Laserfiche WebLink
a <br />STUCCO ON FRAME — 7/8" 3—GOAT SAND <br />FINISH STUCCO ON SELF FURRING LATH ON <br />2— LAYERS OF WATER RESISTIVE BARRIER <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP' <br />WALL SHEATHING PER PLAN <br />SHINGLE WATER RESISTIVE <br />BARRIER OVER WEEP SCREED------_,. <br />WEEP SCREED <br />HOLD 1/4" AIR GAP <br />BETWEEN WEEP <br />SCREED AND FLASHING <br />COUNTER FLASHING <br />CONT SELF ADHERED FLASHING TO <br />LAP FLASHING AND TURN 3" UP WALL <br />FLASHING <br />PT 1X10 BLOCKING <br />CONT SELF ADHERED FLASHING <br />TURN 3" UP BLOCKING <br />CEMENT MORTAR <br />TILE ROOF PER SPECS <br />ROOF UNDERLAYMENT TO <br />TURN UP BLOCKING MIN 8" <br />ROOF SHEATHING <br />PER PLAN <br />- ]ROOF TO WALL - <br />3"=1'-0" <br />WALL SHEATHING PER PLAN <br />STUCCO ON FRAME — 7/8" 3—COAT SAND <br />FINISH STUCCO ON SELF FURRING LATH ON <br />2— LAYERS OF WATER RESISTIVE BARRIER <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP <br />SHINGLE WATER RESISTIVE <br />BARRIER OVER WEEP SCREED---__ <br />WEEP SCREED <br />HOLD 1/4" AIR GAP <br />BETWEEN WEEP <br />SCREED AND FLASHING <br />CONT SELF ADHERED FLASHING TO <br />LAP FLASHING AND TURN 3" UP WALL ---- <br />PT 1X BLOCKING <br />COUNTER FLASHING <br />00 <br />PAN FLASHING 6" MIN—`� <br />ROOF UNDERLAYMENT TO <br />TURN UP BLOCKING MIN 6"---- <br />CONT SELF ADHERED FLASHING <br />TURN 3" UP BLOCKING <br />TILE ROOF PER SPECS---_ <br />2X NAILER SECURELY <br />FASTENED TO DECK — <br />ROOF SHEATHING <br />PER PLAN <br />NOTE: <br />ALL LATH AND LATH <br />ATTACHMENTS TO BE <br />OUT OF CORROSION <br />—RESISTANT MATERIAL <br />HEAD WALL <br />P'LE ROOF PER SPECS <br />RLAYMENT <br />IINGLE OVER <br />=DGE <br />SHEATHING <br />'LAN <br />=DGE <br />UB FASCIA <br />ADHERED WRB TO <br />'LE OVER WRB ON <br />BELOW <br />INUM BRAKE METAL WRAP <br />BACKER ROD <br />>EALANT <br />CO 'T MOULDING <br />OFF BRAKE METAL <br />IN <br />CO ON FRAME — 7/8" <br />�T SAND FINISH STUCCO <br />=LF FURRING LATH ON 2— <br />RS OF WATER RESISTIVE <br />IER COMPLYING WITH <br />E2556, TYPE 1 (TYP) <br />SHEATHING PER PLAN <br />FLASHING REQUIREMENTS <br />FIBER CEMENT SIDING <br />R730.1 GENERAL. EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A <br />PER ELEVATIONS <br />WEATHER -RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR WALL ENVELOPE <br />SHALL INCLUDE FLASHING AS DESCRIBED IN SECTION R703.4. <br />WALL SHEATHING PER PLAN <br />WALL SHEATHING PER PLAN <br />R703.1 .1 WATER RESISTANCE. THE EXTERIOR WALL ENVELOPE SHALL BE DIMENSIONED <br />SHINGLE WATER RESISTIVE <br />AND CONSTRUCTED IN A MANNER THAT PREVENTS THE ACCUMULATION OF WATER <br />BARRIER OVER FLASHING <br />FIBER CEMENT SIDING <br />WITHIN THE WALL ASSEMBLY BY PROVIDING A WATER-RESISTANT BARRIER BEHIND THE <br />PER ELEVATIONS <br />EXTERIOR CLADDING AS REQUIRED BY SECTION R703.2 AND A MEANS OF DRAINING TO <br />STARTER STRIP <br />THE EXTERIOR WATER THAT PENETRATES THE EXTERIOR CLADDING. <br />SHINGLE WATER RESISTIVE <br />BARRIER OVER FLASHING <br />R703.2 WATER RESISTIVE BARRIER, ONE LAYER OF NO.15 ASPHALT FELT, FREE FROM <br />HOLD 1/4" AIR GAP <br />HOLES, COMPLY WITH ASTM D226 FOR TYPE 1 FELT OR OTHER APPROVED <br />BETWEEN SIDING AND <br />STARTER STRIP <br />WATER -RESISTIVE BARRIER SHALL BE APPLIED OVER STUDS OR SHEATHING OF ALL <br />FLASHING <br />HOLD 1/4" AIR GAP <br />EXTERIOR WALLS NO. 15 ASPHALT FELT SHALL BE APPLIED HORIZONTALLY, WITH THE <br />COUNTER FLASHING <br />BETWEEN SIDING AND <br />UPPER LAYER LAPPED OVER THE LOWER LAYER NOT LESS THAN 2 INCHES. WHERE <br />FLASHING <br />JOINTS OCCUR, FELT SHALL BE LAPPED NOT LESS THAN 6 INCHES. OTHER APPROVED <br />CONT SELF ADHERED FLASHING TO <br />MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE WATER -RESISTIVE <br />LAP FLASHING AND TURN 3" UP WALL <br />CONT SELF ADHERED FLASHING TO <br />BARRIER MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE NO.15 ASPHALT FELT <br />LAP FLASHING AND TURN 3" UP WALL <br />OR OTHER APPROVED WATER -RESISTIVE BARRIER MATERIAL SHALL BE CONTINUOUS <br />FLASHING <br />TO THE TOP OF WALLS AND TERMINATED AT PENETRATIONS AND BUILDING <br />PT 1X10 BLOCKING <br />PT 1X BLOCKING <br />APPENDAGES IN A MANNER TO MEET THE REQUIREMENTS OF THE EXTERIOR WALL <br />ENVELOPE AS DESCRIBED IN SECTION R703.1. <br />CONT SELF ADHERED FLASHING <br />COUNTER FLASHING <br />TURN 3" UP BLOCKING <br />R703.7.3 WATER -RESISTIVE BARRIERS WATER -RESISTIVE BARRIERS SHALL BE <br />00 <br />PAN FLASHING 6" MIN <br />INSTALLED AS REQUIRED IN SECTION R703.2 AND, WHERE APPLIED OVER WOOD -BASED <br />CEMENT MORTAR <br />SHEATHING, SHALL INCLUDE A WATER -RESISTIVE VAPOR -PERMEABLE BARRIER WITH A <br />ROOF UNDERLAYMENT TO <br />PERFORMANCE AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. THE <br />TILE ROOF PER SPECS <br />TURN UP BLOCKING MIN 6" <br />INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH THAT EACH LAYER <br />ROOF UNDERLAYMENT TO <br />CONT SELF ADHERED FLASHING <br />PROVIDES A SEPARATE CONTINUOUS PLANE AND ANY FLASHING (INSTALLED IN <br />TURN UP BLOCKING MIN 8" <br />TURN 3" UP BLOCKING <br />ACCORDANCE WITH SECTION R703.4) INTENDED TO DRAIN TO THE WATER -RESISTIVE <br />BARRIER IS DIRECTED BETWEEN THE LAYERS. <br />ROOF SHEATHING <br />TILE ROOF PER SPECS' <br />PER PLAN <br />EXCEPTION: WHERE THE WATER -RESISTIVE BARRIER THAT IS APPLIED OVER <br />2X NAILER SECURELY <br />WOOD -BASED SHEATHING HAS A WATER RESISTANCE EQUAL TO OR GREATER <br />FASTENED TO DECK <br />THAN THAT OF 60-MINUTE GRADE D PAPER AND IS SEPARATED FROM THE STUCCO <br />BY AN INTERVENING SUBSTANTIALLY NON -WATER -ABSORBING LAYER OR <br />ROOF SHEATHING <br />DESIGNED DRAINAGE SPACE. <br />PER PLAN <br />R703.4 FLASHING. APPROVED METAL FLASHING, VINYL FLASHING, SELF -ADHERED <br />MEMBRANES AND MECHANICALLY ATTACHED FLEXIBLE FLASHING SHALL BE APPLIED <br />-FASHION OR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. SHINGLE <br />METAL FLASHING SHALL BE CORROSION RESISTANT. FLUID -APPLIED MEMBRANES USED <br />AS FLASHING SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S <br />RAKE WALL <br />HEAD WALL <br />RAKE WALL <br />INSTRUCTIONS, ALL FLASHING SHALL BE APPLIED IN A MANNER TO PREVENT THE <br />ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE <br />R__OOF TO WALL - BARREL TILE TO SIDING <br />W P 16 <br />_ <br />WP 17 <br />BUILDING STRUCTURAL FRAMING COMPONENTS. <br />3�� 1 —0" <br />SELF -ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH MMA 711. ALL <br />EXTERIOR