ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />SECOND FLOOR ELECTRICAL PLAN (ELEVATION A&B' <br />1 /411 = 1'-011 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />co <br />SWITCH—° <br />4 1/2" <br />DOORJAMB DUPLEX <br />OUTLET <br />TRIM o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />o Z <br />IL —SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />Cr 110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />�! FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />�} TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />-69 SWITCH AT 36" <br />�- 3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />—0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />—o DIMMER SWITCH AT 36" <br />PUSH-BUTTON DOORBELL <br />CLG MNT LT FIXTURE <br />{�- CLG MNT PREWIRE - FIXTURE BY OWNER <br />-�- SURFACE MNT FIXTURE <br />-� WALL MNT FIXTURE <br />NOTE: <br />OPALEX - <br />C <br />ALTERNATE <br />TUB/SHOWERND <br />CANS MAY BE <br />4� 50W PAR30 NFL 6" WHITE BAFFLE <br />C <br />USED IF <br />APPROVED BY <br />C 50W MR16 4" LOW VOLTAGE <br />OWNER <br />1 50W PAR20 NFL 4" MINI ROUND RECESS <br />�� 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />} CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cs SMOKE DETECTOR <br />C SMOKE DETECTOR <br />cU-18= UNDER CABINET 18" <br />=S-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 —^ SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />5724:P 24" VANITY LIGHTING <br />F_— 36 ;;;;3 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />ELEC PANEL <br />VACUM OUTLET AT 12" <br />WAI CEILING RETURN AIR <br />E3 A/C REGISTER <br />OT THERMOSTAT <br />SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />/cam <br />N LO <br />L <br />W <br />L �0 q U <br />co ti <br />t <br />N <br />V CO <br />w M <br />om <br />O oo 2 o <br />TSB •� p U- o Q <br />Ln <br />p � � <br />u LU Q N c <br />W <br />L � E <br />CL a <br />C7 WZ) <br />W <br />LW H W J W M O, O <br />I— < 0� x <br />- � <br />�_O2LL0 LL <br />�Q <br />~ <br />�wZ <br />Q0LLO�¢¢ZOZ200F�- <br />OowO <br />WWLJV5WZ <br />Q~V <br />wz�oWQQ <br />220QQW H �LL <br />O x 5 Q <br />QLL <br />Q <br />LL.Q O <br />O <br />Z CNI <br />O� <br />U ti <br />0 F_: cM O <br />Q w M r- <br />�U)�� <br />i— W M <br /><Ua00 <br />Z <br />W <br />W <br />J� <br />O <br />JUL <br />1 <br />121123 <br />Virtual Rev <br />w <br />ssis <br />, Inc. <br />Plans Review co <br />let <br />d ar <br />d ap <br />ro <br />d <br />compliance <br />with <br />e 2 <br />12D <br />BC <br />th! E <br />J itio <br />III y Debra An <br />O <br />O <br />N <br />O <br />cM <br />O <br />LO <br />O <br />N <br />O <br />N <br />0 <br />Iq <br />N <br />N <br />O <br />o <br />O <br />� <br />O <br />� <br />0 <br />o <br />N <br />0 <br />N <br />o <br />' <br />I <br />Z <br />O <br />NLo <br />W <br />o <br />0 <br />0 <br />0 <br />0 <br />0 <br />l <br />LO <br />Nt <br />> <br />N <br />M <br />Ln <br />CO <br />i <br />CO <br />VJ <br />z~ <br />QZ <br />C <br />W <br />z� <br />000 <br />O <br />U <br />Uzi <br />F_ <br />r)z- <br />LO <br />-0 <br />O <br />of-0 <br />Z <br />a�(a <br />11.0 <br />f— <br />x < <br />rl <br />= <br />m�W <br />N <br />H2 <br />0 <br />N <br />ZOM <br />�- <br />QF-:) <br />Ln <br />Q <br />O <br />zoo <br />O <br />V <br />JWLL <br />Z <br />M; z <br />� <br />Z <br />F� <br />pU <br />IZ <br />_o <br />W <br />z <br />Z <br />w <br />� <br />wc) <br />J <br />0 <br />T_ <br />LAST PLOT DATE <br />O <br />. . <br />May 9, 2023 <br />4_j <br />Z <br />O <br />2ND FLOOR <br />J <br />ELECTRICAL PLAN <br />A&B <br />