Laserfiche WebLink
TAPE EDGE OF HEAD <br />WALL FLASHING <br />STUCCO ON FRAME - 7/8" <br />3-COAT SAND FINISH STUCCO <br />ON SELF FURRING LATH ON 2- <br />LAYERS OF WATER RESISTIVE <br />BARRIER COMPLYING WITH <br />ASTM E2556, TYPE 1 (TYP)— <br />WALL SHEATHING PER PLAN — <br />SHINGLE WATER <br />RESISTIVE BARRIER <br />OVER WEEP SCREED----- <br />WEEP SCREED— -_ <br />CONT SELF ADHERED <br />FLASHING TURN 3" UP WALL- <br />18 GA HEAD WALL FLASHING <br />TO EXTEND MIN 8" BEYOND <br />UNDERLAYMENT <br />SHINGLE ROOF PER SPECS — <br />ROOF UNDERLAYMENT TO <br />TURN UP WALL MIN 8" <br />ROOF SHEATHING <br />PER PLAN <br />NOTE: <br />ALL LATH AND LATH <br />ATTACHMENTS TO BE OUT OF <br />CORROSION -RESISTANT MATERIAL <br />3"=1'-0" <br />TAPE EDGE OF HEAD <br />WALL FLASHING <br />STUCCO ON FRAME - 7!8" 3-COAT SAND <br />FINISH STUCCO ON SELF FURRING LATH ON <br />2- LAYERS OF WATER RESISTIVE BARRIER <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP <br />WALL SHEATHING PER PLAN <br />SHINGLE WATER RESISTIVE <br />BARRIER OVER WEEP SCREED ---- <br />WEEP SCREED <br />HEAD WALL TRIM FLASHING TO <br />EXTEND MIN 8" BEYOND <br />UNDERLAYMENT <br />CONT SELF ADHERED <br />FLASHING TURN 3" UP WALL— <br />CONT BUTYL TAPE SEALANT PER <br />MANUFACTURER INSTALLATION <br />INSTRUCTIONS <br />'Z' CLOSURE <br />STANDING SEAM METAL <br />ROOF PER SPECS <br />ROOF UNDERLAYMENT TO <br />TURN UP WALL MIN 8" <br />ROOF SHEATHING <br />PER PLAN <br />3"= 1'-0" <br />R <br />z <br />00 <br />HEAD WALL <br />R <br />211_10I11111111111M <br />STUCCO ON FRAME - 7/8" 3-COAT SAND <br />FINISH STUCCO ON SELF FURRING LATH ON <br />2- LAYERS OF WATER RESISTIVE BARRIER <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP <br />WALL SHEATHING PER PLAN <br />SHINGLE WATER <br />RESISTIVE BARRIER <br />OVER WEEP SCREED <br />TAPE EDGE OF COUNTER <br />FLASHING <br />WEEP SCREED <br />COUNTER FLAS73"UP <br />CONT SELF AD <br />FLASHING TURN WALL <br />SHINGLE PER SPECS <br />STEP FLASHING TO <br />EXTEND MIN 8" BEYOND <br />UNDERLAYMENT <br />ROOF UNDERLAYMENT TO <br />TURN UP WALL MIN 8" <br />ROOF SHEATHING <br />PER PLAN <br />NOTE: <br />ALL LATH AND LATH <br />ATTACHMENTS TO BE OUT OF <br />CORROSION -RESISTANT MATERIAL <br />STUCCO ON FRAME - 7/8" 3-COAT SAND <br />FINISH STUCCO ON SELF FURRING LATH ON <br />2- LAYERS OF WATER RESISTIVE BARRIER <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP; <br />TAPE EDGE OF RAKE <br />WALL FLASHING <br />WALL SHEATHING PER PLAN <br />SHINGLE WATER RESISTIVE <br />BARRIER OVER WEEP SCREED <br />LVITAIAMIGIN :I. <br />RAKE WALL STEP FLASHING TO <br />EXTEND MIN 8" BEYOND <br />UNDERLAYMENT <br />FIELD BEND PANEL UP 1 1/2" <br />CONT BUTYL TAPE SEALANT 7PER <br />MANUFACTURER INSTALLATION <br />INSTRUCTIONS <br />'Z' CLOSURE \ <br />STANDING SEAM METAL <br />ROOF PER SPECS <br />ROOF UNDERLAYMENT TO \ <br />TURN