Laserfiche WebLink
ROOF FINISH <br />PER ELEVATION <br />12 <br />15 ROOF SHEATHING <br />MANUFACTURED <br />ROOF TRUSS <br />MTL DRIP EDGE <br />2X4 SUB -FASCIA <br />ALUMINUM WRAP <br />ALUMINUM SOFFIT <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />DE <br />TAIL L3/4 <br />E61SOFFIT <br />- 1 -0 <br />ROOF FINISH <br />PER ELEVATION <br />ROOF SHEATHING <br />12 <br />5.9 MANUFACTURED <br />ROOF TRUSS <br />MTL DRIP EDGE <br />.o <br />ALUMINUM WRAP <br />ALUMINUM SOFFIT <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />SOFFIT DETAIL <br />7 <br />3/419- 11-011 <br />N <br />o <br />T <br />CV <br />1 <br />N <br />CN <br />211 2" <br />1 11 <br />FALSE FOAM LOUVER DETAIL TYP <br />8 <br />n <br />6" <br />1" 411 111 <br />N N <br />O -0� 1 O - <br />1 00 <br />EPS <br />ci FOAM <br />BRACKET DETAIL <br />9 <br />, <br />PROVIDE FILLED SOLID <br />CMU ABOVE LINTEL TO <br />TIE BEAM <br />FLASHING <br />CASING BEAD WITH WEEP HOLES <br />PT 2X8 LEDGER ATTACHED TO <br />WALL W/ 3/8" X 5" TITEN HD AT <br />12" O.C. STAGGERED <br />(S)H10A 2 <br />ROOF FINISH PER ELEVATION <br />UNDERLAYMENT <br />ELEV AT 8'-0" <br />_ <br />12 T.O.M. <br />A-,.. —15 <br />ROOF SHEATHING <br />(S)A23 <br />MTL DRIP EDGE <br />2X4 SUB -FASCIA <br />'.p 2'-0" ALUMINUM WRAP <br />(S) A23 ALUMINUM SOFFIT <br />PT 2X4 LEDGER ATTACHED TO <br />WALL W/ 3116" TAPCONS W/ <br />MIN 2-1/2" EMBEDMENT 6" O.C. <br />BTM AT T-6" <br />SOFFIT DETAIL <br />10 <br />3/411= 11-011 <br />PT 2X8 LEDGER ATTACHED TO WALL <br />W/ 3/8" X 5" TITEN HD AT 12" O.C. <br />STAGGERED <br />N o 0 0 <br />0 0 <br />"8- 1'-01, 1'-01, 1'-01, 1'-01, <br />LEDGER DETAIL <br />11 <br />3/411 = <br />- 11 <br />4" STUCCO <br />BAND <br />WEEP <br />SCREED —� <br />C9 <br />o W <br />N = <br />_z <br />2 1'-( <br />4" STUCCO <br />BAND <br />5/8" <br />STUCCO <br />OVER <br />MASONRY- <br />----------------- <br />CASING BEAD <br />7/8" STUCCO WITH WEEP <br />OVER FRAME SCREED OVER <br />FLASHING <br />8 <br />A5 <br />12 <br />5� ` <br />FRONT ELEVATION B <br />U1/411 = 1 11_0111 <br />ELEV AT 8'-8" <br />T.O.M. `r <br />-- MID WALL <br />WEEP SCREED <br />5/8" STUCCO <br />�- OVER <br />MASONRY <br />ELEV AT 0'-0" <br />1 ST FLOOR FF <br />`-GRADE LINE <br />DIR(EAR ELEVATION B <br />1 /8" = 1 '-019 <br />SHINGLE <br />ROOF <br />12 <br />v <br />r. <br />_ - ELEV AT 18'-0" <br />t T.O.P. <br />V-0" <br />CASING BEAD WITH <br />WEEP SCREED OVER <br />FLASHING <br />ELEV AT 10'-0" <br />2ND FLOOR FF <br />_ ELEV AT 8'-8" <br />T.O.M. <br />WEEP SCREED <br />r nuu�um■um�um�luu�um�um�um�lnu�t��u�luu�luu�l�m�nm�luu�uu��l�u��luu�um�luu�um�um�um�u.� <br />I� ml�i�m�mn�mrlm_n��l�nlrmrl�m_.ri�i�m�ur!u■ir�n�i�nl■Inu�lml�i�rlu�mn�iml�l�m�imi�len��in�l�uirl�i���l�l�nl�i�ELEV AT , <br />T.O.P. <br />W : <br />lun■Inni ■ <br />ELEV AT 0'-0" Adk <br />1ST FLOOR FF <br />CONTROL JOINT <br />z <br />OVER FRAME <br />CONTROL JOINT <br />2ND FLOOR FF <br />- - - <br />- <br />- <br />- - - <br />- <br />ELEV AT 8'-8" <br />OIL <br />%/8" STUCCO <br />T.O.M. <br />OVER <br />MASONRY <br />MID WALL <br />WEEP SCREED <br />A/C