My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6506 Beverly Hills Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6506 Beverly Hills Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 9:07:27 PM
Creation date
2/19/2025 8:30:15 AM
Metadata
Fields
Template:
Building Plans
Street #
6506
Location
Beverly Hills Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
5150
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom <br />39" AFF <br />Laundry Room <br />36" AFF <br />Exterior Waterproof <br />12" AFF <br />Garage - general purpose <br />44" AFF <br />Range <br />2"AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The Width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I .Ph <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />�4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />150A/200A INDOOR <br />PANEL CENTER <br />10 x14 to lights & oudets <br />NEMA 1 x 12 to appliances and GFI <br />150 AMP/ <br />ZOO AMP so #10 to WH <br />10 #& to Range <br />10 #6 to HVAC <br />METER IF <br />50=2/0 <br />200=4/0 In 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND InnfectSERVICE BY POWER CO. <br />INTERSYSTEM4 Bare Cu Ground <br />BONDING4 GROUNDING WIRE <br />TERMINATION PER WITH CODE APPROVED <br />NEC 17, 250.94 J CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />WALL MOUNTED LIGHT FIXTURE j <br />I <br />O RECESSED LIGHT FIXTURE I <br />I <br />P 0 LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT j <br />}� FLUORESCENT LIGHT FIXTURE I <br />O EXHAUST FAN L_ <br />EXHAUST FAN/LIGHT COMBINATION <br />RECEPT. <br />® ELECTRIC DOOR OPERATOR (OPTIONAL) FOR ALARM <br />CH CHIMES (OPTIONAL) SYSTEM — <br />FO PUSH BUTTON SWITCH (OPTIONAL) <br />�D PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />® TELEVISION (OPTIONAL) <br />®2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />C11�11 ELECTRIC METER <br />_tid ELECTRIC PANEL <br />_i...l <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE WI ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />ID <br />(1) PHONE LINE, (1) DATA PORT <br />r _ , <br />I I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I I <br />UPPER ELECTRICAL PLAN - ELEV-B1 <br />SCALE: /4"=V-0" <br />N <br />N <br />CQ <br />F— <br />U <br />d� <br />? W <br />W t <br />0 <br />m <br />'d X <br />..r c LA_ o_ <br />,— l9 <br />N <br />8 L c <br />� 3 � <br />io dj at <br />=der= <br />y cr to ?` <br />c E <br />ro v <br />d U <br />N <br />N <br />0 <br />N <br />ti <br />N <br />u->, <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and spedfications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature <br />and seal. <br />W <br />E <br />o $ <br />(0 <br />11 <br />N QpC7� <br />U <br />N <br />to <br />a <br />M v LL <br />LL <br />11 <br />0 <br />Z <br />� u__ d <br />32 <br />^gO1 a <br />j <br />W <br />CN O O <br />L <br />= <br />Z <br />CGo <br />N OU V <br />" <br />W <br />Cn <br />❑ ❑ <br />QD <br />Z <br />z E <br />U) <br />E3 <br />N <br />4J <br />z <br />� <br />"U <br />0 <br />N <br />L.0 <br />�N <br />G � <br />13 <br />U <br />• <br />Q N <br />Qc~ <br />c5 <br />M <br />�p <br />Y <br />t.L <br />E <br />H <br />QN <br />z0 <br />Z <br />EU <br />~ <br />to <br />5 <br />oa <br />a a <br />& o <br />a <br />� <br />¢¢QQ <br />p <br />WW <br />L <br />ro <br />rnC <br />- C <br />l <br />Y(yQ< <br />O <br />m <br />Z <br />} <br />Wj� <br />lb <br />N lb <br />�a <br />7 <br />g <br />0 <br />S23 <br />�I <br />$ <br />O <br />J <br />LO <br />rn <br />c� <br />Q <br />F -- <br />cM <br />co <br />j <br />04 <br />N <br />Y <br />� <br />�C <br />T <br />M <br />W <br />mLID <br />¢I <br />0 <br />N <br />O <br />N <br />LO <br />CN11.0 <br />Q <br />^ <br />r <br />m <br />E <br />co <br />N <br />U) <br />c <br />Z <br />z <br />E <br />E <br />d- <br />hi <br />c <br />ti <br />U <br />_j <br />$ p <br />JOB <br />NO: <br />22-06457 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.1 <br />