My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6201 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6201 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 8:24:07 PM
Creation date
2/19/2025 8:22:58 AM
Metadata
Fields
Template:
Building Plans
Street #
6201
Location
Back Forty Lp
Contractor
Lennar Home
Building Plans - Permit #
6076
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
min^ Klkl� <br />ELEC <br />METER <br />I I I <br />L — — — — — — --------J <br />FIRST FLOOR ELECTRICAL PLAN (ELEVATION B <br />1 /4„ = 1'-011 <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS- WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST 3' FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />k <br />NOTES: <br />NLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY RCOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL, BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />NEMA 1 01 <br />#12 copper to 20 amp ckts <br />200 AMP <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />METER <br />2/0 or 4/0 SER Alu <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />APR 0 8 7023 <br />\1_?A� <br />virtual Review Assist, Inc. <br />pians Review coMOOt" and approved <br />for compliance with the 2070 F C 7th Edition <br />4:!i Vi°era Anne ?s)ah+ <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />io <br />SWITCH ° <br />DOORJAMB DUPLEX io <br />OUTLET ih <br />TRIM o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />14 <br />WALL <br />o Z <br />i— <br />S <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT 1HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />�} TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />QSTRUCTURED WIRE OUTLET <br />�— SWITCH AT 36" <br />6 3 WAY SWITCH AT 36" <br />-e4Z- 4 WAY SWITCH AT 36" <br />-p PUSH BUTTON FOR GARAGE DOOR OPENER <br />DIMMER SWITCH AT 36" <br />—0 PUSH-BUTTON DOORBELL <br />CLG MNT LT FIXTURE <br />-Ee} CLG MNT PREWIRE - FIXTURE BY OWNER <br />SURFACE MNT FIXTURE <br />{- WALL MNT FIXTURE <br />r NOTE: <br />C TUB/SHOWERND OPALEX - ALTERNATE <br />CANS MAY BE <br />50W PAR30 NFL 6WHITE BAFFLE <br />C " USEDIF <br />BY <br />06 50W MR16 4" LOW VOLTAGE OWNER <br />C 50W PAR20 NFL 4" MINI ROUND RECESS <br />�� 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-(- CLG FAN PREWIRE AND SWITCH <br />cs COMBINATION CARBON MONOIXED DETECTOR/ <br />SMOKE DETECTOR <br />C SMOKE DETECTOR <br />=U-18= UNDER CABINET 18" <br />=S-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 — UNDER CABINET 36" <br />S-36 — SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 j 48"CLG MNT WRAPPED FLUOR LIGHT <br />FF24:;:R 24" VANITY LIGHTING <br />FFFF 36 -7� 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />EXHAUSTFAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />O CEILING MNT SPEAKER <br />EM CHIMES (DELETE W/ INTERCOM) <br />= MASTER STATION <br />_11111iiZI ELEC PANEL <br />VACUM OUTLET AT 12" <br />WA CEILING RETURN AIR <br />A/C REGISTER <br />OT THERMOSTAT <br />ED SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />N <br />NLO� <br />N E <br />O <br />to <br />V ,v_ M <br />A� E _ L M <br />0 Lo o <br />} 0 <br />o �o o Q <br />.Ns <br />W�� �� <br />QN <br />6. <br />^` <br />W <br />C <br />�O � N <br />6. E70 a <br />W <br />U' W <br />ow (6 w0E-- <br />LU <br />I—~ M J Q ¢< zO� <br />���Ja0a�¢�UO0JO <br />F— <br />J � > c% Q <br />0WOWOZOEOLuu5Omzz�U <br />J — <br />CJ 0 <br />P <br />-�"CL>�YOZZ�0<LU <br />0OJ <br />LL <br />O w Y❑ Q <br />Q Q <br />OQ O<< <br />LL w <br />O <br />O <br />Z N <br />OF_ <br />U) ::) ti <br />M O <br />Q w M <br />14, <br />(n � <br />l` <br />z <br />< W lq <br />-��c'M <br />Z U <br />W <br />J O <br />O <br />d' <br />r� <br />I <br />I <br />I <br />O <br />NO <br />p <br />N <br />O <br />N <br />c— <br />N <br />N <br />N <br />M <br />N <br />N <br />ti <br />N <br />N <br />N <br />N <br />N <br />O <br />0 <br />o <br />O <br />— <br />N <br />0 <br />N <br />o <br />I <br />I <br />t <br />Z <br />O <br />N <br />W <br />'j' <br />O <br />O <br />O <br />O <br />O <br />O <br />I <br />i <br />> <br />� <br />N <br />M <br />4 <br />6 <br />CO <br />i <br />I <br />Cr <br />w <br />}~ <br />ZZ <br />W <br />Q� w <br />O <br />}, <br />A <br />W <br />Z <br />0 <br />^ <br />WOO <br />U <br />U U) <br />i1 <br />-0 <br />0 <br />ow- <br />O�70 <br />Q <br />z <br />a —IL <br />w <br />Q <br />w <br />�� 2 <br />CAI <br />� <br />z o = <br />W <br /><�0 <br />0 <br />zwo <br />U <br />� <br />a.Zw <br />az <br />z <br />U <br />0 <br />_o <br />W <br />z <br />Z <br />z <br />w <br />w <br />J <br />ti <br />� <br />LAST PLOT DATE <br />o <br />• <br />March 23, 2023 <br />z <br />O <br />1ST FLOOR <br />ELECTRICAL PLAN B <br />l — _ -- -- _ _ — — I I I I ]I--T11 1 I: I <br />
The URL can be used to link to this page
Your browser does not support the video tag.