Laserfiche WebLink
GENERAL NOTES: <br />THIS BUILDING HAS BEEN DESIGNED TO CONFORM TO THE 2010 FLORIDA BUILDING CODE <br />ARKAY ENGINEERING, INC.; A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL <br />ENGINEERING COMPANY; HAS APPLIED "RATIONAL ANALYSIS" FOR THE STRUCTURAL DESIGN <br />OF THIS STRUCTURE. <br />THE BUILDING ( INCLUDING ALL COMPONENTS AND CLADDINGS) SHALL BE DESIGNED FOR THE <br />FOLLOWING SUPERIMPOSED LOADS: <br />FLOORS: <br />LIVE LOAD - 50 P.S.F. <br />DEAD LOAD - 10 P.S.F. <br />ROOF: <br />LIVE LOAD ( TRUSS TOP CHORD) - 20 P.S.F. <br />DEAD LOAD ( TRUSS TOP CHORD) - 10 P.S.F. <br />DEAD LOAD ( TRUSS BOTTOM CHORD) - 10 P.S.F. <br />ASSUMED TRUSS SELF WEIGHT ( DEAD LOAD) - 7 P.S.F. <br />WIND: <br />BUILDING IS DESIGNED TO CONFORM TO ASC:E 7-10, CHAPTERS 28 THRU 31; PER 2010 FLORIDA <br />BUILDING CODE SECTION 1609.1.1. <br />COMPONENT & CLADDING WIND LOADS <br />WIND DESIGN ASSUMPTIONS: <br />BUILDING EXPOSURE - B <br />BUILDING RISK CATEGORY - II <br />MEAN ROOF HEIGHT 30' OR LESS <br />HEIGHT & EXPOSURE ADJUSTMENT <br />COEFFICIENT = 1.0 <br />ENCLOSED BUILDING <br />INTERNAL PRESSURE COEFFICIENT = +/- 0.18 <br />WIND SPEED SHOWN AT THE BOTTOM RIGHT <br />CORNER OF THIS SHEET <br />ALL STRUCTURAL ELEMENTS, EXTERIOR <br />WALLS AND INTERIOR WALLS SHALL BE <br />TYPE V CONSTRUCTION PER FBC 602.5 <br />ALL OTHER <br />BUILDING <br />ROOF OVERHANG <br />COMPONENT <br />ZONE <br />LOADS <br />LOADS <br />1 <br />N/A <br />+32.3/-35.3 <br />2 <br />-65.7 <br />+32.3/-56.2 <br />3 <br />-110.6 <br />+32.3/-89.0 <br />4 <br />N/A <br />+35.3/-38.2 <br />5 <br />N/A <br />+35.3/-47.2 <br />SOIL BEARING & COMPACTION: <br />THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE SOIL BEARING CAPACITY OF 2,000 P.S.F. <br />(MINIMUM) . THE CONTRACTOR/PROPERTY OWNER ARE RESPONSIBLE FOR VERIFYING THAT THE SOIL <br />ON THE SITE IS PROPERLY PREPARED & COMPACTED SUCH THAT IT CAN SUPPORT A 2,000 P.S.F. <br />FOUNDATION LOADING. <br />ARKAY ENGINEERING, INC.; A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL <br />ENGINEERING COMPANY; DESIGNED THESE FOUNDATIONS WITHOUT VISITING THE CONSTRUCTION SITE <br />NOR PERFORMING ANY SOIL TESTING. <br />ARKAY ENGINEERING, INC. SHALL NOT BE RESPONISIBLE FOR THE SITE SOILS ABILITY TO SUPPORT <br />THE BUILDING LOADS. <br />FOUNDATIONS & SLAB -ON -GRADE: <br />BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATERIALS WITHIN THE BUILDING AREA.' <br />ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AREA, SHALL BE COMPACTED <br />SUCH THAT IT CAN ADEQUATELY SUPPORT A 2,000 P.S.F. FOUNDATION LOADING. <br />SLAB SHALL BE PLACED OVER A 6 MIL VAPOR BARRIER ON CLEAN, ADEQUATELY <br />COMPACTED AND TERMITE POISONED SOIL. <br />CONCRETE UTILIZED IN THE FOUNDATIONS AND SLABS SHALL HAVE A MINIMUM 28 DAY <br />COMPRESSIVE STRENGTH OF 2,500 P.S.I. <br />REINFORCING STEEL SHALL BE.GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE <br />WITH ASTM A-615. LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25" <br />FOR #5 REBAR, 30" FOR #6 REBAR & 35" FOR #7 