LOW VOL
<br />FOR LAV
<br />FAUCET
<br />HEATER LOCATION
<br />ELECTRI(."P4AL PLAN 1 /411 = 1' 0'
<br />100 AMP 24 CIR TYPICAL PANEL
<br />1
<br />WALL PACK LIGHT/ TIMER
<br />1 P20
<br />2
<br />1 STORAGE LIGHTS
<br />1 P20
<br />3
<br />RESTROOM LIGHTS & FAN
<br />1 P20
<br />4
<br />INSTANT HOT WATER / LAV
<br />1 P20
<br />5
<br />INSTANT HOT WATER / MOP SK
<br />1 P20
<br />6
<br />GFI RECEPTACLE
<br />1 P20
<br />7
<br />EMERGENCY LIGHTS
<br />1P20
<br />8
<br />SPACE
<br />9
<br />SPACE
<br />10
<br />SPACE
<br />11
<br />SPACE
<br />121
<br />SPACE
<br />13
<br />SPACE
<br />14
<br />SPACE
<br />15
<br />SPACE
<br />16
<br />SPACE
<br />17
<br />SPACE
<br />18
<br />SPACE
<br />19
<br />SPACE
<br />20
<br />SPACE
<br />21
<br />SPACE
<br />22
<br />SPACE
<br />23
<br />SPACE
<br />24
<br />SPACE
<br />LOAD CALCULATIONS
<br />LOAD
<br />DEMAND FACTOR
<br />TOTALS
<br />LIGHTING
<br />152 X 3
<br />456
<br />RECPTS
<br />1 X 180
<br />180
<br />TANKLESS
<br />WATER HEATERS
<br />1 @ 360
<br />360
<br />TOTAL
<br />996
<br />996 VA
<br />208 VOLTS = 4.8 AMPS
<br />ELECTRICAL NOTES
<br />1. All work to be done in accordance with all current national and
<br />local Codes and ordinances.
<br />2. Notify Engineer of any discrepancies between these drawings and the
<br />actual field conditions. Obtain clarifications from the Engineer or
<br />Owners prior to commencing work.
<br />3. Contractor will visit site prior to bidding, no allowances for any
<br />extra expenses will be granted as a result of not visiting site.
<br />4. Wire to be THHN/THWN Copper, min. size 14 AWG, unless shown otherwise.
<br />5. RACEWAYS: RIGID STEEL CONDUIT: full weight galvanized threaded pipe,
<br />EMT CONDUIT: compression fittings, PVC: schedule 40, all as allowed
<br />by local codes. Seperate raceways shall be used for each voltage system.
<br />6. Any installation conflict with other trades shall be brought to the
<br />attention of the Engineer for clarification before proceeding.
<br />7. Contractor will verify location of equipment and connect as required for
<br />clearances and connections.
<br />8. All ourdoor electrical equipment to be NEMA 3R rated.
<br />LIGHTING & ELECTRICAL LEGEND
<br />A
<br />bon
<br />(�
<br />ED
<br />LITHONIA LB 10X48 2 LAMP
<br />110V GROUND
<br />BOSCH GL 5
<br />WRAP FLUORESCENT FIXTURE
<br />FAULT OUTLET
<br />ARISTON 2 1/2
<br />GALLON TANKLESS
<br />WATER HEATER
<br />BI
<br />120V 1500 WATTS
<br />LITHONIA MNSB 1 32 L T8
<br />2 LAMP FLUORESCENT
<br />100 OFM
<br />FIXTURE -
<br />NUTONE 766 HL
<br />- EXHAUSTFAN
<br />O
<br />PANEL
<br />$MS
<br />MOTION OCCUPANCY
<br />SENSOR SWITCH
<br />STANDARD SWITCH
<br />METER
<br />�yy--��
<br />0=
<br />EMERGENCY LIGHT
<br />LITHONIA TWAC
<br />WITH BATTERY B.U.
<br />MINI WALL PACK
<br />3- #3 THNN
<br />1-#3 N
<br />SINGLE PHASE
<br />BREAKER PANEL
<br />MAIN
<br />1-#e G FOOTER STEEL - GROUND ROD
<br />CONCRETE ENCASED "UFER"
<br />ELECTRODE REQUIRED PER -
<br />CURRENT N.E.C. AND MUST
<br />BE INSPECTED PRIOR TO
<br />CONCRETE PLACEMENT
<br />ELECTRICAL RISER DIAGRAM
<br />NOT TO SCALE
<br />54" MIN TOILET is" MIN
<br />PAPER
<br />HOLDER
<br />42' MIN
<br />o ri
<br />m
<br />in
<br />HANDICAP TOILET DETAIL
<br />F11MIN MIN
<br />I,, I.
