AN ELECTRICAL CONTRACTOR WILL NEED TO <br />DETERMINE IF THE EXISTING HOUSE ELECTRIC <br />PANEL WILL NEED TO BE UPGRADED FOR THE <br />NEW ADDITION. <br />ELECTRICAL SYMBOLS <br />FAN /LIGHT COMBO <br />FAN <br />O RECESSED POT LIGHT <br />DBL FLOOD LIGHTS <br />EXHAUST FAN <br />$ SINGLE SWITCH <br />don GROUND FAULT OUTLET <br />LIGHT <br />$3 3-WAY SWITCH <br />SMOKE DETECTOR <br />110 OUTLET <br />CONCRETE ENCASED "LIFER" ELECTRODE IS REQUIRED PER <br />ART 250-50. ISSS N.E.G. MUST BE INSPECTED PRIOR TO <br />CONCRETE PLACEMENT, <br />ELECTRICAL NOTES <br />1) IN ACCORDANCE WITH CHAPTER 411.003 (2) (1) OF THE FLORIDA ADMINISTRATIVE <br />CODE ELECTRICAL, PLUMBING, AND MECHANICAL SYSTEMS SHALL BE DESIGNED BY <br />THE RESPECTIVE CONTRACTORS TO MEET ALL APPLICABLE CODES. THE SYSTEMS <br />DRAWN HERON ARE BASED UPON THE HOMEOWNERS REQUIREMENTS. <br />2) ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHENS, AND EXTERIOR AREAS <br />ABOVE COUNTER HEIGHTS AND WITHIN 6'-O" OF SINKS SHALL BE GFI <br />( GROUND FAULT INTERRUPTER) <br />3) ALL ELECTRICAL OUTLETS IN BEDROOMS SHALL BE WIRED INTO <br />AN ARC -FAULT INTERRUPTER "AR" CIRCUIT. <br />4) SMOKE DETECTORS SHALL BE PLACED IN EACH BEDROOM <br />AND IN HALLWAY AREAS ADJACENT TO BEDROOM AND OTHER <br />LIVING AREAS ( SMOKE DETECTOR PER SECTION SO5.2.5) <br />5) PROVIDE AN OUTLET AND LIGHT WITHIN REACH OF EVERY <br />ATTIC ACCESS AREA FOR ANY FUTURE SERVICE IN <br />THE ATTIC AREA. <br />ELECTRICAL PLAN <br />HVAC VENT LAYOUT <br />APPROX 1.5 TONS OF ADDITONAL <br />AC WILL BE REQUIRED FOR THE <br />NEW ADDITION. THE CONTRACTOR <br />WILL NEED TO VERIFY THIS INFORMATION. <br />600 CFM 18000 BTUS <br />IN ORDER FOR THE AC SYSTEM TO <br />WORK EFFICIENTLY THE CONTRACTOR <br />WILL NEED TO HAVE 6"Af PASS THROUGH <br />VENTS ABOVE ALL DOORS OR INSTALL <br />INDIVIDUAL RETURNS IN EACH ROOM, <br />THE FIRST NUMBERS BY THE GRILL <br />ARE THE SIZE OF THE VENT AND THE <br />LAST NUMBER BY THE GRILL 15 THE DUCT SIZE. <br />THE DUCT WORK, ALL FLEX RUNS AND DUCT RUNS COULD <br />CHANGE DUE TO THE FRAMING OF THE HOUSE AND THE <br />ROOF TRUSSES WEB DESIGNS. THE DUCTS ARE NOT SHOWN <br />FOR THIS REASON, <br />DATE : <br />2/Oro /08 <br />SCALE: <br />1/4" = 1'-O" <br />PAGE 4 <br />DESIGN SERVICES INC, <br />MOBILE/ OFFICE 352-20ro-5821 <br />OFFICE FAX 352-568-2342 <br />R' ` . HANLEY P O BOX 1325 SAN ANTONIO <br />FLA, 33516 <br />THE CLIENT UNDERSTANDS THE THE DESIGNER CARRIES <br />NO LIABILITY INSURANCE AND THEREFOR AGREES TO <br />HOLD HARMLESS, IDEMNIFY, AND DEFEND THE DESIGNER <br />FROM ALL CLAIMS, LOSSES AND EXPENSES( INCLUDING <br />ATTORNEYS FEES) ARISING OUT OF OR RESULTING FROM <br />THE PROJECT. THE DESIGNER IN GOOD FAITH ATTEMPT TO <br />PROVIDE ERROR FREE CONSTRUCTION DRAWINGS. <br />IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT <br />BE HELD LIABLE FOR THE COST OF THE REPAIRS OR <br />DELAY TO THE JOB. THE CONTRACTOR NEEDS TO VERIFY <br />AND UNDERSTAND ALL INFORMATION BEFORE BIDDING <br />OR STARTING ANY WORK ON THE JOB, <br />THE PLUMBING , ELECTRICAL AND MECHANICAL <br />PARTS OF THE PLAN ARE NON-STRUCTURAL AND <br />MAY BE ADJUSTED BY THE SUB -CONTRACTORS <br />PERMITTED TO DO THE JOB, BUT THE CHANGES <br />MUST MEET THE MINIMUM STANDARDS OF THE <br />CURRENT FLORIDA BUILDING CODE. THESE CHANGES <br />ARE NOT REQUIRED TO BE VERIFIED BY THE ENGINEER <br />OF RECORD FOR THIS PLAN. <br />SEE THE SIMPSON STRONG TIES CATALOG FOR ANY <br />ADDITIONAL INFORMATION ON ANY OF THE SIMPSON <br />FASTENERS SPECIFIED ON THIS PLAN. <br />CATALOG C-2008 EFFECTIVE 1/ 1/ 08 <br />BECAUSE THIS IS AN ADDITION IT WILL BE THE <br />RESPONSIBILITY OF ALL SUBS AND SUPPLIERS <br />TO VERIFY ALL INFORMATION IN THE FIELD <br />BEFORE ORDERING ANY MATERIAL OR STARTING <br />ANY WORK. THE HOMEOWNER REQUIRES THAT <br />THIS NEW ADDITION MATCHES THE EXISTNG HOUSE. <br />IF ANY INFORMATION IS NOT ON THIS PLAN THE <br />CONTRACTOR WILL NEED TO VERIFY THAT THE NEW <br />WORK IS MATCHING THE EXISTING. <br />RUD1' and KRISTI DOROUEE <br />5014 12th STREET <br />ZEI=HYRHILLS, FLORIDA <br />EAST PASCO COUNTY <br />33542 <br />TOTAL NEW ADDITION <br />15ro SF <br />DAVID W. SMITH, P.E. <br />FLORIDA LIC.* 53608 <br />352-521-0865 OFFICE <br />352-521-08rol FAX. <br />9909 WALLASTON DRIVE DADE CITY ,FLA. 33525 <br />I HERE5Y CERTIFY THAT I HAVE REVIEWED THIS <br />PLAN AND FOUND IT TO BE IN COMPLIANCE WITH <br />SECTION R-301 OF THE FLA. BUILDING CODE 2004 <br />A5CE I - 02 , THE 2005 AND THE 200ro SUPPLEMENT. <br />THE WIND DESIGN PRESSURES ARE BASED ON <br />A 120 MPH ( 3 SECOND GUST) WIND ZONE. <br />DAVID W. SMITH PE 0 53605 <br />