My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6614 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6614 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 7:31:13 PM
Creation date
2/19/2025 8:32:52 AM
Metadata
Fields
Template:
Building Plans
Street #
6614
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STUCCO ON FRAME - 7/8" 3-COAT SAND <br />FINISH STUCCO ON SELF FURRING LATH ON <br />FIBER CEMENT SIDING <br />2- LAYERS OF WATER RESISTIVE BARRIER <br />WALL SHEATHING PER PLAN <br />PER ELEVATIONS <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP)----- <br />STUCCO ON FRAME - 7/8" 3-COAT SAND <br />WALL SHEATHING PER PLAN ----- <br />WALL SHEATHING PER PL.AN---- <br />FINISH STUCCO ON SELF FURRING LATH ON <br />2- LAYERS OF WATER RESISTIVE BARRIER <br />SHINGLE WATER RESISTIVE <br />SHINGLE WATER RESISTIVE <br />BARRIER OVER FLASHING --------- <br />BARRIER OVER WEEP SCREED <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP) <br />WEEP SCREED <br />SHINGLE WATER RESISTIVE <br />STARTER <br />BARRIER OVER WEEP SCREED )/F <br />HOLD 1/4" AIR GAP <br />HOLD 1/4" AIR GAP <br />BETWEEN WEEP <br />WEEP SCREED <br />BETWEEN SIDING AND <br />SCREED AND FLASHING <br />'o <br />HOLD 1/4" AIR GAP <br />FLASHING <br />COUNTER FLASHING <br />BETWEEN WEEP <br />COUNTER FLASHING ----------- <br />SCREED AND FLASHING <br />CCNT SELF ADHERED FLASHING TO <br />CONT SELF ADHERED FLASHING TO <br />LAP FLASHING AND TURN 3" UP WALL <br />CONT SELF ADHERED FLASHING TO <br />LAP FLASHING AND TURN 3" UP WALL <br />LAP FLASHING AND TURN 3" UP WALL <br />FLASHING <br />FLASHING <br />PT lX10 BLOCKING <br />lo 11 <br />PT 1X BLOCKING <br />PT lX10 BLOCKING-----� <br />CONT SELF ADHERED FLASHING <br />COUNTER FLASHING <br />CONT SELF ADHERED FLASHING <br />TURN 3" UP BLOCKING <br />TURN 3" UP BLOCKING <br />00 <br />PAN FLASHING 6" MIN loll <br />MIN <br />CEMENT MORTAR <br />CEMENT MORTAR <br />ROOF UNDERLAYMENT TO <br />TILE ROOF PER SPECS <br />ROOF UNDERLAYMENT TO <br />TURN UP BLOCKING MIN 6" <br />CONT SELF ADHERED FLASHING <br />TILE ROOF PER SPECS ................... <br />ROOF UNDERLAYMENT ro <br />TURN UP BLOCKING MIN 8" <br />ROOF SHEATHING <br />TURN 3" UP BLOCKING <br />TILE ROOF PER SPECS-----______ <br />TURN UP BLOCKING MIN 8" <br />ROOF SHEATHING <br />PER PLAN---------- <br />PER PLAN---------- <br />2X NAILER SECURELY <br />FASTENED TO DECK - <br />ROOF SHEATHING <br />NOTE: PER PLAN ---------- <br />ALL LATH AND LATH <br />ATTACHMENTS TO BE <br />OUT OF CORROSION <br />-RESISTANT MATERIAL <br />HEAD WALL I RAKE WALL <br />I %a VVI-%L.L- - Ljr%FxFxL-L- I IL-L- I %-.# Q I U% .. f %-"# \a I - " '- <br />311=1 1-011 1 WP16 L A311= 1 1-011 <br />Qmwlli <br />NGLE ROOF PER SPECS <br />UNDERLAYMENT <br />TO SHINGLE OVER <br />DRIP EDGE <br />ROOF SHEATHING <br />PER PLAN <br />DRIP EDGE <br />2X6 SUB FASCIA <br />SELF ADHERED WRB TO <br />SHINGLE OVER WRB ON <br />WALL BELOW <br />ALUMINUM BRAKE METAL WRAP <br />CONT BACKER ROD <br />AND SEALANT <br />STUCCO'J'MOULDING <br />HOLD OFF BRAKE METAL <br />1/4" MIN <br />STUCCO ON FRAME - 7/8" <br />3-COAT SAND FINISH STUCCO <br />ON SELF FURRING LATH ON 2- <br />LAYERS OF WATER RESISTIVE <br />BARRIER COMPLYING WITH <br />ASTM E2556, TYPE 1 (TYP) <br />WALL SHEATHING PER PLAN <br />WP18 <br />WALL SHEATHING PER P <br />FIBER CEMENT SIDING <br />PER ELEVATIONS <br />SHINGLE WATER RESISTIVE <br />BARRIER