UNIT <br />AND PAD <br />ELEV AT 0'-0" <br />1 ST FLOOR FF <br />RIGHT ELEVATION B <br />GRADE LINE <br />1 /811 = 1'-01 <br />1 <br />ELEV AT 18'-0" <br />- - - - <br />- - - - - - <br />- - - - T.O.P. <br />12'-0" <br />13'-4" 12'-0" <br />o w C,� <br />7/8" STUCCO <br />OVER FRAME <br />ELEV AT 10'-0" <br />z <br />2ND FLOOR FF <br />JOINT <br />12CONTROL <br />51—i <br />ELEV AT 8'-8" <br />T.O.M. <br />A/C UNIT <br />�5/8" STUCCO <br />AND PAD ' 2'4 <br />- OVER <br />MID WALL <br />MASONRY <br />WEEP SCREED <br />' <br />ELEV AT 0'-01, <br />- - - - <br />- - - - - - <br />- - - <br />1ST FLOOR FF <br />GRADE LINE <br />ELEVATION B <br />I�LEFT <br />AY 7, 4 2022 <br />VIRTUAL REVIEW ASSIST <br />Virtual Review Assist, Inc. <br />Plans Review completed and approved <br />for compliance with the 2020 FBC 7th <br />Edition by Debra. Anne Klahr PX2300 <br />MM <br />15'-9" 7'-4" 6'-11" <br />0 <br />-----� -- <br />SLOPE <br />5:12 <br />SLOPE <br />5:12 <br />W <br />a <br />ON <br />J 77 <br />U)Lo <br />/ 10'-0" R <br />/ VENT <br />— <br />6'-0" RIDGE <br />VENT <br />I <br />SLOPE <br />5:12 <br />L— Tit -- <br />1 /811= 11_01 U 1 /811= 11-011 <br />T-0" RIDGE <br />VENT <br />SLOP <br />5:12 <br />I <br />I <br />W SLOPE SLOPE I <br />OJ 77 5:12 5:12 <br />cn Lo I I <br />I <br />— — — —j <br />SLOPE <br />— Co <br />FLASHING NOTES: <br />DUE TO CLARITY NOT ALL REQUIRED FLASHING ARE <br />INDICATED ON DRAWINGS. REFER TO FBC RES 2020 (7TH <br />EDITION), SECTION R703.4. AND R903.2 APPROVED <br />CORROSION -RESISTIVE FLASHING SHALL BE PROVIDED AT <br />ALL ROOFING SYSTEM INTERRUPTIONS, TERMINATIONS, <br />INTERSECTIONS, AND PENETRATIONS AND IN THE <br />EXTERIOR WALL ENVELOPE IN SUCH A MANNER AS TO <br />PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR <br />PENETRATION OF WATER TO THE BUILDING STRUCTURAL <br />FRAMING COMPONENTS. THE FLASHING SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL FINISH AND <br />SHALL BE INSTALLED TO PREVENT WATER FROM <br />REENTERING THE EXTERIOR WALL ENVELOPE. APPROVED <br />CORROSION -RESISTANT FLASHING SHALL BE INSTALLED <br />AT ALL OF THE FOLLOWING LOCATIONS: <br />1. AT TOP OF ALL EXTERIOR WINDOW AND DOOR <br />OPENINGS IN SUCH A MANNER AS TO BE LEAK PROOF, <br />EXCEPT THAT SELF -FLASHING WINDOWS HAVING A <br />CONTINUOUS LAP OF NOT LESS THAN 1-1/8 INCHES (28 <br />MM) OVER THE SHEATHING MATERIAL AROUND THE <br />PERIMETER OF THE OPENING, INCLUDING CORNERS, DO <br />NOT REQUIRE ADDITIONAL FLASHING; JAMB FLASHING <br />MAY ALSO BE OMITTED WHEN SPECIFICALLY APPROVED <br />BY THE BUILDING OFFICIAL. <br />2. AT THE INTERSECTION OF CHIMNEYS OR OTHER <br />MASONRY CONSTRUCTION WITH FRAME OR STUCCO <br />WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER <br />STUCCO COPINGS. <br />3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR <br />METAL COPINGS AND SILLS. <br />4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD <br />TRIM. <br />5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS <br />ATTACH TO A WALL OR FLOOR ASSEMBLY OF <br />WOOD -FRAME CONSTRUCTION. <br />6. AT WALL AND ROOF