RESTAURANT INTERIOR BUILD -OUT FOR:
<br />JEREMIAH'S ITALIAN ICE
<br />7936 GALL BLVD ZEPHYRHILLS, FLORIDA 33541
<br />YOGI 108 FL, LLC
<br />JEREMIAH'S ITALIAN ICE
<br />7936 GALL BLVD
<br />ZEPHYRHILLS, EE 33541
<br />ARCHITECT0
<br />:
<br />SAMUEL OLMEDO, ARCHITECT
<br />P.O.BOX 784825
<br />WINTER GARDEN, FLORIDA 34787
<br />PHONE (407) 967- 3109
<br />EMAIL: soarcht@ yah oo. com
<br />CONTRACTOR NOTE:
<br />1. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR ,THE SUB -CONTRACTOR (S), AND THE
<br />TRADES WORKERS, TO REVIEW ALL PERMIT APPROVED DRAWINGS AND DOCUMENTS IN ORDER TO
<br />FAMILIAR IZE WITH THIS PROJECT'S SCOPE OF WORK ALONG WITH THE EXISTING FIELD CONDITIONS
<br />PRIOR TO START OF WORK.
<br />2. THE GEN ERALCON TRACTOR SHALL MAINTAIN ON SITE ONLY THE CITY OF ORLANDO STAMP AND ARCHITECT'S
<br />SIGNED AND SEALED PERMITTED CONSTRUCTION DOCUMENTS. NO OTHER COPIES OR PREVUIOUS VERSIONS
<br />WILL BE ON -SITE. ALSO, ALL PERMIT DOCUMENTS SHALL BE MAINTAINED CLEAN, ORDER AND UPDATED.
<br />3. IT IS RECOMMENDED THAT THE GENERAL CONTRACTOR ESTABLISH A PRE -CONSTRUCTION MEETING
<br />WITH THE ARCHITECT OF RECORD FOR THIS PROJECT IN ORDER TO REVIEW THE PERMIT DRAWINGS
<br />DOCUMENTS AND EXISTING FIELD CONDITIONS.
<br />4. THE GENERAL CONTRACTOR SHALL FIELD VARIFY FIELD CONDITIONS, UTILIES, WALLS, LOCATION (S)
<br />PROJECT COMPONENTS,AND EXISTING TENANT SPACE (S)' DIMENSIONS FOR PROPER VERIFICATION.
<br />IT IS RECOMMENDFD GENERAL CONTRACTOR CHAULK OUTIINF" ON (FLOOR) CONCRFTF SLAB THE
<br />SCOPE OF WORK : WALLS, EQUIPTMENT, PLUMBING LINES, AND ANY OTHER CONDTIONS AS REQUIRED
<br />TO CROSS-REFERENCE WITH THE FLOOR PLAN ALTERATIONS, LIFE -SAFETY PLAN, AND MECHANICAL,
<br />ELECTRICAL, PLUMBING, AND SPRINKLER PLANS TO IDENTIFY WORKABLE PROJECT CONDITIONS.
<br />5. ERRORS AND OMISSIONS:
<br />ANY AMBIGUITIES, ERRORS, OMISSISIONS, OF DRAWINGS, DEFICIENCIES, AMBIGUITIES SPECIFICATIONS, NOTES,
<br />DIMENSIONS, SYMBOLS, OR INCORECT DATA SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT
<br />IMMIDIATELY FOR CORRECTION, CLARIFICATION, AND OR REMEDIATION.
<br />6. ALL CORRESPONDENCE - REQUEST FOR INFORMATION (RFI) , TRANSMITTALS, SUBSTITUTIONS,
<br />CLARIFICATIONS, SCHEDULES, AND MEETINGS SHALL BE MADE ONLY BY THE GENERAL CONTRACTOR
<br />TO THE ARCHITECT VIA U.S. MAIL AND ELECTRONIC MAIL. TELEPHONE CALLS, CELL PHONE TEXT
<br />MESSAGES WILL NOT BE ACCEPTED FOR THESE PURPOSES. GENERAL TELEPHONE COMMUNICATIONS ARE ACCEPTED.