OVER FLASHING - <br />STARTER STRIP - <br />HOLD 1/4" AIR GAP <br />BETWEEN SIDING AND <br />FLASHING <br />CONT SELF ADHtiRED FLASHING TO <br />LAP FLASHING AND TURN 3" UP WALL--,,,, <br />PT 1X BLOCKING ----- <br />COUNTER FLASHING <br />PAN FLASHING 6" <br />ROOF UNDERLAYMENT TO <br />TURN UP BLOCKING MIN 6"--, <br />CONT SELF ADHERED FLASHING <br />TURN 3" UP BLOCKING <br />TILE ROOF PER SPECS--- <br />HEAD WALL <br />2X NAILER SECURELY <br />FASTENED TO DECK - <br />ROOF SHEATHING <br />PER PLAN ---------- <br />FLASHING REQUIREMENTS <br />R730.1 GENERAL. EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A <br />WEATHER -RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR WALL ENVELOPE <br />SHALL INCLUDE FLASHING AS DESCRIBED IN SECTION R703.4. <br />R703.1 .1 WATER RESISTANCE. THE EXTERIOR WALL ENVELOPE SHALL BE DIMENSIONED <br />AND CONSTRUCTED IN A MANNER THAT PREVENTS THE ACCUMULATION OF WATER <br />WITHIN THE WALL ASSEMBLY BY PROVIDING A WATER-RESISTANT BARRIER BEHIND THE <br />EXTERIOR CLADDING AS REQUIRED BY SECTION R703.2 AND A MEANS OF DRAINING TO <br />THE EXTERIOR WATER THAT PENETRATES THE EXTERIOR CLADDING. <br />R7C3.2 WATER RESISTIVE BARRIER. ONE LAYER OF NO,15 ASPHALT FELT, FREE FROM <br />HOLES, COMPLY WITH ASTM D226 FOR TYPE 1 FELT OR OTHER APPROVED <br />WATER -RESISTIVE BARRIER SHALL BE APPLIED OVER STUDS OR SHEATHING OF ALL <br />EXTERIOR WALLS NO. 15 ASPHALT FELT SHALL BE APPLIED HORIZONTALLY, WITH THE <br />UPPER LAYER LAPPED OVER THE LOWER LAYER NOT LESS THAN 2 INCHES. WHERE <br />JOINTS OCCUR, FELT SHALL BE LAPPED NOT LESS THAN 6 INCHES. OTHER APPROVED <br />MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE WATER -RESISTIVE <br />BARRIER MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE NO.15 ASPHALT FELT <br />OR OTHER APPROVED WATER -RESISTIVE BARRIER MATERIAL SHALL BE CONTINUOUS <br />TO THE TOP OF WALLS AND TERMINATED AT PENETRATIONS AND BUILDING <br />APPENDAGES IN A MANNER TO MEET THE REQUIREMENTS OF THE EXTERIOR WALL <br />ENVELOPE AS DESCRIBED IN SECTION R703.1. <br />R703.7.3 WATER -RESISTIVE BARRIERS WATER -RESISTIVE BARRIERS SHALL BE <br />INSTALLED AS REQUIRED IN SECTION R703.2 AND, WHERE APPLIED OVER WOOD -BASED <br />SHEATHING, SHALL INCLUDE A WATER -RESISTIVE VAPOR -PERMEABLE BARRIER WITH A <br />PERFORMANCE AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. THE <br />INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH THAT EACH LAYER <br />PROVIDES A SEPARATE CONTINUOUS PLANE AND ANY FLASHING (INSTALLED IN <br />ACCORDANCE WITH SECTION R703.4) INTENDED TO DRAIN TO THE WATER -RESISTIVE <br />BARRIER IS DIRECTED BETWEEN THE LAYERS. <br />EXCEPTION: WHERE THE WATER -RESISTIVE BARRIER THAT IS APPLIED OVER <br />WOOD -BASED SHEATHING HAS A WATER RESISTANCE EQUAL TO OR GREATER <br />THAN THAT OF 60-MINUTE GRADE D PAPER AND IS SEPARATED FROM THE STUCCO <br />BY AN INTERVENING SUBSTANTIALLY NON -WATER -ABSORBING LAYER OR <br />DESIGNED DRAINAGE SPACE. <br />R703.4 FLASHING. APPROVED METAL FLASHING, VINYL FLASHING, SELF -ADHERED <br />MEMBRANES AND MECHANICALLY ATTACHED FLEXIBLE FLASHING SHALL BE APPLIED <br />SHINGLE -FASHION OR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. <br />METAL FLASHING SHALL BE CORROSION RESISTANT. FLUID -APPLIED MEMBRANES USED <br />AS FLASHING SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S <br />RAKE WALL INSTRUCTIONS. ALL FLASHING SHALL BE APPLIED IN A