My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6614 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6614 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 7:31:13 PM
Creation date
2/19/2025 8:32:52 AM
Metadata
Fields
Template:
Building Plans
Street #
6614
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TAPE EDGE OF HEAD <br />WALL FLASHING - <br />STUCCO ON FRAME - 7/8" <br />3-COAT SAND FINISH STUCCO <br />ON SELF FURRING LATH ON 2- <br />LAYERS OF WATER RESISTIVE <br />BARRIER COMPLYING WITH <br />ASTM E2556, TYPE 1 (TYP)— <br />WALL SHEATHING PER PLAN — <br />SHINGLE WATER <br />RESISTIVE BARRIER <br />OVER WEEP SCREED <br />WEEP SCREED— <br />CONT SELF ADHERED <br />FLASHING TURN 3" UP WALL- <br />18 GA HEAD WALL FLASHING <br />TO EXTEND MIN 8" BEYOND <br />UNDERLAYMENT <br />SHINGLE ROOF PER SPECS — <br />ROOF UNDERLAYMENT TO <br />TURN UP WALL MIN <br />ROOF SHEATHING <br />PER PLAN----------- <br />NOTE: <br />ALL LATH AND LATH <br />ATTACHMENTS TO BE OUT OF <br />CORROSION -RESISTANT MATERIAL <br />311= 1 1-011 <br />TAPE EDGE OFHEAD <br />WALL FLASHING — <br />STUCCO ON FRAME - 7/8" 3-COAT SAND <br />FINISH STUCCO ON SELF FURRING LATH ON <br />2- LAYERS OF WATER RESISTIVE BARRIER <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP' <br />WALL SHEATHING PER PLAN-------___ <br />SHINGLE WATER RESISTIVE <br />BARRIER OVER WEEP SCREED ---- <br />WEEP SCREED <br />HEAD WALL TRIM FLASHING TO <br />EXTEND MIN 8" BEYOND <br />UNDERLAYMENT <br />CONT SELF ADHERED <br />FLASHING TURN 3" UP WALL— <br />CONT BUTYL TAPE SEALANT PER <br />MANUFACTURER INSTALLATION <br />INSTRUCTIONS <br />7CLOSURE <br />STANDING SEAM METAL <br />ROOF PER SPECS <br />ROOF UNDERLAYMENT TO <br />TURN UP WALL MIN 8" <br />ROOF SHEATHING <br />PER PLAN <br />If= 1 1—ni, <br />!�T <br />;0 <br />z <br />00 <br />HEAD WALL <br />m <br />00 <br />amikNo 108� <br />STUCCO ON FRAME - 7/8" 3-COAT SAND <br />FINISH STUCCO ON SELF FURRING LATH ON <br />2- LAYERS OF WATER RESISTIVE BARRIER <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP: <br />WALL SHEATHING PER PLAN <br />SHINGLE WATER <br />RESISTIVE BARRIER <br />OVER WEEP SCREED <br />TAPE EDGE OF COUNTER <br />FLASHING <br />WEEP SCREED___,:__, <br />COUNTER FLASHING--, <br />CONT SELF ADHERED �X <br />FLASHING TURN 3" UP WALL__�� <br />SHINGLE PER SPECS --- <br />STEP FLASHING TO <br />EXTEND MIN 8" BEYOND <br />UNDERLAYMENT— <br />ROOF UNDERLAYMENT' <br />TURN UP WALL MIN 8"— <br />ROOF SHEATHING <br />PER PLAN <br />NOTE: <br />ALL LATH AND LATH <br />ATTACHMENTS TO BE OUT OF <br />CORROSION -RESISTANT MATERIAL <br />STUCCO ON FRAME - 7/8" 3-COAT SAND <br />FINISH STUCCO ON SELF FURRING LATH ON <br />2- LAYERS OF WATER RESISTIVE BARRIER <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP: <br />TAPE EDGE OF RAKE <br />WALL FLASHING <br />WALL SHEATHING PER PLAN-------_____ <br />SHINGLE WATER RESISTIVE <br />BARRIER OVER WEEP SCREED----__,..... <br />WEEP SCREED <br />RAKE WALL STEP