UP WALL MIN <br />J-- ROOF SHEATHING <br />NOTE: PER PLAN <br />ALL LATH AND LATH <br />ATTACHMENTS TO BE CONT SELF ADHERED <br />OUT OF CORROSION FLASHING TURN 3" UP WALL <br />-RESISTANT MATERIAL <br />HEAD WALL <br />I2 <br />in <br />u <br />TAPE EDGE OF HEAD <br />WALL FLASHING <br />FIBER CEMENT SIDING <br />PER ELEVATIONS <br />AV WALL SHEATHING PER PLAN - <br />SHINGLE WATER <br />RESISTIVE BARRIER <br />OVER FLASHING <br />STARTER STRIP-----_ <br />00 <br />CONT SELF ADHERED <br />FLASHING TURN 3" UP WALL- <br />18 GA HEAD WALL FLASHING <br />TO EXTEND MIN 8" BEYOND <br />UNDERLAYMENT <br />SHINGLE ROOF PER SPECS - <br />ROOF UNDERLAYMENT TO <br />z TURN UP WALL MIN 8" <br />— <br />2 <br />- ROOF SHEATHING <br />00 <br />PER PLAN <br />RAKE WALL <br />WP12 - ROOF <br />3 -1 -0 , <br />TAPE EDGE OF HEAD <br />_ WALL FLASHING <br />R <br />RAKE WALL <br />WP14 <br />FIBER CEMENT SIDING <br />PER ELEVATIONS <br />WALL SHEATHING PER P <br />SHINGLE WATER <br />RESISTIVE BARRIER <br />OVER FLASHING MIN <br />STARTER STRI <br />HEAD WALL TRIM FLASHING <br />TO EXTEND MIN 8" BEYOND <br />UNDERLAYMENT <br />CONT SELF ADHERED <br />FLASHING TURN 3" UP WALLS <br />CONT BUTYL TAPE SEALANT PER <br />MANUFACTURER INSTALLATION <br />INSTRUCTIONS <br />'Z' CLOSURE <br />STANDING SEAM METAL <br />ROOF PER SPECS <br />ROOF UNDERLAYMENT TO <br />TURN UP WALL MIN 8" <br />ROOF SHEATHING <br />PER PLAN <br />311=1'-01' <br />FLASHING REQUIREMENTS (D <br />R730.1 GENERAL. EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A O <br />WEATHER -RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR WALL ENVELOPE <br />Cn <br />SHALL INCLUDE FLASHING AS DESCRIBED IN SECTION R703.4. U <br />O O -*- <br />R703A .1 WATER RESISTANCE. THE EXTERIOR WALL ENVELOPE SHALL BE DIMENSIONED L- <br />FIBER CEMENT SIDING AND CONSTRUCTED IN A MANNER THAT PREVENTS THE ACCUMULATION OF WATER (D 0-O <br />PER ELEVATIONS WITHIN THE WALL ASSEMBLY BY PROVIDING A WATER-RESISTANT BARRIER BEHIND THE co - <br />WALL SHEATHING PER PLAN EXTERIOR CLADDING AS REQUIRED BY SECTION R703.2 AND A MEANS OF DRAINING TO � U U <br />THE EXTERIOR WATER THAT PENETRATES THE EXTERIOR CLADDING. =3 cz Cu U) <br />SHINGLE WATER N -0 U <br />00 RESISTIVE BARRIER R703.2 WATER RESISTIVE BARRIER. ONE LAYER OF NO.15 ASPHALT FELT, FREE FROM C LO O <br />OVER FLASHING HOLES, COMPLY WITH ASTM D226 FOR TYPE 1 FELT OR OTHER APPROVED O 0 C O <br />WATER -RESISTIVE BARRIER SHALL BE APPLIED OVER STUDS OR SHEATHING OF ALL C C O V- <br />TAPE EDGE OF COUNTER EXTERIOR WALLS NO. 15 ASPHALT FELT SHALL BE APPLIED HORIZONTALLY, WITH THE co O `*CU <br />- <br />FLASHING UPPER LAYER LAPPED OVER THE LOWER LAYER NOT LESS THAN 2 INCHES. WHERE .