1 11 . nky i !!1 <br />WI_ <br />MIN 2X4 02 PINE <br />X-CROSS BRACING <br />2X4 DIAGONAL <br />NAILED TO vE <br />WITH (2) 12d CC <br />AND INTO THE <br />THE COMMON TF <br />THE BOTTOM OF <br />MIN IX4 <br />CONTINUOUS e2 PINE <br />TRUSS BRACING <br />X-eRACING DETAIL <br />MAX OF 20'-0il OC <br />NAIL SHEATHING 3" OC <br />i 5'-0" FROM GABLE <br />BRACE <br />IRS - <br />2T WEB <br />MMONS <br />roe OF <br />:U5$ AND <br />HE GABLE <br />2X4 <br />5'-0" STRINGER <br />` <br />DSL 2X HEADER <br />THE TRUSS COMPANY WILL BE <br />REQUIRED TO PLACE A PERT <br />t A <br />�F (2) <br />7MMONS <br />U55 JOINT <br />X-JOINT <br />2X4 BLOCKINr NAILED TO <br />THE TRUSSES TOP AND BOTTOM <br />WITH (2) 12d COMMONS EACH END <br />FOR W-O" IN FROM THE GABLE <br />\ 12" MAX OH <br />WITHOUT <br />OUTLOOKERS <br />WEB AT HE GABLE BRACING EXTERIOR WALL <br />LOCATIONS. OR POST <br />GABLE BRACiNG DETAIL <br />FOUNDATION AND SLAB NOTE <br />el THE BUILDING SITE SHALL BE SCRAPED TO REMOVE <br />ALL ORGANIC MATERIALS. ANY ADDITIONAL FILL PLACED ON THE <br />BUILDING PAD AREA SHALL BE COMPACTED SUCH THAT IT CAN <br />ADEQUATELY SUPPORT A 2000 P.S.F. FOUNDATION LOADING, <br />THE SLAB SHALL BE PLACED OVER A &MIL VAPOR BARRIER ON <br />CLEAN ADEQUATELY COMPACTED AND TERMITE POISONED SOIL, <br />THE CONCRETE UTILIZED IN THE FOUNDATION AND SLABS SHALL <br />HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3000 P.S.I. <br />e2 REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND <br />IDENTIFIED IN ACCORDANCE WITH ASTM A -615. LAP SPLICES, WHERE <br />REQUIRED SHALL BE A MINIMUM OF 25" FOR 05 REBAR, 30" FOR efo <br />REBAR AND 35" FOR *1 REBAR. <br />AT LEAST ONE TRUSS SPACE LAPPED <br />MIN (2) 12c1 PER JOINT <br />RAT -RUN BRACING DETAIL <br />MAX OF 10'-0" OC SPACING <br />GLAZING <br />MIN IX4 <br />NTINUOUS e2 PINE <br />TRUSS BRACING <br />GLAZING THE FOLLOWING SHALL BE CONSIDERED SPECIFIC <br />HAZARDOUS LOCATION FOR THE PURPOSE OF- <br />e1 GLAZING IN SWING DOORS, FIXED AND SLIDING PANEL OF <br />SLIDING DOORS ASSEMEBLIES. <br />02 GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, <br />WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATH TUBS AND <br />SHOWERS, GLAZING IN ANY PORTION OF A BUILDING WALL <br />ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE <br />OF THE GLAZING IS LESS THAN 60" ABOVE THE DRAIN INLET. <br />03 GLAZING IN INDIVIDUAL FIXED OR OPERABLE PANEL <br />ADJACENT A DOOR WHERE THE NEARBY VERTICAL EDGE IS <br />WITHIN A 24" RADIUS OF THE DOOR IN A CLOSED POSITION <br />AND WHOSE BOTTOM EDGE IS LESS THAN 60" ABOVE THE <br />FINISH FLOOR OR WALKING SURFACE. <br />e4 GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL <br />OTHER THAN THOSE LOCATIONS DESCRIBED IN ITEMS (2) AND <br />(3) ABOVE. THAT MEETS ALL THE FOLLOWING <br />(A) EXPOSED AREA OF AN INDIVIDUAL PANEL OTHER THAN <br />THOSE LOCATIONS <br />(B) BOTTOM EDGE LESS THAN 18" ABOVE THE FLOOR <br />(C) TOP EDGE GREATER THAN 3ro" ABOVE THE FLOOR <br />(D) ONE OR MORE WALKING SURFACES WITHIN 3ro" <br />HORIZONTALLY OF THE PLANE OF THE GLAZING <br />REFER TO THE THE 2004 FLORIDA BUILDING CODE <br />RESIDENTIAL -SECTION R305 FOR ADDITONAL AREAS THAT <br />MAY BE CONSIDERED A HAZARDOUS LOCATION FOR THE <br />PURPOSE OF GLAZING <br />TREATMENT: ( SOiL CHEMiCAL BARRIER METHOD) <br />9) CONCRETE OVER POUR AND MORTAR ALONG THE FOUNDATION PERIMETER MUST BE <br />1) <br />A PERMANENT SIGN TO IDENTIFY THE TERMITE TREATMENT PROVIDER AND <br />REMOVED BEFORE EXTERIOR SOIL TREATMENT <br />NEED FOR RE -INSPECTION AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. <br />THE SIGN SHALL BE P05TED NEAR THE WATER HEATER OR ELECTRIC PANEL <br />10) <br />SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE WITH 1'-0" <br />OF THE STRUCTURES 51DEWALLS. <br />2) <br />CONDINSATE AND ROOF DOWN SPOUTS SHALL DICHARGE AT LEAST 1'-0" AWAY FROM <br />THE BUILDING SIDEWALLS <br />11) <br />AN EXTERIOR VERTICAL CHEMICAL BARRIERS MUST BE INSTALLED AFTER <br />CONSTRUCTION IS COMPLETE INCLUDING LANDSCAPING AND IRRIGATION. <br />3) <br />IRRIGATION 5Y5TEM5 INCLUDING ALL RISERS AND SPRAY HEADS SHALL <br />ANY SOIL DISTURBED AFTER THE VERTICAL BARRIER 15 APPLIED, SHALL BE <br />NOT BE INSTALLED WITHIN 1'-0" OF THE BUILDINGS 51DEwALL5 <br />RETREATED. <br />4) <br />TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION BETWEEN WALL COVERING <br />12) <br />ALL BUILDINGS ARE REQUIRED TO HAVE PRE -CONSTRUCTION TREATMENT <br />AND FINAL EARTH GRADE SHALL NOT BE LESS THA G6 INCHES ( EXCEPTION PAINT OR <br />DECORATIVE CEMENTIOUS FiNiSH LE55 THAN 5/5" THICK ADHERED DIRECTLY TO THE <br />13) <br />A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPARTMENT BY <br />FOUNDATION WALL.) <br />A LICEN5ED PEST CONTROL COMPANY BEFORE A CERTIFICATE OF OCCUPANCY WILL <br />BE ISSUED. THE CERTIFICATE OF COMPLIANCE SHALL STATE: " THE BUILDING HAS <br />5) <br />INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACK FILL 15 COMPLETED. <br />RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES_ <br />THE TREATMENT 15 IN ACCORDANCE WITH THE RULES AND LAWS OF THE <br />6) <br />SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RETREATED INCLUDING SPACES BOXED <br />FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES. <br />OR FORMED, <br />14) <br />AFTER ALL WORK 15 COMPLETE LOOSE WOOD AND FILL MUST BE REMOVED FROM <br />"U <br />BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLLATION OF TRAPS, ETC. SHALL BE: <br />BELOW AND WiTHIN 1'-0" OF THE BUILDING. THIS INCLUDES ALL GRADE 5TAKES,TUB <br />MADE WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF A SIZE AND <br />TRAP BOXES, FORMS,SHORING OR OTHER CELLULOSE: CONTAINING MATERIAL. <br />DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF SOIL AFTER THE INITIAL TREATMENT , <br />15) <br />NO WOOD , VEGETATION, STUMPS, CARDBOARD ,TRASH ETC. , SHALL BE BURIED WITHIN <br />8) <br />A MINIMUM 6 MIL VAPOR RETARDER MUST BE INSTALLED TO PROTECT AGAINST <br />15-0" OF ANY BUILDING OR PROPOSED BUILDING <br />RAINFALL DILUTION. IF RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT, <br />RE -TREATMENT 15 REQUIRED, <br />UNION <br />WHRLIGPTING COMP;MVy <br />Important Notice: This is only a guide. It is the users responsibility to verify local building code <br />requirements. Please check with your local building code office before beginning any project. <br />If metal is not to be installed immediately, store inside in a well ventilated, dry location. Condensation or other moisture can form between the <br />sheets during storage causing water stains or white rust which de)xac is frorn the appearance of the product and may affect the product's useful <br />life. Trapped moisture between sheets of painted metal can cause white rust to form underneath the paint. This can cause the paint to flake <br />off the panel immediately or several years later. To prevent white rust and staining, break the shipping bands on the material. Store the material <br />on end or on an incline of at least 8"with a supporting board underneath to prevent sagging, Fan the sheets slightly at the bottom to allow for <br />air circulation. Keep the sheets off of the ground with an insulator such as wood. Any outdoor storage is at the customer's own risk_ If outdoor <br />storage cannot be avoided, protect the metal using a canvas cover or waterproof paper. Never cover the metal with plastic as this will cause <br />condensation to form. <br />Insure that the structure Is square and true before beginning panel installation. If the structure is not square, the panels will not