FLASHING TO <br />EXTEND MIN 8" BEYOND <br />UNDERLAYMENT <br />FIELD BEND PANEL UP 1 1/2" <br />CONT BUTYL TAPE SEALANT 7PER <br />MANUFACTURER INSTALLATION <br />INSTRUCTIONS <br />'Z'CLOSURE 1\ <br />STANDING SEAM METAL <br />ROOF PER SPECS --------- <br />ROOF UNDERLAYMENT TO <br />TURN UP WALL MIN 8"-----, <br />ROOF SHEATHING <br />NOTE: PER PLAN <br />ALL LATH AND LATH <br />ATTACHMENTS TO BE CONT SELF ADHERED <br />OUT OF CORROSION FLASHING TURN 3" UP WALL <br />-RESISTANT MATERIAL <br />HEAD WALL <br />FLASHING REQUIREMENTS <br />R730.1 GENERAL. EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A <br />WEATHER -RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR WALL ENVELOPE cn <br />> <br />TAPE EDGE OF HEAD SHALL INCLUDE FLASHING AS DESCRIBED IN SECTION R703.4. <br />WALL FLASHING 0 <br />R703.1 .1 WATER RESISTANCE. THE EXTERIOR WALL ENVELOPE SHALL BE DIMENSIONED <br />FIBER CEMENT SIDING CD 0- <br />AND CONSTRUCTED IN A MANNER THAT PREVENTS THE ACCUMULATION OF WATER cL <br />FIBER CEMENT SIDING PER ELEVATIONS <br />cu <br />WITHIN THE WALL ASSEMBLY BY PROVIDING A WATER-RESISTANT BARRIER BEHIND THE <br />PER ELEVATIONS <br />WALL SHEATHING PER PLAN EXTERIOR CLADDING AS REQUIRED BY SECTION R703.2 AND A MEANS OF DRAINING TO <br />THE EXTE cu c/) <br />RIOR WATER THAT PENETRATES THE EXTERIOR CLADDING. cu <br />WALL SHEATHING PER PLAN 0 <br />W <br />SHINGLE WATER <br />SHINGLE WATER RESISTIVE BARRIER R703.2 WATER RESISTIVE BARRIER. ONE LAYER OF NO.15 ASPHALT FELT, FREE FROM c 2 a) <br />OVER FLASHING HOLES, COMPLY WITH ASTM D226 FOR TYPE I FELT OR OTHER APPROVED 0 cl c -2 3: <br />RESISTIVE BARRIER a <br />WATER -RESISTIVE BARRIER SHALL BE APPLIED OVER STUDS OR SHEATHING OF ALL 0 LL_ — <br />OVER FLASHING cu <br />TAPE EDGE OF COUNTER EXTERIOR WALLS NO. 15 ASPHALT FELT SHALL BE APPLIED HORIZONTALLY, WITH THE cu 0 <br />cu 0 > <br />FLASHING UPPER LAYER LAPPED OVER THE LOWER LAYER NOT LESS THAN 2 INCHES. WHERE <br />STARTER STRIP cn -0 E 2 <br />00 <br />JOINTS OCCUR, FELT SHALL BE LAPPED NOT LESS THAN 6 INCHES. OTHER APPROVED cn (1) CL <br />STARTER STRIP U) <br />CONT SELF ADHIERED MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE WATER -RESISTIVE 40-2 cu CL <br />ca 40 <br />FLASHING TURN 3" UP WALL BARRIER MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE NO.15 ASPHALT FELT -0 <br />COUNTER FLASHING <br />-P <br />OR OTHER APPROVED WATER ESISTIVE BARRIER MATERIAL SHALL BE CONTINUOUS <br />18 GA HEAD WALL FLASHING CONT SELF ADHERED TO THE TOP OF WALLS AND TERMINATED AT PENETRATIONS AND BUILDING <br />TO EXTEND MIN 8" BEYOND FLASHING TURN 3" UP ALL APPENDAGES IN A MANNER TO MEET THE REQUIREMENTS OF THE EXTERIOR WALL <br />UNDERLAYMENT ENVELOPE AS DESCRIBED IN SECTION R703.1. <br />AF SHINGLE PER SPECS <br />R703.7.3 WATER -RESISTIVE BARRIERS WATER -RESISTIVE BARRIERS SHALL BE <br />SHINGLE ROOF PER SPECS <br />STEP FLASHING TO INSTALLED AS REQUIRED IN SECTION R703.2 AND, WHERE APPLIED OVER WOOD -BASED <br />EXTEND