MANNER TO PREVENT THE <br />ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE <br />WP17 BUILDING STRUCTURAL FRAMING COMPONENTS. <br />SELF -ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH MMA 711. ALL <br />EXTERIOR FENESTRATION PRODUCTS SHALL BE SEALED AT THE JUNCTURE WITH THE <br />BUILDING WALL WITH A SEALANT COMPLYING WITH AAMA 800 OR ASTM C920 CLASS 25 <br />GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION, <br />ASTMC1281, MMA 812, OR OTHER APPROVED STANDARD AS APPROPRIATE FOR THE <br />TYPE OF SEALANT. FLLJID-APPLIED MEMBRANES USED AS FLASHING IN EXTERIOR <br />WALLS SHALL COMPLY WITH AAMA 714. THE FLASHING SHALL EXTEND TO THE SURFACE <br />OF THE EXTERIOR WALL FINISH. APPROVED FLASHINGS SHALL BE INSTALLED AT THE <br />FOLLOWING LOCATIONS: <br />1 . 1. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW <br />AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL <br />FINISH OR TO THE WATER -RESISTIVE BARRIER COMPLYING WITH SECTION 703.2 <br />FOR SUBSEQUENT DRAINAGE. MECHANICALLY ATTACHED FLEXIBLE FLASHINGS <br />SHALL COMPLY WITH MMA 712. FLASHING AT EXTERIOR WINDOW AND DOOR <br />OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR MORE OF THE <br />FOLLOWING: <br />1.1 THE FENESTRATION MANUFACTURER'S INSTALLATION AND FLASHING <br />INSTRUCTIONS, OR FOR APPLICATIONS NOT ADDRESSED IN THE <br />FENESTRATION MANUFACTURER'S INSTRUCTIONS, IN ACCORDANCE WITH <br />THE FLASHING MANUFACTURER'S INSTRUCTIONS. WHERE FLASHING <br />INSTRUCTIONS OR DETAILS ARE NOT PROVIDED, PLAN FLASHING SHALL BE <br />INSTALLED AT THE SILL OF EXTERIOR WINDOW AND DOOR OPENINGS. PAN <br />FLASHING SHALL BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT <br />WATER TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER <br />RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. OPENINGS USING PAN <br />FLASHING SHALL INCORPORATE FLASHING OR PROTECTION AT THE HEAD <br />AND SIDES. <br />1.2 IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A <br />REGISTERED DESIGN PROFESSIONAL. <br />1.3 IN ACCORDANCE WITH THE OTHER APPROVED METHODS. <br />1.4 IN ACCORDANCE WITH FMA/AAMA 100, FMA/AAMA 200, FMA/WDMA <br />250, FMA/AAMA/WDMA 300 OR FMA/AAMA/WDMA 400. <br />2.2 AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY <br />CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH <br />PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. <br />3.3 UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL <br />COPINGS AND SILLS. <br />4.4 CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. <br />5.5 WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A <br />WALL OR FLOOR ASSEMBLY OF WOOD -FRAME CONSTRUCTION. <br />6.6 AT WALL AND ROOF INTERSECTIONS. <br />7.7 AT BUILT-IN GUTTERS. <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />. \St <br />6 so <br />. \lea <br />C? S <br />$01 a mv(\ <br />C/) <br />> <br />0 <br />(D <br />c: <br />0 <br />0 <br />" <br />CL <br />cn <br />(D <br />r-- <br />L- <br />o <br />25- <br />—0 <br />a <br />cu <br />.0 <br />-6-4 <br />cu <br />u- <br />%+- <br />0 <br />cu <br />> <br />cn <br />E'a) <br />cu <br />0 <br />ca- <br />co <br />-0 <br />.0 <br />c: <br />— <br />-0� <br />c/) <br />z <br />w <br />mi <br />V <br />m� <br />cu <br />0 <br />0 <br />L. <br />LLI <br />CL <br />U) <br />co <br />0 <br />CD- <br />0 <br />CD <br />C/) <br />cu <br />m <br />1:1 <br />SHEET NO. <br />WP 2A <br />