~ <br />O <br />Z <br />m <br />p <br />p <br />O <br />i' <br />J <br />U <br />Q <br />U. <br />2 <br />Ct) O <br />O <br />cl) <br />= UJ <br />N <br />LL Q <br />Oa <br />L) <br />LU <br />Z <br />Z <br />/D <br />V <br />TOTAL AREA <br />176 SQ. FT. <br />E1 P1 <br />ARKAY # <br />