properly seal <br />at the side laps. Green or damp lumber is not recommended. Moisture released from thedamp lumber may damage the metal panels. Remove <br />any loose metal shavings left on roof surface immediately to prevent corrosion. Keep roof free of debris that could trap moisture on the metal, <br />causing corrosion. <br />Always wear heavy gloves when working with steel pant -is to avoid cuts from sharp edges. When power cutting or drilling steel panels, always <br />wear safety glasses to prevent eye injury from flying metal fragments. If you must walk on a metal roof, take great care. Metal panels can <br />becortie slippery, so always wear shoes with non slip soles. Avoid working on metal roof, during wet conditions when the panels can become <br />extremely slippery. Walking or standing on a metal roof which does not have a plywood or other deck beneath it is not recommended. Now <br />MCI, if you must do so, always walk on the purlins, never between. Do not, for any reason, walk on a roof made of naterial thiniier than 29 <br />gauge. <br />If you wish to pre drill fastener holes, use a cover sheet to prevent hot metal <br />shavings from sticking to panels. It is recommended that you cut panels upside <br />down using a nibbler. For best results, use double washered wood screws, minimum <br />of 1"long. Position screws as shown in Figure 1 below. Screws should be applied at <br />every purlin. Do not overdrive the screw as this will form a dimple which can collect <br />water and Gausu I(•.akayrr. Do not leave any loose screw that have missed the purlin. <br />Remove the screw and seal the hole with butyl caulking or stitch screw. Do not <br />apply screws through the anit-siphoning channel. <br />x; <br />I AS IENiN(. PATTERN FOR t -112" SCREWS - EAVE & ENDLAPS <br />Underdriven <br />Overdriven <br />Correct <br />_ <br />X <br />7 <br />e <br />v <br />_- <br />FASTFNING PATTERN FOR 1-ir'2"SCREWS-INTERMEDIATE <br />-u•w.rv- <br />antl:lla+onlrq <br />d.:n"ra <br />.rrr�r.1—rO�I�% <br />cwn. <br />Ia.• <br />For best results, start siding at door, window, or other opening in the wall, Use corner trim or other standard trim for strong, neat edges. <br />Slopes of less than 3" on 12" are not recommended. For slopes of Yon 12" or greater, end lap panels 6". Side laps should face away from the <br />prevailing wind. Lay the first sheet along the eave at the down wind side of the roof, farthest away from the direction of the prevailing winds. <br />Install streets in the sequence shown in Figure 3,always end lapping the upper panel on the top of the lower pastel. <br />-11—.11V 1Harry—L—."t­—W, VV —P4rrN Cutts.-3 ',q Lr JJ --,I.V PILYC11r Itra-1VIMUM If 1—aCCrUV11 Gl VFCI III 19a. IV <br />protect against uplifting winds and to provide a finished appearance,apply rake trim or other standard gable trim. Apply fasteners every 6"-1 u" <br />14"ridge cap is recommending to prevent leakage. Seal off ridge and panel using outside closure strip. Use of 3/8" butyl caulk tape is recom <br />mended at all side laps, especially for more shallow roofs. Apply the tape as shown in Figure 2 (front) at all lap ribs. Do not block the siphon <br />channel with the tape. <br />• Dade County NOA #05 0919.07 - UL 790 Fire Resistance class 4 <br />• Florida Building Code Approval'#FL4586.1,#FL6144.3 - UL 2218Impact Resistance Class 4 <br />• Texas Department of Insurance Approval 0119 - UL 580 Uplift UL Class 90 CONSTRUCTION 11579 <br />Ma: imum purlin spacing for roof Yon center and maximum girt spacing for sidewall 3' on center. Place fasteners in the pan of panel for best <br />results. (Three spans or more) <br />LIVE LOAD (Ib/ft <br />WIND LOAD (Ib/ft') <br />SPAN (INCHES) <br />12" <br />15" <br />18" <br />21" <br />24" <br />2" <br />15" <br />18" <br />21" <br />24" <br />30" <br />( 36" <br />29 Gauge <br />146 <br />93 <br />64 <br />47 <br />36 <br />235161200 <br />128 <br />84 <br />65 <br />5U <br />32 <br />22 <br />26 Gauge <br />200 <br />128 <br />89 <br />65 <br />30 <br />67 <br />170 <br />118 <br />87 <br />1 66 <br />1 42 <br />1 29 <br />NOTES: <br />1. Theoretical allowable loads are based on section properties and allowables calculated in accordance with 2U01 AISI Specifications. <br />2. Theoretical allowable loads are based on three or more uniform spans. <br />3. For roof panels, deduct self weight for actual live load' capacity of the panel. <br />4. These loads are for panel strength. Frames, purlins, decks and fasteners must be designed to resist all loads imposed on the panel. <br />5. (-heck local building codes if panel testing is required. <br />It is the users responsib fifty to verity all zpplicable code requirements for the area.check all measuremerrts, and determine sui cab lity of product torlob, Implied vaarranties or merchantahi ay and rrtfws: <br />fnr ryartir•ular r" irnnc" ary riicrlaimrd fnpyrir0 1�OR F.y Uninn fnrneral ir.rJ rornpany. At: rights rwvervr>d, PJo part r oRhis drrum:r.l nxy hrt• r�ar•rl nrr-d nr rliYrihnred in any fnrrn v.•hnrcntHar wFthnu t <br />pr';ar mitten authorization. <br />Rev 'I I/06 <br />o� <br />DATE <br />2/Oro /OS <br />SCALE., �I PAGE <br />"II/4 = I -O <br />DESIGN SERVICES INC, <br />F=- <br />MOBILE/ OFFICE 352-206-582Z <br />OFFICE FAX 352-588-2342 <br />' HANLEY P O BOX 1325 SAN ANTONIO <br />FLA, 33516 <br />THE CLIENT UNDERSTANDS THE THE DESIGNER CARRIES <br />NO LIABILITY INSURANCE AND THEREFOR AGREES TO <br />HOLD HARMLESS, IDEMNIFY, AND DEFEND THE DESIGNER <br />FROM ALL CLAIMS, LOSSES AND EXPENSES( INCLUDING <br />ATTORNEYS FEES) ARISING OUT OF OR RESULTING FROM <br />THE PROJECT, THE DESIGNER IN GOOD FAITH ATTEMPT TO <br />PROVIDE ERROR FREE CONSTRUCTION DRAWINGS. <br />IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT <br />BE HELD LIABLE FOR THE COST OF THE REPAIRS OR <br />DELAY TO THE JOB. THE CONTRACTOR NEEDS TO VERIFY <br />AND UNDERSTAND ALL INFORMATION BEFORE BIDDING <br />OR STARTING ANY WORK ON THE JOB, <br />THE PLUMBING , ELECTRICAL AND MECHANICAL <br />PARTS OF THE PLAN ARE NON-STRUCTURAL AND <br />MAY BE ADJUSTED BY THE SUB -CONTRACTORS <br />PERMITTED TO DO THE JOB. BUT THE CHANGES <br />MUST MEET THE MINIMUM STANDARDS OF THE <br />CURRENT FLORIDA BUILDING CODE. THESE CHANGES <br />ARE NOT REQUIRED TO BE VERIFIED BY THE ENGINEER <br />OF RECORD FOR THIS PLAN, <br />SEE THE SiMPSON STRONG TIES CATALOG FOR ANY <br />ADDITIONAL INFORMATION ON ANY OF THE SIMPSON <br />FASTENERS SPECIFIED ON THIS PLAN. <br />CATALOG C-2008 EFFECTIVE 1/ 1/ 08 <br />BECAUSE THIS iS AN ADDITION IT WILL BE THE <br />RESPONSIBILITY OF ALL SUBS AND SUPPLIERS <br />TO VERIFY ALL INFORMATION IN THE FIELD <br />BEFORE ORDERING ANY MATERIAL OR STARTING <br />ANY WORK, THE HOMEOWNER REQUIRES THAT <br />THiS NEW ADDITION MATCHES THE EXISTNG HOUSE, <br />IF ANY INFORMATION IS NOT ON THIS PLAN THE <br />CONTRACTOR WILL NEED TO VERIFY THAT THE NEW <br />WORK IS MATCHING THE EXISTING. <br />RUDI' and KRISTI DOROUEE <br />5014 12th STREET <br />ZEPHYRHILLS, FLORIDA <br />EAST PASCO COUNTY <br />33$4 <br />z <br />TOTAL NEW ADDITION <br />DAVID W. SMITI-4, PP <br />a, <br />156 5F <br />FLORIDA LiC.0 53,608 <br />352-521-0865 OFFICE 352-521-08ro-1 FAX. <br />9909 WALLA5TON DRIVE DADE CiTY ,FLA. 33525 <br />I HEREBY CERTIFY THAT I HAVE REViEWED THIS <br />PLAN AND FOUND IT TO BE IN COMPLIANCE WITH <br />SECTION R-301 OF THE FLA. BUILDING CODE 2004 <br />ASCE 1 - 02 , THE 2005 AND THE 2006 SUPPLEMENT. <br />THE WIND DESIGN PRESSURES ARE BASED ON <br />A 120 MPH ( 3 SECOND GUST) WIND ZONE. <br />DAViD W. SMITH PE * 53608 <br />