FRAMING NOTES: <br />1) ALL WOOD USED FOR SOLE PLATES OR IN CONTACT <br />WITH SOIL WILL BE *2 PT SOUTHERN YELLOW PINE . <br />2) ALL INTERIOR AND EXTERIOR WALLS SHALL BE <br />*2 SPRUCE OR BETTER AND SPACED 16" OC, <br />3) ALL ENG. WOOD BEAMS SUCH AS PARALLAMS <br />HAVE BEEN DESIGNED ACCORDING TO THE <br />TRU65JOIST SPECIFICATIONS. <br />4) ALL OF THE SIMP50N FASTENERS AND HANGERS <br />MAY BE REPLACED WITH THOSE OF EQUAL OR GREATER <br />VALUES, ALWAYS VERIFY TINS WITH THE ENG, OF RECORD, <br />5) ALL ELECTRICALPLUMBING AND MECHANICAL ROUGH INS <br />MUST BE COMPLETED, INSPECTED AND APPROVED PRIOR <br />TO REQUESTING A FRAMING INSPECTION. <br />6) ALL INTERIOR DIMENSIONS ARE GIVEN TO THE INDICATED <br />CENTER OF THE STUD UNLESS NOTED OTHERWISE. <br />-1) ALL OF THE EXTERIOR DIMENSIONS ARE GIVEN TO THE <br />FACE OF THE FRAME OR MASONRY WALL WHICH WILL <br />ALIGN WITH THE FOUNDATION WALL BELOW. (FRAME <br />WALLS ARE HELD IN 1/2" TO ALIGN THE EXTERIOR <br />SHEATHING WITH THE FOUNDATION). <br />8) ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY <br />SHALL BE PRESSURE TREATED LUMBER. <br />9) ALL WOOD HEADERS ARE TO BE NO LESS THAN A DBL 2X6 <br />*2 SOUTHERN YELLOW PINE WITH A 1/2" SPACER, <br />GLAZING <br />GLAZING THE FOLLOWING SHALL BE CONSIDERED SPECIFIC <br />HAZARDOUS LOCATION FOR THE PURPOSE OF- <br />*1 GLAZING IN SWING DOORS, FIXED AND SLIDING PANEL OF <br />SLIDING DOORS ASSEMEBLIES, <br />02 GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, <br />WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATH TUBS AND <br />SHOWERS, GLAZING IN ANY PORTION OF A BUILDING WALL <br />ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE <br />OF THE GLAZING IS LESS THAN 60" ABOVE THE DRAIN INLET, <br />03 GLAZING IN INDIVIDUAL FIXED OR OPERABLE PANEL <br />ADJACENT A DOOR WHERE THE NEARBY VERTICAL EDGE IS <br />WITHIN A 24" RADIUS OF THE DOOR IN A CLOSED POSITION <br />AND WHOSE BOTTOM EDGE IS LESS THAN 60" ABOVE THE <br />FINISH FLOOR OR WALKING SURFACE, <br />04 GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL <br />OTHER THAN THOSE LOCATIONS DESCRIBED IN ITEMS (2) AND <br />(3) ABOVE. THAT MEETS ALL THE FOLLOWING <br />(A) EXPOSED AREA OF AN INDIVIDUAL PANEL OTHER THAN <br />THOSE LOCATIONS <br />(1=3) BOTTOM EDGE LESS THAN 18" ABOVE THE FLOOR <br />(C) TOP EDGE GREATER THAN 36" ABOVE THE FLOOR <br />(D) ONE OR MORE WALKING SURFACES WITHIN 36" <br />HORIZONTALLY OF THE PLANE OF THE GLAZING <br />REFER TO THE THE 2004 FLORIDA BUILDING CODE <br />RESIDENTIAL -SECTION R308 FOR ADDITONAL AREAS THAT <br />MAY BE CONSIDERED A HAZARDOUS LOCATION FOR THE <br />PURPOSE OF GLAZING <br />65'-6" <br />54'-2" I1'-4" - <br />3'-4 _�_ 6 -4 I 11-0 �, _ 15 -6 10 -6 �_- - - <br />SH 33/2 <br />TEMPERED 31+ 41- [30+ 33- 1 30+ 33- l <br />b135Gl1RE SH 25 5H 25 5H 25 — 5H 25 — 5H 25 <br />,ATTIC ACCESS <br />ATTIC ACCESS SHALL BE PROVIDED TO ATTIC AREAS <br />EXCEEDING 30 SQ,FT, AND HAVING MINIMUM 30 INCHES OF <br />VERTICAL HEIGHT. ROUGH FRAMED OPENINGS NOT TO BE <br />LESS THAT 2211X30" INCHES. WHEN MECHANICAL