My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38222 Fallstone Wy
Zephyrhills
>
Building Department
>
Building Plans
>
38222 Fallstone Wy
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 6:12:13 PM
Creation date
2/19/2025 8:17:53 AM
Metadata
Fields
Template:
Building Plans
Street #
38222
Location
Fallstone Wy
Contractor
Lennar Homes, LLC
Building Plans - Permit #
4901
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I-® <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />j4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />PH] <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />DB <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />PM <br />ELECTRIC METER <br />_lO <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />C� J <br />ROUGH -IN FOR OPT. CEILING FAN <br />��� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G r J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />AIL <br />I <br />I <br />I <br />f <br />jI HANSON <br />BOX <br />I I <br />lI wic <br />LAvam, <br />_j I 3" SHOWER <br />3" VTR <br />AIL <br />I <br />I <br />I <br />I <br />I <br />I OPT. <br />LAV <br />LAV <br />I <br />I <br />ti TUB/ <br />W/C SHOWER <br />2n <br />STUDOR FAR. <br />VENTq DBL SINK <br />L W/ DISP. <br />LAV I W/C <br />3" <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS <br />Unit -B- (1516) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1505 S.F. <br />4515 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10515 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33575 <br />1st 10 KW at 100% <br />10000 <br />BALANCE OF WATTS AT 40% <br />9430 <br />AIR CONDITIONER WATTS AT 100% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 1 <br />5200 <br />TOTAL: 31734 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Optional Overhead Service <br />Same As Underground <br />150 Or 200 Amp Service <br />I <br />Power Co. Feed <br />200A <br />Indoor Panel <br />Center <br />NEMA 1 <br />RMAN <br />200 AMP <br />NEMA <br />3R <br />Cable <br />#4 Solid COPPER Ground <br />Intersystem Bonding -7 <br />Termination Per <br />NEC 08, 250.94 5/8" Galvanized Driven Ground <br />Rods at least 6' apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />C.O. <br />DISCONNECT <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE <br />RANGE HOOD PER <br />SPECS <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />DB & GFI TO <br />BE ALIGNED <br />VERTICALLY <br />1ST ELECTRICAL - UNIT-B 1516 <br />SCALE: 4"=1'-0" <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />'JiRTAL REVIEW ASSIST <br />Virt l \P! As. Sfst, Inc. <br />— Flaps 3Or ,pleted and a §v't <br />for cor :Diir c� �l h the 2020 " -7th <br />Edition by Debra 4,I ne P)'22300 <br />,��aF <br />2ND ELECTRICAL - UNIT-B 1516 <br />SCALE: Y4'=1'-0" <br />N <br />fV <br />0 <br />cV <br />r, <br />0 <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building <br />Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural <br />engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />rn <br />W <br />Q <br />E <br />N <br />N <br />w <br />U <br />N <br />N <br />o <br />N a m <br />O <br />_ <br />H <br />N <br />Q <br />N n <br />M V <br />C J LL <br />LL <br />Q w <br />LL O W <br />E d <br />J _ <br />Z <br />r rn <br />o 0 U <br />_� <br />7 Eu N <br />p Z <br />m <br />Z <br />ILILW <br />U) c' <br />N N Z <br />m w <br />Q OO J <br />a <br />OU <br />v 5 v <br />W <br />❑❑❑ <br />U <br />N M <br />o g <br />z <br />o Q <br />r` <br />N <br />M <br />Z � <br />r6 <br />r <br />U <br />O <br />V) <br />N <br />L) o <br />N <br />U) <br />f6 <br />r- <br />U c <br />w <br />f - E <br />L dj <br />III I <br />V 0 � <br />Q N O> <br />C:,w <br />CO <br />Cl) <br />z3 <br />z <br />a <br />1_ <br />Q E <br />E o <br />o5 <br />oo <br />wZ <br />Zo <br />Q@ <br />Z© <br />Oj <br />I u (O <br />o E <br />o <br />X <br />&< <br />�o <br />< <br />OU <br />S< <br />aZ <br />�ao <br />�w <br />Y <br />'0 <br />0, <br />z <br />� J <br />�OZ <br />Cl) <br />a <br />cm <br />Z <br />�° <br />a <br />U <br />< M. <br />_ <br />oz <br />3 3o <br />wa <br />za <br />c <br />r <br />Z <br />C <br />E <br />CN <br />co <br />L <br />O <br />CV-3 <br />L6 <br />Lr> <br />o <br />II n <br />T <br />C m <br />O <br />EN <br />CO <br />C0 <br />N <br />CD <br />C_ <br />O <br />^ <br />d7 <br />d. <br />L-) <br />L n <br />T <br />a) <br />p <br />Z <br />_ <br />E O <br />y <br />�, <br />N <br />@ <br />n <br />E <br />U -1 <br />a ai <br />Q p <br />JOB <br />NO: 22-03339-03346 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />14 <br />
The URL can be used to link to this page
Your browser does not support the video tag.