<br />LAY i
<br />f
<br />'
<br />z
<br />CLEAR FLOOR '
<br />SPACE
<br />--------------
<br />60" MIN
<br />GRAB BARS
<br />A GRAB BAR SHALL BE PROVIDE. LOCATED 33" INCHES
<br />FROM AND PARALLEL TO THE FINISHED FLOOR. MEASURED -
<br />VERTICALLY TO THE TOP OF THE RAIL WITH VARIATION OF
<br />NOT MORE THAN 1/2 INCH AND,
<br />I. SHALL HAVE AN OUTSIDE DIAMETER OF 1 1/2 INCHES
<br />2. SHALL PROVIDE 1 1/2 INCHES OF CLEARANCE BETWEEN
<br />THE RAIL AND THE WALL.
<br />3,
<br />SHALL BE 60 DESIGNED AND SUPPORTED AS TO WITHSTAND
<br />A LOAD OF NOT LESS THAN 290 LBO APPLIED AT ANY POINT.
<br />DOWNWARD OR HORIZONTALLY.
<br />4, SHALL, BE CONTINUOUSLY GRASPABLE ALONG THE ENTIRE
<br />LENGTH.
<br />SPECIAL NOTE, GRAB BAR MEETING THE APPLICABLE ANSI STANDARDS
<br />ARE DEEMED TO BE IN COMPLIANCE WITH THE INTENT OF
<br />THE LAW WHETHER CENTER SUPPORTS EXIST OR NOT,
<br />S. SHALL. BE AT LEAST 42 INCHES LONG AND SHALL BE CENTERED
<br />AT THE LEADING EDGE OF THE WATER CLOSET,
<br />-------------------
<br />6" MAX, X
<br />TOE CLEARANCE-
<br />� L �
<br />., Z g
<br />air q A
<br />11' MAX LAV DEPTH O" MIN KNEE CLEARANCE
<br />HANDICAP SINK DETAIL-
<br />SINK
<br />1. SINK SHALL BE MOUNTED WITH THE COUNTER OR RIM
<br />NO HIGHER THAN 34" FROM THE FINISH FLOOR, EACH
<br />SINK SHALL BE MINIMUM OF 6 1/2' DEEP,
<br />2. CLEAR FLOOR SPACE RESTROOMS SHALL HAVE AN
<br />UNOBSTRUCTED SPACE OF AT LEAST 60" IN DIAMETER
<br />OR 5Y BY 12" FINISH INSIDE DIMENSIONS ADJACENT TO
<br />THE LAVATORY AREA, SUCH CLEAR FLOOR SPACE SHALL
<br />ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE AND SHALL
<br />EMEND A MAXIMUM OF IS" UNDERNEATH THE LAVATORY
<br />OR SINK
<br />PLUMBING FIXTURE SCHEDULE
<br />SLOAN OPTIMA FAUCET ETF-600
<br />LAVATORY
<br />KOHLER MODEL K-2030-0 WHITE
<br />CHROME FINISH
<br />SUPPLY AND DRAIN PIPING TO
<br />HAVE TAMPER PROOF SHIELD
<br />UNDER SINK
<br />BOSCH GLS ARISTON 2 1/2
<br />TO BE INSTALLED IN STORAGE
<br />TANKLESS
<br />GALLON
<br />AREA BEHIND LAVATORY
<br />WATER HEATER
<br />WATER CLOSET
<br />KOHLER MODEL K-4368-0
<br />SLOAN MANUAL
<br />FLOOR MOUNT ADA
<br />FLUSHOMETER 110
<br />WALL MOUNT VERITEK
<br />CHROME FAUCET TO FIT
<br />MOP SINK
<br />SOLID MOLDED TUB
<br />TUB WITH WATER HOSE
<br />MANUFACTURE TO BE
<br />ADAPTER
<br />DETERMINED
<br />1
<br />ALL WATER AND SANITARY PIPING TO
<br />BE EXPOSED AND ACCESSIBLE FROM
<br />THIS SIDE OF MASONRY WALL
<br />SANITARY PLAN 1 /411= 1' 0'
<br />PIPE NOTE:
<br />SANITARY PIPING TO BE SCHL 40 PVC
<br />COLD AND HOT WATER LINES TO BE CPVC
<br />OR EQUAL
<br />ELECTRICAL SPECIFICATIONS
<br />1.1 SCOPE D. CIRCUIT BREAKERS: Molded case, thermal -magnetic quick -make, quick -break, bolt -on type with
<br />A. WORK INCLUDED: Include the following Work in addition to items normally part of this Section: manually operated insulated trip -free handle. Multi -pole types with internal common trip bar.