REBAR. <br />PLANS ARE ENGINEERED FOR A MAXIMUM STEMWALL HEIGHT OF 4 COURSES ( AFTER <br />FINAL SITE GRADING) . THE CONTRACTOR OR BUILDING OWNER SHALL DETERMINE THE <br />EXACT STEMWALL HEIGHT BASED UPON SITE CONDITIONS PRIOR TO POURING THE FOUNDATION <br />AND CONTACT ARKAY ENGINEERING WHEN MORE THAN 4 COURSES ARE REQUIRED. <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON THE <br />SITE FOR THE BUILDING INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND <br />A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY THE REQUIRED BUILDING SETBACKS. <br />1/2" CDX ROOF SHEATHING NAILED PER ROOF <br />SHEATHING DETAIL WITH 8D RS NAILS. COVER <br />WITH #30 FELT. INSTALL MASTER RIB 26 GA <br />PAINTED STEEL ROOFING OR EQUAL AS PER <br />MANUFACTURES SPECIFICATIONS <br />SECURE ALL ROOF TRUSSES TO BLOCK WALLS <br />USING SIMPSON HETA20 TRUSS STRAPS, FILL <br />NAIL HOLES WITH 10DX 1 1/2' NAILS <br />TOP OF BLOCK WALL 8' 4" <br />I <br />V 4" 2' 0" <br />2X4 WOOD SUB FASCIA WITH OVERHANG CANTILEVER <br />ALUMINUM FASCIA, DRIP AND <br />VINYL SOFFIT MATERIALS <br />NO INSULATION IN WALLS <br />0 <br />ao <br />STRUCK JOINT PAINTED <br />BLOCK WALLS ON EXTERIOR <br />BUILDING FINISH FLOOR 0' <br />c <br />APPROXIMATE FINAL GRADE <br />0 <br />BOTTOM OF FOOTING <br />SOIL TERMITE TREATMENT: PER FBC 2304.11 ' <br />TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING PESTICIDES <br />APPLIED TO SOIL, OR WOOD, BAITING SYSTEMS, OR OTHER APPROVED PROTECTION LABELED FOR <br />USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. <br />A "CERTIFICATE OF COMPLIANCE" SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED <br />PEST CONTROL COMPANY BEFORE A "CERTIFICATE OF OCCUPANCY" WILL BE ISSUED. THE CERTIFICATE <br />SHALL STATE <br />"THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA <br />DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." <br />INITIAL SOIL POISONING TREATMENT SHALL BE DONE AFTER ALL EXCAVATION, <br />BACKFILLING & COMPACTION ARE COMPLETE <br />ANY SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RE -TREATED <br />( INCLUDING ANY BOXED OR FORMED AREAS) - <br />BOXED AREAS IN THE CONCRETE SLAB FOR INSTALLATION OF TRAPS SHALL BE MADE <br />WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF AN <br />ADEQUATE SIZE & DEPTH TO ELIMINATE ANY DISTURBANCE OF THE SOIL AFTER THE <br />INITIAL TREATMENT. <br />A MINIMUM 6 MIL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL <br />DILUTION. IF RAINFALL OCCURS BEFORE VAPOR BARRIER PLACEMENT, RE -TREATMENT <br />SHALL BE REQUIRED <br />ANY CONCRETE OVERPOUR, MORTAR OR STUCCO MATERIALS ALONG THE FOUNDATION PERIMETER <br />MUST BE REMOVED PRIOR TO EXTERIOR SOIL TREATMENT <br />EXTERIOR SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />WITHIN 12 INCHES OF THE STRUCTURE SIDE WALLS <br />AN EXTERIOR VERTICAL CHEMICAL BARRIER SHALL BE INSTALLED AFTER CONSTRUCTION IS <br />COMPLETE ( INCLUDING LANDSCAPING AND IRRIGATION . ANY SOILS DISTURBED AFTER THE <br />VERTICAL BARRIER IS APPLIED, SHALL BE RE -TREATED. <br />CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 12 INCHES AWAY FROM THE <br />BUILDING SIDEWALLS <br />AFTER ALL WORK IS COMPLETED, ANY LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW <br />AND WITHIN 12 INCHES OF THE BUILDING. THIS SHALL INCLUDE ALL GRADE STAKES, TUB TRAP BOXES <br />FORMS, SHORING AND ANY OTHER CELLULOSE CONTAINING MATERIALS. <br />THE DISTANCE FROM THE EXTERIOR WALL COVERING ( EXCEPTIONS: PAINT AND DECORATIVE <br />CEMENTITIOUS FINISHES LESS THAN 5/8 INCH THICK ADHERED DIRECTLY ONTO THE FOUNDATION <br />WALL) AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6 INCHES TO ALLOW FOR INSPECTION <br />FOR FUTURE TERMITE INFESTATIONS <br />EXTERIOR WINDOWS & DOOR ASSEMBLIES: <br />ALL EXTERIOR WINDOW & GLASS DOORS SHALL BE TESTED IN ACCORDANCE WITH ANSI/AMMA/NWWDA <br />101/IS2 STANDARDS AND BEAR AN AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER, <br />PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY. <br />ALL MULLIONS AND ADJACENT DOORMINDOW ASSEMBLIES SHALL BE TESTED OR ENGINEERED TO <br />TRANSFER 1.5 TIMES THE DESIGN LOADS TO THE ROUGH OPENING SUBSTRATE. <br />INSTALL ALL WINDOW & DOOR ASSEMBLIES PER THE MANUFACTURERS ANCHORING RECOMMENDATIONS <br />TO ACHEIVE THE DESIGN PRESSURES SPECIFIED. <br />SAFETY GLAZING: <br />THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSES OF <br />GLAZING PER THE FLORIDA BUILDING CODE, RESIDENTIAL - <br />( 1) GLAZING IN SWINGING DOORS, FIXED AND SLIDING PANELS OF SLIDING DOOR <br />ASSEMBLIES. <br />() GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM <br />ROOMS, BATHTUBS, AND SHOWERS. GLAZING IN ANY PORTION OF A BUILDING WALL <br />ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS <br />THAN 60 INCHES ABOVE THE DRAIN INLET. <br />(3) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT A DOOR WHERE <br />THE NEAREST VERTICAL EDGE IS WITHIN A 24 INCH RADIUS OF THE DOOR IN A <br />CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE <br />FINISHED FLOOR OR WALKING SURFACE. <br />(4) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS <br />DESCRIBED IN ITEMS (Z AND (3) ABOVE. THAT MEETS ALL OF THE FOLLOWING <br />CONDITIONS: <br />A) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQ. FT. <br />B) BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR. <br />C) TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR. <br />D) ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE <br />PLANE OF THE GLAZING. <br />ENGINEERED ROOF TRUSSES <br />NO INSULATION IN ATTIC <br />4X8 JAMES HARDI 8" VERTICAL GROOVE <br />SHEETS APPLIED TO BOTTOM OF ROOF <br />TRUSSES WITH 8D NAILS 8" OC (TYP) <br />SINGLE COARSE KNOCK OUT LINTEL <br />BLOCK COARSE AT TOP OF WALL WITH <br />145 HORIZONTAL REBAR TIED TO ALL <br />VERTICAL RODS, POUR SOLID WITH <br />3000 PSI CONCRETE <br />_8" PRECAST LINTEL OVER ALL <br />OPENINGS IN WALL (TYP) <br />STRUCK JOINT PAINTED <br />BLOCK WALLS ON INTERIOR <br />#5VERTICAL REBAR FROM FOOTINGS TO TOP <br />OF WALL AT LOCATIONS SHOWN ON FLOOR AND <br />FOUNDATION PLAN TIED TO ALL REBAR IN LINTEL. <br />AND