Laserfiche WebLink
■ <br />A00 SITE PLAN —GENERAL NOTES. 1"xAv1L,tjLv kja W, ALL tlt:ruvG NINI LMs "V LLMl'fffr1U1Ns YKLUK T °bWVJ lvG. <br />F s�� FAILURE TO DO 90 SHALL NOT RELIEVE CONTRACTORS FROM PERFORMING THE <br />/Sol. AO1. .PROPOSED FLOOR PLAN /DEMO PLAN . WORK UNDER THIS CONTRACT. REPORT, IN WRITING ANY VARYING FIELD <br />A02 . ELEVATIONS— FRO N T/SIDE. CONDITIONS, OMMITIONS, OR DISCREPANCIES TO THE CONSULTANT. INCLUDE IN <br />kR BID ANY ADDITIONAL WORK REQUIRED FOR CODE COMPLIANCE. <br />_ � A03 . SECTIONS—CRr*OSS/LONGITUDINAL. L AP4ED 3) SHOULD ANY ERROR, OMMITION, DISCREPANCY BE ENCOUNTERED DURING ` <br />140—.00 (P)��� <br />CONSTRUCTION, THE CONSULTANT SHALL BE NOTIFIED PROMPTLY, SO THAT HE <br />o , <br />E01 ELECTRICAL PLAN <br />Q t ISC' r P,&TM L3 MAY HAVE THE OPPERTUMTY TO TAKE WHATEVER STEPS NECESSARY TO <br />8� v coo(REFLECTED CEILING PLAN). EQ� _ RESOLVE THE PROBLEM. <br />cm <br />o _ <br />co ELECTRICAL POWER PLAN . 4) ACTION TAKEN WITHOUT KNOWLEDGE OF CONSULTANT OR IN CONTRADICTION <br />ss - io.00'(p) y6. N„Q' EO2 . TO THE WORK PRODUCT OR THE RECOMMENDATIONS TO THE CONSULTANT SHALL <br />A' 0.& oo S'A Ro c <br />E03. ELECTRICAL PANEL PLAN. BECOME THE RESPONSIBILITY OF SUCH PARTIES TAKING ACTION. <br />Ro• v N86002'03"E 140.00' P&M S,� , /� EQUIPMENT PLAN. 5) THE GENERAL CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND <br />�°i,q�D e• N - /- SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION MEANS,METFIODS . TECHNIQUES. <br />4 o / P01 P L V M B I N G PLAN . SEQUENCES AND PROCEDURES: AS PART OF HIS RESPONSIBILITY, THE <br />CONTRACTOR SHALL RETAIN THE SERVICES OF A LICENSED STRUCTURAL <br />b <br />- M01 MECHANICAL PLAN <br />277s ENGINEER TO DESIGN AMEND, SUPERVISE ANY SCAFFOLDING FOR WORKMAN <br />�' �'p�./G01. GENERAL NOTES DU DETAILS. <br />d , <br />N N t t .70' , ; . _ - o- 0 i� -- AND ALL SHORING OF FORMS AND ELEMENTS OF CONSTRUCTION. <br />cn <br />a c �. / �► / �! 6) PROVIDE ALL NECESARY SHORING BRACING TEMPORARY PROTECTION, ETC. AS <br />�i' ._ . , ..:�__._.:.: .._ ....: _ REQUI <br />RED. THE GENERAL CONTRACTOR AT HIS EXPENSE SHALL ENGAGE <br />o • ' . ° w i PROPERLY QUALIFIED PERSONS TO DETERMINE WHERE AND HOW TEMPORARY <br />27 >> = 9 ro� STORE/BUILDING IN FORMATION/DIMENSIONS:�US SHALL BE USED A INSPECT S IN T E D. <br />. <br />a N_ _ ' � + �� AND THE SAME H FIELD. ANY <br />/-, <br />0 3osa' 60.26' ' o s ; OBSERVATION BY THE FIELD REPRESENTATIVE (CONSULTANT OR ENGINEER) <br />liftv w�' SEATING AREA: SHALL NOT INCLUDE THE INSPECTION OF THIS ITEMS. <br />IO 4b �' ��' ( COUNTER AREA: g 23'H' 7) PROVIDE ALL MATERIAL AND SKII,LED LABOUR AS REQUIRED FOR A COMPLETE <br />N �o�Ip�.