<br />01 Wiring for lighting and power. Terminals suitable for copper or aluminum conductors. Interrupting capacity minimum 10,000 RMS
<br />02 Installation of lighting fixtures with lamps. symmetrical amperes circuit breakers to be Square "D" or equal, type as required.
<br />03 Lighting panelboards and distribution panelboards.
<br />04 Connection of equipment shown. E. PANELBOARDS: Voltage, phasing and ampere ratings as indicated, circuit breaker type as indicated,
<br />05 Control wiring. busbars of hard drawn copper, minimum 98% conductivity, galvanized steel back box, door and trim.
<br />06 Disconnection and removal of existing fixtures and wiring not to be reused. All corners lapped and welded, hardware chrome plated with flush lock and catch. Hinges semi-
<br />1.2 MINIMUM COMPLIANCE STANDARDS concealed, 5 knuckle steel with nonferrous pins, 180 degree openings. Minimum gutter space 5-
<br />A. All work shall be done in accordance with the requirements of the following: 3/4" sides, top and bottom. Increase size where required by code. Directory holder complete
<br />with clear plastic transparent cover indicating typewritten list of feeder cables, conduit sizes,
<br />01 Latest adopted issue of the National Electrical Code, NFPA 70. circuit numbers, outlets of equipment supplied, and their location. Circuit breaker type
<br />02 Other applicable NFPA Codes. panelboards to be Square "D" type NQOD or I -Line, or equal. A plastic label shall be located on exterior of
<br />03 Regulation of local authorities having jurisdiction. anelboard identifying the system voltage, phase, and current rating.
<br />B. Furnish and install all labor, material and equipment and services necessary for complete and p 9 y g ' p g'
<br />safe installation of the electrical system indicated on the drawings and noted in the F. WIRING DEVICES: All devices the product of the same manufacturer. Wall switches single pole, 20
<br />specifications hereinafter. Electrical systems and equipment shall in general include the ampere, 120 volt. Wall switches three-way, 20 ampere, 120 volt. Receptacles duplex, 2 wire; 3
<br />following: pole grounded, 20 ampere, 120 volt.
<br />01 General provisions for electrical work.
<br />02 Wiring, distribution equipment and devices. G. DEVICE PLATES: Provide for all outlets where devices are installed. Provide engraved marking for
<br />03 Lighting fixtures and lamps. special outlets. Provide blank plates for empty or future outlet boxes. DEVICE AND DEVICE PLATES
<br />04 Grounding system. COLORS TO BE VERIFIED WITH INTERIOR DESIGNER AND OWNER.
<br />1.3 GENERAL PROVISIONS FOR ELECTRICAL WORK 1.5 LIGHTING FIXTURES AND LAMPS
<br />A. DRAWINGS: Electrical drawings considered diagrammatic and indicate general arrangement of work A. Furnish and install complete system of lighting fixtures, lamps, accessories and supports as
<br />and systems. Refer to other drawings to verify location of equipment, etc. Check drawings of specified and indicated. Submittals of equal quality are allowed.
<br />other trades to verify exact space condition or underground lines. Drawing Scales prohibit the 1.6 GROUNDING SYSTEM
<br />indication of all offsets, fittings and accessories required, however these items will be
<br />provided by this subcontractor at no extra cost to the owner. A. EQUIPMENT: Ground non -current carrying metal parts of panelboard, raceways and all lighting
<br />B. QUALITY OF MATERIALS: New, best of their respective kind, free from defects, and listed by fixtures. All conduits shall have equipment grounding conductors.
<br />Underwriter's Laboratories, Inc. or bearing their label.
<br />C. SHOP DRAWINGS: Submit four (4) copies of shop drawings for lighting fixtures and panelboards. 1.7 INSTALLATION
<br />Obtain approval before equipment is ordered, built or installed. A. Secure all supports to building structure. Support horizontal runs
<br />D. EXCAVATION AND BACKFILLING: Excavate, backfill and restore surfaces for all electrical work. of metallic conduit not more than 10 feet apart. Run exposed raceways parallel with or at right
<br />E. Visit site and inspect existing facilities before bid in order to ensure proper evaluation of angles to walls.