INTERSECTIONS. <br />7. AT BUILT-IN GUTTERS. <br />8. WHENEVER THERE IS A CHANGE IN ROOF SLOPE OR <br />DIRECTION. <br />9. AT ROOF CRICKET OR SADDLE. <br />10. AROUND ROOF OPENINGS. <br />GENERAL FLASHING NOTES: <br />INSTALL FLASHING IN ACCORDANCE WITH FBC RES 7TH <br />EDITION (2020), SECTION R703.4 AND IN ACCORDANCE <br />WITH STANDARD APPLICATIONS ILLUSTRATED IN THE <br />ARCHITECTURAL SHEET METAL MANUAL (LATEST <br />EDITION) AS PUBLISHED BY THE SHEET METAL AND AIR <br />CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION, <br />INC. <br />WINDOW NOTE: <br />ALL NEW WINDOWS MUST MEET A MINIMUM 'U'-VALUE OF <br />0.4 OR LESS AND A'SHGC' OF 0.25 OR LESS. (UTILIZING <br />THE PRESCRIPTIVE METHOD FOR EXISTING STRUCTURES) <br />EGRESS NOTE: <br />EACH BEDROOM MUST HAVE ONE WINDOW THAT <br />COMPLIES WITH EGRESS CODES, IF THERE IS NO ACCESS <br />TO EXTERIOR THROUGH A DOOR. THE WINDOW MUST <br />HAVE A MAXIMUM SILL HEIGHT OF 44" ABOVE FINISH <br />FLOOR LINE OF THAT PARTICULAR ROOM <br />SHINGLE / UNDERLAYMENT NOTE: <br />ASPHALT SHINGLES ARE IN ACCORDANCE WITH TABLE <br />R905.2.6.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />SHINGLE UNDERLAYMENT SHALL COMPLY WITH SECTION <br />905.1.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />GENERAL FINISH NOTES: <br />APPLICATION OF STUCCO (EXTERIOR PLASTER) <br />MUST BE IN ACCORDANCE WITH FBC R703.7, <br />ASTM C926 AND C1063 <br />ALL LATH AND LATH ATTACHMENTS TO BE OUT OF <br />CORROSION -RESISTANT MATERIAL. (REFER TO SHEET SN1 <br />FOR THE ENGINEERED METHOD FOR LATH ATTACHMENT) <br />ROOF GENERAL NOTES: <br />* G.C. VERIFY ROOF PITCH <br />ROOF PITCH VARIES PER SUBDIVISIONS (5/12 PR 5.9/12) <br />IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF <br />SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. <br />ROOF CRITERIA <br />- 12" OVERHANG U.N.O. <br />- PLUMB CUT FASCIA <br />- ROOF PITCH PER ELEVATION <br />- WINDLOAD CALC. PER ASCE 7-98 (VARIES BY LOCATION) <br />- SHINGLE LOADING <br />ROOF VENT CALCULATIONS: <br />NOTE: VERIFY WITH GENERAL CONTRACTOR ALL ROOF VENT <br />LOCATIONS, QUANTITIES, AND SIZES. ROOF VENTS SHALL BE <br />INSTALLED FOR A MIN. OF VENTED AREA AS LISTED BELOW OR <br />EQUIVALENT SYSTEM PER 7TH EDITION (2020) FBC, SECTION R806 <br />FORMULA = S.F. 1300 (1/300) " 144 (TO CONVERT TO SQ. INCHES) _ <br />NET SQ. INCH REQUIREMENT <br />ATTIC AREA 1 = 1268 SQ FT <br />VENTILATION REQUIRED = 609 SQ IN <br />VENTILATION PROVIDED AT RIDGE = 306 SQ IN <br />VENTILATION PROVIDED AT SOFFIT =1197 SQ IN <br />ATTIC AREA 2 = 445 SQ FT <br />VENTILATION REQUIRED = 214 SQ IN <br />VENTILATION PROVIDED AT RIDGE = 108 SQ IN <br />VENTILATION PROVIDED AT SOFFIT =425 SQ IN <br />ATTIC VENTILATION <br />ATTIC VENTILATION TO BE IN COMPLIANCE WITH THE FLORIDA <br />BUILDING CODE 7TH EDITION (2020) RESIDENTIAL R806. <br />THE MINIMUM NET FREE VENTILATING AREA SHALL BE 1/150 OF THE <br />AREA OF THE VENTED SPACE. THE VENTILATED AREA MAY BE <br />REDUCED TO 1/300 PROVIDED THAT AT LEAST 40% BUT NO MORE <br />THAN 50% OF THE REQUIRED VENTILATION IS PROVIDED IN THE <br />UPPER PORTION OF