My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6489 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6489 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 4:58:26 PM
Creation date
2/19/2025 8:28:39 AM
Metadata
Fields
Template:
Building Plans
Street #
6489
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELEC <br />METER <br />PANTRY 'GFI GFI' <br />v �\ <br />/ o <br />GFI ,4 4 <br />GFI AT <br />i 30" A. F. F. _ TV <br />GFI 7D_W <br />-HDMI <br />61:4 LIVING <br />ROOM <br />GFIGFI30"4'-3" I <br />GFI KITCHEN <br />6'-0" <br />FI A <br />¢ `° LL <br />G F <br />o <br />fD A <br />F <br />DINING <br />UTILITY ROOM F ° o ° <br />GFI PW_D_R\_ <br />WH \ F_BATH <br />ELEC \ 2'-11" <br />PANEL 157 <br />Z) <br />�`J <br />TWO CAR GARAGE 1 <br />I <br />48 GFI o <br />iv SS TO 2ND <br />GFI LR ELE <br />GFI <br />110V CLG <br />MNT. i <br />— — — OUTLET <br />AV I <br />N <br />3 � <br />o <br />- <br />4 _9 <br />c_1 ! 4' <br />2'-6„ <br />Ji GFI ENTRY <br />WP--- <br />_ _ <br />F_ <br />L——— — — — — —— <br />— —J <br />FIRST FLOOR ELECTRICAL PLAN (ELEVATION B <br />1 /411 = 1 1_011 - - -- <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A. FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST 3' FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN 44" AFF <br />BATHROOM 39" AFF <br />LAUNDRY ROOM 36" AFF <br />EXTERIOR WATERPROOF 12" AFF <br />GARAGE GENERAL PURPOSE 42" AFF <br />RANGE 2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & S;ZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />METER 2/0 or 4/0 SER Alu <br />MAIN V. <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />�— 4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to rooter steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />SWITCH ° <br />DOORJAMB DUPLEX <br />OUTLET <br />TRIM — <br />BASE --- <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oz <br />k—SMOKE <br />r2 <br />IV DETECTOR <br />1'-0" <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />E)=r 110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />' TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />0 STRUCTURED WIRE OUTLET <br />6 SWITCH AT 36" <br />6 3 WAY SWITCH AT 36" <br />-ei—:' 4 WAY SWITCH AT 36" <br />—0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />--a DIMMER SWITCH AT 36" <br />—0 PUSH-BUTTON DOORBELL <br />CLG MNT LT FIXTURE <br />CLG MNT PREWIRE - FIXTURE BY OWNER <br />SURFACE MNT FIXTURE <br />-�- WALL MNT FIXTURE <br />NOTE: <br />C TUB/SHOWERND OPALEX - ALTERNATE <br />CANS MAY BE <br />40 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />C 50W MR16 4" LOW VOLTAGE OWNER <br />C 50W PAR20 NFL 4" MINI ROUND RECESS <br />50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />F CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cs SMOKE DETECTOR <br />C SMOKE DETECTOR <br />cU-18= UNDER CABINET 18" <br />rS-182 SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />FF24:R 24" VANITY LIGHTING <br />F;—= 36 ;;R 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />Q EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />E3 CHIMES (DELETE W/ INTERCOM) <br />ME93- MASTER STATION <br />ELEC PANEL <br />VACUM OUTLET AT 12" <br />® CEILING RETURN AIR <br />A/C REGISTER <br />OT THERMOSTAT <br />EM SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />0 O u7 F <br />-0 <br />W L q U <br />cy) N d <br />� <br />+- } V } <br />L � O <br />g <br />O U_ 8 Q <br />�!! <br />. W V) <br />W L oc)o Ew <br />0 <br />� 0 ��CL <br />W <br />Wj U W O I— <br />H� 0 xg~z� <br />¢ z <br />0Z2JO0�Q0 <br />< Q <br />Q <br />V <br />?CYXQZ�0 0 <br />0v��ixozowoomz <br />(n W W A W W0� <br />Z <br />EL <br />~OZ ¢W¢ZWWU¢ <br />H- <br />❑OQ <br />Q <br />LL <br />O W V2 <br />O =i5Yz <br />Q <br />LL O¢I, <br />O <br />Z <br />W <br />OI_ <br />�(�O <br />��MOIO <br />QWQLq <br />Z U <br />W <br />W <br />J O <br />M <br />O <br />1 <br />2023 <br />Virtual <br />Review <br />fissis <br />, <br />Plans Reviev <br />co <br />pliet <br />d' <br />ial <br />p ve <br />for compliance <br />ith <br />the 20 <br />B <br />t <br />o <br />111 <br />by Debr <br />An <br />a Kt <br />hr 112Z <br />O <br />I <br />I <br />N <br />N <br />N <br />� <br />N <br />N <br />N <br />M <br />N <br />o <br />0 <br />0 <br />0 <br />0 <br />0 <br />CDN <br />O <br />00 <br />CDo <br />O <br />0 <br />N <br />0 <br />' <br />Z <br />O <br />N <br />U-) <br />'W w <br />o <br />CD <br />0 <br />00 <br />> <br />N <br />C'M <br />4 <br />to <br />(O <br />I <br />M� <br />W <br />VJ <br />Z~ <br />z Z <br />C) <br />W <br />z� <br />zz <br />O <br />()00 <br />U <br />^ <br />O <br />ow'>_ <br />Q <br />Z <br />a�a <br />�— <br />�WQ <br />rl <br />m[tw <br />('V <br />�O <br />N <br />zo= <br />W <br />W <br />Q�� <br />■ <br />Ln <br />Q <br />p <br />zwo <br />0 <br />CU <br />w <br />azLL <br />Z <br />M <br />r <br />� <br />Z <br />?� <br />pL) <br />_o <br />W <br />z <br />z <br />z <br />z <br />w <br />W <br />J <br />O04 <br />0 <br />LAST PLOT DATE <br />O <br />z <br />O <br />1ST FLOOR <br />ELECTRICAL PLAN B <br />- -: �,_ -,r�T.:-, -rr r e,:r:.: i __T_ i [III r _i nnr t <br />-- <br />
The URL can be used to link to this page
Your browser does not support the video tag.