EQUIPMENT IS <br />LOCATED IN THE ATTIC IT SHALL BE INSTALLED IN <br />ACCORDANCE WITH 2O04 FLORIDA BUILDING GODS <br />RESIDENTIAL -SECTION M1305.1.3, <br />THE DESIGN WIND PRESSURE RATINGS ARE LISTED <br />FOR EACH OPENING.THE WINDOWS AND DOORS <br />CHOOSEN BY THE HOMEOWNER OR CONTRACTOR <br />WILL NEED TO MEET OR EXCEED THESE PRESSURES <br />LISTED BY EACH OPENING. ONLY WINDOWS AND <br />DOORS WITH A FLORIDA APPROVAL RATING M SHALL <br />BE USED. THIS MANUFACTURERS INFORMATION WILL <br />BE REQUIRED BEFORE ANY INSTALLATION OF THESE <br />PRODUCTS, <br />MAIN FLOOR PLAN <br />DATE : <br />2/Or /08 <br />SCALE: <br />1/4" = 1'-0" <br />R, S. HANLEY <br />PAGE 3 <br />DESIGN SERVICES INC, <br />MOBILE/ OFFICE 352-206-5521 <br />OFFICE FAX 352-588-2342 <br />P 0 BOX 1325 SAN ANTONIO <br />FLA. 3351ro <br />THE CLIENT UNDERSTANDS THE THE DESIGNER CARRIES <br />NO LIABILITY INSURANCE AND THEREFOR AGREES TO <br />HOLD HARMLESS, IDEMNIFY, AND DEFEND THE DESIGNER <br />FROM ALL CLAIMS, LOSSES AND EXPENSES( INCLUDING <br />ATTORNEYS FEES) ARISING OUT OF OR RESULTING FROM <br />THE PROJECT. THE DESIGNER IN GOOD FAITH ATTEMPT TO <br />PROVIDE ERROR FREE CONSTRUCTION DRAWINGS, <br />IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT <br />BE HELD LIABLE FOR THE COST OF THE REPAIRS OR <br />DELAY TO THE JOB, THE CONTRACTOR NEEDS TO VERIFY <br />AND UNDERSTAND ALL INFORMATION BEFORE BIDDING <br />OR STARTING ANY WORK ON THE JOB, <br />THE PLUMBING , ELECTRICAL AND MECHANICAL <br />PARTS OF THE PLAN ARE NON-STRUCTURAL AND <br />MAY BE ADJUSTED BY THE SUB -CONTRACTORS <br />PERMITTED TO DO THE JOB. BUT THE CHANGES <br />MUST MEET THE MINIMUM STANDARDS OF THE <br />i <br />CURRENT FLORIDA BUILDING CODE. THESE CHANGES <br />ARE NOT REQUIRED TO BE VERIFIED BY THE ENGINEER <br />OF RECORD FOR THIS PLAN. <br />SEE THE SIMPSON STRONG TIES CATALOG FOR ANY <br />ADDITIONAL INFORMATION ON ANY OF THE SIMP50N <br />FASTENERS SPECIFIED ON THIS PLAN. <br />CATALOG C-2008 EFFECTIVE I/ 1/ 08 <br />BECAUSE THIS IS AN ADDITION IT WILL BE THE <br />RESPONSIBILITY OF ALL SUBS AND SUPPLIERS <br />TO VERIFY ALL INFORMATION IN THE FIELD <br />BEFORE ORDERING ANY MATERIAL OR STARTING <br />ANY WORK. THE HOMEOWNER REQUIRES THAT <br />THIS NEW ADDITION MATCHES THE EXISTNG HOUSE. <br />IF ANY INFORMATION IS NOT ON THIS PLAN THE <br />CONTRACTOR WILL NEED TO VERIFY THAT THE NEW <br />WORK IS MATCHING THE EXISTING. <br />I <br />RUDY and fKR IST l IDOROUEE <br />5514 12th STREET <br />ZEFHYRHILLS, FLORIDA <br />EAST PASCO COUNTY <br />33542 <br />TOTAL NEW ADDITION <br />156 SF <br />DAVID W. SMITH, P.E. <br />FLORIDA LIC.0 53608 <br />352-521-0865 OFFICE <br />352-521-08(ol FAX. <br />9909 WALLASTON DRIVE DADE CITY ,FLA. 33525 <br />I HEREBY CERTIFY THAT I HAVE REVIEWED THIS <br />PLAN ,AND FOUND IT TO BE IN COMPLIANCE WITH <br />SECTION R-301 OF THE FLA. BUILDING CODE 2004 <br />ASCE i - 02 , THE 2005 ,AND THE 2006 SUPPLEMENT. <br />THE WIND DESIGN PRESSURES ARE BASED ON <br />A 120 MPH ( 3 SECOND GUST) WIND ZONE. <br />DAVID W. SMITH PE * 53608 <br />