EXISTING FLOOR PLAN <br />DIMENSIONS: <br />GENERAL CONTRACTOR TO FIELD VARIFY <br />LOCATION OF PROPOSED NEW WALLS <br />EQUIPMENT AND PLACEMENT, PRIOR <br />TO START OF WORK. DIMENSION DISCREPENCY <br />OR EQUIPMENT SHALL BE BROUGHT <br />TO ARCHITECT'S ATTENTION FOR CORRECTION. <br />SPRINKLER SYSTEM: <br />THE EXISTING SPRINKLER SYSTEM TO REMAIN, AND <br />REQUIRED CHANGES SHALL BE PROVIDED BY SPRINKLER <br />SUBCONTRACTOR FOR DESIGN ALTERATIONS DESIGN APPROVAL. <br />DESIGNALTERATIONS, SHOP DRAWING, AND CALULATIONS TO BE UNDER <br />A SEPARATE PERMIT . <br />A FL STATE LICENSED FIRE SPRINKLER CONTRACTOR SHALL APPLY FOR <br />AND OBTAIN A FIRE SPRINKLER PERMIT THROUGH <br />ANY WORK SHALL BEGIN. <br />4 <br />"I <br />It <br />ElliACT <br />HALL <br />; UAI <br />7�� <br />EXISTING 6 TON RTU <br />Q <br />EXISTING SPIRAL DUCT' <br />J <br />I <br />DINING <br />OPEN CEILING <br />9 <br />CLG Q CLG Q E CLG <br />EXISTING REFLECTIVE <br />CEILING PLAN <br />ACT <br />A <br />E3 <br />m <br />KITCHEN <br />YPBD. CEII <br />X <br />BUILDING DEMOLITION LEGEND <br />SYMBOL DESCRIPTION <br />LOWER PORTION OF WALL IS TO BE REMOVED. <br />01 UPPER PORTION OF WALL TO REMAIN MAKING A SOFFIT <br />BETWEEN OPEN CEILING AND ACT IN KITCHEN <br />02 WALL TO BE REMOVED <br />03 COUNTER TO BE REMOVED <br />04 REMOVE FLOORING. <br />CLEAN AND PREP FOR NEW FLOORING <br />05 REMOVE WALL FINISH. CLEAN AND PREP FOR NEW FINISH <br />REMOVE DRINKING FOUNTIAN <br />06 PLUG AND CAP. <br />07 REMOVE DOOR <br />pg REMOVE BENCH AND SOFFIT ABOVE <br />09 REMOVE HAND SINK <br />PLUG AND CAP. <br />10 AREA FOR NEW ACT FOR NEW MEN'S RESTROOM <br />0-- <br />AREA FOR NEW ACT FOR NEW WOMEN'S RESTROOM <br />0- <br />2 RELOCATE SINK TO MEET ADA REQUIREMENTS IF NEEDED. FIELD VERIFY <br />0- <br />3 REUSE EXISTING DOOR. FIELD VERIFY CONDITION <br />14 PREP AREA TILE TO REMAIN. CLEAN, REPAIR, AND INFILL AS NEEDED <br />MATCH EXISTING <br />ONTRACTOR NOTE: <br />HVAC DUCTWORK AND DIFFUSERS TO REMAIN -CLEAN AND REPAIR <br />ELECTRICAL LEGEND <br />NL OUTLET <br />18 ABOVE FIN. FLR. <br />&42" <br />42" A.F.F. WALL RECPI <br />HEIGHT AFF VARIFY - SEE PLANS <br />@CLG <br />CEILING MNT DUPLEX <br />&GFI <br />GRND FAULT INTERUPT <br />@0220V <br />18" A.F.F. 220V RECPj <br />EQUIPT. VARIES - SEE PLANS <br />FOUR PLEX <br />WALL OUTLET <br />I= FL <br />FLOOR RECPT <br />DIRECT CONNECTION <br />J <br />JUNCTION FOR LIGHTS <br />DISCONNECT <br />O <br />ELECTRICAL PANEL <br />HVAC LEGEND <br />A/C DIFFUSER <br />ro-� <br />CLG. VENT <br />A/C RETURN AIR <br />R <br />CLG. GRILL <br />® <br />EXHAUST FAN <br />H VAC NOTE: <br />ALL EXISTING HVAC SYSTEMS TO REMAIN, AS IS, UNLESS NOTED <br />OTHERWISE ON DEMOLITIONS PLANS, AND / OR ALTERATION PLANS. <br />FIRE PROTECTION <br />EXISTING <br />SPRINKLER HEAD <br />NEW OR RELOCATED <br />® <br />SPRINKLER HEAD <br />F.E. <br />EXISTING <br />>O <br />FIRE-EXTINGUISHER <br />ELECTRICAL LEGEND <br />SYMBOL <br />DESCRIPTION <br />EXISTING BULBS TO REPLACED WITH NEW LED <br />2'X4' LED LAY -IN W/ ACRYLIC LENSES <br />KITCHEN <br />LXIS-HNG �13ULBS 10 RLPLACED WITH NEW LED) <br />2'X4' LED LAY -IN W/ TROFFER LENSES <br />Al <br />PARABOLIC LED <br />CUSTOMER AREA RESTROOMS <br />EXISTING <br />C1® <br />CEILING MOUNTED RECESSED DOWNLIGHT <br />0 Q <br />EXISTING <br />El 0 <br />EMERGENCY LIGHT <br />EXISTING <br />00 <br />EMERGENCY LIGHT <br />E3 <br />& EXIT LIGHT COMBO <br />NEW <br />F o <br />CEILING MOUNTED RECESSED DOWNLIGHT <br />RL38/CTR1902 WHITE/A19 MAX 10OW LAMP <br />NEW TRACK AND FIXTURES <br />CTL2120/PAR 20 MAX 50W LAMPS <br />ADD TO NEW POWER CIRCUIT <br />GENERAL NOTES - <br />DIVISION 1 GENERAL REQUIREMENTS <br />1. THE INTENT OF THESE DOCUMENTS IS TO PROVIDE FOR THE CONSTRUCTION OF THIS <br />PROJECT, COMPLETE AND FUNCTIONAL IN ALL RESPECTS. THE CONTRACTOR SHALL BE <br />RESPONSIBLE FOR THIS RESULT. THE OMISSION OF EXPRESS REFERENCE TO WORK <br />NECESSARY AND REASONABLY INCIDENTAL FOR THE COMPLETE CONSTRUCTION OF THE <br />PROJECT SHALL NOT BE CONSTRUED AS RELEASING THE CONTRACTOR FROM HIS <br />RESPONSIBILITIES. <br />2. THE CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, CLEARANCES AND <br />CONDITIONS TO THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. FAILURE TO DO SO <br />CONSTITUTES ACCEPTANCE AND RESPONSIBILITY FOR ALL EXISTING CONDITIONS. THE <br />CONTRACTOR WILL NOT BE ALLOWED ADJUSTMENTS IN THE TIME OR MONEY REQUIRED TO <br />RECTIFY THE SITUATION. <br />3. DO NOT SCALE DRAWINGS. GIVEN DIMENSIONS SHALL GOVERN. LARGE SCALE DRAWINGS <br />SHALL GOVERN OVER SMALL SCALE DRAWINGS. <br />4. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF ALL PURCHASED, FABRICATED AND <br />FINISHED ITEMS FOR REVIEW BE THE ARCHITECT UNLESS WAIVED BY THE SAME. <br />5. ALL EQUIPMENT, MATERIALS AND ARTICLES INCORPORATED INTO THE PROJECT SHALL BE <br />NEW AND UNDAMAGED. ALL WORKMANSHIP SHALL BE WITHIN INDUSTRY STANDARDS. <br />6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR AND REPLACEMENT OF DAMAGE <br />TO AREAS CAUSED BY HIS WORK AT NO ADDITIONAL COST TO THE OWNER. <br />7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY CONDITIONS RELATING TO JOB <br />CONSTRUCTION INCLUDING A SAFE ENVIRONMENT FOR OCCUPANTS OF AREAS ADJACENT <br />TO THE WORK AREA. <br />8. THE CONTRACTOR SHALL PAY ALL FEES FOR PERMITS NECESSARY FOR PROPER <br />COMPLETION OF WORK, UNLESS NOTED OTHERWISE. <br />9. SHOULD THE CONTRACTOR OBSERVE ERRORS, DISCREPANCIES OR OMISSIONS IN THE <br />CONTRACT DOCUMENTS, HE SHALL PROMPTLY NOTIFY THE ARCHITECT REQUESTING <br />CLARIFICATION. THE CONTRACTOR SHALL NOT PROCEED WITH WORK AFFECTED BY SUCH <br />ERRORS, DISCREPANCIES OR OMISSIONS WITHOUT RECEIVING CLARIFICATIONS. <br />ADJUSTMENTS INVOLVING SUCH CONDITIONS MADE BY THE CONTRACTOR WITHOUT PRIOR <br />CLARIFICATION BY THE ARCHITECT, SHALL BE AT THE CONTRACTOR'S OWN RISK. <br />COMPLICATIONS ARISING FROM PROCEEDING WITHOUT CLARIFICATION SHALL BE <br />RESOLVED AT THE CONTRACTOR'S EXPENSE. <br />0. ALL WORK PERFORMED ON THIS PROJECT SHALL COMPLY WITH ALL APPLICABLE LOCAL, <br />STATE