� -0 E O O <br />00 JOINTS OCCUR, FELT SHALL BE LAPPED NOT LESS THAN 6 INCHES. OTHER APPROVED U) O L C)- <br />STARTER STRIP MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE WATER -RESISTIVE cuu) 4O Q <br />COUNTER FLASHING BARRIER MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE NO.15 ASPHALT FELT I— —0 U) Q <br />OR OTHER APPROVED WATER -RESISTIVE BARRIER MATERIAL SHALL BE CONTINUOUS <br />CONT SELF ADHERED TO THE TOP OF WALLS AND TERMINATED AT PENETRATIONS AND BUILDING <br />FLASHING TURN 3" UP WALL APPENDAGES IN A MANNER TO MEET THE REQUIREMENTS OF THE EXTERIOR WALL <br />ENVELOPE AS DESCRIBED IN SECTION R703.1. <br />z SHINGLE PER SPECS <br />R703.7.3 WATER -RESISTIVE BARRIERS WATER -RESISTIVE BARRIERS SHALL BE <br />0o STEP FLASHING TO INSTALLED AS REQUIRED IN SECTION R703.2 AND, WHERE APPLIED OVER WOOD -BASED <br />d EXTEND MIN 8" BEYOND SHEATHING, SHALL INCLUDE A WATER -RESISTIVE VAPOR -PERMEABLE BARRIER WITH A <br />UNDERLAYMENT PERFORMANCE AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. THE <br />z INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH THAT EACH LAYER <br />ROOF UNDERLAYMENT TO PROVIDES A SEPARATE CONTINUOUS PLANE AND ANY FLASHING (INSTALLED IN <br />TURN UP WALL MIN 8" 14 00 ACCORDANCE WITH SECTION R703.4) INTENDED TO DRAIN TO THE WATER -RESISTIVE <br />BARRIER IS DIRECTED BETWEEN THE LAYERS. <br />ROOF SHEATHING <br />PER PLAN CO EXCEPTION: WHERE THE WATER -RESISTIVE BARRIER THAT IS APPLIED OVER <br />6„ WOOD -BASED SHEATHING HAS A WATER RESISTANCE EQUAL TO OR GREATER <br />THAN THAT OF 60-MINUTE GRADE D PAPER AND IS SEPARATED FROM THE STUCCO <br />BY AN INTERVENING SUBSTANTIALLY NON -WATER -ABSORBING LAYER OR <br />6" DESIGNED DRAINAGE SPACE. <br />R703.4 FLASHING. APPROVED METAL FLASHING, VINYL FLASHING, SELF -ADHERED <br />MEMBRANES AND MECHANICALLY ATTACHED FLEXIBLE FLASHING SHALL BE APPLIED <br />SHINGLE -FASHION OR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. <br />METAL FLASHING SHALL BE CORROSION RESISTANT. FLUID -APPLIED MEMBRANES USED <br />AS FLASHING SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S <br />HEAD WALL RAKE WALL INSTRUCTIONS. ALL FLASHING SHALL BE APPLIED IN A MANNER TO PREVENT THE <br />- SHINGLE TO SIDING ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE <br />W P 13 BUILDING STRUCTURAL FRAMING SELF -ADHERED MEMBRANES USEDASFLASHING SHALL COMPLY WITH MMA 711. ALL <br />EXTERIOR FENESTRATION PRODUCTS SHALL BE SEALED AT THE JUNCTURE WITH THE <br />BUILDING WALL WITH A SEALANT COMPLYING WITH AAMA 800 OR ASTM C920 CLASS 25 <br />GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION, <br />ASTMC1281, MMA 812, OR OTHER APPROVED STANDARD AS APPROPRIATE FOR THE <br />TYPE OF SEALANT. FLUID -APPLIED MEMBRANES USED AS FLASHING IN EXTERIOR <br />FIBER CEMENT SIDING WALLS SHALL COMPLY WITH AAMA 714. THE FLASHING SHALL EXTEND TO THE SURFACE <br />PER ELEVATIONS OF THE EXTERIOR WALL FINISH. APPROVED FLASHINGS SHALL BE INSTALLED AT THE <br />FOLLOWING LOCATIONS: <br />TAPE EDGE OF RAKE <br />WALL FLASHING 1. 1. