My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6506 Beverly Hills Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6506 Beverly Hills Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 9:07:27 PM
Creation date
2/19/2025 8:30:15 AM
Metadata
Fields
Template:
Building Plans
Street #
6506
Location
Beverly Hills Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
5150
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
rELECTRICAL SPECIFICATION <br />II NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan Is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories, <br />5. Smoke detectors shall be in accordance With R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI LIL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided With a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would Include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges Installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />PE�G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />�94 <br />FOUR-WAY SWITCH <br />jR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />et>� <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />;Q <br />EXHAUST FANLIGHT COMBINATION <br />® <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />& <br />CHIMES (OPTIONAL) <br />1P <br />PUSH BUTTON SWITCH (OPTIONAL) <br />19 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />®2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />owl <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />150AI200A INDOOR <br />PANEL CENTER <br />200 amp <br />150 amp <br />UNDERGROUND IDIs <br />SERVICE BY POWER CO. <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />*14 to lights & outlets <br />#12 to appliances and GFI <br />d10 to WH <br />08 to Range <br />N6 to HVAC <br />200=410 in 2" Conduit <br />4 Bare Cu Ground <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />i <br />AC PAD AC PAD <br />DISC. <br />WP <br />GFI <br />PATIO <br />WP <br />GFI <br />H.B. <br />I I <br />/ I I <br />/ I I <br />` / I <br />FAMILY ROOM--, � <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRED <br />L <br />.. <br />TO LIGHT <br />AND <br />SWITCH <br />ABOVE <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />12 <br />EX <br />I <br />I <br />7- <br />FOYER <br />db <br />O / I <br />—, <br />W.H. <br />PENDANT AS / CH <br />\PER SPECS / <br />DINI0#00 f <br />F1 GFI I <br />I L---- 6UC _J <br />f— L---- ------ <br />n7dihFit <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />GFI 1 1 ... <br />k-ITCH—E-NI`, <br />REF. J� 90 <br />--- — OPT.— <br />G'FI @ 44" <br />A.F.F. <br />------------ <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I I I I <br />GFI @ 44" GAR. I I I <br />A.F.F. DOOR I I I <br />GFI <br />I I I I <br />I I I I <br />I I I <br />I I I <br />I I I I <br />I I I I <br />I I I I <br />I I I I <br />I I I I <br />I I I I <br />VERIFY LOCATION IRRIGATION <br />ELECTRICAL PANEL GFI �t�" A.F.F. <br />I <br />I <br />_I <br />VERIFY METER LOCATION WP <br />WITH BUILDER GFI H.B. <br />15'-0" <br />U <br />2 CAR GARAGE <br />r , I <br />� JI <br />I I <br />- 1IIN <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />ENTRY <br />MAIN FLOOR ELECTRICAL PLAN - ELEV-B1 <br />SCALE: Y4"=1'-0" <br />N <br />N <br />to <br />O <br />C) <br />aw <br />� t c <br />Clio <br />m w s <br />• c> apa <br />> <br />c o <br />� O •� T <br />_E <br />aG <br />c� <br />N <br />t` <br />N <br />LAD <br />0 <br />To the best of the Engineer's knowledge, Information and beUef, <br />the structural plans and spKAcatlons contained within these <br />drawings comply with the 2020 <br />Florida Building Code <br />- <br />Residendal <br />7th Edition, Engineer's signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />0yM� <br />to <br />0 J <br />(p LLLL ld' <br />a <br />Z <br />L `. _ a <br />LZ <br />cuo "N'0 dK <br />ZN <br />o0 C <br />W <br />❑ <br />z gN <br />z 3S <br />z <br />¢ $ <br />N <br />z <br />-J <br />N <br />0 <br />w <br />N <br />N <br />c �, <br />� <br />m <br />C) <br />¢ <br />0 <br />CD <br />soo <br />M <br />�pp <br /><R <br />o <br />wa <br />a <br />V3* <br />g <br />S <br />N <br />pp E49 <br />�g <br />i8 <br />ZN� <br />Jb <br />s <br />0Ig <br />5 <br />In <br />J <br />LO <br />�O <br />B <br />H <br />� <br />M <br />Y <br />� <br />T <br />.2 <br />m <br />LO <br />r <br />o <br />N <br />M <br />N <br />LO <br />o <br />z <br />c <br />m <br />E <br />E <br />ai <br />m <br />0. <br />U _j <br />< p <br />JOB <br />NO: <br />22-06457 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.0 <br />