AND NATIONAL CODES, LAWS AND ORDINANCES. <br />1. ANYTHING IN THE CONTRACT DOCUMENTS NOT WITHSTANDING, THE CONTRACTOR <br />ACCEPTS THE RESPONSIBILITY OF CONSTRUCTING A WATERTIGHT, WEATHER TIGHT <br />PROJECT. <br />2. CONTRACTOR SHALL COORDINATE LOCATION OF ALL NEW ROOF MOUNTED EQUIPMENT <br />WITH OWNER PRIOR TO INSTALL. CENTER EQUIPMENT OVER BEAM OR COLUMN UNLESS <br />DIRECTED OTHERWISE BY OWNER. <br />3. CONTRACTOR SHALL PROVIDE 2x BLOCKING AT ALL WALL MOUNTED EQUIPMENT OR <br />ACCESSORIES. <br />4. ALL SIGNS, INCLUDING WINDOW SIGNS, TO BE SUBMITTED FOR REVIEW AND APPROVAL <br />UNDER SEPARATE PERMIT BY OWNER/CONTRACTOR. <br />5. ALL ANGLES AT 45' OR 90' UNLESS OTHERWISE NOTED. <br />DIVISION 2 DEMOLITION; HAZARDOUS MATERIALS <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION REQUIRED TO ALLOW <br />FOR ALL PROPOSED NEW WORK. <br />PATCH, REPAIR, REPLACE AND FINISH ANY FLOOR, WALL OR CEILING TO MATCH ADJACENT <br />1. AREAS WHERE DEMOLITION HAS BEEN REQUIRED. <br />PROVIDE PROPER SHORING AND DISCONNECTION OF ALL UTILITIES PRIOR TO DEMOLITION. <br />2• THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING THE SITE FREE OF DEBRIS. <br />THE CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER PRIOR TO START OF WORK, <br />3• THE REQUIREMENTS FOR CORING OF FLOOR SLAB FOR ALL REQUIRED WORK. <br />4• THE ARCHITECT AND ENGINEERS, AND CONSULTANTS SHALL HAVE NO RESPONSIBILITY <br />5_ FOR THE DISCOVERY, PRESENCE, HANDLING, REMOVAL OR DISPOSAL OF OR EXPOSURE OF <br />PERSONS TO HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT SITE, INCLUDING BUT <br />NOT LIMITED TO ASBESTOS PRODUCTS, POLYCHLORINATED BIPHENYL (PCB) OR OTHER <br />6• TOXIC SUBSTANCES. <br />COMPLY WITH APPLICABLE CODES AND/OR ORDIANCES CONCERNING DEMOLITION <br />OPERATIONS, REFUSE REMOVAL, AND DISPOSAL. <br />DIVISION 3 CONCRETE <br />8. CLEAN, GRIND AND FILL EXISTING CONCRETE TO ACCEPT VINYL TILE, CARPER, OR CERAMIC <br />TILE. <br />FLOORS TO RECEIVE TILE OR SHEET VINYL SHALL NOT VARY MORE THAN 1 /4" PER 10 FT. <br />IflIVISION 5 METALS <br />2 STEEL FRAMING: WITH EACH TYPE OF METAL FRAMING REQUIRED, PROVIDE <br />MANUFACTURER'S STANDARD STEEL RUNNER, BLOCKING, LINTELS, CLIP ANGLES, SHOES, <br />REINFORCEMENTS, FASTENERS AND ACCESSORIES AS RECOMMENDED BY THE <br />MANUFACTURER FOR THE APPLICATIONS INDICATED. <br />1 METAL STUDS: OPEN BOX SHAPED SECTIONS, 3-1/2 INCH x 25 GAGE MIN. (20 GAGE FOR <br />STUDS OVER 14'-0" IN HT. AND AT WALL AT WATER HEATER / MOP SINK ENCLOSURE). <br />DIVISION 7 THERMAL & MOISTURE PROTECTION <br />2. ALL INSULATING MATERIALS IN CONCEALED SPACES HAVE A FLAME SPREAD RATING OF <br />75 OR LESS AN A SMOKE DEVELOPED RATING OF 450 OR LESS PER ASTM E84. <br />DIVISION 8 DOORS & WINDOWS <br />1. ALL GLASS SUBJECT TO HUMAN IMPACT SHALL CONFORM TO THE STANDARD SET FORTH <br />IN THE LOCAL BUILDING CODE. <br />ALL EXITS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR <br />1. SPECIAL KNOWLEDGE. <br />MANUALLY OPERATED EDGE OR SURFACE -MOUNTED FLUSH BOLTS AND SURFACE BOLTS <br />2. OR ANY