FENESTRATION PRODUCTS SHALL BE SEALED AT THE JUNCTURE WITH THE <br />BUILDING WALL WITH A SEALANT COMPLYING WITH AAMA 800 OR ASTM C920 CLASS 25 <br />GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION, <br />ASTMC1281, MMA 812, OR OTHER APPROVED STANDARD AS APPROPRIATE FOR THE <br />TYPE OF SEALANT. FLUID -APPLIED MEMBRANES USED AS FLASHING IN EXTERIOR <br />WALLS SHALL COMPLY WITH AAMA 714. THE FLASHING SHALL EXTEND TO THE SURFACE <br />OF THE EXTERIOR WALL FINISH. APPROVED FLASHINGS SHALL BE INSTALLED AT THE <br />FOLLOWING LOCATIONS: <br />1. 1. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW <br />AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL <br />FINISH OR TO THE WATER -RESISTIVE BARRIER COMPLYING WITH SECTION 703.2 <br />FOR SUBSEQUENT DRAINAGE, MECHANICALLY ATTACHED FLEXIBLE FLASHINGS <br />SHALL COMPLY WITH MMA 712. FLASHING AT EXTERIOR WINDOW AND DOOR <br />OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR MORE OF THE <br />FOLLOWING: <br />1.1 THE FENESTRATION MANUFACTURER'S INSTALLATION AND FLASHING <br />INSTRUCTIONS, OR FOR APPLICATIONS NOT ADDRESSED IN THE <br />FENESTRATION MANUFACTURER'S INSTRUCTIONS, IN ACCORDANCE WITH <br />THE FLASHING MANUFACTURER'S INSTRUCTIONS. WHERE FLASHING <br />INSTRUCTIONS OR DETAILS ARE NOT PROVIDED, PLAN FLASHING SHALL BE <br />INSTALLED AT THE SILL OF EXTERIOR WINDOW AND DOOR OPENINGS. PAN <br />FLASHING SHALL BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT <br />WATER TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER <br />RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. OPENINGS USING PAN <br />FLASHING SHALL INCORPORATE FLASHING OR PROTECTION AT THE HEAD <br />AND SIDES. <br />1.2 IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A <br />REGISTERED DESIGN PROFESSIONAL. <br />1.3 IN ACCORDANCE WITH THE OTHER APPROVED METHODS. <br />1.4 IN ACCORDANCE WITH FMA/AAMA 100, FMA/AAMA 200, FMA/WDMA <br />250, FMA/AAMA/WDMA 300 OR FMA/AAMA/WDMA 400. <br />2.2 AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY <br />CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH <br />PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. <br />3.3 UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL <br />COPINGS AND SILLS, <br />4.4 CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. <br />5.5 WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A <br />WALL OR FLOOR ASSEMBLY OF WOOD -FRAME CONSTRUCTION. <br />6.6 AT WALL AND ROOF INTERSECTIONS. <br />7.7 AT BUILT-IN GUTTERS. <br />MU V r' C U V C Ur- I HI L THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />31f=1 1_011 WP 1 8 1 FLASHING AND WATERPROOFING METHODS TO BE USED. <br />MAY 0 2 2023 <br />Virtual Review Assist, Inc. <br />Plans Review completed and approved <br />for compliance with the 2020 FBC 7th Edition <br />by Debra Anne Klahr PX2300 <br />N }. <br />U <br />N O� .� <br />N 0-0 O <br />O Co -0 0- <br />U CU Cl) <br />=3 CU Cu U) <br />C= OL <br />C CZ O U_ <br />CU Cn � O CU <br />� Cl) L CU O <br />_ � <br />� O CU CZ <br />cn Q <br />;i <br />s <br />6pm <br />W <br />Q <br />Z <br />Z <br />Q <br />J <br />n <br />N <br />Cn <br />0 <br />L <br />Q <br />U <br />0 <br />^^L <br />I..i� <br />MCU <br />W <br />SHEET NO. <br />WP 2.1, <br />