FRAMING MOTES: <br />1) <br />ALL WOOD USED FOR SOLE PLATES OR IN CONTACT <br />WITH SOIL WILL BE *2 PT SOUTHERN YELLOW PINE . <br />2) <br />ALL INTERIOR AND EXTERIOR WALLS SHALL BE <br />*2 SPRUCE OR BETTER AND SPACED 16" OC, <br />3) <br />ALL ENG, WOOD BEAMS SUCH AS PARALLAMS <br />HAVE BEEN DESIGNED ACCORDING TO THE <br />TRUSSJOIST SPECIFICATIONS. <br />4) <br />ALL OF THE SIMPSON FASTENERS AND HANGERS <br />MAY BE REPLACED WITH THOSE OF EQUAL OR GREATER <br />VALUES, ALWAYS VERIFY THIS WITH THE ENG. OF RECORD, <br />5) <br />ALL ELECTRICAL,PLUMBING AND MECHANICAL ROUGH INS <br />MUST BE COMPLETED, INSPECTED AND APPROVED PRIOR <br />TO REQUESTING A FRAMING INSPECTION. <br />6) <br />ALL INTERIOR DIMENSIONS ARE GIVEN TO THE INDICATED <br />CENTER OF THE STUD UNLESS NOTED OTHERWISE, <br />1) <br />ALL OF THE EXTERIOR DIMENSIONS ARE GIVEN TO THE <br />FACE OF THE FRAME OR MASONRY WALL WHICH WILL <br />ALIGN WITH THE FOUNDATION WALL BELOW. (FRAME <br />WALLS ARE HELD IN 1/2" TO ALIGN THE EXTERIOR <br />SHEATHING WITH THE FOUNDATION). <br />8) <br />ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY <br />SHALL BE PRESSURE TREATED LUMBER. <br />9) <br />ALL WOOD HEADERS ARE TO BE NO LESS THAN A DBL 2X6 <br />*2 SOUTHERN YELLOW PINE WITH A 1/2" SPACER, <br />SIMPSON 2.5A <br />HURRICANE TIES <br />FL503-122 <br />ALUM. DRIP EAVE <br />2X FASCIA PAINTED <br />ATTIC VENTILATION <br />FOR GABLES OR HIP ROOFS VENTILATION SHALL BE <br />PROVIDED TO FURNISH CROSS VENTILATION OF EACH <br />SEPERATE ATTIC, THE RATIO OF TOTAL NET FREE <br />VENTILATING AREA TO THE AREA OF THE CEILING <br />SHALL BE NOT LESS THAN 1/150, <br />EXTERIOR WINDOWS AND DOORS <br />*1 ALL EXTERIOR WINDOWS AND GLASS DOORS OR ENTRANCE <br />DOOR SHALL BE TESTED IN ACCORDANCE WITH <br />ANSI/AMMA/NWWDA 101/182 STANDARD AND BEAR IN AMM OR <br />WDMA LABEL IDENTIFYING THE MANUFACTURERS PERFORMANCE <br />CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY. <br />*2 ALL MULLIONS AND ADJACENT DOOR/WINDOW ASSEMBLIES <br />SHALL BE TESTED OR ENGINEERED TO TRANSFER 1.5 TIMES THE <br />DESIGN LOADS TO THE ROUGH OPENINGS SUBSTRATE. <br />*3 INSTALL ALL WINDOWS AND DOOR ASSEMBLIES PER THE <br />MANUFACTURERS ANCHORING RECOMMENDATIONS TO ACHIEVE <br />THE DESIGN PRESSURE SPECIFIED, <br />1/2" CDX (32/24) OR OSB SHEATHING NAILED <br />WITH 8d COMMONS AT (o" OC UNLESS OTHERWISE NOTED <br />ROB <br />5� <br />t1A`� �F gN 00��0�5 <br />VENTED SOFFITT <br />NOVELTY PINE SIDING OVER <br />1/2" CDX OR 055 SHEATHING <br />1/2" DRYWALL ON ALL <br />WALL INTERIORS <br />MIN R-11 WALL INSULATION <br />SIMPSON SPI FL414-121 AND 5P2 FL414-121 <br />STUD PLATE TIES MAX 48" OC <br />(2) SIMPSON HTS16 TRUSS STRAPS <br />PER PIER. FL538-123 -_ <br />*5 REBAR IN FILLED CELLS IN THE <br />8"x16" CONCRETE PIERS.ALL CELLS <br />WILL BE FILLED. �\ <br />GRADE <br />THE BOTTOM OF THE FOOTER r„ <br />WILL BE A MIN OF 12" <br />INTO EXISTING GROUND <br />*30 ROOFING FELT <br />WOOD TRUSSES * 24" OC <br />*31 MIN TOTAL LOADING <br />R-30 INSULATION <br />1/2" CEILING DRYWALL ON ALL INTERIOR CEILINGS <br />------------------- ------- [[ ------ �k ----- ------ ------ ------ ------ - <br />2X6PLIC BLOC S - <br />2X4 OR 2x6 *2 SPRUCE STUDS AT 16" OC <br />WITH A DBL TOP PLATE ON I <br />ALL BEARING WALLS. 1/2"' (321241 CDX OR OSB SHEATHING <br />NAILED FROM THE BOTTOM OF THE <br />FLOOR JOIST TO THE TOP OF THE <br />A MIN OF A DBL 2 x 6 *2 FRAME WALLS, <br />SOUTHERN YELLOW PINE NAIL THE SIDE EDGES 6" OC <br />HEADERS ON ALL EXTERIOR NAIL THE INTERIOR 12"OC <br />FRAME OPENINGS NAIL THE END EDGES 3"' OC <br />3/4" STURDI FLOR T4G SHEATHING <br />GLUED AND NAILED WITH 8d COM <br />AT 6" OC EDGES 12" OC ALL OTHER <br />AREAS II \ II II II <br />2x10 FLOOR JOIST AT 16" OC SIMP50N LU28 FACE MOUNTED <br />U HANGER FL414-121 <br />(2) 5IMP50N HETA 12 EMBEDDED STRAPS <br />PER PIER TO ATTACH THE FLOOR BEAMS <br />TO THE CONCRETE PIERS, <br />ALL FLOOR JOIST, ROOF RAFTERS, AND HEADERS <br />SHALL BE NO LESS THAN *2 SOUTHERN YELLOW PINE <br />LUMBER, IF THE LUMBER WILL BE IN THE WEATHER OR <br />CLOSER THAN 18" FROM THE GROUND IT WILL NEED <br />TO BE PRESSURE TREATED. EXCEPT AS NOTED. <br />THE EXISTING STRUCTURE WAS INSPECTED <br />PRIOR TO THE DESIGN AND ENGINEERING OF <br />THE NEW PLAN. ' <br />THERE WILL BE NO ADDITIONAL LOADS ADDED <br />TO THE EXISTING LOAD BEARING CAPACITY OF THE <br />BUILDING. <br />ROOF TRUSSES <br />24" OC MAXIMUM SPACING-: <br />TC LL 20.0 PSF <br />TC DL -1.0 P5F <br />BC DL 10.0 PSF <br />BC LL 0.0 PSF <br />TOT.LD_ 31.0 PSF <br />DUR.FAC. 1.25 <br />DEFLECTION MEETS L / 3roO LIVE <br />AND L / 240 TOTAL LOAD <br />NAIL 2x BLOCKING BETWEEN TRUSSES IN ALL <br />AREAS THAT A PLY -CLIP CANT BE APPLIED. <br />SIMPSON VTC2 <br />METAL ROOFING INSTALLED VALLEY TRUSS CLIP <br />PER <br />DETAIL HEMANUFACTURER THE OR\�' FL3151-134 <br />AS PER <br />SIMPSON 2,5A <br />HURRICANE TIES <br />FL503-122 <br />SIMPSON VTC2 <br />VALLEY TRUSS CLIP <br />FI-3151-134 <br />2x6 PURLINS ATTACHED TO THE <br />EXISTING FRAMING WITH (2) 16d COMMONS <br />AT EACH INTERSECTING LOCATION <br />ATTIC ACCESS <br />ATTIC ACCESS SHALL BE PROVIDED TO ATTIC AREAS <br />EXCEEDING 30 SQ,FT, AND HAVING MINIMUM 30 INCHES OF <br />VERTICAL HEIGHT. ROUGH FRAMED OPENINGS NOT TO BE <br />LESS THAT 22"X30" INCHES. WHEN MECHANICAL EQUIPMENT IS <br />LOCATED IN THE ATTIC IT SHALL BE INSTALLED IN <br />ACCORDANCE WITH 2O04 FLORIDA BUILDING