My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6194 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6194 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 7:43:47 PM
Creation date
2/19/2025 8:20:01 AM
Metadata
Fields
Template:
Building Plans
Street #
6194
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
6224
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A/C <br />DISCONNECT <br />WP <br />GFI <br />102 <br />ir <br />bo <br />o � <br />GFI AT <br />_V _ 30" A.F.F., <br />HDMI <br />6-1" <br />LIVING <br />ROOMI <br />6'-0" <br />/ A i <br />\ M <br />DINING <br />° G A ROOM <br />rvvurt <br />. BATHS <br />TO 2ND I <br />FLR ELE& <br />IIC4;L <br />I'WGFI o C <br />WP <br />in <br />4'_8" <br />1 ENTRY <br />4-4" <br />0 <br />N <br />GFI <br />PANTRY <br />I� <br />DW ' <br />_TO <br />LISP 1 4;Air <br />> 11_ <br />o <br />v <br />GFI AT I ' <br />30 A.F.F.. <br />i <br />5'-8" 4'-3" <br />KITCHEN <br />F�M GF <br />\ I GFI <br />UTILITY <br />GFI TT <br />TWO CAR GARAGE,,, <br />48 <br />o I- <br />`V GFI <br />�_110V CLG <br />i <br />MNT. <br />- - -!- - - OUTLET_ <br />i <br />i <br />I <br />I <br />o <br />4 <br />i <br />i <br />I <br />L---- ----- <br />O <br />ELEC- <br />PANEL <br />FIRST FLOOR ELECTRICAL PLAN (ELEVATION A <br />1 !4r' = 1 r-Orr <br />FI <br />F <br />FI <br />GF <br />--J <br />ELEC <br />METER <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES, <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN 44" AFF <br />BATHROOM 39" AFF <br />LAUNDRY ROOM 36" AFF <br />EXTERIOR WATERPROOF 12" AFF <br />GARAGE GENERAL PURPOSE 42" AFF <br />RANGE 2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />METER <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />2/0 or 4/0 SER Alu <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to Tooter steel <br />OR <br />4 Bare attached to Tooter steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />SWITCH ° <br />4 1 /2" <br />DOORJAMB DUPLEX <br />OUTLET co <br />TRIM o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oZ <br />k <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT IHORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />_•I- TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />�- SWITCH AT 36" <br />3 WAY SWITCH AT 36" <br />-4-* 4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />-o DIMMER SWITCH AT 36" <br />-0 PUSH-BUTTON DOORBELL <br />CLG MNT LT FIXTURE <br />CLG MNT PREWIRE - FIXTURE BY OWNER <br />SURFACE MNT FIXTURE <br />{- WALL MNT FIXTURE _ <br />NOTE: <br />C ND OPALEX - ALTERNATE <br />TUB/SHOWERCANS MAY BE <br />4� " 50W PAR30 NFL 6WHITE BAFFLE USED IF <br />C APPROVED BY <br />C 50W MR16 4" LOW VOLTAGE OWNER <br />C 50W PAR20 NFL 4" MINI ROUND RECESS <br />�� 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-0 CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />Cos SMOKE DETECTOR <br />C SMOKE DETECTOR <br />rU-18= UNDER CABINET 18" <br />=S-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 - SINGLE 36" FLUOR STRIP <br />D-36 - DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />97,24:;;R 24" VANITY LIGHTING <br />9;;F36:;FR 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />Q EXHAUSTFAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />021 CHIMES (DELETE W/ INTERCOM) <br />J= MASTER STATION <br />1111ii-ftJ ELEC PANEL <br />El VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />A/C REGISTER <br />OT THERMOSTAT <br />On SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />0 <br />' <br />� °,i=, <br />N <br />O <br />i� b�YC <br />�a ' ,, J DOp <br />r <br />LO <br />X s00 <br />"al9 AROO p i} s b°00 <br />Ln <br />b &� <br />Q <br />RE � <br />�... <br />z <br />w <br />O <br />0 <br />w <br />Ix <br />0 <br />z <br />Q <br />/N� <br />>0'. a <br />W L.'= '0o U <br />rn <br />V) <br />N M <br />V 000 u a <br />co <br />E i t <br />V/ oM <br />=o ' o0 <br />Ell-0 <br />rn�� O U_o o Q <br />V—/ <br />• N <br />s U � Q <br />W <br />_C'! C <br />0 E'COof <br />a <br />LU 0 W <br />pWL W W 0 <br />�02_j<0 ¢��o��o <br />Q Q U <br />I— <br />�DoQZLOL Z0 0aF-< <br />Ocn�X0ZtE00mZz <br />C� O 0 <br />0 Z <br />��IL �>zYOZZ�pW0Tii <br />-1 << WQ�n_WZ <br />O❑EL <br />WU- <br />QO W �F �YpQQ <br />� p <br />Q <br />O p p < < O' <br />WQ 0 W <br />Z CN <br />O F_ <br />:D I` <br />I- co O <br />Q w CO � <br />U)L�ti <br />W <br />a 0- M <br />00 <br />Z< <br />vI- <br />Z <br />W <br />Jo <br />O <br />2 <br />2023 <br />Virt <br />ial Review <br />A <br />isk, <br />nc. <br />Plans Rev <br />ew <br />omp <br />ete <br />and <br />app <br />ON <br />for complian <br />a with <br />the20 <br />0 F <br />C 7t <br />io <br />by Di <br />bra <br />AnInc <br />Kla <br />r PY230 <br />In <br />L / <br />O <br />O <br />O <br />- <br />N <br />M <br />® <br />(`l(�/ <br />N <br />Q <br />0 <br />CV <br />Q <br />N <br />Q <br />N <br />0 <br />N <br />Q <br />N <br />O <br />- <br />O <br />N <br />O <br />r <br />CD0 <br />O <br />O <br />� <br />ems- <br />r <br />r <br />O <br />N <br />O <br />N <br />O <br />i <br />i <br />' <br />Z <br />O <br />N LO <br />W <br />O <br />O <br />O <br />0 <br />0 <br />0 <br />L> <br />r <br />N <br />M <br />V <br />Lo <br />CO <br />i <br />VJ <br />}I— <br /><z <br />w <br />O�...� <br />}� <br />W <br />K U) <br />Q <br />w00 <br />OOO <br />_V <br />=Zj <br />L <br />O <br />0W�0 <br />z <br />-< <br />N <br />0 <br />LU m�w <br />N <br />zQ0 <br />W <br />F-� <br />. <br />Q <br />O <br />V <br />QJW0 <br />z LL <br />z <br />a <br />Wz <br />0U <br />0 <br />�- <br />1 <br />W <br />z <br />z <br />z <br />w <br />W <br />J <br />~ <br />U-) <br />/ <br />0 <br />T"_ <br />LAST PLOT DATE <br />N <br />• <br />March 31, 2023 <br />z ® <br />® = <br />1 ST FLOOR <br />ELECTRICAL PLAN A <br />
The URL can be used to link to this page
Your browser does not support the video tag.