THE SPACE TO BE VENTILATED. UPPER <br />VENTILATORS SHALL BE LOCATED NO MORE THAN 3 FEET (MEASURE <br />VERTICALLI) BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, <br />WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY <br />EAVE OR CORNICE VENTS. <br />CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN. <br />(VALUES TO BE VERIFIED WITH MANUFACTURER SPECIFICATIONS) <br />* RIDGE VENTS - 18 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />* OFF -RIDGE VENTS - 138 SQ. IN. OF NET FREE AREA / UNIT <br />* SOFFIT VENTS - 7 SQ. IN. OF THE NET FREE AREA / SQ. FT. <br />IF NOT ENOUGH VENTED SOFFIT IS PROVIDED DUE TO FIRE <br />PROTECTION, THE CONTRACTOR SHALL USE DECK -AIR OF OTHER <br />APPROVED MATERIAL TO PROVIDE SUFFICIENT IN -TAKE VENTILATION <br />* LOMANCO DECK -AIR - 9 SQ. IN. OF NET FREE AREA / FT. FOR SHINGLE <br />36 SQ. IN. OF NET FREE AREA / FT. FOR TILE <br />NOTE: <br />EXTERIOR WINDOWS, SLIDING DOORS AND EXTERIOR SIDE -HINGE <br />DOORS SHALL BE TESTED AND LABELED WITH A PERMANENT LABEL <br />PROVIDING TRACE ABILITY TO MANUFACTURER AND PRODUCT <br />' <br />N <br />N <br />a .; �b` y <br />6k., 'm0 Z a <br />o <br />N <br />4sa <br />YY <br />o <br />00 <br />LID <br />� A� 01 g0 d$ ' <br />a <br />w <br />Q <br />^N > o ^ o <br />W L '= �O c2 U <br />, MN 5 <br />V) V -0 M <br />s✓ L 0 <br />�rn � O 2 <br />O LL Q <br />d } < <br />'V) V W a! <br />Mo <br />W L. E m2) <br />W W <br />LLi w lo- <br />W~ w�22 <br />W J IO Z <br />,(9 <br />Q Q V?pXJWpZmp❑�Q� <br />xO02",oaUOJO <br />U <br />I- I- <br />00 <br />a )0,OZZOF00mZz <br />u)LUaWv5wwFinWXap� <br />U) 0 Z <br />III LUwoWcv�°¢ <br />¢~<U_ <br />ow YZ a <br />OLL Q ❑ =O ❑FQ� <br />i <br />O <br />O <br />N <br />Z <br />O I— <br />/ V! O <br />Q F: M O <br />Q (/) M � <br />(j) LL ti <br />Q W Q L0 <br />�WcCCM <br />00 <br />Q <br />Q <br />Z U H <br />z <br />W <br />W <br />J O <br />Mj <br />N <br />N <br />0 <br />CV <br />ti <br />N <br />o <br />0 <br />co <br />06 <br />v <br />o <br />N <br />0 <br />0 <br />N <br />N <br />O <br />O <br />N <br />CN <br />N <br />N 0 <br />N <br />0 <br />N <br />N <br />0 <br />N <br />C7 <br />N <br />N <br />ob <br />O <br />L6 <br />r <br />00 <br />CDN <br />M <br />O <br />M <br />co <br />�t <br />o <br />co <br />rn <br />o <br />o <br />o <br />r- <br />0 <br />co <br />0 <br />r� <br />c <br />'cLn <br />0U-) <br />; <br />o <br />0 <br />CV <br />0 <br />cM <br />0 <br />It <br />0 <br />In <br />0 <br />Cfl <br />0 <br />f­ <br />vJ <br />Z <br />z O <br />z <br />O <br />WUt~-- <br />Win <br />LU <br />� <br />}_i <br />O <br />vo�< <br />M <br />a <br />W <br />-0 <br />Lr)V <br />J <br />z <br />W F_ <br />�M0z <br />(� <br />Z <br />[V <br />0 <br />i'ZZLL <br /><�0 <br />r7 <br />�QQI- <br />LL <br />(� <br />w N <br />OJ2z <br />r <br />Ua>- <br />W <br />Z <br />Ea0 <br />• <br />Z <br />U <br />� <br />OU <br />O <br />W <br />a <br />z <br />Z <br />z <br />W <br />J <br />N <br />N <br />W <br />LAST PLOT DATF <br />O <br />Apr. 11, 22 <br />Z <br />EXTERIOR <br />J <br />ELEVATIONS B & <br />ROOF PLAN <br />