1) <br />2) <br />3) <br />4) <br />5) <br />6) <br />UPLIFT CONNECTIONS <br />ATTACH THE TRUSSES TO THE TOP OF THE <br />FRAME WALLS WITH SIMPSON H2.5A HURRICANE <br />TIES AT BOTH ENDS. FL503-122 <br />USE SIMPSON VCT2 VALLEY TRUSS CONNECTIONS <br />TO ATTACH LEGS UNDER THE CONVENTIONAL <br />FRAMED RAFTERS TO THE 2X6 PURLINS AND AT <br />THE RIDGE, FL3151-134 <br />FASTEN THE FLOOR BEAMS TO THE PIERS WITH <br />(2) SIMPSON HETA 12 EMBEDDED 5TRAP5 WITH A MIN <br />EMBEDDMENT OF 4". FL1901-128 ATTACH THE WALLS <br />TO THE BEAMS WITH (2) SIMPSON HT816 TRUSS STRAPS. <br />FL538-123 <br />ATTACH THE TOP AND BOTTOM PLATES THE STUDS <br />WITH SIMPSON SPI AND SP2 STUD PLATE TIES AT 32" OG, <br />FL414-121 <br />ALL OPENINGS WILL HAVE SIMP50N DSP STUD PLATE <br />TIES ON EACH SIDE, TOP AND BOTTOM. FL1423-125 <br />USE A 1/2" GO BOLT THREADED ROD ON EACH END <br />OF THE LVL. START AT THE PIER WITH A MIN OF 8" <br />EMBEDDMENT AND GO UP THROUGH THE WALL TO THE <br />TOP OF THE LVL AND ATTACH WITH A 2" SQ STEEL <br />WASHER AND NUT. <br />DATE : <br />2/O6/O8 <br />SCALE.- <br />1/4 11 = V-0" <br />PAGE 5 <br />ALL HEADERS WILL BE A MIN OF A DBL 2X6 <br />DESIGN SERVICES INC, <br />NO PLYWOOD <br />SPACER REQUIRED. NAIL WITH <br />MOBILE/ OFFICE 352-206-5821 <br />12d COMMONS <br />IN (2) STAGGERED ROWS AT 12" orHANLEY I <br />/ OFFICE FAX 352-588-2342 <br />R. S. <br />P O BOX 1325 SAN ANTONIO <br />FLA. 33516 <br />i <br />�t <br />THE CLIENT UNDERSTANDS THE THE DESIGNER CARRIES <br />AND THEREFOR AGREES TO <br />NO LIABILITY INS RANGE A <br />-- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- --�^ <br />----- ----- -- - .. <br />_ - ----- --... - ----- ----- <br />---- ----- ----- <br />J-1 <br />11 <br />HOLD HARMLESSEMNI <br />ESS, ID FY, AN F <br />D DEFEND THE DESIGNER <br />- _i _ <br />'I <br />FROM ALL CLAIMS, LOSSES AND EXPENSES( INCLUDING: <br />ATTORNEYS FEES) ARISING OUT OF OR RESULTING FROM <br />j <br />THE PROJECT. THE DESIGNER IN GOOD FAITH ATTEMPT TO <br />PROVIDE ERROR FREE CONSTRUCTION DRAWINGS. <br />IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT <br />BE HELD LIABLE FOR THE COST OF THE REPAIRS OR <br />ROOF TRUSSES <br />11 <br />DELAY TO THE JOB. THE CONTRACTOR NEEDS TO VERIFY <br />- I'-O" ; CsA E 0R SEE ETAIL <br />qABLE 6RAG &EE DE AIL <br />AND UNDERSTAND ALL INFORMATION BEFORE BIDDING <br />Q <br />- - - - - - - - - - - - <br />OR STARTING ANY WORK ON THE JOB. <br />' <br />' <br />RAT <br />RUNNER <br />>< <br />THE PLUMBING , ELECTRICAL AND MECHANICAL <br />1'-0" <br />PARTS OF THE PLAN ARE NON-STRUCTURAL AND <br />MAY BE ADJUSTED BY THE SUB -CONTRACTORS <br />PERMITTED TO DO THE JOB. BUT THE CHANGES <br />I <br />GAeUk <br />BR <br />E sEE <br />`TAIL- <br />- - - <br />BRACE <br />SEE - - <br />A- <br />MUST MEET THE MINIMUM STANDARDS OF THE <br />CURRENT FLORIDA BUILDING CODE. THESE CHANGES <br />TRU <br />JOIST <br />1.9E <br />MICROLLAM <br />ARE NOT REQUIRED TO BE VERIFIED BY THE ENGINEER <br />-- ----- ----- ----- ----- ----- --- - ----- ----- ----- ----- - -- ----- <br />3 <br />1/2" x <br />11 14" <br />x 16' <br />; <br />OF RECORD FOR THIS PLAN. <br />�I <br />�I <br />-__- <br />- _--- <br />----- <br />----- <br />----- <br />----- <br />----- <br />--- <br />SEE THE SIMPSON STRONG TIES CATALOG FOR ANY <br />' <br />--- <br />----- <br />----- <br />----- <br />----- <br />----- <br />----- <br />-----101----- <br />---- <br />ADDITIONAL INFORMATION ON ANY OF THE SIMPSON <br />FASTENERS SPECIFIED ON THI5 PLAN. <br />2X6 <br />PUR <br />IN AlAG <br />TO <br />THE <br />EXIS <br />ING <br />ROOF <br />FRAMING <br />JITH <br />CATALOG C-2008 EFFECTIVE i/ 1/ 08 <br />l2) 1 d G Mh1 NS AlEA INT RSE TIN LOG TIO <br />-- --- ----- ----- -�,--- ----- ----- ----- ----- ------- <br />EXTERIORRIDGERIDGE ---- ----- ----- ----- ----- -- -- <br />i <br />EXISTING HOUSE <br />O <br />i <br />—'� ROOF- FRAMING PLAN <br />0 <br />PLYWOOD GUSSETT DETAILS <br />8 3/4" <br />16" 1 GUSSETT „$" <br />GUSSETT "A" <br />t t- 12" <br />12" <br />GUSSETT "C" <br />12" <br />GUSSETT "0" <br />GUSSETT "E" <br />n, <br />GUSSETT "F" <br />1) GUSSETTS ARE CUT FROM EXT 1/2" CDX PLYWOOD WITH THE GRAIN RUNNING <br />HORIZONTALLY AND USED ON BOTH SIDES OF THE TRUSS. <br />2) USE 10d x 1 1/2" FASTENERS SPACED EQUALLY AT 4" OC MAX SPACING. <br />INSET THE FASTENERS 3/4" FROM THE EDGES OF THE CHORDS AND WEBS. <br />3) SEE THE DETAIL ABOVE FOR THE NAILING PATTERNS REQUIRED. <br />4) ALL CHORDS AND WEBS WILL BE A MINIMUM OF *2 SOUTHERN YELLOW PINE. <br />SEE THE CROSS SECTION ON PAGE 6 FOR MORE INFORMATION <br />BECAUSE THIS IS AN ADDITION IT WILL BE THE <br />RESPONSIBILITY OF ALL SUBS AND SUPPLIERS <br />TO VERIFY ALL INFORMATION IN THE FIELD <br />BEFORE ORDERING ANY MATERIAL OR STARTING <br />ANY WORK. THE HOMEOWNER REQUIRES THAT <br />THIS NEW ADDITION MATCHES THE EXISTNG HOUSE. <br />IF ANY INFORMATION 15 NOT ON THIS PLAN THE <br />CONTRACTOR WILL NEED TO VERIFY THAT THE NEW <br />WORK IS MATCHING THE EXISTING. <br />RUDI' and KRISTI DOROUEE <br />5614 12th STREET <br />ZEPHYRHILLS, FLORIDA <br />EAST PASCO COUNTY <br />33542 <br />TOTAL NEW ADDITION <br />15ro SF <br />DAVID W. SMITH, P.E. <br />FLORIDA LIC.* 53608 <br />352-521-0865 OFFICE <br />352-521-08ro-I FAX, <br />9909 WALLASTON DRIVE DADE CITY ,FLA. 33525 <br />I HEREBY CERTIFY THAT I HAVE REVIEWED THIS <br />PLAN AND FOUND IT TO BE IN COMPLIANCE WITH <br />SECTION R-301 OF THE FLA. BUILDING CODE 2004 <br />ASCE I - 02 , THE 2005 AND THE 200ro SUPPLEMENT. <br />THE WIND DESIGN PRESSURES ARE BASED ON <br />A 120 MPH ( 3 SECOND GUST) WIND ZONE. <br />DAVID W, SMITH PE N 53608 <br />