<br />working conditions and location of existing equipment. B. Pass raceways over water, steam or other piping when pull boxes are not required. No raceway
<br />within 3 inches of steam or hot water pipes, or appliances, except crossings where raceway shall
<br />1.4 WIRING, DISTRIBUTION EQUIPMENT AND DEVICES be at least 2 inches from pipe cover.
<br />A. CONDUCTORS: Copper, in accordance with ASTM Standards, size references AWG. Conductors No. 10 and C. Cut conduit ends square, ream smooth. Paint male threads of field threaded conduit with graphite
<br />smaller size solid, No. 8 and larger stranded. Insulation of conductor thermoplastic, type THHN base pipe compound. Draw up tight with conduit couplings.
<br />(min. size: No. 12) any wire installed outside, underground, in slabs, or exposed to moisture D. Leave wire sufficiently long to permit making final connections. In raceways over 50 feet in
<br />shall have THWN insulation. which wiring is not installed, furnish pull wire.
<br />B. RACEWAYS: RIGID STEEL CONDUIT, full weight pipe galvanized, threaded, and minimum 1/2 inch except E. Verify locations of outlets and switches. ARKAY ENGINEERING INC.
<br />as noted or required for wiring. ELECTRICAL METALLIC TUBING (EMT), thin wall pipe, galvanized, threadless, F. Support panel, junction and pull boxes independently to building structure with no weight bearing STRUCTURAL ENGINEERS
<br />comression fittings, and minimum 1/2" except as noted or required for wiring. FLEXIBLE STEEL CONDUIT, on conduits.
<br />continuous singlestrip, galvanized, and minimum 1/2" size except as noted or required for wiring. PVC G. Connect conduit to motor conduit terminal boxes with flexible conduit; minimum 18 inches in f
<br />CONDUIT, heavy duty type, size as indicated. Type AC or MC cable where permitted. Separate raceways shall length and 50% slack. Do not terminate in or fasten raceways to motor foundation.
<br />be used for each voltage system. H. Contractor to remove and salvage all abandoned electrical equiment.
<br />I. This contractor shall warrant all labor and materials for one year from date of final written I t �
<br />C. DISCONNECT SWITCHES: General Duty, horsepower rated for motor loads 600 or 250 volt rating, fused acceptance. R;CHARD L. KIDOEY P.:_..
<br />or non -fused as noted; number of poles as indicated, cover interlocked with switch. Enclosure p /FLORIDA LICENSE NUMBER 37296
<br />T THF-.ND SPECIFICATIONS
<br />NEMA 1 for indoor use and NEMA 3R for weatherproof applications. Switch to be Square "D" or equal. WEE EBPRE AR'!1:i' ED B/ME ,S'UE',' DE.RLMA DIRECT SUPERVISION
<br />ARE IN COMPLIANCE WITH 0I f FTER 16, SECTION 1609 OF THE
<br />FLORIDA BUILDING CODE 2010 AND ASCE 7-10 FOR 137 MPH
<br />WIND ZONE RISK CATEGORY 11
<br />cm
<br />01
<br />� d
<br />a o
<br />LL
<br />O
<br />N
<br />s � �
<br />W M
<br />Q
<br />1
<br />IL LL
<br />mF
<br />LD
<br />L u�
<br />W
<br />� V
<br />co
<br />r
<br />Iti A %0
<br />McAN�
<br />11
<br />I!- L
<br />Z
<br />L
<br />U_ so
<br />�
<br />J m
<br />Z
<br />ul
<br />ip�ul
<br />4 )
<br />!Y
<br />(%Y�gt
<br />W S)
<br />Ld 8) 0
<br />1-1814s
<br />CZ
<br />Hsu
<br />W
<br />Q
<br />Z
<br />0
<br />W
<br />W
<br />CY
<br />N
<br />}-
<br />04
<br />M
<br />Z
<br />p
<br />w
<br />~
<br />p
<br />o
<br />Z
<br />m
<br />O
<br />I—
<br />J
<br />U
<br />U.
<br />O
<br />U)
<br />W
<br />� Y
<br />W �
<br />N Q
<br />LL �
<br />O
<br />U �
<br />W
<br />Z
<br />Z
<br />D
<br />0
<br />TOTAL AREA
<br />152 SQ. FT.
<br />E'� P 1
<br />ARKAY # 1+143