}_' Q QN�j�� N W �i� /_ <br />i FINISH INSTALLATION. VARIFY EXTENT OF OWNER PARTICIPATION. <br />N �G � �► sl — \ %�. PREPARATION AREA: 2"7w �"' <br />o c, c 6 �/ _ -- 8) DO NOT SCALE DRAWINGS DIMENSIONS OR TAKE PRECEDENCE. VAR ALL <br />.: �.� oj; KITCHEN AREA: DIMESIONS ON , <br />v 26.98' 30.54 s0:96 <br />SITE. <br />_ 2�.os . r� �' _ OFFICE/S TORA,GEIRE5TROOM/UTILIlI(: �55�' , ' <br />/ 2, S68.00'00-W 140:Ot?� P s �, - ( `; f 9)CLEAN JOBSITE AFTER EACH DAY WORK MAINTAIN A CLEAN SAFE JOBSITE AT <br />/ aoE 139.97 (M) oco�o o I4 Ap ALL TIME. <br />oN�� Ss• 3i4 , TOTAL SIZE: ; ti 2.71 X. 6f,9 gD') ��' <br />Rom 10) THE GENERAL CONTRACTOR AND SUBCONTRACTOR WILL ASSUME FULL <br />s• o os f T _ 140.00'(P) _ `- TOTAL AREA:t 7 f) P�7C. I RESONSIBUM, UNRELIEVED BY THE REVIEW OF SHOP DRAWINGS AND <br />DOCUMENTS FOR DIMENSIONS,COORDINATION OF VARIOUS TRADES, <br />_._ 14d FABRICATION PROCESSES, CONSTRUCTION TECHNIQUES, AND SAFETY CONDITONS. <br />11) THE DESIGN MANUFACTURE AND INSTALLATION/ERECTION OF ALL <br />MANUFECTURED ITEMS INCLUDING BUT NOT LIMITED TO,PREFABRICATED METAL <br />i BUILDINGS, TRUSSERCURTAIN WALL SYSTEMS, ETC. AND THEIR CONNECTIONS TO <br />THE PRIMARY STRUCTURAL ELEMENTS SHALL BE PROMULGATED BY AND IN <br />ACCORDANCE WITH ALL APPLICABLE CODES, SPECIFICATIONS AND STANDARDS, <br />}�• o LOCAL ORDINANCES, AND / OR SPECIFIC CRITERIA NOTED ON THE DRAWINGS. THE <br />n <br />v . <br />COMPLIANCE OF THIS CONTINGENCES IS SOLELY THE RESPONSIBILITY OF THEIR <br />MANUFECTURER. <br />. � O <br />0 <br />0 <br />o C , <br />0 <br />O , <br />. 12) ALL MATERIALS SHALL BE FREE OF DEFECTS AND INSTALLED IN A <br />O PROFESSIONAL, WORKMANLIKE MANNER BY SKILLED MECHANICS. <br />�o . _ • ; 6e 13) ALL CONTRACTORS WORKING ON THIS PROJECT SHALL CARRY LIABILITY AND <br />PROPERTY DAMAGE INSURANCE WITH A HOLD HARM LESS CLAUSE TO <br />} t INDEMNIFY, DEFEND AND FOLD HARMLESS THE CONSULTANT AND THE OWNER <br />FROM AND AGAINST ANY AND ALL CLAIMS, COSTS, DAMAGES, EXPENCES, SUITS, <br />- - /(�� ( JUDJEMENTS,LIA.BILITIES, AND ATTORNEY'S FEES IN CONNECTION WITH THE <br />-i- D CLAIMS FOR INJURY OR DEATH TO PERSONS OR DAMAGE TO PROPERTY CAUSED <br />E ( BY OR ALLEGED TO BE CAUSED BY OR IN ANY MANNER DIRECTLY OR INDIRECTLY <br />,OZ �1',(� 4 `� ARISING FROM,INCIDENT TO ,CONNECTED WITH BY OR ALLEGED TO HAVING <br />CAUSED BY AN ACT, ERROR OR OMMITION, NEGLIGENCE OR OT14ERWISE OR <br />N PARTIES OR EITHER OR ANY OF THEM INDEMNIFIED. <br />Z—'n►�ter� 14) EACH AND EVERY CONTRACTOR AND SUB CONTRACTOR WHEN ACCEPTING <br />CONTRACTUAL <br />,� OBLIGATIONS FOR THIS PROJECT SHALL UNDERSTAND THAT A <br />v <br />PREREQUISITE TO ANY OPERATION OR PROJECT WHETHE;i FILED WITH OWNER OR <br />NOT, THAT THEY HAVE IMPLIED AGREEMENT TO THE ABOVE (NOTE 14 "HOLD <br />- 23 2D Iq C3 17 I,pl _ HARMLESS) AND ITS SPECIFIC WORDINGS. <br />f4ML Toes PJSc2W �� � 15) IT IS AGREED THAT THE