My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5814 12th St
Zephyrhills
>
Building Department
>
Building Plans
>
5814 12th St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 8:21:59 AM
Creation date
2/19/2025 8:22:15 AM
Metadata
Fields
Template:
Building Plans
Street #
5814
Location
12th St
Contractor
Rudy & Kristi Dorcuee
Building Plans - Permit #
7543
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />-- ENGINEER'S NOTES <br />ALL WORK IS TO BE COMPLETED IN ACCORDANCE <br />WITH THE FLORIDA BUILDING CODE 2004 <br />SECTION R-301 ,ASCE 1-02, THE 2005 SUPPLEMENT <br />AND THE 2006 SUPPLEMENT. <br />1) THE BASIC DESIGN WIND SPEED = 120 MPH (3 SECOND GUST) <br />2) THE IMPORTANCE FACTOR = 1,0 l BUILDING CAT, lI RESIDENTIAL) <br />3) THE EXPOSURE CATEGORY = B <br />4) THE INTERNAL PRESSURE COEFFICIENT = +/- 0.18 (ENCLOSED) <br />5) THE COMPONENT AND CLADDING DESIGN PRESSURES <br />ARE PER THE FBC TABLE R301.2(2) FOR A BUILDING <br />WITH A MEAN ROOF HEIGHT OF LESS THAN 30'-0" EXPOSURE B. <br />10'-2° <br />DISTANCE FROM THE EXTERIOR <br />r —I-- WALL TO THE EXISITING RIDGE <br />20'-4" EXISTING HOUSE <br />FRONT ELEVATION <br />14'-0" NEW ADDITION <br />FOR GABLES OR HIP ROOFS VENTILATION SHALL BE <br />PROVIDED TO FURNISH CROSS VENTILATION OF EACH <br />SEPERATE ATTIC. THE RATIO OF TOTAL NET FREE <br />VENTILATING AREA TO THE AREA OF THE CEILING <br />SHALL BE NOT LESS THAN 1/150. <br />GLAZING <br />GLAZING THE FOLLOWING SHALL BE CONSIDERED SPECIFIC <br />HAZARDOUS LOCATION FOR THE PURPOSE OF- <br />01 GLAZING IN SWING DOORS, FIXED AND SLIDING PANEL OF <br />SLIDING DOORS ASSEMEBLIES. <br />02 GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, <br />WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATH TUBS AND <br />SHOWERS, GLAZING IN ANY PORTION OF A BUILDING WALL <br />ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE <br />OF THE GLAZING IS LESS THAN foO" ABOVE THE DRAIN INLET. <br />03 GLAZING IN INDIVIDUAL FIXED OR OPERABLE PANEL <br />ADJACENT A DOOR WHERE THE NEARBY VERTICAL EDGE IS <br />WITHIN A 24" RADIUS OF THE DOOR IN A CLOSED POSITION <br />AND WHOSE BOTTOM EDGE IS LESS THAN 60" ABOVE THE <br />FINISH FLOOR OR WALKING SURFACE. <br />04 GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL <br />OTHER THAN THOSE LOCATIONS DESCRIBED IN ITEMS (2) AND <br />(3) ABOVE, THAT MEETS ALL THE FOLLOWING <br />(A) EXPOSED AREA OF AN INDIVIDUAL PANEL OTHER THAN <br />THOSE LOCATIONS <br />(B) BOTTOM EDGE LESS THAN IS" ABOVE THE FLOOR <br />(G) TOP EDGE GREATER THAN 36" ABOVE THE FLOOR <br />(D) ONE OR MORE WALKING SURFACES WITHIN 36" <br />HORIZONTALLY OF THE PLANE OF THE GLAZING <br />REFER TO THE THE 2004 FLORIDA BUILDING CODE <br />RESIDENTIAL -SECTION R308 FOR ADDITONAL AREAS THAT <br />MAY BE CONSIDERED A HAZARDOUS LOCATION FOR THE <br />PURPOSE OF GLAZING <br />ROOF VENTING <br />ROOF <br />VENTING <br />ROOF <br />METAL <br />VENTING <br />ROOFING <br />ROOF <br />VENTING <br />ROOF VENTING <br />ROOF VENTING <br />ROOF VENTING <br />I <br />_ TEMPERED <br />w OBSCURE <br />o.El <br />EH <br />2 <br />-- - -- <br />- <br />Ld <br />LEI <br />LEI <br />hd <br />El <br />8'- 3If <br />A MIN OF 16" OF GROUND CLEARANCE <br />TO ANY UNTREATED WOOD. <br />ml on <br />65'-6" <br />RIGHT ELEVATION <br />r�jnv <br />.