Laserfiche WebLink
PAD "All <br />32"x32"Aro" 3000 PSI <br />CONCRETE PAD WITH <br />05 REBARS IN BOTH <br />DIRECTIONS AT 6" OC <br />TIED TO ROD CHAIRS <br />PAD 1115 <br />2411x24"x12" 3000 PSI <br />CONCRETE PAD WITH <br />05 RE3AR5 IN BOTH <br />DIRECTIONS AT (o" OC <br />TIED TO ROD CHAIRS <br />i <br />O O O O O O O O <br />1 <br />O O O O O 1 0 O O O <br />1 <br />O O O O 1 0 O O O <br />ALL WOOD HEADERS WILL BE LAPPED A MIN OF 48" <br />AND NAILED WITH 12d COMMONS AT 12" OC IN (3) ROWS <br />AND ON EACH SIDE OF ALL SPLICES. <br />WOODEN FLOOR BEAM DETAIL <br />NO PLYWOOD SPACERS REQUIRED <br />ALL FLOOR JOIST, ROOF RAFTERS, AND HEADERS <br />SHALL BE NO LESS THAN 02 SOUTHERN YELLOW PINE <br />LUMBER. IF THE LUMBER WILL BE IN THE WEATHER OR <br />CLOSER THAN 18" FROM THE GROUND IT WILL NEED <br />TO BE PRESSURE TREATED. EXCEPT AS NOTED, <br />NOVELTY PINE SIDING OVER <br />1/2" CDX OR OSB SHEATHING <br />SIMPSON SPi AND SP2 STUD <br />PLATE TIES AS PER THE <br />THE TRUSS LAYOUT UNLESS <br />OTHERWISE NOTED <br />(2) HT516 TRUSS STRAPS PER <br />EACH PIER FL538-123 <br />*5 REBAR IN FILLED CELLS IN H <br />8"x16" CONCRETE PIERS <br />GRADE <br />THE BOTTOM OF THE FOOTER <br />WILL BE A MIN DISTANCE OF 12" <br />INTO EXISTING GROUND <br />4 <br />i- <br />rl <br />m <br />O� <br />I <br />z <br />C4 <br />Lu <br />al d <br />�i <br />Q <br />I <br />I 1 I 1 <br />I A I I A , <br />1 I 1 1 <br />28'-b" <br />1 <br />8-0 I 8-O 8-O 8-O i 8-0 81-9 <br />1- - -�- - �- - - - - - - - - - - - - - f -� -� -rI ------------------- <br />-ELT: <br />A A A A A ;A ' <br />1 �-1 <br />4LL OF THE PIERS WILL BE <br />I u� <br />'OURED SOLID WITH 3000 ; 1-8 y I = <br />'Si CONCRETE AND HAVE ----- `--------- 1-- OI ' <br />05 REBAR IN ALL CELLS. <br />1 <br />5EE THE DETAILS FOR THE c <br />'AD SIZES. -- <br />3' <br />1 <br />1 , <br />1 <br />- ----- ;------------r-1�1� ------------ -----; IT1- r r----'-;-A <br />1 u I u I 1 n 1 a � 1 u 1 n 1 u � <br />8 -0 3 -S 4 -3 i 8 -O 8 -O Z -1 2 -8 <br />1 <br />1 <br />1 I <br />1 <br />1 <br />1 <br />1 <br />I <br />1=0UNDATION PLAN <br />TRIPLE 2x12 FLOOR BEAMS / NAILED WITH 12d COMMONS IN (3) <br />STAGGERED ROWS AT 12" OC MIN LAP OF 48" <br />EXISTING HOUSE <br />I <br />USE <br />SIMPSON NCA210-16 <br />- <br />I <br />BRIDGING FL414-121 <br />T <br />THE MID POINT OF THE <br />FLOOR JOISTS <br />DBL <br />2x12 <br />FLOOR <br />BEAM <br />- - <br />J <br />SAME <br />NAILING <br />PATTERN <br />I; <br />I <br />TRIPLE 2x12 FLOOR BEAMS / NAILED WITH 12d COMMONS IN (3) <br />STAGGERED ROWS AT 12" Or, MIN LAP OF 48" <br />28'-fo" <br />- - - -- <br />FLOOR JOIST FRAMING PLAN <br />3/4" STURDI FLOR T46 SHEATHING <br />GLUED AND NAILED TO THE FLOOR JOIST <br />2x10 FLOOR JOIST AT 16" OC <br />(2) SIMPSON HETA 12 EMBEDDED STRAPS <br />PER PIER TO ATTACH THE FLOOR BEAMS <br />TO THE CONCRETE PIERS. FLISOI-128 <br />FOUNDATION CROSS SECTION DETAIL <br />USE 5IMP50N LU28 <br />FACE MOUNTED U HANGERS <br />FL414-121 ON