<br />PROJECT SITE LOCATION
<br />Ev P\�\NG
<br />OMpo �Gp
<br />�ORNFOR OQN�RNG`G
<br />Px�,
<br />GOOF\'SNOFZE\L\-S
<br />09O
<br />r '1A
<br />cX ALL WORK SHALL COMPLY WITH
<br />n,*` NFFA CODES AND STANDARDS
<br />REVIEW DATE I
<br />CITY OF ZEPHYRHI LUS_t_�
<br />FIRE AND LIFE SAFETY EXAMINERS_
<br />nMn ICr`T TCNI A NIT C 0A G`E
<br />CODE DATA
<br />APPLICABLE CODES
<br />FLORIDA BUILDING CODE 6TH EDITION , 2020 - BUILDING
<br />FLORIDA FIRE PREVENTION CODE - 2017 (6TH EDITION).
<br />OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION
<br />NATIONAL ELECTRIC CODE - 2014
<br />FLORIDA BUILDING CODE, 2020 - BUILDING
<br />* OCCUPANCY IYPLS:
<br />CHAPTER 3 : USE AND OCCUPANCY CLASSIFICATION
<br />SECTION 303.1.1 : SMALL BUILDING AND TENANT SPACES
<br />SECTION 303.1.2 SMALL ASSEMBLY SPACES. ASSEMBLY OCCUPANCY W/ OCCUPANCY LESS THAN 50 IS GROUP B.
<br />SECTION 304.1 : GROUP B-BUSINESS (FOOD ESTABLISHMENT WITH OCCUPANCY UNDER 50)
<br />* CONSTRUC IION TYPES:
<br />CHAPTER 5 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS
<br />TABLE 504.3 - ALLOWABLE BUILDING HEIGHT ABOVE GRADE PLANE
<br />OCCUPANCY - A2 / NS / TYPE II - B / 55 FT.
<br />TABLE 504.4 - ALLOWABLE STORIES ABOVE GRADE PLANE
<br />OCCUPANCY - A2 / NS / TYPE II - B / 2 STORIES
<br />TABLE 506.2 - ALLOWABLE AREA FACTOR
<br />OCCUPANCY - A2 / NS / TYPE II - B / 9,500 S.F.
<br />TABLE 508.4 - REQUIRED SEPERATION OF OCCUPANCY (HOURS)
<br />OCCUPANCY B
<br />B LEFT TENANT) N/R
<br />M RIGHT TENANT) 1
<br />CHAPTER 6: TYPE OF CONSTRUCTION
<br />TABLE 601: FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)
<br />BUILDING ELEMENT / TYPE II B
<br />PRIMARY STRUCTURAL FRAME - 0
<br />BEARING WALLS : EXTERIOR & INTERIOR - 0
<br />NON - BEARING WALLS AND PARITIONS: EXTERIOR & INTERIOR - 0
<br />FLOOR CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS 0
<br />ROOF CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS 0
<br />TABLE 602: FIRE -RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS
<br />BASED ON FIRE SEPARATION DISTANCE
<br />SEPERATION TYPE OF CONSTRUCTION
<br />OCCUPANCY
<br />DISTANCE (FT)
<br />IIB
<br />1 HR
<br />CHAPTER
<br />8: INTERIOR FINISHES
<br />SECTION
<br />803 WALL AND CEILING
<br />FINISHES
<br />TABLE 803.11 - INTERIOR WALL &
