Laserfiche WebLink
ELEC <br />METER <br />FIRST FLOOR ELECTRICAL PLAN B <br />1 /411 = 1'-011 <br />SECOND FLOOR ELECTRICAL PLAN B <br />1 /4" = 1'-011 <br />1 IP.IC !lC O/l/lC <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2"AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />200A INDOOR PANEL <br />CENTER <br />00 <br />#15 copper to lights & outlets <br />1 <br />00 AMP <br />200 <br />#12 copper to 20 amp ckts <br />NO <br />#10-2 copper to WH <br />00-1 <br />#10-3 copper to Dryer <br />METER <br />2/0 or 4/0 SER Alu <br />MAIN <br />O <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />1 T <br />R ` <br />VIRTUAL REVIEW ASSIST <br />Virtual Review Assist, I <br />MififfeTalloWARMOR _ 11. <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />io <br />SWITCH ° <br />4 1/2 <br />DOORJAMB DUPLEX <br />OUTLET ih <br />TRIM o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oz <br />kS <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />E)= 110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />® TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />6- SWITCH AT 36" <br />6 3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-p PUSH BUTTON FOR GARAGE DOOR OPENER <br />-� DIMMER SWITCH AT 36" <br />-{] PUSH-BUTTON DOORBELL <br />CLG MNT LT FIXTURE <br />B CLG MNT PREWIRE - FIXTURE BY OWNER <br />SURFACE MNT FIXTURE <br />�- WALL MNT FIXTURE <br />NOTE: <br />ND OPALEX - ALTERNATE <br />TUB/SHOWERCANS MAY BE <br />USEDIF <br />O 50W PAR30 NFL 6" WHITE BAFFLE APPROVED BY <br />Q 50W MR16 4" LOW VOLTAGE OWNER <br />50W PAR20 NFL 4" MINI ROUND RECESS <br />50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cs SMOKE DETECTOR <br />O SMOKE DETECTOR <br />-U-18= UNDER CABINET 18" <br />=S-18- SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />-S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 — UNDER CABINET 36" <br />S-36 — SINGLE 36" FLUOR STRIP <br />D-36 — DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />9�: 24 24" VANITY LIGHTING <br />F,—= 36 :im-� 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />O EXHAUST FAN/LIGHT <br />® EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />15OW PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />® CEILING MNT SPEAKER <br />® CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />ELEC PANEL <br />®V VACUM OUTLET AT 12" <br />WA CEILING RETURN AIR <br />CS A/C REGISTER <br />OT THERMOSTAT <br />® SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />E+ <br />^N <br />W <br />> (D K o <br />L '0 '? 0 <br />N M <br />N N <br />� <br />N <br />V a <br />A' <br />W � O 2 O <br />-L <br />o <br />O u o Q <br />�N <br />}4t <br />W <br />co <br />M <br />W <br />L O rNi <br />O� <br />r— a a <br />V) <br />LU <br />(D <br />W <br />C] <br />-j <br />Q W <br />�� <br />QJ�O�rfWLL00wO <br />w0~w <br />WQ w <br />zW <br />of YOJZ <br />Q <br />V <br />0x()W <br />(3 <br />OZMO0E- <br />zz <br />wow9ozoE00oo <br />w <br />QpW ozWzO <br />QesQ! <br />�OZa—www5�WW <br />a <br />Q <br />0::)0Qz <br />0 <br />Q <br />Qw <br />wQ <br />O <br />N <br />z W <br />O I— <br />i (= O <br />M <br />O <br />Q U) CM <br />� <br />U LL � <br /><C W Q Lr? <br />M <br />Q U Q 00 <br />z <br />W <br />W <br />JC:) <br />O <br />d' <br />N <br />N <br />O <br />N <br />ti1 <br />N <br />1 <br />O <br />O< <br />00 <br />(D <br />00 <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />N <br />N <br />O <br />O <br />N <br />.O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />CV <br />'00 <br />0 <br />U) <br />00 <br />O <br />t7 <br />N <br />CD <br />M <br />co <br />d- <br />O <br />r- <br />O <br />rn <br />O <br />O <br />r <br />O <br />0 <br />(0 <br />0 <br />' <br />O <br />•L <br />0 <br />o L <br />L(, <br />; <br />O <br />LO <br />`i N <br />0 <br />M <br />0 <br />d' <br />0 <br />to <br />0 <br />(fl <br />0 <br />I�- <br />�— <br />Cr <br />M <br />w <br />v, <br />Z <br />z LD <br />OW <br />W I; <br />O <br />U0-a <br />it <br />i <br />`.V) <br />IIIl— Q <br />z <br />X H <br />Q <br />W O z <br />l!=nn�-=z <br />V <br />J <br />N <br />z <br />Z <br />0y� <br />MW <br />l <br />Z <br />CM <br />W fV <br />O <br />1 z <br />z <br />U <br />�- U) <br />Q0 <br />■ ■ <br />U <br />Z <br />� <br />U <br />CL <br />O <br />O <br />W <br />Q <br />z <br />Z <br />z <br />w <br />J <br />W <br />N <br />N <br />LAST PLOT DATE <br />> <br />. . <br />Apr. 11„ 22 <br />Z <br />0 <br />1ST & 2ND FLOOR <br />� <br />ELECTRICAL PLAN <br />B <br />