ALL JOIST TO <br />BEAM CONNECTIONS <br />-------------------- - - ----- <br />3'-ro I, 2'-8" <br />I <br />EXISTING HOUSE <br />FLOOR JOIST LOADINCs <br />40 PSF LIVE LOAD <br />10 PSF DEAD LOAD <br />360 DEFLECTION <br />MAX SPAN FOR 16" OC SPACING IS <br />W-1" WITH NO.2 GRADE 2x10 JOISTS <br />SOUTHERN YELLOW PINE <br />8'-9" <br />I <br />1 <br />1 <br />1 <br />1 <br />1 <br />I <br />I <br />1 <br />1 <br />I <br />I <br />1 <br />I <br />1 <br />1 <br />1 <br />Q <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />DATE : <br />2/Oro /08 <br />SCALE: �� PAGE <br />2 <br />1/4 = 1-O <br />DESIGN SERVICES INC. <br />MOBILE/ OFFICE 352-20(o-5821 <br />OFFICE FAX 352-588-2342 <br />RR' 8' HANLEY P 0 BOX 1325 SAN ANTONIO <br />�- --- -� FLA. 3351ro <br />THE CLIENT UNDERSTANDS THE THE DESIGNER CARRIES <br />NO LIABILITY INSURANCE AND THEREFOR AGREES TO <br />HOLD HARMLESS, IDEMNIFY, AND DEFEND THE DESIGNER <br />FROM ALL CLAIMS, LOSSES AND EXPENSES( INCLUDING <br />ATTORNEYS FEES) ARISING OUT OF OR RESULTING FROM <br />THE PROJECT. THE DESIGNER IN GOOD FAITH ATTEMPT TO <br />PROVIDE ERROR FREE CONSTRUCTION DRAWINGS. <br />IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT <br />BE HELD LIABLE FOR THE COST OF THE REPAIRS OR <br />DELAY TO THE JOB. THE CONTRACTOR NEEDS TO VERIFY <br />AND UNDERSTAND ALL INFORMATION BEFORE BIDDING <br />OR STARTING ANY WORK ON THE JOB. <br />THE PLUMBING, ELECTRICAL AND MECHANICAL <br />PARTS OF THE PLAN ARE NON-STRUCTURAL AND <br />MAY BE ADJUSTED BY THE SUB -CONTRACTORS <br />PERMITTED TO DO THE JOB. BUT THE CHANGES <br />MUST MEET THE MINIMUM STANDARDS OF THE <br />CURRENT FLORIDA BUILDING CODE. THESE CHANGES <br />ARE NOT REQUIRED TO BE VERIFIED BY THE ENGINEER <br />OF RECORD FOR THIS PLAN. <br />SEE THE SIMPSON STRONG TIES CATALOG FOR ANY <br />ADDITIONAL INFORMATION ON ANY OF THE SIMPSON <br />FASTENERS SPECIFIED ON THIS PLAN. <br />CATALOG C-2008 EFFECTIVE I/ 1/ 08 <br />BECAUSE THIS IS AN ADDITION IT WILL 15E THE <br />RESPONSIBILITY OF ALL SUBS AND SUPPLIERS <br />TO VERIFY ALL INFORMATION IN THE FIELD <br />BEFORE ORDERING ANY MATERIAL OR STARTING <br />ANY WORK. THE HOMEOWNER REQUIRES THAT <br />THIS NEW ADDITION MATCHES THE EXISTNG HOUSE. <br />IF ANY INFORMATION IS NOT ON THIS PLAN THE <br />CONTRACTOR WILL NEED TO VERIFY THAT THE NEW <br />WORK IS MATCHING THE EXISTING. <br />RUD1' and KRISTI DOROUEE <br />5014 12th STREET <br />ZEFHYRHILLS, FLORIDA <br />EAST PASCO COUNTY <br />33542 <br />TOTAL NEW ADDITION <br />15ro SF <br />DAVID W. SMITH, P.E. <br />FLORIDA LIC." 53608 <br />352-521-0865 OFFICE 352-521-086-I FAX. <br />9909 WALLASTON DRIVE DADE CITY ,FLA. 33525 <br />I HEREBY CERTIFY THAT I HAVE REVIEWED THIS <br />PLAN AND FOUND IT TO BE IN COMPLIANCE WITH <br />SECTION R-301 OF THE FLA. BUILDING CODE 2004 <br />ASCE -1 - 02, THE 2005 AND THE 200ro SUPPLEMENT. <br />THE WIND DESIGN PRESSURES ARE BASED ON <br />A 120 MPH ( 3 SECOND GUST) WIND ZONE. <br />DAYID W. SMITH PE 0 53608 <br />