CODE <br />RESIDENTIAL -SECTION M1305.1.3. <br />FLOOR JOIST LOADING <br />40 PSF LIVE LOAD <br />10 PSF DEAD LOAD <br />360 DEFLECTION <br />MAX SPAN FOR Iro" OC SPACING IS <br />WITH NO.2 GRADE 2x10 JOISTS <br />CROSS SECTION <br />EXISTING HOUSE <br />�s <br />N\� <br />DATE : SCALE: <br />20ro /08 1/2 _ �-o i, PAGES <br />- <br />DESIGN SERVICES INC, <br />MOBILE/ OFFICE 352-206-5521 <br />OFFICE FAX 352-588-2342 <br />R' 8' HANLEY P 0 BOX 1325 SAN ANTONIO <br />FLA, 33516 <br />THE CLIENT UNDERSTANDS THE THE DESIGNER CARRIES <br />NO LIABILITY INSURANCE AND THEREFOR AGREES TO <br />HOLD HARMLESS, IDEMNIFY, AND DEFEND THE DESIGNER <br />FROM ALL CLAIMS, LOSSES AND EXPENSES( INCLUDING <br />ATTORNEYS FEES) ARISING OUT OF OR RESULTING FROM <br />THE PROJECT. THE DESIGNER IN GOOD FAITH ATTEMPT TO <br />PROVIDE ERROR FREE CONSTRUCTION DRAWINGS, <br />IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT <br />BE HELD LIABLE FOR THE COST OF THE REPAIRS OR <br />DELAY TO THE JOB. THE CONTRACTOR NEEDS TO VERIFY <br />AND UNDERSTAND ALL INFORMATION BEFORE BIDDING <br />OR STARTING ANY WORK ON THE JOB, <br />THE PLUMBING , ELECTRICAL AND MECHANICAL <br />PARTS OF THE PLAN ARE NON-STRUCTURAL AND <br />MAY BE ADJUSTED BY THE SUB -CONTRACTORS <br />PERMITTED TO DO THE JOB. BUT THE CHANGES <br />MUST MEET THE MINIMUM STANDARDS OF THE <br />CURRENT FLORIDA BUILDING CODE. THESE CHANGES <br />ARE NOT REQUIRED TO BE VERIFIED BY THE ENGINEER <br />OF RECORD FOR THIS PLAN, <br />SEE THE SIMPSON STRONG TIES CATALOG FOR ANY <br />ADDITIONAL INFORMATION ON ANY OF THE SIMPSON <br />FASTENERS SPECIFIED ON THIS PLAN. <br />CATALOG C-2008 EFFECTIVE i/ 1/ 08 <br />BECAUSE THIS IS AN ADDITION IT WILL BE THE <br />RESPONSIBILITY OF ALL SUBS AND SUPPLIERS <br />TO VERIFY ALL INFORMATION IN THE FIELD <br />BEFORE ORDERING ANY MATERIAL OR STARTING <br />ANY WORK. THE HOMEOWNER REQUIRES THAT <br />THIS NEW ADDITION MATCHES THE EXISTNG HOUSE. <br />IF ANY INFORMATION IS NOT ON THIS PLAN THE <br />CONTRACTOR WILL NEED TO VERIFY THAT THE NEW <br />WORK IS MATCHING THE EXISTING. <br />RUDY and KRISTI DOROUEE <br />5814 12th STREET <br />ZEPHY'RHILLS, FLORIDA <br />EAST PASCO COUNTY <br />33542 <br />TOTAL NEW ADDITION <br />i5ro SF <br />DAVID W. SMITH, P.E. <br />FLORIDA LIC.0 53608 <br />352-521-0885 OFFICE <br />352-521-08rol FAX, <br />9909 WALLASTON DRIVE DADE CITY ,FLA. 33525 <br />I HEREBY CERTIFY THAT I HAVE REVIEWED THIS <br />PLAN AND FOUND IT TO BE IN COMPLIANCE WITH <br />SECTION R-301 OF THE FLA. BUILDING CODE 2004 <br />ASCE I - 02 , THE 2005 AND THE 200ro SUPPLEMENT. <br />THE WIND DESIGN PRESSURES ARE BASED ON <br />A 120 MPH ( 3 SECOND GUST) WIND ZONE, <br />DAVID W. SMITH PE * 53608 <br />