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW <br />WALL SHEATHING PER PLAN AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL <br />FINISH OR TO THE WATER -RESISTIVE BARRIER COMPLYING WITH SECTION 703.2 <br />SHINGLE WATER FOR SUBSEQUENT DRAINAGE. MECHANICALLY ATTACHED FLEXIBLE FLASHINGS <br />RESISTIVE BARRIER SHALL COMPLY WITH MMA 712. FLASHING AT EXTERIOR WINDOW AND DOOR <br />OVER FLASHING MIN 8" OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR MORE OF THE <br />FOLLOWING: <br />00 STARTER STRIP 00 1.1 THE FENESTRATION MANUFACTURER'S INSTALLATION AND FLASHING <br />RAKE WALL STEP FLASHING TO INSTRUCTIONS, OR FOR APPLICATIONS NOT ADDRESSED IN THE <br />EXTEND MIN 8" BEYOND FENESTRATION MANUFACTURER'S INSTRUCTIONS, IN ACCORDANCE WITH <br />UNDERLAYMENT THE FLASHING MANUFACTURER'S INSTRUCTIONS. WHERE FLASHING <br />INSTRUCTIONS OR DETAILS ARE NOT PROVIDED, PLAN FLASHING SHALL BE <br />FIELD BEND PANEL UP 1 1/2" INSTALLED AT THE SILL OF EXTERIOR WINDOW AND DOOR OPENINGS. PAN <br />FLASHING SHALL BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT <br />CONT BUTYL TAPE SEALANT PER WATER TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER <br />MANUFACTURER INSTALLATION RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. OPENINGS USING PAN <br />INSTRUCTIONS FLASHING SHALL INCORPORATE FLASHING OR PROTECTION AT THE HEAD <br />AND SIDES. <br />00 <br />Z' CLOSURE 1.2 IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A <br />STANDING SEAM METAL o0 REGISTERED DESIGN PROFESSIONAL. <br />ROOF PER SPECS 1.3 IN ACCORDANCE WITH THE OTHER APPROVED METHODS. <br />1.4 IN ACCORDANCE WITH FMA/AAMA 100, FMA/AAMA 200, FMA/WDMA <br />ROOF UNDERLAYMENT TO 250, FMA/AAMA/WDMA 300 OR FMA/AAMA/WDMA 400. <br />TURN UP WALL MIN 8" 2.2 AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY <br />CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH <br />PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. <br />3.3 UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL <br />ROOF SHEATHING COPINGS AND SILLS. <br />PER PLAN__,, <br />LAN 4.4 CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. <br />5.5 WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A <br />CONT SELF ADHERED WALL OR FLOOR ASSEMBLY OF WOOD -FRAME CONSTRUCTION. <br />FLASHING TURN 3" UP WALL 6.6 AT WALL AND ROOF INTERSECTIONS. <br />HEAD WALL RAKE WALL 7.7 AT BUILT-IN GUTTERS. <br />f <br />- STANDING SEAM ROOF TO SIDING THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />WP 15 FLASHING AND WATERPROOFING METHODS TO BE USED. <br />Cif.. <br />aD <br />a� <br />0 � <br />to <br />MAY 0 Z 2023 <br />O <br />Virtual Review Assist, Inc. <br />r 0 <br />Plans Review completed and approved U <br />Ofor compliance with the 2020 F6C 7th Edition <br />by Debra Anne Klahr PX2300 <br />L- <br />cn <br />co <br />Q <br />z <br />z <br />J <br />d <br />SHEET NO. <br />WP 2,0 <br />