MIN 8" BEYOND SHEATHING, SHALL INCLUDE A WATER -RESISTIVE VAPOR -PERMEABLE BARRIER WITH A <br />ROOF UNDERLAYMENT TO <br />UNDERLAYMENT PERFORMANCE AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. THE <br />TURN UP WALL MIN 8" <br />2� INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH THAT EACH LAYER <br />ROOF UNDERLAYMENT TO <br />ROOF SHEATHING PROVIDES A SEPARATE CONTINUOUS PLANE AND ANY FLASHING (INSTALLED IN <br />00 00 <br />PER PLAN TURN UP WALL MIN 8" ACCORDANCE WITH SECTION R703.4) INTENDED TO DRAIN TO THE WATER -RESISTIVE <br />BARRIER IS DIRECTED BETWEEN THE LAYERS. <br />PER PLAN EXCEPTION: WHERE THE WATER -RESISTIVE BARRIER THAT IS APPLIED OVER <br />z <br />WOOD -BASED SHEATHING HAS A WATER RESISTANCE EQUAL TO OR GREATER <br />ROOF SHEATHING <br />N1 THAN THAT OF 60-MINUTE GRADE D PAPER AND IS SEPARATED FROM THE STUCCO <br />BY AN INTERVENING SUBSTANTIALLY NON -WATER -ABSORBING LAYER OR <br />611 6" DESIGNED DRAINAGE SPACE. <br />R703.4 FLASHING. APPROVED METAL FLASHING, VINYL FLASHING, SELF -ADHERED z <br />MEMBRANES AND MECHANICALLY ATTACHED FLEXIBLE FLASHING SHALL BE APPLIED <br />SHINGLE -FASHION OR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. <br />METAL FLASHING SHALL BE CORROSION RESISTANT. FLUID -APPLIED MEMBRANES USED <br />RAKE WALL HEAD WALL RAKE WALL AS FLASHING SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S w <br />INSTRUCTIONS. ALL FLASHING SHALL BE APPLIED IN A MANNER TO PREVENT THE <br />ROOF TO WALL — SHINGLE TO SIDING ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE <br />WP12 to I WP13 BUILDING STRUCTURAL FRAMING COMPONENTS. <br />3 = 1 -011 SELF -ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH MMA 711. ALL <br />EXTERIOR FENESTRATION PRODUCTS SHALL BE SEALED AT THE JUNCTURE WITH THE <br />BUILDING WALL WITH A SEALANT COMPLYING WITH AAMA 800 OR ASTM C920 CLASS 25 <br />GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION, <br />TAPE EDGE OF HEAD <br />WALL FLASHING ASTMC1281, MMA 812, OR OTHER APPROVED STANDARD AS APPROPRIATE FOR THE <br />TYPE OF SEALANT. FLUID -APPLIED MEMBRANES USED AS FLASHING IN EXTERIOR <br />FIBER CEMENT SIDING WALLS SHALL COMPLY WITH AAMA 714. THE FLASHING SHALL EXTEND TO THE SURFACE <br />FIBER CEMENT SIDING <br />PER ELEVATIONS OF THE EXTERIOR WALL FINISH. APPROVED FLASHINGS SHALL BE INSTALLED AT THE <br />PER ELEVATIONS FOLLOWING LOCATIONS: <br />TAPE EDGE OF RAKE <br />WALL FLASHING 1. 1. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW <br />WALL SHEATHING PER PLAN <br />AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL <br />WALL SHEATHING PER PLAN <br />FINISH OR TO THE WATER -RESISTIVE BARRIER COMPLYING WITH SECTION 703.2 <br />FOR SUBSEQUENT DRAINAGE. MECHANICALLY ATTACHED FLEXIBLE FLASHINGS <br />SHINGLE WATER SHINGLE WATER <br />RESISTIVE BARRIER I SHALL COMPLY WITH MMA 712. FLASHING AT EXTERIOR WINDOW AND DOOR <br />RESISTIVE BARRIER <br />OVER FLASHING MIN 8" OVER FLASHING MIN 8" OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR MORE OF THE <br />FOLLOWING: <br />00 <br />STARTER STRIP <br />60 1.1 THE FENESTRATION MANUFACTURER'S INSTALLATION AND FLASHING <br />B0 STARTER STRIP <br />INSTRUCTIONS, OR FOR APPLICATIONS NOT ADDRESSED IN THE <br />RAKE WALL STEP FLASHING TO FENESTRATION MANUFACTURER'S INSTRUCTIONS, IN ACCORDANCE WITH <br />EXTEND MIN 8" BEYOND <br />THE FLASHING MANUFACTURER'S INSTRUCTIONS. WHERE FLASHING <br />HEAD WALL TRIM FLASHING <br />UNDERLAYMENT INSTRUCTIONS OR DETAILS ARE NOT PROVIDED, PLAN FLASHING SHALL BE <br />TO EXTEND MIN 8" BEYOND <br />UNDERLAYMENT FIELD BEND PANEL UP 1 112" INSTALLED AT THE SILL OF EXTERIOR WINDOW AND DOOR OPENINGS. PAN <br />DING <br />'KE <br />FLASHING SHALL BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT <br />WATER TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER <br />CONT SELF ADHERED CONT BUTYL TAPE SEALANT PER <br />RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. OPENINGS USING PAN <br />FLASHING TURN 3" UP WALL MANUFACTURER INSTALLATION <br />FLASHING SHALL INCORPORATE FLASHING OR PROTECTION AT THE HEAD <br />INSTRUCTIONS <br />CONT BUTYL TAPE SEALANT PER <br />AND SIDES. <br />MANUFACTURER INSTALLATION <br />'Z'CLOSURE <br />INSTRUCTIONS 00 1.2 IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A <br />00 00 REGISTERED DESIGN PROFESSIONAL. <br />STANDING SEAM METAL <br />'Z'CLOSURE <br />ROOF PER SPECS 1.3 IN ACCORDANCE WITH THE OTHER APPROVED METHODS. <br />STANDING SEAM METAL 1.4 IN ACCORDANCE WITH FMA/AAMA 100, FMA/AAMA 200, FMA/WDMA <br />ROOF UNDERLAYMEN'rTo <br />ROOF PER SPECS TURN UP WALL MIN 250, FMA/AAMA/WDMA 300 OR FMA/AAMAIWDMA 400. <br />2.2 AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY <br />CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH <br />ROOF UNDERLAYMENT TO 4*� <br />TURN UP WALL MIN 8" PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. <br />3.3 UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL <br />ROOF SHEATHING ROOF SHEATHING COPINGS AND SILLS. <br />PER PLAN PER PLAN____,� 4.4 CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. <br />5.5 WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A <br />CONT SELF ADHERED <br />FLASHING TURN 3" UP WALL---� WALL OR FLOOR ASSEMBLY OF WOOD -FRAME CONSTRUCTION. <br />6.6 AT WALL AND ROOF INTERSECTIONS. <br />RAKE WALL HEAD WALL RAKE WALL 7.7 AT BUILT-IN GUTTERS. <br />WP14 ROOF TO WALL STANDING SEAM ROOF TO SIDING WP15 THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />r I -1111= 1 —not FLASHING AND WATERPROOFING METHODS TO BE USED. <br />')_ \ Val <br />IV- <br />\t%r.. <br />tiss \ k' 111�0'0 <br />dy <br />eke - <br />CO <br />'e'j%e, <br />?k,a%ls . \Le's v <br />kol toqkva J�tlq(z <br />�31 <br />cn <br />0 <br />0 <br />Cou <br />3�: <br />ui <br />z <br />z <br />Q_ <br />CD <br />-C= <br />U) <br />cu <br />0 <br />L_ <br />CL <br />CL <br />0 <br />L_ <br />CL <br />cl) <br />C/) <br />cu <br />m <br />0 <br />SHEET NO. <br />WP 2,0 <br />