I " ' 11,,II111 11_r <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />FF w P WEATHERPROOF DUPLEX OUTLET <br />G.GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />F.I. <br />HALF -SWITCHED DUPLEX OUTLET <br />f. SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 THREE-WAY SWITCH <br />� 4 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />P.C. LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />Awo EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />PB PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />© TELEVISION (OPTIONAL) <br />© 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />�]M ELECTRIC METER <br />ELECTRIC PANEL <br />i DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />� J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J OPT. CEILING FAN <br />W (1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />3" VTR AIL <br />AIL <br />I I <br />I I <br />I I <br />I I <br />I OPT. <br />LAV LAV <br />HANSON I <br />BOX I <br />I I 3„ <br />I I W/C <br />LAV -T <br />3" SHOWER <br />TUB/ <br />W/C SHOWER \ <br />2n <br />STUDOR F� <br />Q Y DEL SINK <br />VENT <br />LL WI DISP. <br />LAV I W/C z" <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS <br />Unit -A- (1532) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1533 S.F. <br />4599 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10599 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33659 <br />1st 10 KW at 100% <br />10000 <br />BALANCE OF WATTS AT 40% <br />9464 <br />AIR CONDITIONER WATTS AT 100% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 <br />5200 <br />TOTAL: 31768 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Optional Overhead Service 200A <br />Same As Underground Indoor Panel <br />150 Or 200 Amp Service Center <br />NEMA1 <br />200 AMP <br />TER MA N <br />1 0-200 A P ,,rSerial Cable <br />NEMA <br />3R <br />Power Co. Feed #4 Solid COPPER Ground <br />Intersystem Bonding <br />Termination Per <br />NEC 08, 250.94 5/8" Galvanized Driven Ground <br />Rods at least 6' apart <br />typical 150-200 Amp Electrical Riser Diagram <br />TOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />HE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />C.O. <br />O <br />------------------------- <br />OUTDOOR LIVING <br />INSTALL LIGHT �\���� <br />ROUGH -IN <br />FOR OPT. <�jr\ > <br />FAN/LIGHT WP <br />GFI <br />DINING �\ <br />I <br />KITCHEN 1 <br />GFI <br />SWITCH FOR <br />DISPOSAL IN CAB <br />UNDER SINK <br />GREAT ROOM <br />/,>ROUGH -IN\ <br />FOR OPT. <br />FAN/LIGHT 1 <br />I I <br />1 / <br />FOYER I�,-- <br />' P <br />—E <br />I I <br />I <br />DB <br />ENtRY WID0- <br />LIGHT AS 0 GFI& <br />PER SPECS <br />DB&GFI TO - <br />BE ALIGNED <br />VERTICALLY / <br />I <br />I <br />I <br />I <br />I <br />GEL-j <br />C.M <br />1 UPSTAIRS t <br />!3�F%Ixj <br />GFI <br />@ 44" <br />\ <br />w.H. <br />A.F.F. <br />' \ 0 <br />I <br />GARAGE <br />I I <br />GARAGE <br />LIGHT AS <br />TER SPECS <br />GARAGE <br />O <br />DOOR <br />GFI <br />--------------- <br />I <br />I J <br />I <br />I <br />I�uj <br />Z <br />I <br />I� Q <br />IQ d <br />I <br />I <br />IQ Q <br />I <br />I-j V <br />I <br />I I>- <br />ILL U <br />I <br />I <br />IW <br />I <br />J <br />I> LU <br />I <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />DISCONNECT <br />1ST ELECTRICAL — UNIT —A 1532 <br />SCALE: Y4'=V-0" <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE <br />RANGE HOOD PER <br />SPECS <br />F— <br />OWNER'S <br />BEDROOM <br />/,>ROUGH -IN <br />f FOR OPT. <br />XV /fi>FAN/LIGHT <br />\ \ I <br />S.D. <br />O. BATH <br />WIP. <br />BATH 2 <br />r.7 <br />WIC <br />I <br />I <br />I <br />I <br />L <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />-----------t <br />I <br />W/P <br />-WIC <br />----------- <br />Al <br />\ I ` <br />I <br />�\ LOFTI'J <br />C.M \ <br />S.D � <br />I <br />I 1 <br />/,>ROUGH -IN <br />'Vfi FOR OPT. <br />< \�> <br />FAN/LIGHT <br />\BEDROOM 2 <br />2ND ELECTRICAL —UNIT—A 1532 <br />SCALE: Y4'=1'-0" <br />N <br />co <br />r <br />� <br />0 <br />� W <br />O <br />a C— o <br />cc o <br />N _0 N t <br />N d G <br />3 of <br />� � C <br />z : cc <br />3 '- <br />� c � <br />c E <br />� o <br />a o <br />CV <br />CV <br />0 <br />CV <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />CD E <br />O N 8 <br />C <br />0 <br />.3 N <br />Co( <br />u_� <br />2i <br />LdYNJumLL LL <br />13 <br />(L <br />Co <br />o <br />.N� IXJ <br />Z <br />IL W <br />mt <br />Z ¢ <br />M - <br />N J <br />O <br />ZO <br />U U <br />W <br />❑ ❑ <br />V M � <br />Z N O <br />o 0 <br />Z oa0o N <br />in MEE <br />Q o Q <br />Q <br />r <br />N <br />q) <br />V O <br />4 <br />O <br />V) <br />o) <br />we <br />U � <br />� d <br />Uo °y <br />c U) � <br />Q Y <br />e <br />�Q <br />N Of <br />o <br />M <br />J <br />,w <br />o 3 <br />'Z <br />a <br />E <br />LL- <br />� o <br />V <br />po <br />� � <br />Z® <br />o a <br />U <br />W0aa <br />ZO <br />oO <br />aw <br />aC <br />N� <br />o <br />Q <br />wz <br />n3 <br />Z <br />.Q <br />D 0 <br />OZ <br />Z <br />Cn v <br />V <br />�m <br />aw <br />J <br />< <br />z <br />op <br />Z <br />s° <br />wLL <br />W <br />U <br />a <br />Jw <br />o <br />w <br />pO <br />a <br />oQ <br />�� <br />0 <br />o T <br />>cc <br />m <br />N <br />co <br />E <br />c6 <br />r <br />IT— <br />MII+ <br />nc <br />Y <br />0 <br />00 <br />= m <br />�O <br />ono <br />E <br />r*1 <br />N <br />CN <br />O <br />N <br />dTT7 <br />CD <br />T <br />V! <br />< <br />r <br />00 <br />00 <br />O�0 <br />E <br />E O <br />o <br />Z <br />C <br />z <br />E O <br />JOB <br />NO: 22-09500-09493 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />13 <br />