<br />CEILING FINISH REQUIREMENTS
<br />BY OCCUPANCY
<br />GROUP
<br />SPRINKLERED
<br />INTERIOR EXIT
<br />CORRIDORS
<br />ROOMS
<br />STAIRWAYS AND RAMPS
<br />ENCLOSURES
<br />AND
<br />AND EXIT PASSAGE WAYS STAIRWAYS AND
<br />RAMPS SPACES
<br />B
<br />A
<br />B
<br />C
<br />* EGRESS:
<br />CHAPTER 10: MEANS OF
<br />EGRESS
<br />TABLE 1004.1.2 - MAXIMUM
<br />FLOOR AREAS ALLOWANCES
<br />PER OCCUPANT
<br />FUNCTION OF SPACE
<br />OCCUPANT
<br />LOAD FACTOR
<br />ASSEMBLY W/ OUT FIXED SEATS
<br />UNCONCENTRATED (TABLES
<br />& CHAIRS)
<br />15
<br />STANDING SPACE
<br />05
<br />KITCHEN
<br />200
<br />SECTION 1005 - MEANS OF
<br />EGRESS SIZING
<br />SECTION 1005.3.2 - OTHER
<br />EGRESS COMPONENTS
<br />NUMBER OF EGRESS
<br />EGRESS
<br />OCCUPANTS REQUIRED
<br />PROVIDED
<br />39 X 0.2 7.8 INCHES 64 INCHES
<br />TABLE 1017. 2 - EXIT ACCESS TRAVEL DISTANCE:
<br />MAXIMUM DISTANCE OF TRAVEL - GROUP B WITH SPRINKLER - 250 FT.
<br />TABLE 1020.2 - MINIMUM CORRICOR WIDTH
<br />OCCUPANCY (ANY NOT LISTED) : 44 INCHES
<br />FLORIDA BUILDING CODE, 2017 - PLUMBING
<br />FPC TABLE 403.1 - PLUMBING FIXTURE REQUIREMENTS
<br />DESCRIPTION - BUSINESS: B
<br />FIXTURE REQUIRED PROVIDED
<br />WATER CLOSET MALE 1 /75 FEMALE 1 /50 02
<br />LAVATORIES (MALE / FEMALE) 1 / 200 02
<br />DRINKING FOUNTAINS 1 / 1000 (SEE 410.4 - SUB-STITUTION)
<br />UTILITY SINK 01 01
<br />FLORIDA FIRE PROVENTION CODE 2017 - 6TH EDITIION
<br />NFPA 101 - OCCUPANT LOAD SIGN SHALL BE POSTED STATING MAXIMUM OCCUPANCY FOR SPACE.
<br />EXTERIOR SIGNAGE NOTE:
<br />ANY AND ALL SIGNAGE DEPICTED WITHIN THESE DRAWING IS SCHEMATIC IN NATURE.
<br />ANY APPROVAL RECEIVED FOR PERMIT DOES NOT CONSTITUTE APPROVAL FOR THE
<br />CONSTRUCTION OF ANY SIGN / SIGN STRUCTURE COVERED WITHIN ORANGE COUNTY
<br />CODE SECTION 31.5. SIGNAGE MUST COMPLY WITH JURIDICTIONAL CODE, OR ANY
<br />APPLICABLE APPROVED SIGN PLAN. ALL PROPOSED SIGNAGE, INCLUDING SIGNAGE
<br />STRUCTURES, ARE REQUIRED TO SUBMIT A SEPARATE APPLICATION AND SHALL BE
<br />SUBMITTED THROUGH THE BUILDING PERMIT RESIDENTIAL PROCESS FOR REVIEW BY
<br />ZONING, BUILDING AND DEVELOPMENT ENGINEERING.
<br />DRAWINGS SYMBOLS
<br />[1201 ROOM NUMBER
<br />20 DOOR NUMBER
<br />20 WINDOW NUMBER
<br />DATUM ELEV.