FOOTINGS. POUR CELL SOLID WITH 3000 PSI <br />CONCRETE. ALL REBAR LAP TO BE MINIMUM 25" <br />4" 3000 PSI CONCRETE OVER CLEAN COMPACT <br />TERMITE TREATED SOIL. COVER WITH 6 MILL <br />VISQUEEN AND USE 6/6 10/10 WIRE MESH <br />\ 16"X12" 3000 PSI CONCRETE FOOTING <br />WITH WITH 2-0 REBAR ON CHAIRS <br />WALL SECTION DETAIL S-1 <br />NOT TO SCALE <br />USE 1 SIMPSON HETA20 STRAP AT ONE <br />SIDE OF ALL ROOF TRUSSES AT BLOCK 12' 0" 2'0" 24" CANTILEVER ROOF LINE <br />WALL. FILL NAIL HOLES WITH 10DX 1/2" <br />NAILS. <br />r <br />r �x <br />ENGINEERED ROOF TRUSS PLAN 1/4" = 1101 <br />1 <br />1/2" CDX ROOF SHEATHING NAILED PER ROOF <br />SHEATHING DETAIL WITH 8D RS NAILS. COVER <br />WITH #30 FELT.INSTALL MASTER RIB 26 GA <br />PAINTED STEEL ROOFING OR EQUAL AS PER <br />MANUFACTURES SPECIFICATIONS <br />SECURE ALL ROOF TRUSSES TO BLOCK WALLS <br />USING SIMPSON HETA20 TRUSS STRAPS, FILL <br />NAIL HOLES WITH 10DX 1 1/2' NAILS <br />0 <br />60 <br />TOP OF BLOCK WALL 8' 4" <br />I <br />1, 4„ <br />2X4 WOOD SUB FASCIA WITH OVERHANG <br />ALUMINUM FASCIA, DRIP AND <br />VINYL SOFFIT <br />NO INSULATION IN WALLS <br />STRUCK JOINT PAINTED <br />BLOCK WALLS ON EXTERIOR <br />BUILDING FINISH FLOOF <br />0 <br />BOTTOM OF FOOTING <br />2x4 CROSS -BRACING @ RIDGE <br />20'-0" MAX I7 <br />Lq <br />I <br />a <br />IN <br />lm_ <br />m <br />Ims <br />MR <br />SEE TRUSS SYSTEM ENGINEERING DRAWINGS FOR ANY ADDITIONAL <br />BRACING OR CROSS BRACING REQUIREMENTS <br />REQ. MINIMUM TRUSS BRACING <br />t ENGINEERED ROOF TRUSSES <br />NO INSULATION IN ATTIC <br />4X8 JAMES HARDI 6" VERTICAL GROOVE <br />SHEETS APPLIED TO BOTTOM OF ROOF <br />TRUSSES WITH 8D NAILS 8" OC (TYP) <br />SINGLE COARSE KNOCK OUT LINTEL <br />BLOCK COARSE AT TOP OF WALL WITH <br />1 #5 HORIZONTAL REBAR TIED TO ALL <br />VERTICAL RODS, POUR SOLID WITH <br />3000 PSI CONCRETE <br />8" PRECAST LINTEL OVER ALL <br />OPENINGS IN WALL (TYP) <br />\� STRUCK JOINT PAINTED <br />BLOCK WALLS ON INTERIOR <br />#5VERTICAL REBAR FROM FOOTINGS TO TOP <br />OF WALL AT LOCATIONS SHOWN ON FLOOR AND <br />FOUNDATION PLAN TIED TO ALL REBAR IN LINTEL. <br />AND FOOTINGS. POUR CELL SOLID WITH 3000 PSI <br />CONCRETE. ALL REBAR LAP TO BE MINIMUM 25" <br />4" 3000 PSI CONCRETE OVER CLEAN COMPACT <br />TERMITE TREATED SOIL. COVER WITH 6 MILL <br />VISQUEEN AND USE 6/6 10/10 WIRE MESH <br />16"X12" 3000 PSI CONCRETE FOOTING <br />WITH WITH 245 REBAR ON CHAIRS <br />1' 0" 6" <br />WALL SECTION DETAIL S-2 <br />NOT TO SCALE <br />#5 VERTICAL RODS FROM FOOTINGS BELOW TO <br />TOP OF WALL. PLACED AT ALL CORNERS, EACH — <br />SIDE OF ALL OPENINGS AND SPACED MAXIMUM <br />4'0"OC <br />TOP/BOTTOM CHORD GABLE <br />END BRACING @ 48" O.C. MAX <br />FOR THE FIRST 4 ROWS OF <br />TRUSSES ( MIN 2X4) <br />W <br />-1 <br />m <br />Q <br />0 <br />CONT. BOTTOM CHORD <br />BRACING (1"x4" MIN.) @ <br />1 U-0" MAX. <br />O <br />in <br />W <br />O <br />W <br />LL <br />O <br />w <br />5'-0" <br />12' 0" 5' 0" <br />s- <br />r - - - -■r ----- ------- - - <br />li it li S iI M <br />li it li II <br />li �I li Ih i ■ O <br />■ I LI II II <br />■ I i 3' 4" 1,14, ih <br />I I I I I ib <br />I� �I I� �I■ iN <br />I ll �I II r <br />I I I 4" CONCRETE <br />I SIDEWALK <br />■I I I I J <br />L■ I I - — — — — — ■■ <br />1 - <br />11 •----------------------, b <br />l II <br />l l ifl <br />� s- I <br />I� II <br />1 1 <br />II l <br />— •— — —� — — — — -- — — — -' ■ - <br />S- <br />FOUNDATION PLAN 1/4" = 1' 0' <br />NOTE: <br />SEE SANITARY PLAN FOR PLUMBING <br />FIXTURE LOCATIONS <br />ROOFEDGE <br />3 O Q <br />O <br />ti�A O O <br />Oc� <br />O O O O _IRIDGE 0)2 1 <br />U) O <br />O� in <br />��Q L <br />O O 2 <br />2 O O <br />3 � O O O O O O <br />ip <br />O <br />Z <br />W <br />LU <br />J <br />m <br />Q <br />O <br />0 <br />ED <br />C <br />O <br />GABLE END <br />PARTIAL ROOF PLAN <br />ZONE O 8dRING SHANK NAILS AT 6" O.C. AT EDGES <br />8dRING SHANK NAILS AT 12" O.C. INTERMEDIATE <br />ZONES 2O O3 8dRING SHANK NAILS AT 6" O.C., 4" O.C. AT <br />ROOF EDGES, RIDGE LINE, OR GABLE ENDWALL <br />NOTE: END JOINTS FOR SHEATHING SHALL BE STAGGERED <br />AND OCCUR OVER A FRAMING MEMBER. <br />ROOF SHEATHING NAILING <br />NOT TO SCALE <br />ENGINEERED ROOF TRUSSES <br />NO INSULATION IN ATTIC <br />4X8 JAMES HARDI 8" VERTICAL GROOVE <br />SHEETS APPLIED TO BOTTOM OF ROOF <br />TRUSSES WITH 8D NAILS 8" OC (TYP) <br />SINGLE COARSE KNOCK OUT LINTEL <br />BLOCK COARSE AT TOP OF WALL WITH <br />1-#5 HORIZONTAL REBAR TIED TO ALL <br />VERTICAL RODS, POUR SOLID WITH <br />3000 PSI CONCRETE <br />8" PRECAST LINTEL OVER ALL <br />OPENINGS IN WALL (TYP) <br />STRUCK JOINT PAINTED <br />BLOCK WALLS ON INTERIOR <br />OF EACH SIDE <br />#5VERTICAL REBAR FROM FOOTINGS TO TOP <br />OF WALL AT LOCATIONS SHOWN ON FLOOR AND <br />FOUNDATION PLAN TIED TO ALL REBAR IN LINTEL. <br />AND FOOTINGS. POUR CELL SOLID WITH 3000 PSI <br />CONCRETE. ALL REBAR LAP TO BE MINIMUM 25" <br />4" 3000 PSI CONCRETE OVER CLEAN COMPACT <br />TERMITE TREATED SOIL. COVER WITH 6 MILL <br />VISQUEEN AND USE 6/6 10110 WIRE MESH <br />__\_L <br />16"X12" 3000 PSI CONCRETE FOOTING <br />WITH WITH 245 REBAR ON CHAIRS <br />WALL SECTION DETAIL S'3 <br />NOT TO SCALE <br />ARKAY ENGINEERING INC. <br />STRUCTURAL ENGINEERS <br />�c�`i 3 <br />RfCHARD L. K.Ii D E Y <br />' <br />FLORIDA LICENSE NUM3ER ?7296 <br />I HERBY CERTIFY Ti AT E PLANS AND SPECIFICATIONS <br />WERE PREPARED BY ME OR UNDER ".iY DIRECT SUPERVISION <br />ARE IN COMPLIANCE WI'rH CHAPTER 16, SECTION 1609 OF THE <br />FLORIDA BUILDING CODE 2010 AND ASCE 7-10 FOR 137 MPH <br />WIND ZONE RISK CATEGORY ii <br />Zu <br />z <br />0" <br />Ln � <br />z <br />0.0 <br />A <br />Q <br />Z <br />U) <br />W <br />M <br />N <br />(D <br />CV <br />M <br />r <br />Z <br />FW— <br />0 0 <br />Z <br />m <br />0 <br />U <br />LL <br />2 <br />� O <br />3: 'I—^ <br />` BUJ <br />2 1.,1.. <br />W � <br />N Q <br />O Z <br />W <br />Z <br />Z <br />rD <br />V <br />TOTAL AREA I <br />152 SQ. FT. <br />S1 <br />ARKAY # I`wb°Z� <br />TII�1'iT: IT. I i I TAJ1 1..:m Id7-. CAI 11L..ldi•1 �7R11111 111,.. _l 11 N:..,L � ..1 <br />