PROFESSIONAL SERVICES OF A CONSULTANT DO NOT <br />Q INCLUDE THE REVIEW OF THE SITE OBSERVATION OF THE CONTRACTOR'S WORK <br />OR PERFORMANCE. CONSULTANT SHALL NOT BE RESPONSIBLE FOR CONSTRUCTION <br />df <br />P �•r <br />MANAGEMENT AND OR SUPERVISION. <br />E' El •T\ • 16) ALL LOCAL STATE AND FEDERALREGULATIONS <br />RE ULA ONS AND PROCEDURES REGARDING <br />i ALA' I �,` �a�a SAFETY ARE RESPONSIBILITY OF THE CONTRACTOR <br />`c7P"`^1-t+�' " - <br />17) ALL CONSTRUCTION TO BE NON COMBSTIBLE, I HOUR FIRE RATED MINIMUM <br />) s af4jA A�r � 1�2 vPC'cA-{. - <br />18) ALL FLOOR WALLS CEILINGS, PENETRATIONS TO COMPLY WITH REQUIRED <br />------ '� <br />� ., 14 FIRE RATINGS <br />h <br />EC IAL qAPETY NOTE: <br />� <br />�T <br />-- - - ALL CONTRACTOR AND THEIR WORKMAN WORKING ON THIS PROJECT SHALL AT <br />,ram ; <br />IIG:iii�kl111 • ;� 13 ALL TIMES ,PRIOR AND DURING T COURSE 0 ACTIVITY <br />URIHE URS N F THEIR ACTIVI BE RESONSIBLE <br />FOR THE SAFETY OF THEIR EMPLOYEES AS WELL AS OTHERS AND IN THE CARE OF <br />N Z�H'N ate! <br />THE PROPERTY. EACH REPRESENTATIVE OF THEIR EMPLOYEE SHALL ASCERTAIN <br />THAT THE CONDI TIO <br />' <br />=,--•- �� l N UNDER WHICH THEY WILL BE REQUIRED TO ACCOMPLISH <br />w.. THEIR WORK ARE SAFE WITHIN GOOD SAFETY PRACTICES AND MEET ALL <br />CONCERNED REGULATIONS OF THE OCCUPATIONAL SAFETY HAZARD ACT, OR <br />ti OTHER GOVERNING REGULATIONS.THE BEGINNING OF WORK BY A CONTRACTOR <br />�. SHALL INDICATE SATISFACTION CONCERNING SAFETY AND FULL RESPONSIBILITY <br />FOR ACCIDENTS OR DAMAGE. IF UNSATISFIED, THE CONTRACTOR SHALL INDICATE <br />WHAT SO EVER ACTION OR DEVICES NECESSARY TO RENDER SAFETY CONDITIONS <br />FOR LIFE AND PROPERTY AS ARE RELATED TO HIS ACTIVITY. IF THE WORK OF <br />414 gOTHER PARTIES OUTSIDE ORGANIZATION IS UPON INSPECTION IS FOUND AT ANY <br />HAVE PREPARED OR CAUSED TO BE PREPARED VNDER MY DI RECTSVPERVISION, <br />TIME TO BE UNSAFE, HE SMALL STOP WORK MMEDIATELY AND NOTIFY THE <br />THE ATTACHED PLANS AND SPECIFICATIONS AND STATE THAT, TO THE BEST OF MY ARCHITECT AND OWNER . <br />- KNOWLEDGEAND BELIEFAND TO THE EXTENT OF MY CONTRACTUAL DO NOT SCALE DRAWINGS. <br />�CLEPT' S'Fe_j Pi9oNce,', J!ECvCFAd—,OBLIGATIONS THEYARE IN COMPLIANCE WITH THE ENVIRONMENTAL BARRIERS FIELD DIMENSIONS ON THIS DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED <br />/Aojp> ACTAND FLORIDA ACCESSIBILITY CODE. DINENSIONS. <br />r� <br />t4 <br />SOUTHEAST DESIGN <br />INTERNATIONAL INC <br />2 15 1 SOUTHERN OAKS LANE <br />LAKELAND FL 33813-31 <br />863-409-6422 (CELL) <br />FAX: 863-644-6057 <br />DAZZLIN' DONUTS <br />TROMBO RENOVATIONS <br />5131 GALL BLVD, <br />ZEPHYRHILLS, FL 33542 <br />PmJoet Sheut No. <br />of ehcotu <br />Data ! — �D� DrnvrtugNo. <br />t;cnlo I p_ Id oil Ae00 <br />® w <br />_ <br />