<br />0-DEMOLITION NOTES
<br />W1 WALL TYPE
<br />N
<br />W IE1 INTERIOR ELEVATION NUMBER
<br />E
<br />AX SHEET NUMBER REFERENCE
<br />S
<br />NE EXTERIOR ELEVATION NUMBER
<br />AX
<br />SHEET NUMBER REFERENCE
<br />DETAIL NUMBER
<br />SHEET NUMBER REFERENCE
<br />WS1 WALL SECTION NUMBER
<br />AX SHEET NUMBER REFERENCE
<br />A BUILDING SECTION NUMBER
<br />�:
<br />AX SHEET NUMBER REFERENCE
<br />e___C�91_UMN GRID DESIGNATION
<br />-
<br />REVISION CLOUD AND SYMBOL DESIGNATION
<br />WALL TYPES
<br />EXISTING STUD WALLS
<br />- NEW METAL STUD WALL
<br />--- 1 HR. F.R. METAL STUD WALL
<br />---- 2 HR. F.R. METAL STUD WALL
<br />REINF. C.M.U. BLOCK WALL
<br />INDEX TO DRAWINGS. -
<br />ARCHITECTURAL
<br />T1.0 - COVER, LOCATION MAPS, CODE REVIEW, DRAWINGS INDEX
<br />A0.0 - EXISTING PLAN AND EXISTING REFLECTIVE CEILING- DEMOLITIONS
<br />A1.0 - LIFE SAFETY PLAN
<br />A2.0 - A.D.A FIGURES AND DIAGRAMS STANDARDS
<br />A3.0 - EQUIPMENT PLAN
<br />A4.0 - FLOOR PLAN
<br />A5.0 - WALL SECTIONS - NOT IN SCOPE OF WORK
<br />A6.0 - INTERIOR WALL FINISHES AND FLOOR FINISH PLAN
<br />A7.0 - EXISTING TOILET ROOM FINISH ALTERATION
<br />A8.0 - EXISTING INTERIOR ELEVATIONS
<br />A9.0 - EXISTING INTERIOR ELEVATIONS
<br />MECHANICAL
<br />NO WORK
<br />ELECTRICAL
<br />E1.0 - POWER PLAN
<br />E2.0 - PANEL SCHEDULE & RISER
<br />PLUMBING
<br />P1.0 - PLUMBING SANITARY PLAN & RISER
<br />P2.0 - PLUMBING WATER PLAN & RISER
<br />FIRE RATED DETAILS
<br />FR1.0 - FIRE RATED PENETRATIONS DETAILS
<br />FR2.0 - FIRE RATED ASSEMBLY DETAILS
<br />SAMUEL OLMEDO
<br />ARCHITECT
<br />FL. RFG. AR0015027
<br />TEL_ 407. 967. 3109
<br />soarcht @ yahoo.com
<br />P.O. BOX 784825
<br />WINTER GARDEN, FL. 34778
<br />PERMIT SET
<br />REVISIONS:
<br />NO DATE DESCRIPTION
<br />3-25-12 JII CORP
<br />INSTRUMENTS OF SERVICE OWNERSHIP
<br />ALL REPORTS, PLANS, SPECIFICATIONS,
<br />COMPUTER FILES, FIELD DATA, NOTES
<br />INSTRUMENTS PREPARED BY THE
<br />AND OTHER DOCUMENTS AND RELATED
<br />INSTRUMENTS PREPARED BY THE
<br />ARCHITECT OR CONSULTANTS AS
<br />INTRUMENTS OF SERVICE SHALL REMAIN
<br />THE PROPERTY OF THE ARCHITECT OR
<br />CONSULTANT. THE ARCHITECT AND OR
<br />THE CONSULTANT SHALL RETAIN ALL
<br />COMMON LAW, STATUTORY AND OTHER
<br />RESERVED RIGHTS, INCLUDING THE
<br />COPYRIGHT THERETO.
<br />RESTAURANT
<br />INTERIOR BUILD -OUT
<br />FOR:
<br />JEREMIAHIS
<br />TAE AN ICE
<br />7936 GALL BLVD
<br />ZEPHYRHILLS, FL 33541
<br />SHEET
<br />COVER
<br />Tl m0
<br />N,RIII
<br />6� VICINITY MAP
<br />(D
<br />WRTII
<br />SITE PLAN
<br />NO SCALE