------------------------------_---_______--____---_-----------------_---------------__-----------_--__-___-_--_____ <br />3,45 / 12 +/- _ " <br />iZ-©q <br />ov- Ze ���� <br />i'UWS <br />NEW ADDITION -0" EXISTING HOUSE 14'-0" NEW ADDITION 20'-4" EXISTING HOUSE <br />34'-4" <br />LEFT ELEVATION <br />READ? ELEVATION <br />J N ij. I7 <br />1 o'`T <br />DATE : <br />2/Oro /08 <br />SCALE: <br />1/4 11 1' O" <br />R. 5. HANLEY <br />PAGE I <br />DESIGN SERVICES INC. <br />MOBILE/ OFFICE 352-206-5821 <br />OFFICE FAX 352-588-2342 <br />P 0 BOX 1325 SAN ANTONIO <br />FLA. 33516 <br />THE CLIENT UNDERSTANDS THE THE DESIGNER CARRIES <br />NO LIABILITY INSURANCE AND THEREFOR AGREES TO <br />HOLD HARMLESS, IDEMNIFY, AND DEFEND THE DESIGNER <br />FROM ALL CLAIMS, LOSSES AND EXPENSES( INCLUDING <br />ATTORNEYS FEES) ARISING OUT OF OR RESULTING FROM <br />THE PROJECT, THE DESIGNER IN GOOD FAITH ATTEMPT TO <br />PROVIDE ERROR FREE CONSTRUCTION DRAWINGS. <br />IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT <br />BE HELD LIABLE FOR THE COST OF THE REPAIRS OR <br />DELAY TO THE JOB, THE CONTRACTOR NEEDS TO VERIFY <br />AND UNDERSTAND ALL INFORMATION BEFORE BIDDING <br />OR STARTING ANY WORK ON THE JOB, <br />THE PLUMBING , ELECTRICAL AND MECHANICAL <br />PARTS OF THE PLAN ARE NON-STRUCTURAL AND <br />MAY BE ADJUSTED BY THE SUB -CONTRACTORS <br />PERMITTED TO DO THE JOB. BUT THE CHANGES <br />MUST MEET THE MINIMUM STANDARDS OF THE <br />CURRENT FLORIDA BUILDING CODE. THESE CHANGES <br />ARE NOT REQUIRED TO BE VERIFIED BY THE ENGINEER <br />OF RECORD FOR THIS PLAN. <br />SEE THE SIMPSON STRONG TIES CATALOG FOR ANY <br />ADDITIONAL INFORMATION ON ANY OF THE SIMP50N <br />FASTENERS SPECIFIED ON THIS PLAN. <br />CATALOG C-2008 EFFECTIVE 1/ 1/ 08 <br />BECAUSE THIS IS AN ADDITION IT WILL SE THE <br />RESPONSIBILITY OF ALL SUBS AND SUPPLIERS <br />TO VERIFY ALL INFORMATION IN THE FIELD <br />BEFORE ORDERING ANY MATERIAL OR STARTING <br />ANY WORK. THE HOMEOWNER REQUIRES THAT <br />THIS NEW ADDITION MATCHES THE EXISTNG HOUSE. <br />IF ANY INFORMATION IS NOT ON THIS PLAN THE <br />CONTRACTOR WILL NEED TO VERIFY THAT THE NEW <br />WORK IS MATCHING THE EXISTING. <br />RUD1' and KRISTI DOROUEE <br />5814 12th STREET <br />ZE10HYRHILLS, FLORIDA <br />EAST PASCO COUNTY <br />33542 <br />TOTAL NEW ADDITION <br />-15ro SF <br />DAVID UJ, SM,ITH, P.E. <br />FLORIDA LIC.* 53608 <br />352-521-0865 OFFICE 352-521-08roi FAX. <br />SSOS WALLASTON DRIVE DADE CITE' ,FLA. 33525 <br />I HEREBY CERTIFY THAT I HAVE REVIEWED THIS <br />PLAIN AND FOUND IT TO BE IN COMPLIANCE WITH <br />SECTION R-301 OF THE FLA. BUILDING CODE 2004 <br />ASCE "I - 02 , THE 2005 AND THE 200ro SUPPLEMENT. <br />THE WIND DESIGN PRESSURES ARE BASED ON <br />A 120 MPH ( 3 SECOND GUST) WIND ZONE. <br />DAVID W. SMITH PE * 53608 <br />
The URL can be used to link to this page
Your browser does not support the video tag.