OTHER TYPE OF DEVICE THAT MAT BE USED TO CLOSE OR RESTRAIN THE DOOR <br />ARE PROHIBITED. WHERE EXIT DOORS ARE USED IN PAIRS AND APPROVED AUTOMATIC <br />FLUSH BOLTS ARE USED, THE DOOR LEAF HAVING THE AUTOMATIC FLUSH BOLTS SHALL <br />3-HAVE NO DOORKNOB OR SURFACE -MOUNTED HARDWARE. THE UNLATCHING OF ANY LEAF <br />SHALL NOT REQUIRE MORE THAN ONE OPERATION. <br />PANIC HARDWARE, WHERE INSTALLED, SHALL COMPLY WITH THE LOCAL BUILDING CODE. <br />THE ACTIVATING MEMBER SHALL BE MOUNTED AT 36 TO 44 INCHES ABOVE THE FINISH <br />FLOOR. THE UNLATCHING FORCE SHALL NOT EXCEED 15 POUNDS WHEN APPLIED IN THE <br />DIRECTION OF TRAVEL. <br />4DIVISION 9 FINISHES <br />1.INTERIOR FINISHES TO HAVE A MAXIMUM FLAME SPREAD RATING OF 200 AND MAXIMUM <br />SMOKE DEVELOPMENT RATING OF 450. <br />2. STUD PARTITIONS TO BE ANCHORED SO AS TO RESIST A LATERAL LOAD OF 5 PSF AS <br />FOLLOWS, BOTTOM PLATE: ANCHOR TO SUB FLOOR WITH 300# POWER DRIVEN PINS AT <br />48" O.C. ICBO #1639 <br />3. GYP BOARD WALLS TO BE TAPED, SANDED AND HAVE SMOOTH FINISH, UNLESS NOTED <br />OTHERWISE. <br />4. THE CONTRACTOR SHALL PROVIDE AND INSTALL CAULKING WHERE NOT SPECIFICALLY <br />PERFORMED BY OTHER TRADES. <br />5. CERAMIC TILE FLOORS SHALL NOT VARY MORE THAN 1 /4" PER 10 FEET. <br />DIVISION 10 SPECIALTIES <br />1. SUITE NUMBER OR ADDRESS TO BE POSTED ABOVE DOOR. <br />2. CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND INSTALLATION / <br />MODIFICATION OF THE FIRE SPRINKLER SYSTEM. CONTRACTOR SHALL SUBMIT DRAWING <br />TO GOVERNING AUTHORITY FOR REVIEW AND APPROVAL PRIOR TO COMMENCING WITH <br />WORK. <br />DIVISION 15 MECHANICAL <br />1. VERIFY EXISTING MECHANICAL EQUIPMENT (HVAC) IS IN FULL WORKING ORDER, REPLACE <br />FILTERS THROUGHOUT SYSTEM. <br />2. VERIFY FRESH AIR SETTING, HUMIDITY CONTROLS, BALANCE, ETC. ARE ADEQUATE FOR <br />PROPOSED USE. REPLACE AND/OR MODIFY SYSTEM AS REQUIRED FOR COMPLIANCE WITH <br />LOCAL GOVERNMENTAL AGENCIES REQUIREMENTS. <br />SAMUEL OLMEDO <br />ARCHITECT <br />FL. REG. AR0015027 <br />TEL. 407. 967. 3109 <br />soarcht @ yahoo.com <br />P.O. BOX 784825 <br />WINTER GARDEN, FL. 34778 <br />W <br />_1 <br />LL <br />\ o <br />0 <br />W <br />PERMIT SET <br />REVISIONS: <br />NO DATE DESCRIPTION <br />3-25-12 JII CORP <br />INSTRUMENTS OF SERVICE OWNERSHIP <br />ALL REPORTS, PLANS, SPECIFICATIONS, <br />COMPUTER FILES, FIELD DATA, NOTES <br />INSTRUMENTS PREPARED BY THE <br />AND OTHER DOCUMENTS AND RELATED <br />INSTRUMENTS PREPARED BY THE <br />ARCHITECT OR CONSULTANTS AS <br />INTRUMENTS OF SERVICE SHALL REMAIN <br />THE PROPERTY OF THE ARCHITECT OR <br />CONSULTANT. THE ARCHITECT AND OR <br />THE CONSULTANT SHALL RETAIN ALL <br />COMMON LAW, STATUTORY AND OTHER <br />RESERVED RIGHTS, INCLUDING THE <br />COPYRIGHT THERETO. <br />RESTAURANT <br />INTERIOR BUILD -OUT <br />FOR: <br />JEREMIAH'S <br />TALIAN ICE <br />7936 GALL BLVD <br />ZEPHYRHILLS, FL 33541 <br />SHEET <br />EXISTING FLOOR PLAN AND <br />EXISTING REFLECTIVE <br />CEILING PLAN <br />AOO 00 <br />J <br />W <br />D <br />Q <br />